File name: Pandora211s1_Agam_20240206_L2Fit_ffuh5c6d20220913p1-8.txt File generation date: 20240214T155507.2Z Data description: Level 2 spectral fitting results file Data file version: ffuh5c6p1-8 Local principal investigator: Ednofri Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 211 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora211_OF_v4d20211214.txt Instrument calibration file used: Pandora211s1_CF_v6d20220913.txt Level 1 file used: Pandora211s1_Agam_20240206_L1_smca1c6d20220913p1-8.txt Full location name: Agam Space and Atmosphere Observatory (Balai Pengamatan Antariksa dan Atmosfer/B Short location name: Agam Country of location: Indonesia Location latitude [deg]: -0.2046 Location longitude [deg]: 100.3195 Location altitude [m]: 865 Local noon date: 20240206 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 398 619 Nominal wavelengths inside fitting window [nm]: 328.5535 328.6925 328.8316 328.9706 329.1095 329.2485 329.3875 329.5265 329.6654 329.8043 329.9432 330.0822 330.2211 330.3599 330.4988 330.6377 330.7765 330.9154 331.0542 331.1930 331.3318 331.4706 331.6094 331.7482 331.8869 332.0257 332.1644 332.3031 332.4418 332.5805 332.7192 332.8579 332.9966 333.1352 333.2739 333.4125 333.5511 333.6897 333.8283 333.9669 334.1055 334.2441 334.3826 334.5211 334.6597 334.7982 334.9367 335.0752 335.2137 335.3521 335.4906 335.6290 335.7675 335.9059 336.0443 336.1827 336.3211 336.4595 336.5978 336.7362 336.8745 337.0128 337.1512 337.2895 337.4278 337.5660 337.7043 337.8426 337.9808 338.1191 338.2573 338.3955 338.5337 338.6719 338.8101 338.9482 339.0864 339.2245 339.3627 339.5008 339.6389 339.7770 339.9151 340.0531 340.1912 340.3292 340.4673 340.6053 340.7433 340.8813 341.0193 341.1573 341.2953 341.4332 341.5711 341.7091 341.8470 341.9849 342.1228 342.2607 342.3986 342.5364 342.6743 342.8121 342.9499 343.0877 343.2255 343.3633 343.5011 343.6389 343.7766 343.9144 344.0521 344.1898 344.3275 344.4652 344.6029 344.7406 344.8782 345.0159 345.1535 345.2911 345.4288 345.5664 345.7039 345.8415 345.9791 346.1166 346.2542 346.3917 346.5292 346.6667 346.8042 346.9417 347.0792 347.2166 347.3541 347.4915 347.6289 347.7663 347.9037 348.0411 348.1785 348.3158 348.4532 348.5905 348.7278 348.8652 349.0025 349.1397 349.2770 349.4143 349.5515 349.6888 349.8260 349.9632 350.1004 350.2376 350.3748 350.5120 350.6491 350.7862 350.9234 351.0605 351.1976 351.3347 351.4718 351.6088 351.7459 351.8830 352.0200 352.1570 352.2940 352.4310 352.5680 352.7050 352.8419 352.9789 353.1158 353.2527 353.3896 353.5265 353.6634 353.8003 353.9372 354.0740 354.2108 354.3477 354.4845 354.6213 354.7581 354.8948 355.0316 355.1684 355.3051 355.4418 355.5785 355.7152 355.8519 355.9886 356.1253 356.2619 356.3986 356.5352 356.6718 356.8084 356.9450 357.0816 357.2181 357.3547 357.4912 357.6277 357.7643 357.9008 358.0372 358.1737 358.3102 358.4466 358.5831 358.7195 358.8559 358.9923 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Formaldehyde effective temperature [K] Column 28: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 45: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Oxygen dimer effective temperature [K] Column 50: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Ozone effective temperature [K] Column 61: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Fitted Ring spectrum, -9e99=no fitting done or fitting not successful Column 67: Independent uncertainty of fitted Ring spectrum, -9=fitting not successful Column 68: Structured uncertainty of fitted Ring spectrum, -9=fitting not successful Column 69: Common uncertainty of fitted Ring spectrum, -9=fitting not successful Column 70: rms-based uncertainty of fitted Ring spectrum, -9=fitting not successful Column 71: Effective Ring fitting wavelength [nm], -9=fitting not done or not successful Column 72: Diffuse correction applied before fitting at effective Ring fitting wavelength [%], 0=no diffuse correction applied, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 73: Lower limit used for wavelength scaling [nm] Column 74: Upper limit used for wavelength scaling [nm] Column 75: Order of smoothing polynomial Column 76: Smoothing polynomial coefficient, order 0 Column 77: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 78: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 79: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 80: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 81: Smoothing polynomial coefficient, order 1 Column 82: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 83: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 84: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 85: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 86: Smoothing polynomial coefficient, order 2 Column 87: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 88: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 89: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 90: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 91: Smoothing polynomial coefficient, order 3 Column 92: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 93: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 94: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 95: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 96: Smoothing polynomial coefficient, order 4 Column 97: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 98: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 99: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 100: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 101: Mean value of measured data inside fitting window [same units as measurements] Column 102: Offset polynomial coefficient, order 0 Column 103: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 104: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 105: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 106: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 107: Offset polynomial coefficient, order 1 Column 108: Independent uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 109: Structured uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 110: Common uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 111: rms-based uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 112: Wavelength change polynomial coefficient, order 0 Column 113: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 114: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 115: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 116: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 117: Wavelength change polynomial coefficient, order 1 Column 118: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 119: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 120: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 121: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 122: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 123: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 124: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 125: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 126: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 127: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 128: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 129: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 130: Atmospheric variability [%], 999=no atmospheric variability was determined Column 131: Wavelength effective temperature [°C], 999=no effective temperature given Column 132: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 133: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 134: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 135: Number of bright count cycles Column 136: Number of dark count cycles Column 137: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 138: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 139: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 140: Integration time [ms] Column 141: Temperature at electronics board [°C], 999=no temperature signal Column 142: Spectrometer control temperature [°C], 999=no temperature signal Column 143: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 144: Temperature in head sensor [°C], 999=no temperature signal Column 145: Humidity in head sensor [%], -9=no humidity signal Column 146: Pressure in head sensor [hPa], -9=no pressure signal Columns 147-368: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 369-590: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------