File name: Pandora129s1_AliceSprings_20250109_L2Fit_fnvs5c2d20240111p1-8.txt
File generation date: 20250110T000341.5Z
Data description: Level 2 spectral fitting results file
Data file version: fnvs5c2p1-8
Local principal investigator: Medhavy Thankappan
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 129
Spectrometer number: 1
Processing software version used: BlickP v1.8.60
Instrument operation file used: Pandora129_OF_v3d20201201.txt
Instrument calibration file used: Pandora129s1_CF_v2d20240111.txt
Level 1 file used: Pandora129s1_AliceSprings_20250109_L1_smca1c2d20240111p1-8.txt
Full location name: Geoscience Australia, Kilgariff NT
Short location name: AliceSprings
Country of location: Australia
Location latitude [deg]: -23.7580
Location longitude [deg]: 133.8826
Location altitude [m]: 567
Local noon date: 20250109
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method)
Data caveats: None
First and last pixel inside fitting window: 933 1479
Nominal wavelengths inside fitting window [nm]: 400.0813 400.2134 400.3454 400.4774 400.6094 400.7414 400.8733 401.0053 401.1372 401.2691 401.4010 401.5329 401.6648 401.7967 401.9285 402.0604 402.1922 402.3240 402.4558 402.5876 402.7194 402.8511 402.9829 403.1146 403.2463 403.3780 403.5097 403.6413 403.7730 403.9046 404.0363 404.1679 404.2995 404.4311 404.5626 404.6942 404.8257 404.9572 405.0888 405.2203 405.3517 405.4832 405.6147 405.7461 405.8775 406.0090 406.1404 406.2717 406.4031 406.5345 406.6658 406.7971 406.9285 407.0598 407.1910 407.3223 407.4536 407.5848 407.7160 407.8473 407.9785 408.1096 408.2408 408.3720 408.5031 408.6342 408.7653 408.8964 409.0275 409.1586 409.2897 409.4207 409.5517 409.6827 409.8137 409.9447 410.0757 410.2067 410.3376 410.4685 410.5994 410.7303 410.8612 410.9921 411.1229 411.2538 411.3846 411.5154 411.6462 411.7770 411.9078 412.0385 412.1693 412.3000 412.4307 412.5614 412.6921 412.8228 412.9534 413.0841 413.2147 413.3453 413.4759 413.6065 413.7370 413.8676 413.9981 414.1286 414.2592 414.3896 414.5201 414.6506 414.7810 414.9115 415.0419 415.1723 415.3027 415.4331 415.5634 415.6938 415.8241 415.9544 416.0847 416.2150 416.3453 416.4756 416.6058 416.7361 416.8663 416.9965 417.1267 417.2568 417.3870 417.5171 417.6473 417.7774 417.9075 418.0376 418.1677 418.2977 418.4278 418.5578 418.6878 418.8178 418.9478 419.0777 419.2077 419.3376 419.4676 419.5975 419.7274 419.8573 419.9871 420.1170 420.2468 420.3766 420.5064 420.6362 420.7660 420.8958 421.0255 421.1553 421.2850 421.4147 421.5444 421.6741 421.8037 421.9334 422.0630 422.1926 422.3222 422.4518 422.5814 422.7109 422.8405 422.9700 423.0995 423.2290 423.3585 423.4880 423.6174 423.7469 423.8763 424.0057 424.1351 424.2645 424.3939 424.5232 424.6526 424.7819 424.9112 425.0405 425.1698 425.2990 425.4283 425.5575 425.6867 425.8159 425.9451 426.0743 426.2034 426.3326 426.4617 426.5908 426.7199 426.8490 426.9781 427.1072 427.2362 427.3652 427.4942 427.6232 427.7522 427.8812 428.0101 428.1391 428.2680 428.3969 428.5258 428.6547 428.7835 428.9124 429.0412 429.1700 429.2988 429.4276 429.5564 429.6852 429.8139 429.9426 430.0714 430.2001 430.3287 430.4574 430.5861 430.7147 430.8433 430.9719 431.1005 431.2291 431.3577 431.4862 431.6148 431.7433 431.8718 432.0003 432.1288 432.2572 432.3857 432.5141 432.6425 432.7709 432.8993 433.0277 433.1560 433.2844 433.4127 433.5410 433.6693 433.7976 433.9258 434.0541 434.1823 434.3105 434.4388 434.5669 434.6951 434.8233 434.9514 435.0796 435.2077 435.3358 435.4639 435.5919 435.7200 435.8480 435.9760 436.1041 436.2321 436.3600 436.4880 436.6159 436.7439 436.8718 436.9997 437.1276 437.2555 437.3833 437.5112 437.6390 437.7668 437.8946 438.0224 438.1502 438.2779 438.4057 438.5334 438.6611 438.7888 438.9165 439.0441 439.1718 439.2994 439.4270 439.5546 439.6822 439.8098 439.9373 440.0649 440.1924 440.3199 440.4474 440.5749 440.7023 440.8298 440.9572 441.0846 441.2120 441.3394 441.4668 441.5942 441.7215 441.8488 441.9761 442.1034 442.2307 442.3580 442.4852 442.6125 442.7397 442.8669 442.9941 443.1213 443.2484 443.3756 443.5027 443.6298 443.7569 443.8840 444.0110 444.1381 444.2651 444.3922 444.5192 444.6462 444.7731 444.9001 445.0270 445.1540 445.2809 445.4078 445.5347 445.6615 445.7884 445.9152 446.0420 446.1688 446.2956 446.4224 446.5492 446.6759 446.8026 446.9293 447.0560 447.1827 447.3094 447.4360 447.5627 447.6893 447.8159 447.9425 448.0691 448.1956 448.3222 448.4487 448.5752 448.7017 448.8282 448.9546 449.0811 449.2075 449.3340 449.4604 449.5867 449.7131 449.8395 449.9658 450.0921 450.2185 450.3447 450.4710 450.5973 450.7235 450.8498 450.9760 451.1022 451.2284 451.3545 451.4807 451.6068 451.7330 451.8591 451.9852 452.1112 452.2373 452.3634 452.4894 452.6154 452.7414 452.8674 452.9933 453.1193 453.2452 453.3712 453.4971 453.6230 453.7488 453.8747 454.0005 454.1264 454.2522 454.3780 454.5037 454.6295 454.7553 454.8810 455.0067 455.1324 455.2581 455.3838 455.5094 455.6351 455.7607 455.8863 456.0119 456.1375 456.2630 456.3886 456.5141 456.6396 456.7651 456.8906 457.0161 457.1415 457.2670 457.3924 457.5178 457.6432 457.7685 457.8939 458.0192 458.1446 458.2699 458.3952 458.5204 458.6457 458.7710 458.8962 459.0214 459.1466 459.2718 459.3970 459.5221 459.6472 459.7724 459.8975 460.0226 460.1476 460.2727 460.3977 460.5228 460.6478 460.7728 460.8977 461.0227 461.1477 461.2726 461.3975 461.5224 461.6473 461.7722 461.8970 462.0218 462.1467 462.2715 462.3963 462.5210 462.6458 462.7705 462.8952 463.0200 463.1447 463.2693 463.3940 463.5186 463.6433 463.7679 463.8925 464.0171 464.1416 464.2662 464.3907 464.5152 464.6397 464.7642 464.8887 465.0131 465.1376 465.2620 465.3864 465.5108 465.6352 465.7595 465.8839 466.0082 466.1325 466.2568 466.3811 466.5054 466.6296 466.7538 466.8781 467.0023 467.1264 467.2506 467.3748 467.4989 467.6230 467.7471 467.8712 467.9953 468.1193 468.2434 468.3674 468.4914 468.6154 468.7394 468.8633 468.9873 469.1112 469.2351 469.3590 469.4829 469.6067 469.7306 469.8544 469.9782
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Water vapor effective temperature [K]
Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Molecular iodine effective temperature [K]
Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Nitrogen dioxide effective temperature [K]
Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful
Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 60: Oxygen dimer effective temperature [K]
Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful
Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 71: Ozone effective temperature [K]
Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 82: Iodine dioxide effective temperature [K]
Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful
Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 90: Lower limit used for wavelength scaling [nm]
Column 91: Upper limit used for wavelength scaling [nm]
Column 92: Order of smoothing polynomial
Column 93: Smoothing polynomial coefficient, order 0
Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 98: Smoothing polynomial coefficient, order 1
Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 103: Smoothing polynomial coefficient, order 2
Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 108: Smoothing polynomial coefficient, order 3
Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 113: Smoothing polynomial coefficient, order 4
Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 118: Mean value of measured data inside fitting window [same units as measurements]
Column 119: Offset polynomial coefficient, order 0
Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 124: Wavelength change polynomial coefficient, order 0
Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 129: Wavelength change polynomial coefficient, order 1
Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 136: Resolution change polynomial coefficient, order 0
Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 148: Wavelength effective temperature [�C], 999=no effective temperature given
Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 152: Number of bright count cycles
Column 153: Number of dark count cycles
Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 157: Integration time [ms]
Column 158: Spectrometer control temperature [�C], 999=no temperature signal
Column 159: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Column 160: Temperature in head sensor [�C], 999=no temperature signal
Column 161: Temperature at electronics board 1 [�C], 999=no temperature signal
Column 162: Temperature at electronics board 2 [�C], 999=no temperature signal
Column 163: Humidity in head sensor [%], -9=no humidity signal
Column 164: Pressure in head sensor [hPa], -9=no pressure signal
Columns 165-711: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 712-1258: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------