File name: Pandora207s1_ArlingtonTX_20230111_L2Fit_fnvs5c6d20221007p1-8.txt File generation date: 20240911T084021.5Z Data description: Level 2 spectral fitting results file Data file version: fnvs5c6p1-8 Local principal investigator: Yang Li Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 207 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora207_OF_v5d20210722.txt Instrument calibration file used: Pandora207s1_CF_v6d20221007.txt Level 1 file used: Pandora207s1_ArlingtonTX_20230111_L1_smca1c6d20221007p1-8.txt Full location name: University Of Texas, Arlington Science Hall Short location name: ArlingtonTX Country of location: United States Location latitude [deg]: 32.7316 Location longitude [deg]: -97.1142 Location altitude [m]: 15 Local noon date: 20230111 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 5 "But different Reference day, final winter reference" First and last pixel inside fitting window: 892 1434 Nominal wavelengths inside fitting window [nm]: 400.0476 400.1803 400.3131 400.4459 400.5786 400.7114 400.8441 400.9768 401.1095 401.2421 401.3748 401.5074 401.6401 401.7727 401.9053 402.0379 402.1705 402.3030 402.4356 402.5681 402.7006 402.8331 402.9656 403.0981 403.2306 403.3630 403.4955 403.6279 403.7603 403.8927 404.0251 404.1574 404.2898 404.4221 404.5544 404.6867 404.8190 404.9513 405.0836 405.2158 405.3481 405.4803 405.6125 405.7447 405.8769 406.0090 406.1412 406.2733 406.4055 406.5376 406.6697 406.8018 406.9338 407.0659 407.1979 407.3299 407.4620 407.5940 407.7259 407.8579 407.9899 408.1218 408.2537 408.3856 408.5175 408.6494 408.7813 408.9131 409.0450 409.1768 409.3086 409.4404 409.5722 409.7040 409.8357 409.9675 410.0992 410.2309 410.3626 410.4943 410.6260 410.7576 410.8893 411.0209 411.1525 411.2841 411.4157 411.5473 411.6788 411.8104 411.9419 412.0734 412.2049 412.3364 412.4679 412.5993 412.7308 412.8622 412.9936 413.1250 413.2564 413.3877 413.5191 413.6504 413.7818 413.9131 414.0444 414.1757 414.3069 414.4382 414.5694 414.7007 414.8319 414.9631 415.0943 415.2254 415.3566 415.4877 415.6188 415.7500 415.8811 416.0121 416.1432 416.2743 416.4053 416.5363 416.6673 416.7983 416.9293 417.0603 417.1912 417.3222 417.4531 417.5840 417.7149 417.8458 417.9766 418.1075 418.2383 418.3692 418.5000 418.6308 418.7615 418.8923 419.0231 419.1538 419.2845 419.4152 419.5459 419.6766 419.8073 419.9379 420.0685 420.1992 420.3298 420.4604 420.5909 420.7215 420.8520 420.9826 421.1131 421.2436 421.3741 421.5046 421.6350 421.7655 421.8959 422.0263 422.1567 422.2871 422.4175 422.5478 422.6782 422.8085 422.9388 423.0691 423.1994 423.3297 423.4600 423.5902 423.7204 423.8506 423.9808 424.1110 424.2412 424.3713 424.5015 424.6316 424.7617 424.8918 425.0219 425.1520 425.2820 425.4121 425.5421 425.6721 425.8021 425.9321 426.0620 426.1920 426.3219 426.4518 426.5817 426.7116 426.8415 426.9714 427.1012 427.2311 427.3609 427.4907 427.6205 427.7502 427.8800 428.0097 428.1395 428.2692 428.3989 428.5286 428.6582 428.7879 428.9175 429.0472 429.1768 429.3064 429.4360 429.5655 429.6951 429.8246 429.9541 430.0837 430.2132 430.3426 430.4721 430.6015 430.7310 430.8604 430.9898 431.1192 431.2486 431.3779 431.5073 431.6366 431.7659 431.8952 432.0245 432.1538 432.2831 432.4123 432.5415 432.6707 432.7999 432.9291 433.0583 433.1875 433.3166 433.4457 433.5748 433.7039 433.8330 433.9621 434.0911 434.2202 434.3492 434.4782 434.6072 434.7362 434.8651 434.9941 435.1230 435.2519 435.3808 435.5097 435.6386 435.7674 435.8963 436.0251 436.1539 436.2827 436.4115 436.5403 436.6690 436.7978 436.9265 437.0552 437.1839 437.3126 437.4412 437.5699 437.6985 437.8271 437.9557 438.0843 438.2129 438.3415 438.4700 438.5985 438.7270 438.8555 438.9840 439.1125 439.2410 439.3694 439.4978 439.6262 439.7546 439.8830 440.0114 440.1397 440.2681 440.3964 440.5247 440.6530 440.7812 440.9095 441.0377 441.1660 441.2942 441.4224 441.5506 441.6787 441.8069 441.9350 442.0632 442.1913 442.3194 442.4474 442.5755 442.7035 442.8316 442.9596 443.0876 443.2156 443.3436 443.4715 443.5995 443.7274 443.8553 443.9832 444.1111 444.2390 444.3668 444.4946 444.6225 444.7503 444.8781 445.0058 445.1336 445.2613 445.3891 445.5168 445.6445 445.7722 445.8999 446.0275 446.1551 446.2828 446.4104 446.5380 446.6656 446.7931 446.9207 447.0482 447.1757 447.3032 447.4307 447.5582 447.6856 447.8131 447.9405 448.0679 448.1953 448.3227 448.4501 448.5774 448.7048 448.8321 448.9594 449.0867 449.2139 449.3412 449.4684 449.5957 449.7229 449.8501 449.9773 450.1044 450.2316 450.3587 450.4858 450.6129 450.7400 450.8671 450.9942 451.1212 451.2482 451.3753 451.5023 451.6292 451.7562 451.8832 452.0101 452.1370 452.2639 452.3908 452.5177 452.6446 452.7714 452.8982 453.0250 453.1518 453.2786 453.4054 453.5321 453.6589 453.7856 453.9123 454.0390 454.1657 454.2923 454.4190 454.5456 454.6722 454.7988 454.9254 455.0520 455.1785 455.3050 455.4316 455.5581 455.6846 455.8110 455.9375 456.0639 456.1904 456.3168 456.4432 456.5695 456.6959 456.8223 456.9486 457.0749 457.2012 457.3275 457.4538 457.5800 457.7063 457.8325 457.9587 458.0849 458.2111 458.3372 458.4634 458.5895 458.7156 458.8417 458.9678 459.0939 459.2199 459.3460 459.4720 459.5980 459.7240 459.8500 459.9759 460.1019 460.2278 460.3537 460.4796 460.6055 460.7314 460.8572 460.9830 461.1089 461.2347 461.3604 461.4862 461.6120 461.7377 461.8634 461.9891 462.1148 462.2405 462.3662 462.4918 462.6174 462.7431 462.8687 462.9942 463.1198 463.2454 463.3709 463.4964 463.6219 463.7474 463.8729 463.9983 464.1238 464.2492 464.3746 464.5000 464.6254 464.7507 464.8761 465.0014 465.1267 465.2520 465.3773 465.5026 465.6278 465.7530 465.8783 466.0035 466.1286 466.2538 466.3790 466.5041 466.6292 466.7543 466.8794 467.0045 467.1296 467.2546 467.3796 467.5046 467.6296 467.7546 467.8796 468.0045 468.1294 468.2544 468.3793 468.5041 468.6290 468.7539 468.8787 469.0035 469.1283 469.2531 469.3779 469.5026 469.6274 469.7521 469.8768 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Spectrometer control temperature [°C], 999=no temperature signal Column 159: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 160: Temperature in head sensor [°C], 999=no temperature signal Column 161: Temperature at electronics board 1 [°C], 999=no temperature signal Column 162: Temperature at electronics board 2 [°C], 999=no temperature signal Column 163: Humidity in head sensor [%], -9=no humidity signal Column 164: Pressure in head sensor [hPa], -9=no pressure signal Columns 165-707: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 708-1250: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20230111T134917.1Z 8411.575893 218 1 21.69 2 87.49 118.02 56.68 261.22 0.00 1 0.00 1 0 97 9.555e-03 5.639e-03 5.385e-04 3.832e-04 8.184660e+03 8.154085e+01 5.559209e+02 3.865211e+02 1.938863e+03 282.68 -2.00 20.00 -2.00 452.24 0.00e+00 -3.838787e-04 4.991832e-05 4.819509e-06 2.221496e-05 1.032519e-03 282.68 -2.00 20.00 -2.00 459.65 0.00e+00 1.608102e-03 3.617761e-06 1.104149e-05 1.407024e-05 8.782065e-05 226.15 -2.00 2.08 -2.00 448.11 0.00e+00 7.763899e+06 5.557798e+04 7.634003e+04 2.345309e+05 1.401161e+06 263.86 -2.00 10.73 -2.00 461.43 0.00e+00 1.350142e+00 8.891677e-03 1.202313e-02 8.309674e-03 2.977315e-01 224.31 -2.00 3.32 -2.00 459.00 0.00e+00 -2.914666e-05 1.153325e-06 1.351418e-06 1.195741e-06 3.650754e-05 282.68 -2.00 20.00 -2.00 459.32 0.00e+00 14.733 0.045 397.00 473.00 4 1.7141e+00 4.6280e-04 3.9244e-02 4.1374e-04 1.0343e-02 -7.7849e-02 6.5092e-04 8.1985e-03 3.8666e-04 1.4819e-02 8.7584e-02 3.0370e-04 1.0818e-03 1.1730e-04 5.9986e-03 3.6037e-02 1.3575e-04 1.4815e-04 3.3162e-05 2.2960e-03 -4.0211e-02 6.3046e-05 8.0208e-05 1.8269e-05 1.2091e-03 1.2130e-02 -1.8323e-01 1.4341e-04 9.4841e-05 9.3937e-05 6.2781e-03 -1.5786e-04 4.7191e-06 1.8332e-06 3.6066e-07 1.0089e-04 1.5978e-04 6.4597e-06 2.5669e-06 4.5289e-07 1.4365e-04 3.6089e-03 -3.3852e-05 1.4709e+00 3.9217e-02 4.9922e-03 4.5097e-03 8.2722e-01 12 9 9 12 1 1 53.31 21.16 1.03 0.00361 -0.01344 201 114 1 2 0 100.980 15.00 21.16 23.00 21.79 21.58 12.1 1004.59 -1842 -1365 -2448 -2596 -3403 -2779 -1959 -1186 -917 -1191 -1232 -1270 -1792 -1993 -1092 -1743 -1431 -1614 -1128 -1379 -1399 -1389 -2055 -2453 -2648 -2413 -2000 -1516 -1262 -379 -197 -676 -889 -1713 -1770 -1736 -1013 -604 125 400 181 241 244 93 229 187 10 530 657 921 1121 1436 1371 773 1409 954 1465 1656 1878 1547 1729 1760 2091 2635 2294 2119 1856 2153 2090 2628 2348 2543 2883 2568 2578 2550 2700 2284 2443 1946 2158 2181 2172 2492 1656 1748 1407 1504 1613 1787 1831 1734 1855 1479 1656 1644 1854 1351 1662 1686 1986 1721 1724 1437 1140 1103 1040 1184 1075 1055 747 621 556 678 528 280 400 43 -266 -376 -147 -173 -430 -465 -338 -296 -444 -595 -777 -590 -526 -458 -615 -401 -451 -506 -588 -813 -778 -966 -703 -699 -670 -947 -1004 -681 -802 -757 -990 -849 -1105 -861 -1225 -1110 -1020 -1149 -1011 -1073 -974 -1112 -950 -1090 -926 -907 -890 -1032 -1099 -1100 -1344 -1224 -1319 -1084 -1098 -1335 -1363 -1202 -1035 -961 -896 -1047 -1079 -1095 -909 -841 -662 -693 -746 -753 -752 -769 -1092 -818 -955 -865 -732 -831 -885 -866 -659 -748 -759 -751 -569 -547 -502 -440 -559 -532 -652 -616 -639 -443 -469 -47 -220 -258 -239 -256 -413 -486 -473 -619 -528 -659 -706 -601 -777 -862 -1148 -1415 -1650 -1365 -1665 -1681 -1710 -1555 -1660 -1131 -800 -401 -109 228 353 274 274 159 43 8 -75 -218 -114 84 277 431 309 352 270 -35 -320 -367 -403 -475 -333 -86 198 306 428 350 349 375 342 501 523 737 764 819 822 1015 1060 1136 1027 1037 1012 928 928 978 1070 1093 1277 1105 1021 940 775 878 504 659 526 1002 1009 1010 1106 1240 1206 1127 973 1066 1082 889 779 723 719 768 795 854 777 721 672 691 749 589 480 496 445 473 376 128 81 108 215 87 40 -22 -15 -19 80 -32 -111 -127 -75 -69 -147 -213 -80 -79 -19 -160 -381 -562 -487 -553 -649 -738 -781 -698 -691 -633 -672 -559 -595 -478 -442 -422 -340 -464 -285 -304 -175 -394 -334 -288 -197 -290 -228 -271 -338 -171 -233 -258 -307 -195 -185 -179 -252 -154 -140 -51 15 -21 -74 33 98 52 62 54 -77 14 -69 -8 -20 48 -45 -75 -82 -80 -119 -115 -17 -185 -111 -196 -165 60 22 3 11 33 71 99 23 99 180 199 280 237 341 266 215 292 267 185 238 141 169 175 161 220 166 65 -33 54 26 80 63 167 110 91 110 235 195 155 111 193 188 37 -37 -123 -138 -93 -28 -41 -51 -39 -72 -23 -61 -19 92 92 102 -17 -26 -39 -48 22 -13 -50 -115 -92 -88 -148 -149 -204 -227 -158 -106 -45 -13 -59 -35 -42 -98 -96 -47 -45 -57 -119 -203 -259 -264 -214 -134 -42 -97 -143 -254 -244 -253 -273 -220 -289 -386 -389 -388 -355 -250 -189 5 168 178 102 -47 -60 -69 -42 -96 -26 111 154 167 121 78 62 116 110 214 267 328 333 313 318 306 388 377 -719 -533 -952 -1003 -1313 -1074 -766 -470 -366 -479 -497 -512 -726 -811 -444 -716 -589 -666 -466 -574 -625 -616 -901 -1059 -1132 -1038 -877 -679 -574 -173 -90 -305 -391 -741 -758 -750 -449 -275 57 183 82 108 109 42 103 84 5 236 290 409 511 662 635 360 655 443 678 762 862 719 819 846 1010 1273 1117 1048 935 1095 1065 1330 1179 1261 1413 1335 1308 1262 1318 1120 1226 1015 1159 1109 1116 1291 872 936 767 825 884 977 996 943 1016 816 912 904 1016 738 896 901 1058 926 949 815 663 647 603 673 606 593 427 362 328 400 311 164 233 25 -157 -225 -90 -108 -272 -297 -216 -188 -281 -375 -485 -364 -321 -277 -373 -246 -281 -319 -372 -517 -497 -617 -446 -415 -400 -570 -618 -428 -507 -476 -613 -514 -662 -512 -736 -681 -639 -740 -667 -718 -656 -757 -650 -745 -628 -610 -596 -697 -758 -767 -932 -823 -838 -663 -673 -848 -918 -792 -691 -633 -579 -671 -689 -710 -599 -563 -452 -478 -513 -513 -501 -507 -728 -550 -652 -603 -514 -581 -612 -594 -453 -524 -553 -531 -404 -407 -360 -302 -372 -347 -433 -427 -461 -307 -330 -33 -154 -180 -167 -178 -283 -347 -338 -421 -364 -464 -500 -415 -545 -577 -740 -892 -1044 -874 -1069 -1066 -1069 -966 -1049 -751 -538 -293 -82 181 291 228 224 124 32 6 -56 -168 -88 68 232 364 262 293 218 -27 -242 -268 -296 -344 -257 -70 167 249 346 293 289 307 282 405 432 616 650 704 719 907 954 1018 919 919 890 816 807 840 917 944 1120 941 868 803 624 683 391 525 440 862 880 844 929 1057 1050 997 868 953 965 778 667 620 618 667 718 766 720 678 628 637 685 545 458 484 417 441 362 123 74 100 199 81 37 -20 -13 -17 74 -31 -108 -123 -72 -66 -140 -206 -79 -75 -18 -153 -362 -546 -463 -516 -600 -686 -735 -664 -672 -601 -652 -552 -591 -475 -441 -427 -350 -488 -303 -326 -186 -412 -342 -290 -198 -299 -243 -283 -354 -186 -251 -279 -334 -214 -196 -192 -273 -169 -155 -57 17 -24 -86 39 115 62 73 64 -90 16 -79 -9 -23 57 -52 -88 -95 -95 -138 -131 -19 -208 -126 -225 -191 71 26 4 14 43 91 127 29 126 228 248 345 293 423 332 271 372 345 244 319 194 233 239 219 297 225 90 -45 75 36 111 88 235 155 127 152 334 274 216 155 273 270 54 -55 -183 -206 -138 -42 -61 -76 -58 -107 -35 -91 -28 139 141 158 -27 -40 -59 -73 33 -21 -76 -177 -142 -137 -233 -236 -324 -361 -252 -169 -71 -21 -94 -56 -67 -157 -153 -74 -70 -91 -190 -328 -421 -426 -341 -211 -66 -154 -232 -421 -407 -423 -458 -373 -476 -647 -656 -651 -587 -420 -308 7 265 283 167 -79 -98 -114 -70 -161 -43 184 254 276 202 133 107 200 189 369 459 564 576 525 537 514 645 645 SQ 20230111T135333.2Z 8411.578856 220 1 48.36 2 86.70 118.62 57.56 261.85 0.00 1 0.00 1 0 65 6.351e-03 3.481e-03 8.032e-04 5.270e-04 6.195550e+03 1.136621e+02 4.526974e+02 3.864661e+02 1.288196e+03 282.68 -2.00 20.00 -2.00 453.22 0.00e+00 2.897853e-04 7.162569e-05 3.803414e-06 2.327848e-05 6.826698e-04 282.68 -2.00 20.00 -2.00 460.18 0.00e+00 1.483331e-03 5.001298e-06 1.006264e-05 1.406325e-05 5.813095e-05 226.09 -2.00 2.08 -2.00 449.67 0.00e+00 5.981367e+06 7.794852e+04 6.740234e+04 2.343602e+05 9.278276e+05 263.86 -2.00 10.73 -2.00 462.01 0.00e+00 1.330904e+00 1.197328e-02 9.822824e-03 8.148887e-03 1.977382e-01 224.31 -2.00 3.32 -2.00 459.54 0.00e+00 -2.895072e-05 1.570646e-06 1.014983e-06 1.200665e-06 2.426851e-05 282.68 -2.00 20.00 -2.00 459.83 0.00e+00 12.868 0.030 397.00 473.00 4 3.3012e+00 6.6756e-04 3.3659e-02 4.1850e-04 6.7314e-03 -8.5516e-02 9.3514e-04 7.0319e-03 3.9204e-04 9.3655e-03 5.9064e-02 4.3612e-04 9.2665e-04 1.2758e-04 4.0282e-03 2.3541e-02 1.9337e-04 1.2158e-04 3.6416e-05 1.5546e-03 -2.7589e-02 9.2360e-05 6.3029e-05 1.8300e-05 7.7814e-04 3.7309e-03 -1.5995e-01 2.4967e-04 8.3707e-05 9.5303e-05 3.8853e-03 -1.4276e-04 6.8213e-06 1.4570e-06 3.6127e-07 6.7066e-05 5.5291e-05 9.0547e-06 2.0276e-06 4.8412e-07 9.5436e-05 4.9494e-04 1.2350e-05 4.2114e-01 5.7539e-02 4.3838e-03 4.2822e-03 5.5830e-01 12 8 8 10 0 0 98.71 21.17 0.91 0.00049 -0.00734 197 47 1 2 0 245.400 15.00 21.17 23.60 21.79 21.58 11.7 1005.37 -1308 -1302 -1895 -1564 -1959 -2136 -1130 -1109 -882 -937 -818 -1287 -991 -1282 -1183 -1049 -1013 -957 -1262 -1022 -1173 -1009 -1687 -998 -1725 -1923 -1324 -1157 -664 -1376 -406 -743 -599 -1132 -502 -855 -902 -303 -234 218 -16 354 -194 497 251 466 310 147 642 540 770 754 1148 555 1093 920 1238 1287 1502 1412 1174 1044 1155 1621 1463 1459 1137 996 1170 1282 1462 1333 1539 1488 2119 2071 2090 1957 1517 1451 1344 1599 1356 1516 985 1100 730 841 948 899 1277 882 1265 991 1252 944 1355 866 936 1362 1082 1578 906 1043 598 817 652 861 702 614 540 385 669 452 456 206 263 145 -170 -189 -362 -314 -354 -627 -411 -256 -531 -450 -386 -488 -220 -539 -237 -254 -335 -432 -211 -514 -439 -374 -521 -616 -390 -475 -719 -424 -427 -602 -615 -345 -609 -528 -522 -566 -604 -745 -570 -570 -784 -688 -674 -594 -429 -550 -820 -609 -744 -734 -699 -745 -707 -598 -631 -883 -759 -804 -701 -591 -410 -623 -595 -613 -581 -493 -492 -434 -657 -491 -490 -444 -380 -451 -486 -578 -513 -561 -514 -679 -437 -548 -570 -487 -400 -327 -449 -180 -344 -281 -454 -206 -298 -270 -264 -120 -272 -146 -136 -180 -436 -415 -195 -570 -338 -445 -344 -313 -476 -151 -410 -521 -571 -571 -720 -645 -614 -1036 -590 -731 -291 -319 22 -3 159 -69 74 40 -85 -14 -209 -119 -170 -103 104 18 33 -21 -90 -357 -348 -694 -406 -631 -270 -96 -78 47 73 161 76 162 95 439 231 507 473 400 634 621 771 692 724 721 706 724 619 745 729 859 820 920 706 691 408 604 435 571 727 839 752 746 803 735 839 631 879 591 695 653 504 469 487 448 467 493 494 425 485 339 308 182 319 287 269 224 178 11 47 154 26 64 -56 -18 -102 46 -8 -26 -61 -62 -127 -191 -220 -276 -33 -94 -33 -111 -159 -244 -346 -364 -416 -389 -539 -250 -360 -343 -363 -299 -330 -287 -226 -369 -264 -292 -224 -161 -102 -254 -170 -317 -364 -319 -233 -101 -138 -163 -372 -254 -332 -273 -212 -240 -226 -169 -56 -131 -146 -96 -99 -92 -43 -23 -79 -68 -26 -27 -80 -13 -16 -86 -8 -112 36 -141 -14 -29 -14 -60 -35 -83 -57 20 40 -48 -28 -1 5 94 105 111 197 149 270 240 280 250 246 187 263 179 128 144 152 135 181 262 61 107 57 131 155 112 119 38 132 61 118 82 236 151 184 99 151 109 -36 -40 -82 31 -38 15 -68 -13 -41 5 28 -72 25 -14 79 44 -14 -95 -26 -43 -31 -40 -10 -43 -2 -26 -102 -91 -95 -102 -116 10 -34 -72 -29 13 -86 -55 21 14 55 -27 -135 -146 -210 -94 -128 -57 -130 -155 -135 -162 -186 -202 -211 -267 -316 -319 -271 -276 -154 -107 44 85 126 55 -16 -52 -28 -99 -76 -48 76 71 137 -4 89 114 80 90 127 148 165 236 214 254 226 209 254 -450 -449 -649 -530 -662 -726 -390 -389 -313 -335 -293 -462 -357 -464 -430 -384 -372 -352 -468 -381 -438 -373 -616 -355 -609 -686 -483 -434 -253 -533 -157 -282 -220 -406 -192 -331 -362 -116 -98 91 -7 144 -79 202 103 190 126 59 256 217 319 318 485 236 464 389 522 540 628 598 510 462 515 722 657 666 531 471 554 603 679 612 697 661 911 865 859 807 645 644 619 751 645 729 482 547 371 431 484 458 646 447 645 509 641 483 690 439 468 672 534 784 464 551 325 447 352 455 366 320 286 208 366 248 249 112 142 78 -93 -105 -205 -182 -209 -375 -246 -152 -313 -264 -223 -279 -124 -301 -132 -144 -193 -252 -124 -303 -259 -221 -306 -362 -231 -282 -439 -244 -247 -347 -348 -206 -359 -309 -309 -316 -345 -439 -344 -349 -485 -430 -423 -372 -266 -338 -503 -376 -469 -469 -443 -455 -406 -330 -348 -507 -464 -515 -455 -378 -256 -386 -367 -384 -371 -321 -327 -291 -440 -324 -316 -282 -244 -293 -320 -390 -348 -379 -343 -449 -289 -370 -373 -329 -271 -219 -288 -118 -219 -175 -288 -127 -192 -178 -176 -80 -181 -96 -90 -118 -282 -263 -123 -366 -219 -295 -230 -204 -295 -89 -231 -308 -338 -319 -402 -355 -358 -602 -323 -424 -182 -219 16 -2 123 -54 56 30 -62 -10 -145 -86 -122 -78 81 15 26 -17 -67 -252 -245 -472 -277 -452 -193 -72 -61 37 58 125 58 123 73 346 187 415 394 337 542 544 637 570 594 624 606 620 525 622 607 721 657 752 577 572 318 454 324 440 588 656 597 597 646 601 700 536 749 507 593 545 411 384 399 371 403 443 459 378 428 295 265 159 287 264 249 206 161 10 42 141 24 59 -51 -16 -91 41 -8 -24 -58 -60 -120 -179 -207 -248 -31 -87 -31 -102 -146 -220 -323 -332 -375 -353 -495 -232 -322 -314 -340 -285 -316 -275 -218 -360 -262 -296 -230 -166 -105 -257 -168 -308 -354 -317 -240 -106 -145 -170 -387 -264 -347 -287 -225 -256 -246 -186 -62 -147 -165 -111 -116 -108 -51 -27 -92 -80 -31 -31 -92 -14 -19 -101 -10 -131 41 -161 -16 -34 -16 -68 -40 -96 -67 23 48 -60 -35 -1 7 122 135 142 251 187 336 299 350 315 312 240 341 237 173 198 211 187 246 355 84 148 79 182 217 157 167 53 188 86 174 120 338 215 262 143 221 162 -54 -61 -125 47 -56 22 -102 -20 -61 8 43 -110 39 -22 125 70 -22 -154 -43 -70 -51 -65 -17 -70 -4 -43 -171 -153 -159 -171 -194 17 -57 -121 -48 21 -144 -92 35 23 91 -45 -229 -249 -357 -157 -212 -94 -217 -265 -235 -283 -325 -356 -374 -481 -544 -553 -467 -469 -271 -182 74 140 209 93 -27 -88 -48 -171 -131 -83 129 120 231 -6 155 200 141 159 223 261 291 417 381 456 403 370 444 SQ 20230111T135947.5Z 8411.583189 223 1 45.89 2 85.55 119.50 58.85 262.75 0.00 1 0.00 1 0 49 4.989e-03 3.305e-03 2.695e-03 1.977e-03 4.339762e+03 4.232594e+02 3.497396e+02 3.864690e+02 1.011263e+03 282.68 -2.00 20.00 -2.00 452.06 0.00e+00 9.224755e-04 2.592637e-04 8.734550e-06 2.107985e-05 5.351288e-04 282.68 -2.00 20.00 -2.00 459.64 0.00e+00 1.378223e-03 1.841558e-05 9.289293e-06 1.406616e-05 4.548162e-05 226.04 -2.00 2.08 -2.00 447.59 0.00e+00 3.666839e+06 2.878322e+05 6.190454e+04 2.343578e+05 7.265297e+05 263.86 -2.00 10.73 -2.00 461.50 0.00e+00 1.183333e+00 4.564232e-02 6.611767e-03 8.398003e-03 1.552475e-01 224.31 -2.00 3.32 -2.00 459.00 0.00e+00 -1.427869e-05 5.968118e-06 6.992001e-07 1.195882e-06 1.906619e-05 282.68 -2.00 20.00 -2.00 459.39 0.00e+00 10.678 0.017 397.00 473.00 4 6.2630e+00 2.4319e-03 2.7551e-02 4.1950e-04 5.2229e-03 -1.2824e-02 3.3088e-03 5.7561e-03 3.4042e-04 6.9378e-03 2.0644e-03 1.5927e-03 7.5871e-04 1.2924e-04 3.2793e-03 2.1258e-02 6.2036e-04 8.7860e-05 3.2799e-05 1.2107e-03 -1.8786e-02 3.1921e-04 2.9991e-05 1.7118e-05 6.0485e-04 3.0519e-04 -1.2656e-01 1.1083e-03 5.7957e-05 7.7676e-05 2.9993e-03 -1.4551e-04 2.4214e-05 1.0332e-06 3.5623e-07 5.2697e-05 1.4893e-04 3.2790e-05 1.2973e-06 4.5005e-07 7.5138e-05 1.0555e-02 -1.0765e-04 5.1048e-01 2.1696e-01 4.3603e-03 4.1109e-03 4.4495e-01 12 8 8 10 0 0 91.31 21.15 0.88 0.01056 -0.00530 13 4 1 2 0 3529.560 15.00 21.15 23.59 21.79 21.58 11.6 1005.08 -69 -1520 -2037 -1480 -366 63 -135 220 46 1377 -904 250 -359 -950 -1448 -1335 -231 340 470 307 -1125 -370 -302 58 -2142 -1894 -852 -222 71 376 590 -431 -998 -914 -466 -1144 -63 246 -935 574 900 521 -846 14 -840 -213 779 -2 783 44 338 428 1279 -192 -542 -516 108 499 608 1599 2194 264 428 -299 -657 572 352 598 614 1095 1130 183 875 177 611 1896 841 1819 505 257 1032 1250 522 1500 -379 409 -319 693 604 157 1209 1033 1471 331 551 1345 103 379 1030 416 447 987 226 359 104 -22 231 126 -28 617 371 580 -121 -96 394 -573 -283 -535 553 -778 -981 777 190 -42 -463 -562 -4 -500 -418 -527 -785 -650 754 -647 -409 -372 -1049 -705 -427 -527 -87 153 -163 -120 130 -88 -76 -617 -1344 -412 -576 -95 -1050 -232 -367 99 584 -622 -657 138 -549 344 109 306 -112 -362 -360 -1028 -714 -239 -223 -346 -470 327 -86 -134 -702 -223 -709 -718 -338 -231 -188 198 -352 394 -103 -268 134 -1042 537 -161 50 -162 -133 -90 490 -318 -634 -647 -354 -102 -156 -268 -281 1071 -334 172 -677 -443 -861 -678 -956 33 -316 452 322 -179 -76 -351 201 -516 -202 -447 -168 -445 449 -71 429 84 -698 -644 -890 -765 -483 -99 116 190 -95 -37 -269 143 -204 -24 338 58 327 -157 7 -112 -607 -268 -49 9 544 621 396 627 -114 -154 -547 -152 -97 -721 164 -68 138 190 90 -171 -257 103 80 211 83 95 777 411 820 489 213 745 285 122 -11 1065 240 588 681 445 611 98 100 371 320 42 563 24 386 -191 418 841 530 470 618 319 229 -269 245 921 474 598 -84 506 235 346 -58 -208 69 229 82 611 192 -353 450 -95 122 321 -130 57 115 -41 -440 -372 33 -222 13 -21 -108 154 194 -244 -325 278 -365 -164 13 -72 -193 -308 -221 -294 -34 -525 130 -150 -80 -145 132 91 -97 -46 186 -247 -119 -70 137 -164 -312 -239 -162 163 79 305 -234 -438 -199 -541 -283 -155 -127 -150 -356 -237 6 114 -432 -95 -441 -192 51 -210 -191 179 169 -230 162 -272 -258 -152 -155 -248 -132 -456 -232 -286 -105 -391 -60 -401 -62 105 118 284 -170 -93 52 -208 252 140 102 85 471 514 84 110 -128 359 29 124 -264 303 469 -103 528 91 35 17 353 295 -19 145 103 64 215 87 -24 -114 -106 353 212 24 164 165 -77 -2 42 -270 -119 255 -89 20 -202 -36 -96 281 385 12 -66 -209 -257 -179 -193 148 121 -160 -30 172 121 4 73 -321 75 -261 -50 201 -48 73 -235 100 -50 106 236 -224 255 -95 183 17 -152 -90 -228 -239 45 -177 -335 -140 -207 -185 42 -24 -243 -173 -173 -238 115 -26 98 32 108 140 205 -52 -99 -237 19 142 -34 46 220 6 -92 -151 37 160 -78 -10 104 319 -11 350 -163 215 146 -29 -641 -849 -607 -148 25 -56 93 20 593 -397 109 -157 -419 -645 -600 -103 152 211 139 -514 -166 -132 25 -907 -810 -373 -101 33 176 276 -198 -440 -389 -195 -487 -28 113 -440 266 410 234 -412 7 -414 -104 374 -1 367 21 167 216 642 -98 -277 -262 54 249 302 800 1124 140 229 -161 -357 314 198 341 351 618 627 100 470 93 309 914 400 861 250 134 559 693 295 851 -222 243 -195 423 367 95 722 617 884 201 334 808 62 226 601 241 257 572 136 223 67 -14 147 78 -17 373 228 365 -77 -61 250 -363 -178 -335 346 -501 -646 518 130 -29 -322 -386 -3 -338 -278 -345 -506 -414 475 -418 -269 -247 -703 -473 -287 -353 -58 102 -109 -80 83 -57 -50 -403 -863 -255 -380 -62 -643 -145 -235 65 394 -430 -458 97 -388 240 76 209 -77 -249 -253 -735 -504 -162 -141 -208 -283 204 -58 -94 -505 -157 -489 -489 -228 -158 -132 141 -257 289 -75 -194 94 -724 372 -113 36 -119 -98 -66 351 -226 -453 -473 -250 -74 -115 -193 -194 746 -226 114 -457 -314 -595 -480 -687 24 -224 317 225 -125 -52 -235 134 -348 -138 -313 -118 -304 288 -47 267 51 -426 -399 -552 -466 -288 -59 70 113 -61 -26 -210 119 -167 -19 270 48 247 -113 5 -84 -485 -212 -39 8 444 498 305 484 -82 -106 -381 -110 -76 -559 131 -56 112 151 70 -132 -201 83 66 176 70 82 677 368 736 438 190 655 249 107 -9 896 203 499 587 392 536 82 78 278 238 32 455 20 328 -165 360 732 443 399 527 273 195 -225 199 744 385 490 -72 452 218 325 -54 -192 63 209 78 590 176 -323 428 -90 110 289 -118 52 104 -36 -389 -329 29 -204 12 -20 -100 141 178 -228 -309 266 -350 -158 13 -67 -175 -274 -194 -260 -30 -475 120 -141 -77 -142 129 89 -96 -46 189 -257 -119 -70 136 -169 -315 -237 -160 164 83 325 -250 -465 -209 -572 -300 -166 -137 -162 -391 -264 7 129 -469 -104 -493 -216 57 -235 -214 211 196 -267 186 -314 -300 -178 -182 -291 -153 -522 -259 -311 -112 -418 -68 -436 -72 124 133 330 -203 -112 63 -253 304 178 129 106 580 635 105 137 -162 455 37 163 -355 412 641 -141 708 122 46 23 483 406 -26 200 142 90 301 121 -33 -164 -151 494 298 35 236 242 -115 -3 63 -402 -175 373 -131 30 -299 -53 -143 419 576 18 -101 -327 -406 -284 -306 233 191 -253 -47 275 194 7 118 -525 122 -426 -82 327 -78 119 -383 162 -82 171 379 -361 409 -154 300 28 -248 -145 -363 -380 71 -289 -559 -235 -348 -311 71 -42 -399 -286 -285 -411 194 -43 156 51 171 228 343 -88 -161 -388 31 230 -55 73 352 10 -151 -252 61 267 -129 -17 173 533 -19 592 -275 358 240