File name: Pandora207s2_ArlingtonTX_20221220_L2Fit_fnvs4c1d20220105p1-8.txt
File generation date: 20240212T211501.5Z
Data description: Level 2 spectral fitting results file
Data file version: fnvs4c1p1-8
Local principal investigator: Yang Li
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 207
Spectrometer number: 2
Processing software version used: BlickP v1.8.59
Instrument operation file used: Pandora207_OF_v5d20210722.txt
Instrument calibration file used: Pandora207s2_CF_v1d20220105.txt
Level 1 file used: Pandora207s2_ArlingtonTX_20221220_L1_smca1c1d20220105p1-8.txt
Full location name: University Of Texas, Arlington Science Hall
Short location name: ArlingtonTX
Country of location: United States
Location latitude [deg]: 32.7316
Location longitude [deg]: -97.1142
Location altitude [m]: 15
Local noon date: 20221220
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method)
Data caveats: None
First and last pixel inside fitting window: 43 284
Nominal wavelengths inside fitting window [nm]: 400.0814 400.3734 400.6653 400.9572 401.2491 401.5410 401.8328 402.1247 402.4165 402.7083 403.0001 403.2918 403.5836 403.8753 404.1670 404.4587 404.7504 405.0420 405.3336 405.6252 405.9168 406.2084 406.5000 406.7915 407.0830 407.3745 407.6660 407.9575 408.2489 408.5403 408.8317 409.1231 409.4145 409.7059 409.9972 410.2885 410.5798 410.8711 411.1623 411.4536 411.7448 412.0360 412.3272 412.6183 412.9095 413.2006 413.4917 413.7828 414.0738 414.3649 414.6559 414.9469 415.2379 415.5289 415.8199 416.1108 416.4017 416.6926 416.9835 417.2744 417.5652 417.8560 418.1468 418.4376 418.7284 419.0191 419.3098 419.6005 419.8912 420.1819 420.4726 420.7632 421.0538 421.3444 421.6350 421.9255 422.2161 422.5066 422.7971 423.0876 423.3780 423.6685 423.9589 424.2493 424.5397 424.8300 425.1204 425.4107 425.7010 425.9913 426.2816 426.5718 426.8621 427.1523 427.4425 427.7326 428.0228 428.3129 428.6030 428.8931 429.1832 429.4733 429.7633 430.0533 430.3433 430.6333 430.9233 431.2132 431.5031 431.7930 432.0829 432.3728 432.6626 432.9525 433.2423 433.5320 433.8218 434.1116 434.4013 434.6910 434.9807 435.2704 435.5600 435.8496 436.1393 436.4289 436.7184 437.0080 437.2975 437.5870 437.8765 438.1660 438.4555 438.7449 439.0343 439.3237 439.6131 439.9024 440.1918 440.4811 440.7704 441.0597 441.3489 441.6382 441.9274 442.2166 442.5058 442.7950 443.0841 443.3732 443.6623 443.9514 444.2405 444.5295 444.8186 445.1076 445.3965 445.6855 445.9745 446.2634 446.5523 446.8412 447.1300 447.4189 447.7077 447.9965 448.2853 448.5741 448.8628 449.1516 449.4403 449.7290 450.0176 450.3063 450.5949 450.8835 451.1721 451.4607 451.7492 452.0378 452.3263 452.6148 452.9032 453.1917 453.4801 453.7685 454.0569 454.3453 454.6337 454.9220 455.2103 455.4986 455.7869 456.0751 456.3633 456.6516 456.9398 457.2279 457.5161 457.8042 458.0923 458.3804 458.6685 458.9565 459.2446 459.5326 459.8206 460.1085 460.3965 460.6844 460.9723 461.2602 461.5481 461.8360 462.1238 462.4116 462.6994 462.9872 463.2749 463.5626 463.8503 464.1380 464.4257 464.7134 465.0010 465.2886 465.5762 465.8637 466.1513 466.4388 466.7263 467.0138 467.3013 467.5887 467.8762 468.1636 468.4510 468.7383 469.0257 469.3130 469.6003 469.8876
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Water vapor effective temperature [K]
Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Molecular iodine effective temperature [K]
Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Nitrogen dioxide effective temperature [K]
Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful
Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 60: Oxygen dimer effective temperature [K]
Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful
Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 71: Ozone effective temperature [K]
Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 82: Iodine dioxide effective temperature [K]
Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful
Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 90: Lower limit used for wavelength scaling [nm]
Column 91: Upper limit used for wavelength scaling [nm]
Column 92: Order of smoothing polynomial
Column 93: Smoothing polynomial coefficient, order 0
Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 98: Smoothing polynomial coefficient, order 1
Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 103: Smoothing polynomial coefficient, order 2
Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 108: Smoothing polynomial coefficient, order 3
Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 113: Smoothing polynomial coefficient, order 4
Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 118: Mean value of measured data inside fitting window [same units as measurements]
Column 119: Offset polynomial coefficient, order 0
Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 124: Wavelength change polynomial coefficient, order 0
Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 129: Wavelength change polynomial coefficient, order 1
Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 136: L1 based wavelength change coefficient, order 2, -9=no L1 wavelength change determination
Column 137: Resolution change polynomial coefficient, order 0
Column 138: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 139: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 140: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 141: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 142: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 144: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 145: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 147: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 148: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 149: Wavelength effective temperature [�C], 999=no effective temperature given
Column 150: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 151: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 152: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 153: Number of bright count cycles
Column 154: Number of dark count cycles
Column 155: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 156: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 157: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 158: Integration time [ms]
Column 159: Spectrometer control temperature [�C], 999=no temperature signal
Column 160: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Column 161: Temperature in head sensor [�C], 999=no temperature signal
Column 162: Temperature at electronics board 1 [�C], 999=no temperature signal
Column 163: Temperature at electronics board 2 [�C], 999=no temperature signal
Column 164: Humidity in head sensor [%], -9=no humidity signal
Column 165: Pressure in head sensor [hPa], -9=no pressure signal
Columns 166-407: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 408-649: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------