File name: Pandora207s1_ArlingtonTX_20221225_L2Fit_fwvt1c6d20221007p1-8.txt File generation date: 20240911T083827.7Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c6p1-8 Local principal investigator: Yang Li Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 207 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora207_OF_v5d20210722.txt Instrument calibration file used: Pandora207s1_CF_v6d20221007.txt Level 1 file used: Pandora207s1_ArlingtonTX_20221225_L1_smca1c6d20221007p1-8.txt Full location name: University Of Texas, Arlington Science Hall Short location name: ArlingtonTX Country of location: United States Location latitude [deg]: 32.7316 Location longitude [deg]: -97.1142 Location altitude [m]: 15 Local noon date: 20221225 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 5 "But different Reference day, final winter reference" First and last pixel inside fitting window: 1614 1762 Nominal wavelengths inside fitting window [nm]: 492.0579 492.1796 492.3013 492.4230 492.5447 492.6663 492.7880 492.9096 493.0312 493.1528 493.2744 493.3959 493.5175 493.6390 493.7605 493.8820 494.0035 494.1249 494.2463 494.3678 494.4892 494.6106 494.7319 494.8533 494.9746 495.0959 495.2172 495.3385 495.4598 495.5810 495.7023 495.8235 495.9447 496.0659 496.1871 496.3082 496.4293 496.5504 496.6715 496.7926 496.9137 497.0347 497.1558 497.2768 497.3978 497.5188 497.6397 497.7607 497.8816 498.0025 498.1234 498.2443 498.3651 498.4860 498.6068 498.7276 498.8484 498.9692 499.0900 499.2107 499.3314 499.4521 499.5728 499.6935 499.8141 499.9348 500.0554 500.1760 500.2966 500.4172 500.5377 500.6583 500.7788 500.8993 501.0198 501.1402 501.2607 501.3811 501.5015 501.6219 501.7423 501.8627 501.9830 502.1034 502.2237 502.3440 502.4642 502.5845 502.7048 502.8250 502.9452 503.0654 503.1856 503.3057 503.4259 503.5460 503.6661 503.7862 503.9063 504.0263 504.1464 504.2664 504.3864 504.5064 504.6263 504.7463 504.8662 504.9862 505.1061 505.2259 505.3458 505.4657 505.5855 505.7053 505.8251 505.9449 506.0647 506.1844 506.3041 506.4238 506.5435 506.6632 506.7829 506.9025 507.0221 507.1418 507.2613 507.3809 507.5005 507.6200 507.7395 507.8590 507.9785 508.0980 508.2175 508.3369 508.4563 508.5757 508.6951 508.8145 508.9338 509.0532 509.1725 509.2918 509.4111 509.5303 509.6496 509.7688 509.8880 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 251-399: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20221225T135620.0Z 8394.580787 22 1 10.08 2 85.76 121.38 113.15 105.18 0.00 1 0.00 1 0 15 3.888e-03 3.871e-03 1.219e-04 1.217e-04 5.031716e+03 7.733175e+00 3.308932e+02 -6.000000e+00 2.186575e+02 283.46 -2.00 20.00 -2.00 505.30 0.00e+00 1.300257e-03 3.379997e-06 7.251641e-05 -6.000000e+00 1.098527e-04 283.46 -2.00 20.00 -2.00 500.64 0.00e+00 8.721310e-01 2.387479e-03 4.166537e-02 -6.000000e+00 7.746284e-02 224.15 -2.00 3.32 -2.00 502.21 0.00e+00 11.030 0.019 489.00 513.00 1 2.8196e-01 1.8278e-04 1.6508e-02 -6.0000e+00 5.9394e-03 -1.1618e-03 4.6913e-05 1.2722e-03 -6.0000e+00 1.5462e-03 2.7986e-01 4.7832e-04 1.2171e-05 4.5188e-05 -6.0000e+00 4.0404e-04 5.8938e-03 -9.7297e-05 11 8 0 10 0 0 9.83 19.63 0.77 0.00589 0.00921 537 183 2 2 0 17.460 14.98 19.63 5.13 20.67 20.67 10.7 876.41 -778 -886 -698 -500 -69 380 460 476 326 226 154 -189 -525 -580 -534 -331 -102 85 123 255 458 466 483 668 653 745 638 152 -391 -304 -313 -323 -43 66 -106 30 140 -105 -236 -161 -104 34 215 348 415 530 511 397 16 -410 -597 -733 -610 -371 -240 -153 73 189 312 428 450 480 415 357 264 259 170 -62 -425 -397 -176 -139 -50 -98 -254 -272 -167 -392 -557 -559 -516 -596 -423 -166 -250 -267 -284 -239 -169 -8 264 344 162 284 437 233 -38 -490 -697 -741 -431 -222 -31 -300 -262 -126 -218 -129 26 10 -1 184 346 587 815 858 683 393 365 252 248 330 350 112 250 314 239 402 385 -43 -37 -18 -246 -231 -30 -241 -178 1 85 121 293 259 237 84 -221 -514 -688 -685 -735 -720 -832 -677 -485 -69 385 460 480 329 225 152 -190 -523 -570 -524 -327 -102 84 125 262 472 481 500 692 660 753 642 156 -394 -297 -303 -315 -43 68 -109 31 143 -106 -236 -161 -104 34 220 359 431 551 527 405 16 -415 -588 -710 -588 -362 -241 -153 75 194 320 438 462 495 417 357 270 261 169 -61 -415 -383 -170 -134 -49 -97 -253 -268 -162 -376 -547 -548 -495 -577 -412 -163 -249 -267 -284 -239 -169 -8 260 343 163 284 428 231 -36 -464 -669 -707 -415 -213 -31 -299 -265 -127 -218 -128 26 10 -1 184 349 596 831 880 705 406 372 254 246 326 345 111 249 314 239 401 384 -43 -36 -18 -244 -229 -30 -239 -180 1 86 124 301 268 247 87 -229 -526 -691 -697 -745 SQ 20221225T135630.4Z 8394.580907 22 2 10.00 2 85.73 121.41 113.12 105.20 0.00 1 0.00 1 0 22 3.882e-03 3.862e-03 1.213e-04 1.211e-04 5.021908e+03 7.733764e+00 3.277701e+02 -6.000000e+00 2.183197e+02 283.46 -2.00 20.00 -2.00 505.31 0.00e+00 1.281069e-03 3.364115e-06 7.149611e-05 -6.000000e+00 1.096840e-04 283.46 -2.00 20.00 -2.00 500.64 0.00e+00 8.641578e-01 2.376452e-03 4.193027e-02 -6.000000e+00 7.734531e-02 224.15 -2.00 3.32 -2.00 502.20 0.00e+00 10.977 0.018 489.00 513.00 1 2.7886e-01 1.8191e-04 1.6428e-02 -6.0000e+00 5.9304e-03 -1.0051e-03 4.6705e-05 1.2704e-03 -6.0000e+00 1.5439e-03 2.8314e-01 5.1954e-04 1.2127e-05 4.3669e-05 -6.0000e+00 4.0342e-04 6.8520e-03 -1.0543e-04 11 8 0 10 0 0 13.38 19.64 0.77 0.00685 0.01046 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 876.41 -769 -903 -696 -488 -67 359 481 457 365 221 159 -175 -517 -565 -523 -344 -77 87 119 253 462 474 473 682 659 712 632 142 -392 -299 -291 -333 -57 76 -95 45 125 -107 -215 -147 -90 54 235 352 421 508 473 380 27 -415 -597 -746 -600 -385 -245 -155 69 220 295 413 447 477 406 383 271 262 163 -41 -406 -387 -170 -151 -31 -95 -267 -266 -168 -420 -563 -551 -524 -618 -408 -149 -240 -279 -295 -244 -167 -11 267 342 154 267 423 231 -38 -499 -721 -760 -424 -212 -41 -308 -274 -143 -227 -110 35 1 -15 201 351 576 811 847 690 375 389 243 236 336 338 115 246 303 226 394 391 -63 -25 -9 -238 -237 -16 -254 -186 10 78 104 268 262 235 89 -229 -545 -686 -677 -739 -717 -854 -679 -477 -67 355 484 464 370 222 158 -172 -518 -559 -516 -342 -75 87 121 262 478 477 477 689 670 724 640 143 -397 -294 -284 -327 -57 77 -98 47 128 -109 -217 -148 -91 55 241 365 440 531 491 390 27 -410 -591 -727 -582 -378 -240 -156 71 227 304 425 448 480 410 386 270 266 163 -41 -398 -376 -165 -147 -30 -95 -267 -264 -163 -404 -538 -527 -505 -602 -399 -148 -240 -281 -288 -238 -163 -11 265 343 156 268 417 223 -37 -475 -675 -707 -398 -204 -39 -309 -279 -145 -228 -109 35 1 -15 202 356 588 831 875 716 389 400 247 236 333 336 115 247 305 227 395 392 -63 -25 -9 -231 -236 -15 -254 -190 10 79 107 277 272 246 93 -238 -561 -693 -673 -733 SQ 20221225T135640.7Z 8394.581026 22 3 9.95 2 85.70 121.43 113.08 105.22 0.00 1 0.00 1 0 22 3.882e-03 3.862e-03 1.206e-04 1.205e-04 4.995720e+03 7.671909e+00 3.264078e+02 -6.000000e+00 2.183102e+02 283.46 -2.00 20.00 -2.00 505.30 0.00e+00 1.285919e-03 3.349267e-06 7.166756e-05 -6.000000e+00 1.096794e-04 283.46 -2.00 20.00 -2.00 500.63 0.00e+00 8.622657e-01 2.367703e-03 4.151962e-02 -6.000000e+00 7.734193e-02 224.15 -2.00 3.32 -2.00 502.20 0.00e+00 10.924 0.018 489.00 513.00 1 2.7656e-01 1.8137e-04 1.6343e-02 -6.0000e+00 5.9301e-03 -9.7636e-04 4.6558e-05 1.2602e-03 -6.0000e+00 1.5438e-03 2.8597e-01 5.3150e-04 1.2045e-05 4.4457e-05 -6.0000e+00 4.0341e-04 5.4945e-03 -9.7146e-05 11 8 0 10 0 0 12.22 19.64 0.77 0.00549 0.00918 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 877.21 -791 -902 -691 -485 -83 344 474 471 357 247 159 -151 -535 -527 -539 -360 -67 101 123 232 483 459 503 669 641 714 656 134 -401 -305 -301 -307 -55 85 -92 49 118 -105 -237 -155 -94 56 218 342 451 513 485 392 22 -414 -583 -743 -582 -368 -223 -162 56 175 296 413 478 481 420 371 293 259 179 -68 -411 -362 -192 -156 -29 -98 -279 -276 -158 -372 -556 -556 -542 -603 -407 -158 -235 -288 -313 -244 -169 1 263 327 178 250 443 212 -51 -501 -709 -738 -437 -202 -67 -296 -281 -139 -238 -126 22 3 7 196 366 582 802 842 668 400 374 275 234 328 351 108 227 314 255 426 390 -40 -55 13 -276 -227 -37 -250 -206 -10 82 94 258 269 241 97 -229 -535 -688 -677 -707 -741 -857 -655 -476 -84 341 480 481 364 249 158 -149 -521 -524 -535 -360 -66 102 126 233 488 465 509 679 654 730 668 136 -408 -301 -295 -303 -55 86 -96 51 122 -107 -240 -156 -95 57 224 356 459 522 491 403 23 -410 -581 -727 -567 -364 -219 -164 58 176 298 415 481 487 426 376 294 264 180 -67 -405 -352 -187 -153 -28 -98 -281 -275 -154 -359 -534 -534 -525 -590 -401 -156 -229 -282 -307 -239 -166 1 261 329 181 252 438 206 -50 -480 -666 -690 -412 -195 -66 -298 -278 -137 -240 -126 21 3 7 198 373 596 826 872 677 406 386 279 235 326 350 108 229 316 258 429 392 -41 -54 12 -268 -220 -36 -250 -205 -10 84 97 267 280 246 99 -233 -553 -697 -676 -703 SQ 20221225T135650.9Z 8394.581144 22 4 9.91 2 85.67 121.45 113.05 105.24 0.00 1 0.00 1 0 22 3.857e-03 3.838e-03 1.201e-04 1.200e-04 4.978999e+03 7.634903e+00 3.262720e+02 -6.000000e+00 2.169307e+02 283.46 -2.00 20.00 -2.00 505.30 0.00e+00 1.287959e-03 3.336303e-06 7.180952e-05 -6.000000e+00 1.089858e-04 283.46 -2.00 20.00 -2.00 500.63 0.00e+00 8.576074e-01 2.359655e-03 4.113413e-02 -6.000000e+00 7.685206e-02 224.15 -2.00 3.32 -2.00 502.19 0.00e+00 10.872 0.018 489.00 513.00 1 2.7859e-01 1.8078e-04 1.6260e-02 -6.0000e+00 5.8926e-03 -9.0095e-04 4.6398e-05 1.2523e-03 -6.0000e+00 1.5340e-03 2.8762e-01 5.0174e-04 1.2001e-05 4.4729e-05 -6.0000e+00 4.0086e-04 4.9176e-03 -9.2382e-05 11 8 0 10 0 0 16.58 19.64 0.76 0.00492 0.00840 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 877.21 -785 -882 -708 -483 -93 370 476 487 341 237 163 -164 -501 -536 -524 -325 -58 116 103 243 448 444 485 675 646 703 633 122 -387 -305 -293 -310 -70 74 -87 65 135 -105 -236 -150 -100 29 211 346 397 515 482 395 35 -408 -589 -724 -567 -339 -242 -189 61 194 292 433 436 485 402 379 276 255 196 -65 -407 -384 -161 -143 -56 -73 -260 -288 -162 -369 -555 -551 -534 -597 -395 -149 -241 -271 -297 -268 -182 -4 272 327 173 268 441 226 -61 -503 -713 -739 -446 -194 -52 -289 -290 -127 -228 -144 50 -24 -3 209 346 569 818 852 677 380 370 271 220 329 344 110 259 319 262 417 405 -70 -44 -8 -248 -247 -36 -239 -218 3 93 82 279 287 244 88 -222 -529 -668 -671 -720 -737 -840 -673 -475 -91 368 482 498 348 240 162 -162 -489 -534 -521 -315 -57 117 106 246 453 451 492 687 662 720 646 124 -394 -302 -288 -306 -70 75 -91 67 139 -108 -239 -152 -102 30 218 350 406 526 489 407 35 -406 -588 -710 -554 -335 -239 -191 61 195 295 435 440 492 409 385 277 252 197 -65 -402 -375 -157 -141 -55 -73 -262 -287 -159 -357 -534 -531 -518 -584 -389 -148 -235 -266 -292 -263 -179 -4 271 331 176 270 437 220 -60 -482 -672 -692 -421 -188 -51 -292 -288 -126 -231 -144 50 -23 -3 211 353 584 843 860 688 386 371 277 221 328 343 111 261 322 265 421 408 -70 -44 -7 -242 -240 -35 -240 -217 3 95 85 290 291 249 91 -226 -548 -678 -670 -717 SQ 20221225T135701.0Z 8394.581261 22 5 9.91 2 85.64 121.48 113.02 105.25 0.00 1 0.00 1 0 15 3.829e-03 3.813e-03 1.203e-04 1.202e-04 4.950090e+03 7.649807e+00 3.236434e+02 -6.000000e+00 2.153479e+02 283.46 -2.00 20.00 -2.00 505.30 0.00e+00 1.291694e-03 3.344093e-06 7.229664e-05 -6.000000e+00 1.081895e-04 283.46 -2.00 20.00 -2.00 500.62 0.00e+00 8.584882e-01 2.364428e-03 4.119407e-02 -6.000000e+00 7.628925e-02 224.15 -2.00 3.32 -2.00 502.19 0.00e+00 10.821 0.018 489.00 513.00 1 2.8841e-01 1.8117e-04 1.6185e-02 -6.0000e+00 5.8495e-03 -8.6132e-04 4.6483e-05 1.2483e-03 -6.0000e+00 1.5227e-03 2.8687e-01 4.5337e-04 1.2024e-05 4.4221e-05 -6.0000e+00 3.9793e-04 4.8226e-03 -8.9551e-05 11 8 0 10 0 0 26.67 19.64 0.76 0.00482 0.00797 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 877.21 -735 -868 -673 -482 -68 393 464 459 331 238 188 -147 -528 -573 -528 -349 -81 100 120 230 460 443 467 675 641 735 622 144 -396 -294 -273 -297 -61 65 -91 56 126 -105 -203 -167 -116 43 225 346 405 491 482 375 28 -400 -567 -717 -577 -345 -243 -173 56 185 311 407 475 458 398 359 262 250 153 -47 -414 -369 -162 -138 -51 -91 -247 -274 -131 -381 -566 -542 -518 -608 -413 -148 -232 -277 -302 -259 -183 -17 250 305 166 271 431 205 -56 -481 -697 -738 -435 -210 -51 -304 -298 -128 -223 -128 26 12 -5 184 359 574 807 865 661 392 364 272 231 336 330 97 260 325 234 399 400 -59 -48 -20 -244 -222 -51 -248 -209 12 73 110 280 297 254 90 -224 -541 -667 -677 -722 -690 -826 -639 -474 -69 391 470 469 338 241 188 -146 -515 -571 -525 -349 -80 100 123 233 465 449 474 686 656 752 635 145 -403 -291 -268 -293 -61 66 -94 59 130 -108 -206 -169 -117 43 232 350 413 501 488 387 28 -397 -565 -702 -563 -341 -239 -175 56 186 313 409 478 464 404 364 264 248 154 -46 -408 -360 -158 -136 -50 -91 -248 -273 -128 -369 -544 -521 -501 -595 -407 -147 -226 -272 -297 -254 -180 -17 249 307 168 273 427 199 -55 -460 -656 -691 -410 -203 -50 -306 -296 -126 -225 -127 26 11 -5 186 366 588 831 897 670 398 376 277 232 334 329 97 262 328 236 402 403 -59 -47 -19 -237 -216 -50 -249 -208 12 75 114 291 309 260 92 -228 -559 -676 -676 -718 SQ 20221225T135711.2Z 8394.581379 22 6 9.94 2 85.61 121.50 112.98 105.27 0.00 1 0.00 1 0 15 3.826e-03 3.810e-03 1.213e-04 1.212e-04 4.929099e+03 7.695958e+00 3.215077e+02 -6.000000e+00 2.151869e+02 283.46 -2.00 20.00 -2.00 505.30 0.00e+00 1.295631e-03 3.365017e-06 7.220860e-05 -6.000000e+00 1.081085e-04 283.46 -2.00 20.00 -2.00 500.63 0.00e+00 8.515001e-01 2.377294e-03 4.125092e-02 -6.000000e+00 7.623211e-02 224.15 -2.00 3.32 -2.00 502.20 0.00e+00 10.769 0.017 489.00 513.00 1 3.1089e-01 1.8196e-04 1.6109e-02 -6.0000e+00 5.8451e-03 -7.1988e-04 4.6775e-05 1.2456e-03 -6.0000e+00 1.5216e-03 2.8271e-01 4.7704e-04 1.2143e-05 4.3832e-05 -6.0000e+00 3.9763e-04 4.9541e-03 -9.0270e-05 11 8 0 10 0 0 10.08 19.64 0.75 0.00495 0.00826 537 183 2 2 0 17.460 15.01 19.64 5.36 20.67 20.67 10.6 877.21 -752 -862 -682 -498 -91 344 477 465 383 242 169 -174 -531 -583 -529 -327 -82 95 86 235 452 468 470 662 640 703 647 140 -388 -308 -258 -278 -38 76 -79 42 130 -102 -226 -159 -103 38 215 347 410 504 488 376 9 -402 -586 -712 -565 -344 -243 -180 40 183 278 399 457 476 406 338 256 248 171 -61 -394 -366 -145 -130 -51 -104 -265 -267 -175 -373 -559 -539 -506 -594 -414 -154 -247 -286 -304 -234 -180 -18 256 317 176 258 445 224 -75 -500 -707 -720 -440 -203 -30 -287 -268 -138 -211 -129 26 7 5 187 365 556 819 872 673 376 373 262 224 336 338 105 242 300 231 392 417 -40 -33 2 -247 -237 -24 -241 -204 -3 81 90 266 282 222 77 -241 -512 -669 -700 -724 -701 -816 -666 -487 -91 341 481 473 388 243 168 -171 -533 -578 -523 -325 -80 95 88 243 469 472 474 670 651 716 656 141 -392 -303 -251 -273 -38 77 -81 44 133 -104 -228 -159 -104 38 221 359 428 527 507 385 9 -397 -580 -694 -547 -338 -238 -181 41 188 287 410 472 479 410 340 256 251 171 -60 -386 -355 -140 -127 -50 -104 -265 -265 -170 -359 -534 -515 -487 -578 -406 -152 -247 -288 -306 -235 -176 -17 253 317 178 259 438 223 -72 -476 -661 -690 -413 -196 -29 -287 -272 -140 -211 -128 25 7 5 188 369 567 838 898 697 390 383 265 224 332 334 104 242 301 232 393 417 -40 -32 2 -246 -235 -24 -240 -207 -3 82 93 274 292 232 81 -250 -525 -674 -694 -716