File name: Pandora207s1_ArlingtonTX_20221225_L2Fit_fwvt1c4d20221007p1-8.txt File generation date: 20240212T212627.8Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c4p1-8 Local principal investigator: Yang Li Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 207 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora207_OF_v5d20210722.txt Instrument calibration file used: Pandora207s1_CF_v4d20221007.txt Level 1 file used: Pandora207s1_ArlingtonTX_20221225_L1_smca1c4d20221007p1-8.txt Full location name: University Of Texas, Arlington Science Hall Short location name: ArlingtonTX Country of location: United States Location latitude [deg]: 32.7316 Location longitude [deg]: -97.1142 Location altitude [m]: 15 Local noon date: 20221225 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1614 1762 Nominal wavelengths inside fitting window [nm]: 492.0842 492.2059 492.3276 492.4493 492.5710 492.6927 492.8144 492.9360 493.0576 493.1792 493.3008 493.4224 493.5439 493.6655 493.7870 493.9085 494.0300 494.1514 494.2729 494.3943 494.5157 494.6371 494.7585 494.8799 495.0012 495.1226 495.2439 495.3652 495.4865 495.6077 495.7290 495.8502 495.9714 496.0926 496.2138 496.3350 496.4561 496.5773 496.6984 496.8195 496.9405 497.0616 497.1827 497.3037 497.4247 497.5457 497.6667 497.7876 497.9086 498.0295 498.1504 498.2713 498.3922 498.5131 498.6339 498.7547 498.8755 498.9963 499.1171 499.2379 499.3586 499.4793 499.6000 499.7207 499.8414 499.9621 500.0827 500.2033 500.3239 500.4445 500.5651 500.6856 500.8062 500.9267 501.0472 501.1677 501.2881 501.4086 501.5290 501.6494 501.7698 501.8902 502.0106 502.1309 502.2512 502.3716 502.4919 502.6121 502.7324 502.8526 502.9729 503.0931 503.2133 503.3334 503.4536 503.5737 503.6938 503.8139 503.9340 504.0541 504.1742 504.2942 504.4142 504.5342 504.6542 504.7741 504.8941 505.0140 505.1339 505.2538 505.3737 505.4936 505.6134 505.7332 505.8530 505.9728 506.0926 506.2124 506.3321 506.4518 506.5715 506.6912 506.8109 506.9305 507.0502 507.1698 507.2894 507.4090 507.5285 507.6481 507.7676 507.8871 508.0066 508.1261 508.2456 508.3650 508.4844 508.6038 508.7232 508.8426 508.9620 509.0813 509.2006 509.3199 509.4392 509.5585 509.6778 509.7970 509.9162 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 251-399: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20221225T135620.0Z 8394.580787 22 1 10.08 2 85.76 121.38 113.15 105.18 0.00 1 0.00 1 0 22 4.549e-03 4.519e-03 1.247e-04 1.246e-04 4.965909e+03 7.799100e+00 3.384705e+02 -6.000000e+00 2.514322e+02 283.46 -2.00 20.00 -2.00 505.31 0.00e+00 1.248487e-03 3.445541e-06 6.935412e-05 -6.000000e+00 1.278408e-04 283.46 -2.00 20.00 -2.00 500.62 0.00e+00 9.062458e-01 2.434535e-03 3.833206e-02 -6.000000e+00 9.000872e-02 224.15 -2.00 3.32 -2.00 502.19 0.00e+00 11.030 0.019 489.00 513.00 1 2.6136e-01 1.8639e-04 1.6449e-02 -6.0000e+00 6.8914e-03 -1.9557e-03 4.8058e-05 1.2361e-03 -6.0000e+00 1.8069e-03 2.8523e-01 1.5113e-03 1.1815e-05 4.6755e-05 -6.0000e+00 4.4628e-04 1.6963e-02 -3.4194e-04 11 8 0 10 0 0 12.66 19.63 0.94 0.01696 0.02745 537 183 2 2 0 17.460 14.98 19.63 5.13 20.67 20.67 10.7 876.41 -956 -795 -377 -117 211 516 554 481 326 170 80 -200 -556 -659 -677 -536 -289 39 220 303 407 366 361 585 618 737 712 308 -336 -493 -586 -565 -131 271 263 298 246 -66 -262 -247 -181 -34 172 362 491 594 557 443 94 -392 -719 -992 -971 -642 -283 -14 259 300 310 351 411 532 533 506 384 294 173 -14 -394 -512 -362 -280 -81 22 -28 -178 -250 -545 -729 -738 -632 -660 -557 -258 -243 -219 -282 -313 -271 -155 154 419 420 518 590 377 67 -467 -836 -1031 -795 -509 -25 7 93 95 -211 -331 -229 -132 -19 204 366 557 765 854 830 583 502 287 167 158 272 171 325 369 272 416 504 136 17 -97 -402 -510 -310 -315 -121 50 134 162 289 295 340 311 68 -294 -682 -874 -969 -901 -760 -359 -115 207 516 565 495 336 173 80 -199 -547 -640 -657 -524 -286 40 221 308 415 374 369 600 637 761 732 314 -334 -492 -578 -562 -129 276 267 304 248 -68 -268 -251 -185 -35 173 370 505 611 570 447 97 -392 -701 -980 -955 -620 -281 -13 262 305 315 355 417 543 546 517 388 293 170 -14 -392 -504 -355 -277 -81 21 -27 -174 -247 -532 -708 -716 -617 -652 -537 -251 -240 -217 -280 -310 -269 -154 154 427 419 512 590 369 64 -450 -793 -973 -757 -483 -25 7 93 95 -209 -324 -224 -131 -19 208 376 560 773 868 850 597 509 287 169 159 274 174 331 365 269 411 498 138 17 -96 -395 -501 -307 -310 -122 51 138 164 295 303 350 321 70 -299 -699 -881 -974 SQ 20221225T135630.4Z 8394.580907 22 2 10.00 2 85.73 121.41 113.12 105.20 0.00 1 0.00 1 0 22 4.537e-03 4.507e-03 1.237e-04 1.236e-04 4.942629e+03 7.717334e+00 3.366517e+02 -6.000000e+00 2.507286e+02 283.46 -2.00 20.00 -2.00 505.30 0.00e+00 1.227142e-03 3.414741e-06 6.822180e-05 -6.000000e+00 1.274837e-04 283.46 -2.00 20.00 -2.00 500.61 0.00e+00 8.975204e-01 2.414586e-03 3.818094e-02 -6.000000e+00 8.975797e-02 224.15 -2.00 3.32 -2.00 502.19 0.00e+00 10.977 0.018 489.00 513.00 1 2.5834e-01 1.8481e-04 1.6363e-02 -6.0000e+00 6.8722e-03 -1.7911e-03 4.7696e-05 1.2305e-03 -6.0000e+00 1.8019e-03 2.8858e-01 1.5442e-03 1.1714e-05 4.6935e-05 -6.0000e+00 4.4504e-04 1.6524e-02 -3.4023e-04 11 8 0 10 0 0 17.95 19.64 0.93 0.01652 0.02724 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 876.41 -949 -815 -378 -109 209 491 571 459 363 163 83 -188 -550 -645 -668 -552 -266 39 213 299 408 372 348 596 622 702 703 297 -338 -490 -565 -578 -148 280 271 311 228 -70 -244 -235 -170 -16 187 363 493 569 516 422 102 -400 -722 -1008 -964 -658 -290 -19 253 328 289 332 404 526 520 530 387 294 163 4 -378 -504 -358 -293 -63 23 -42 -173 -251 -573 -735 -729 -638 -681 -541 -240 -232 -230 -292 -316 -266 -154 161 422 417 507 584 384 77 -464 -849 -1039 -776 -487 -24 8 87 82 -216 -309 -216 -137 -28 226 377 552 766 849 841 566 528 280 158 168 267 180 326 362 262 411 514 120 31 -84 -391 -513 -292 -324 -125 63 130 147 266 299 339 318 61 -326 -681 -866 -972 -899 -782 -362 -108 206 494 585 460 364 167 84 -188 -543 -630 -650 -541 -264 39 215 306 418 382 358 614 644 727 726 303 -338 -490 -560 -577 -146 285 276 318 231 -70 -250 -240 -175 -16 190 372 509 587 530 428 102 -402 -706 -970 -923 -638 -289 -19 256 334 295 337 412 539 535 543 393 295 161 4 -377 -498 -353 -291 -62 23 -41 -170 -242 -562 -716 -710 -626 -655 -524 -234 -229 -229 -291 -314 -265 -154 162 419 417 503 586 378 74 -450 -808 -984 -741 -463 -23 8 87 82 -215 -303 -212 -136 -28 225 378 557 777 867 864 582 536 281 157 169 269 178 324 359 261 408 510 118 31 -84 -385 -505 -290 -320 -126 64 131 150 272 308 350 329 63 -332 -681 -876 -981 SQ 20221225T135640.7Z 8394.581026 22 3 9.95 2 85.70 121.43 113.08 105.22 0.00 1 0.00 1 0 22 4.531e-03 4.503e-03 1.231e-04 1.230e-04 4.915927e+03 7.674911e+00 3.352673e+02 -6.000000e+00 2.504263e+02 283.46 -2.00 20.00 -2.00 505.31 0.00e+00 1.227046e-03 3.391981e-06 6.800481e-05 -6.000000e+00 1.273310e-04 283.46 -2.00 20.00 -2.00 500.63 0.00e+00 8.939070e-01 2.397149e-03 3.814334e-02 -6.000000e+00 8.965178e-02 224.15 -2.00 3.32 -2.00 502.20 0.00e+00 10.924 0.018 489.00 513.00 1 2.5625e-01 1.8337e-04 1.6282e-02 -6.0000e+00 6.8641e-03 -1.7346e-03 4.7366e-05 1.2273e-03 -6.0000e+00 1.7998e-03 2.9147e-01 1.5944e-03 1.1658e-05 4.7157e-05 -6.0000e+00 4.4451e-04 1.5420e-02 -3.3530e-04 11 8 0 10 0 0 17.77 19.64 0.93 0.01542 0.02648 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 877.21 -972 -814 -373 -106 191 475 563 471 353 187 81 -165 -569 -609 -684 -568 -256 54 217 278 430 358 378 582 602 702 727 287 -349 -497 -576 -552 -146 288 274 313 220 -70 -267 -244 -176 -17 168 349 519 570 524 430 94 -402 -713 -1008 -949 -645 -273 -30 235 278 286 328 431 526 530 513 405 287 175 -26 -386 -482 -383 -301 -64 17 -57 -186 -244 -527 -730 -736 -658 -667 -541 -249 -227 -239 -309 -315 -266 -140 158 408 441 490 604 366 65 -466 -835 -1014 -786 -473 -47 24 83 90 -225 -322 -227 -132 -5 223 393 559 758 843 818 592 513 310 156 160 279 172 306 371 290 442 511 141 0 -64 -430 -504 -315 -321 -148 41 132 135 253 304 343 324 60 -317 -684 -867 -941 -925 -760 -359 -102 190 480 562 474 355 186 82 -166 -565 -597 -670 -560 -255 53 220 285 442 369 390 603 609 710 753 295 -350 -484 -574 -537 -145 295 280 322 225 -70 -268 -243 -175 -17 171 359 538 591 541 438 94 -406 -700 -974 -913 -628 -273 -30 239 285 293 335 441 541 547 528 413 288 174 -26 -376 -479 -379 -292 -62 17 -56 -183 -236 -519 -714 -720 -629 -644 -526 -244 -225 -239 -309 -314 -266 -141 155 406 443 488 591 362 63 -440 -799 -965 -754 -452 -47 24 84 90 -224 -317 -224 -132 -5 223 396 566 772 865 845 611 524 313 155 157 275 171 305 370 290 441 509 140 0 -64 -425 -498 -314 -319 -150 41 134 138 260 314 356 337 62 -324 -687 -880 -952 SQ 20221225T135650.9Z 8394.581144 22 4 9.91 2 85.67 121.45 113.05 105.24 0.00 1 0.00 1 0 22 4.506e-03 4.474e-03 1.228e-04 1.227e-04 4.892318e+03 7.639254e+00 3.342661e+02 -6.000000e+00 2.490491e+02 283.46 -2.00 20.00 -2.00 505.31 0.00e+00 1.227087e-03 3.386130e-06 6.806069e-05 -6.000000e+00 1.266304e-04 283.46 -2.00 20.00 -2.00 500.64 0.00e+00 8.907437e-01 2.390816e-03 3.791156e-02 -6.000000e+00 8.915793e-02 224.15 -2.00 3.32 -2.00 502.20 0.00e+00 10.872 0.018 489.00 513.00 1 2.5821e-01 1.8280e-04 1.6201e-02 -6.0000e+00 6.8263e-03 -1.6544e-03 4.7259e-05 1.2207e-03 -6.0000e+00 1.7898e-03 2.9314e-01 1.5874e-03 1.1630e-05 4.7419e-05 -6.0000e+00 4.4206e-04 1.4732e-02 -3.3038e-04 11 8 0 10 0 0 17.53 19.64 0.93 0.01473 0.02574 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 877.21 -964 -791 -386 -100 185 504 567 488 338 178 86 -177 -533 -616 -666 -529 -243 72 201 292 397 345 362 591 610 693 704 275 -334 -496 -566 -552 -157 280 281 330 238 -69 -265 -238 -181 -42 163 354 466 572 519 432 104 -399 -721 -991 -935 -615 -291 -57 239 295 280 346 387 528 509 518 384 278 188 -27 -386 -508 -355 -291 -93 40 -41 -202 -252 -529 -732 -734 -652 -662 -531 -243 -235 -225 -296 -341 -281 -147 166 407 434 506 601 380 56 -468 -839 -1015 -792 -464 -30 31 72 98 -219 -343 -201 -162 -17 233 370 543 771 851 824 566 502 302 137 158 269 172 334 372 293 429 522 107 7 -88 -406 -527 -317 -313 -162 52 140 119 271 318 342 312 63 -316 -668 -865 -959 -921 -741 -373 -97 183 510 568 494 342 178 85 -178 -531 -606 -655 -523 -244 72 205 300 409 357 375 596 619 703 711 283 -337 -485 -548 -539 -156 280 288 340 243 -70 -266 -238 -181 -42 166 366 485 595 537 441 105 -392 -711 -961 -902 -601 -293 -57 244 303 287 354 397 545 513 519 393 281 187 -27 -377 -491 -341 -283 -92 40 -41 -199 -244 -507 -718 -699 -626 -642 -518 -239 -234 -225 -297 -341 -282 -144 164 406 438 506 590 376 54 -443 -805 -968 -763 -444 -30 31 73 99 -219 -340 -199 -163 -17 233 375 552 788 875 853 586 514 305 137 156 266 171 334 372 294 429 521 107 7 -88 -403 -523 -308 -312 -164 52 142 122 278 330 357 325 65 -325 -673 -857 -973 SQ 20221225T135701.0Z 8394.581261 22 5 9.91 2 85.64 121.48 113.02 105.25 0.00 1 0.00 1 0 22 4.481e-03 4.452e-03 1.229e-04 1.228e-04 4.869507e+03 7.651723e+00 3.323087e+02 -6.000000e+00 2.476412e+02 283.46 -2.00 20.00 -2.00 505.31 0.00e+00 1.231531e-03 3.388604e-06 6.866944e-05 -6.000000e+00 1.259114e-04 283.46 -2.00 20.00 -2.00 500.63 0.00e+00 8.908694e-01 2.392445e-03 3.783494e-02 -6.000000e+00 8.864735e-02 224.15 -2.00 3.32 -2.00 502.20 0.00e+00 10.821 0.018 489.00 513.00 1 2.6807e-01 1.8299e-04 1.6124e-02 -6.0000e+00 6.7873e-03 -1.6287e-03 4.7289e-05 1.2154e-03 -6.0000e+00 1.7794e-03 2.9239e-01 1.4536e-03 1.1626e-05 4.6992e-05 -6.0000e+00 4.3954e-04 1.4390e-02 -3.2244e-04 11 8 0 10 0 0 26.75 19.64 0.92 0.01439 0.02447 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 877.21 -916 -780 -356 -103 206 524 554 459 328 179 112 -160 -560 -653 -673 -556 -270 52 215 278 408 342 343 589 604 724 694 298 -342 -484 -547 -540 -150 269 276 322 230 -69 -232 -256 -197 -29 176 353 473 548 521 414 100 -388 -696 -982 -945 -622 -293 -41 235 288 301 321 427 502 507 500 374 277 148 -6 -390 -491 -354 -284 -87 24 -25 -185 -217 -538 -740 -722 -633 -672 -548 -240 -224 -229 -299 -330 -281 -159 145 384 428 510 592 358 60 -445 -824 -1014 -783 -481 -30 16 66 100 -210 -324 -223 -124 -17 211 386 550 763 867 811 582 501 307 152 167 258 161 338 381 268 415 520 122 6 -97 -398 -500 -329 -319 -150 63 124 151 276 332 356 317 65 -324 -663 -867 -956 -873 -730 -343 -100 205 530 553 464 331 179 114 -161 -557 -642 -660 -548 -270 52 218 286 420 354 355 611 611 733 700 306 -344 -473 -546 -527 -150 276 283 332 235 -70 -232 -255 -197 -30 179 364 491 570 538 422 100 -392 -685 -950 -910 -606 -294 -41 239 295 308 328 437 518 509 501 382 279 147 -6 -380 -473 -351 -275 -85 23 -25 -182 -210 -514 -725 -707 -606 -650 -533 -236 -223 -229 -299 -330 -281 -160 142 384 430 509 580 355 58 -421 -789 -966 -752 -460 -30 16 66 101 -210 -319 -220 -124 -17 210 389 558 778 889 837 601 512 309 151 165 254 160 337 381 268 413 518 121 6 -96 -394 -494 -319 -317 -152 63 126 154 284 343 370 330 67 -331 -666 -881 -968 SQ 20221225T135711.2Z 8394.581379 22 6 9.94 2 85.61 121.50 112.98 105.27 0.00 1 0.00 1 0 22 4.476e-03 4.447e-03 1.238e-04 1.237e-04 4.856532e+03 7.716743e+00 3.303895e+02 -6.000000e+00 2.473698e+02 283.46 -2.00 20.00 -2.00 505.30 0.00e+00 1.241568e-03 3.418269e-06 6.892767e-05 -6.000000e+00 1.257765e-04 283.46 -2.00 20.00 -2.00 500.61 0.00e+00 8.856146e-01 2.416981e-03 3.777375e-02 -6.000000e+00 8.855665e-02 224.15 -2.00 3.32 -2.00 502.18 0.00e+00 10.769 0.017 489.00 513.00 1 2.9032e-01 1.8505e-04 1.6047e-02 -6.0000e+00 6.7802e-03 -1.5346e-03 4.7752e-05 1.2095e-03 -6.0000e+00 1.7778e-03 2.8813e-01 1.5755e-03 1.1725e-05 4.6421e-05 -6.0000e+00 4.3908e-04 1.5887e-02 -3.3733e-04 11 8 0 10 0 0 8.55 19.64 0.92 0.01589 0.02682 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 877.21 -933 -775 -364 -119 184 476 568 466 380 183 92 -188 -565 -664 -674 -535 -271 47 180 281 399 366 345 576 603 693 719 295 -333 -498 -532 -522 -129 280 288 308 234 -64 -254 -246 -183 -32 168 358 482 566 532 419 86 -385 -709 -973 -928 -618 -290 -44 223 291 273 319 415 526 521 485 374 281 173 -14 -364 -483 -332 -273 -84 14 -39 -173 -258 -526 -731 -718 -621 -658 -549 -246 -240 -238 -302 -306 -281 -163 147 393 436 496 604 376 39 -468 -839 -1004 -797 -484 -19 25 91 87 -200 -328 -227 -134 -10 210 388 530 773 873 823 568 513 300 148 168 265 168 322 357 267 410 540 144 26 -72 -398 -513 -302 -313 -145 50 134 134 264 320 328 309 53 -288 -658 -885 -955 -885 -745 -349 -118 182 479 582 468 381 187 93 -188 -559 -649 -657 -525 -270 48 182 287 409 376 355 594 625 719 742 302 -333 -499 -527 -522 -127 286 294 315 238 -64 -261 -251 -187 -32 170 367 498 585 546 425 86 -386 -694 -936 -888 -599 -289 -44 225 296 278 324 423 539 536 497 379 281 171 -14 -363 -476 -327 -271 -81 14 -39 -170 -255 -515 -711 -698 -609 -632 -531 -240 -237 -237 -300 -304 -279 -163 148 390 435 492 606 370 37 -454 -798 -949 -761 -460 -19 25 91 87 -198 -321 -222 -133 -11 214 389 535 783 889 844 583 520 300 150 169 267 166 318 354 265 406 534 142 26 -71 -392 -504 -299 -309 -146 51 134 136 269 329 338 319 55 -292 -675 -892 -960