File name: Pandora119s1_Athens-NOA_20250322_L2Fit_ffus5c3d20201216p1-8.txt File generation date: 20250409T110547.1Z Data description: Level 2 spectral fitting results file Data file version: ffus5c3p1-8 Local principal investigator: Stelios Kazadsis Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 119 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora119_OF_v1d20201007.txt Instrument calibration file used: Pandora119s1_CF_v3d20201216.txt Level 1 file used: Pandora119s1_Athens-NOA_20250322_L1_smca1c3d20201216p1-8.txt Full location name: National Observatory of Athens, Thiseio Short location name: Athens-NOA Country of location: Greece Location latitude [deg]: 37.9878 Location longitude [deg]: 23.7750 Location altitude [m]: 130 Local noon date: 20250322 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 349 613 Nominal wavelengths inside fitting window [nm]: 322.5770 322.7169 322.8567 322.9966 323.1364 323.2763 323.4161 323.5559 323.6957 323.8355 323.9752 324.1150 324.2548 324.3945 324.5342 324.6739 324.8136 324.9533 325.0930 325.2327 325.3724 325.5120 325.6516 325.7913 325.9309 326.0705 326.2101 326.3496 326.4892 326.6288 326.7683 326.9078 327.0474 327.1869 327.3264 327.4658 327.6053 327.7448 327.8842 328.0237 328.1631 328.3025 328.4419 328.5813 328.7207 328.8600 328.9994 329.1387 329.2781 329.4174 329.5567 329.6960 329.8353 329.9745 330.1138 330.2530 330.3923 330.5315 330.6707 330.8099 330.9491 331.0883 331.2274 331.3666 331.5057 331.6449 331.7840 331.9231 332.0622 332.2012 332.3403 332.4794 332.6184 332.7574 332.8965 333.0355 333.1745 333.3135 333.4524 333.5914 333.7303 333.8693 334.0082 334.1471 334.2860 334.4249 334.5638 334.7026 334.8415 334.9803 335.1192 335.2580 335.3968 335.5356 335.6743 335.8131 335.9519 336.0906 336.2293 336.3681 336.5068 336.6455 336.7842 336.9228 337.0615 337.2001 337.3388 337.4774 337.6160 337.7546 337.8932 338.0318 338.1703 338.3089 338.4474 338.5860 338.7245 338.8630 339.0015 339.1399 339.2784 339.4169 339.5553 339.6937 339.8322 339.9706 340.1090 340.2473 340.3857 340.5241 340.6624 340.8008 340.9391 341.0774 341.2157 341.3540 341.4922 341.6305 341.7688 341.9070 342.0452 342.1834 342.3216 342.4598 342.5980 342.7362 342.8743 343.0125 343.1506 343.2887 343.4268 343.5649 343.7030 343.8411 343.9791 344.1172 344.2552 344.3932 344.5312 344.6692 344.8072 344.9452 345.0832 345.2211 345.3590 345.4970 345.6349 345.7728 345.9107 346.0485 346.1864 346.3243 346.4621 346.5999 346.7377 346.8755 347.0133 347.1511 347.2889 347.4266 347.5644 347.7021 347.8398 347.9775 348.1152 348.2529 348.3906 348.5282 348.6659 348.8035 348.9411 349.0787 349.2163 349.3539 349.4915 349.6290 349.7666 349.9041 350.0416 350.1791 350.3166 350.4541 350.5916 350.7290 350.8665 351.0039 351.1413 351.2788 351.4162 351.5535 351.6909 351.8283 351.9656 352.1029 352.2403 352.3776 352.5149 352.6522 352.7894 352.9267 353.0639 353.2012 353.3384 353.4756 353.6128 353.7500 353.8871 354.0243 354.1615 354.2986 354.4357 354.5728 354.7099 354.8470 354.9841 355.1211 355.2582 355.3952 355.5322 355.6692 355.8062 355.9432 356.0802 356.2171 356.3541 356.4910 356.6279 356.7648 356.9017 357.0386 357.1755 357.3123 357.4492 357.5860 357.7228 357.8596 357.9964 358.1332 358.2699 358.4067 358.5434 358.6802 358.8169 358.9536 359.0903 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-434: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 435-699: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20250322T081742.9Z 9212.345636 285 1 49.03 2 48.28 132.30 86.78 228.08 0.00 1 0.00 1 0 33 2.417e-03 2.252e-03 1.256e-03 1.157e-03 -1.824543e-07 3.853121e-07 3.738468e-08 4.499478e-07 7.757879e-07 226.96 -2.00 3.45 -2.00 340.57 0.00e+00 2.155118e-05 1.042638e-04 9.330112e-06 5.429721e-05 2.106127e-04 279.25 -2.00 20.00 -2.00 337.99 0.00e+00 -1.000461e-05 1.574324e-05 1.482422e-06 2.970090e-05 3.667305e-05 279.25 -2.00 20.00 -2.00 346.74 0.00e+00 4.556181e-04 4.535374e-05 2.404558e-05 4.264329e-05 1.027922e-04 279.25 -2.00 20.00 -2.00 345.31 0.00e+00 1.078541e+05 9.540618e+04 2.615955e+04 2.329111e+05 1.938160e+05 260.97 -2.00 11.07 -2.00 352.03 0.00e+00 2.491692e-01 1.481081e-03 2.009557e-03 2.413830e-03 2.518594e-03 226.96 -2.00 3.45 -2.00 330.66 0.00e+00 1.521034e-03 1.619375e-03 1.497680e-04 1.171281e-04 2.309545e-03 279.25 -2.00 20.00 -2.00 328.88 0.00e+00 1.500 0.000 319.50 362.20 4 5.2717e+00 1.4984e-03 1.0488e-02 1.7634e-03 3.3348e-03 1.1148e-02 3.7571e-04 1.6727e-03 3.6412e-04 7.6718e-04 4.4666e-03 7.4401e-04 4.0465e-04 1.8984e-04 1.5146e-03 -5.0830e-04 3.5209e-04 3.3620e-04 1.4431e-04 5.8568e-04 -7.6336e-04 5.7445e-04 2.3571e-04 1.1872e-04 1.0806e-03 1.2228e-03 -4.6388e-03 9.2295e-04 1.4326e-04 9.2306e-05 1.9123e-03 4.6669e-05 1.5390e-05 2.2569e-06 1.0937e-06 3.3370e-05 1.6115e-02 1.5277e-04 -8.9540e-01 1.0025e-01 1.1233e-02 6.3849e-03 2.0918e-01 12 8 8 10 0 0 99.50 23.13 0.32 0.01612 0.01669 15 3 1 5 0 3268.352 27.99 20.05 23.13 25.72 35.2 966.88 -189 -102 367 351 642 -323 113 411 73 337 -483 -36 -203 -45 257 -159 188 -42 -421 -173 -146 -22 -100 -224 110 332 2 88 -108 -199 -71 -420 171 7 -86 187 -221 57 100 123 19 286 157 28 -316 -53 -75 -288 324 50 -219 4 -55 268 157 -131 111 -21 -307 177 -412 64 -80 -104 29 -403 97 -45 108 253 -257 218 -251 1848 -264 -18 -73 -250 141 -12 68 -104 -46 97 -253 914 38 460 -307 109 -393 -350 -97 -26 357 -171 -310 -176 -373 -44 -249 -41 -30 402 104 126 -194 21 -206 -138 246 212 94 -226 -125 44 -60 178 7 -123 -4 -142 -170 171 -204 175 349 21 238 170 -3 -24 -84 3 -119 -92 -265 228 -240 -76 165 -131 -250 -43 -48 302 -183 -121 143 -12 15 71 -183 53 -204 349 678 -208 99 -103 97 -316 44 -201 -60 51 -148 283 -306 105 -75 144 81 179 -26 -220 157 -22 39 165 -312 110 -72 -111 -235 64 37 -79 163 305 -268 127 48 -26 328 -41 49 238 55 58 6 -68 -221 289 8 -236 238 -240 -53 -43 47 -54 -107 -108 -130 -104 -211 204 -42 45 98 -33 173 51 370 -66 40 -160 -40 70 88 243 16 53 -56 -273 110 -8 -100 -195 -324 -19 157 -268 114 27 13 178 -274 232 371 -99 175 124 -93 -200 -192 -604 -153 -11 -269 249 104 112 247 -92 -47 169 174 334 -178 62 228 42 207 -307 -23 -135 -30 167 -99 115 -25 -264 -113 -101 -16 -79 -183 92 275 2 72 -90 -166 -60 -353 141 5 -70 154 -180 45 78 95 15 227 123 22 -255 -44 -67 -272 309 48 -215 4 -55 267 151 -122 99 -17 -261 153 -364 57 -71 -91 26 -370 91 -42 99 226 -233 202 -237 1703 -245 -17 -69 -229 124 -10 58 -91 -42 91 -243 899 38 440 -290 103 -382 -355 -102 -27 350 -151 -246 -137 -306 -40 -236 -38 -26 326 82 104 -172 21 -207 -135 231 195 87 -222 -128 46 -62 187 7 -120 -4 -138 -174 187 -232 197 397 23 255 180 -3 -25 -88 3 -121 -91 -259 229 -259 -84 183 -144 -268 -46 -52 333 -210 -140 162 -13 17 77 -195 51 -178 288 546 -179 91 -102 104 -351 50 -224 -67 57 -163 298 -309 104 -77 154 89 202 -29 -256 183 -24 41 164 -304 112 -77 -125 -264 69 40 -88 180 334 -285 130 50 -27 339 -43 55 275 68 74 8 -85 -273 351 10 -277 266 -265 -59 -50 57 -67 -130 -124 -139 -105 -211 212 -48 53 120 -40 211 63 463 -84 51 -204 -52 90 112 316 21 69 -73 -344 135 -9 -121 -234 -394 -23 194 -331 135 29 14 175 -270 228 377 -106 196 141 -101 -203 -178 -530 -131 -9 -231 218 100 120 282 SS 20250322T082333.5Z 9212.349694 288 1 49.85 2 47.44 133.91 87.61 228.99 0.00 1 0.00 1 0 33 1.406e-03 1.336e-03 1.036e-03 9.608e-04 -2.340836e-07 3.193327e-07 3.785456e-08 4.499578e-07 4.512020e-07 226.96 -2.00 3.45 -2.00 340.46 0.00e+00 1.750102e-04 8.634178e-05 1.082468e-05 5.429479e-05 1.223238e-04 279.25 -2.00 20.00 -2.00 337.85 0.00e+00 5.929250e-06 1.313636e-05 2.003611e-06 2.970072e-05 2.133396e-05 279.25 -2.00 20.00 -2.00 346.62 0.00e+00 6.018623e-04 3.766840e-05 2.970620e-05 4.265375e-05 5.977489e-05 279.25 -2.00 20.00 -2.00 345.21 0.00e+00 -1.019417e+04 7.894163e+04 2.658631e+04 2.329165e+05 1.127335e+05 260.97 -2.00 11.07 -2.00 352.03 0.00e+00 2.470192e-01 1.214653e-03 2.032480e-03 2.414838e-03 1.464103e-03 226.96 -2.00 3.45 -2.00 330.58 0.00e+00 3.139278e-03 1.326578e-03 1.538261e-04 1.173187e-04 1.345709e-03 279.25 -2.00 20.00 -2.00 328.78 0.00e+00 1.476 0.000 319.50 362.20 4 5.0273e+00 1.2437e-03 1.0345e-02 1.7632e-03 1.9390e-03 7.6091e-03 3.1083e-04 1.6507e-03 3.6372e-04 4.4644e-04 3.2631e-03 6.1617e-04 4.2755e-04 1.8909e-04 8.8157e-04 3.1549e-05 2.8886e-04 3.3456e-04 1.4450e-04 3.4041e-04 -2.3050e-04 4.7376e-04 2.3874e-04 1.1891e-04 6.2842e-04 1.5837e-03 -5.1438e-03 7.6492e-04 1.6498e-04 9.5707e-05 1.1146e-03 -4.0532e-05 1.2764e-05 2.2537e-06 1.1015e-06 1.9402e-05 1.5510e-02 5.9890e-05 -9.5753e-01 8.3258e-02 1.2333e-02 6.6236e-03 1.2191e-01 12 8 8 10 0 0 66.62 23.30 0.19 0.01551 0.01501 18 4 1 5 0 2768.977 28.10 20.05 23.30 25.75 35.2 967.07 -51 276 130 296 316 122 280 -144 62 13 -123 -256 -428 236 31 4 121 17 -282 -516 -98 61 105 40 61 127 -24 89 -247 21 -128 -101 135 -62 -137 88 24 -80 -19 83 165 -214 43 88 103 198 -138 77 100 101 -35 182 -43 -7 -145 -257 58 -225 -216 51 -12 22 -237 -72 70 30 183 8 202 -51 -29 62 -231 82 106 0 42 36 -26 -61 -163 10 -110 62 24 347 17 298 122 -38 -53 -81 32 -38 84 68 -270 60 -14 -186 60 27 -14 -13 67 -94 31 56 -150 133 96 93 105 14 -325 94 24 -126 -79 -119 -18 -102 33 180 26 128 244 106 200 124 44 -48 -302 -196 -184 -144 -126 228 -143 -79 28 -157 -113 -33 106 196 39 -8 -5 -164 -47 100 -75 116 263 140 151 11 34 -165 128 6 15 -196 -108 -51 -166 -74 124 63 -77 245 -98 27 43 -169 -22 69 -39 -5 -79 -34 1 -129 55 -146 -196 -120 97 383 -250 163 69 -71 94 -29 73 156 -124 -90 124 29 -28 184 -116 -129 290 -122 -101 11 95 92 63 -42 146 15 4 -14 -70 -125 -60 23 -105 57 182 -48 15 64 -16 202 -49 200 -22 -49 132 -81 -22 -2 -134 -103 -326 27 33 -220 86 -81 22 147 -187 38 141 77 80 157 113 -107 -104 -299 -46 -12 -171 107 193 -95 82 -25 131 62 149 171 68 159 -83 37 8 -79 -169 -289 160 20 2 75 11 -180 -345 -70 45 82 33 51 108 -20 73 -206 18 -111 -87 112 -52 -115 74 20 -64 -15 65 132 -171 35 70 83 166 -124 73 96 98 -35 181 -44 -7 -140 -241 51 -191 -187 44 -11 20 -211 -64 63 27 174 8 186 -47 -26 57 -218 77 98 0 39 33 -23 -53 -141 9 -102 59 23 345 17 287 116 -36 -52 -83 33 -40 83 61 -218 47 -12 -171 57 25 -12 -11 54 -78 28 54 -152 130 92 86 98 14 -333 97 25 -130 -80 -116 -17 -99 34 194 29 146 274 117 212 129 46 -50 -317 -204 -184 -142 -123 230 -155 -89 32 -171 -122 -35 114 218 44 -9 -5 -182 -51 108 -79 114 233 115 124 10 32 -166 135 6 16 -221 -122 -57 -181 -78 125 63 -79 259 -108 30 48 -195 -26 78 -41 -5 -77 -34 1 -142 61 -161 -214 -132 108 421 -266 168 71 -74 98 -31 80 182 -153 -115 157 36 -34 222 -139 -150 322 -133 -112 13 115 112 76 -48 157 15 4 -15 -78 -146 -72 28 -128 71 227 -60 18 80 -20 254 -63 254 -28 -62 167 -102 -27 -2 -161 -122 -395 33 41 -271 101 -89 23 146 -185 37 142 82 89 178 124 -110 -97 -262 -40 -10 -147 96 187 -101 94 SS 20250322T083004.5Z 9212.354219 291 1 47.96 2 46.53 135.76 88.56 230.00 0.00 1 0.00 1 0 33 1.492e-03 1.401e-03 9.021e-04 8.414e-04 3.893105e-08 2.784315e-07 3.688355e-08 4.499802e-07 4.787748e-07 226.96 -2.00 3.45 -2.00 340.35 0.00e+00 6.820376e-05 7.526761e-05 9.015123e-06 5.429427e-05 1.296743e-04 279.25 -2.00 20.00 -2.00 337.75 0.00e+00 7.442213e-06 1.151154e-05 1.701785e-06 2.970084e-05 2.266438e-05 279.25 -2.00 20.00 -2.00 346.54 0.00e+00 5.222091e-04 3.306974e-05 2.682114e-05 4.265423e-05 6.343592e-05 279.25 -2.00 20.00 -2.00 345.11 0.00e+00 -2.407507e+04 6.889471e+04 2.639181e+04 2.329198e+05 1.195150e+05 260.97 -2.00 11.07 -2.00 351.99 0.00e+00 2.430447e-01 1.051096e-03 1.993262e-03 2.415264e-03 1.551355e-03 226.96 -2.00 3.45 -2.00 330.49 0.00e+00 1.731262e-03 1.139514e-03 1.498534e-04 1.178372e-04 1.425553e-03 279.25 -2.00 20.00 -2.00 328.67 0.00e+00 1.451 0.000 319.50 362.20 4 4.7971e+00 1.0915e-03 1.0159e-02 1.7631e-03 2.0565e-03 1.1854e-02 2.7069e-04 1.6213e-03 3.6378e-04 4.7285e-04 3.3285e-03 5.3736e-04 4.0700e-04 1.8812e-04 9.3405e-04 -2.0888e-04 2.4997e-04 3.2963e-04 1.4482e-04 3.6070e-04 -1.3940e-04 4.1172e-04 2.3422e-04 1.1908e-04 6.6521e-04 2.0300e-03 -4.4826e-03 6.7151e-04 1.5687e-04 9.6374e-05 1.1840e-03 4.0090e-06 1.1166e-05 2.2422e-06 1.1141e-06 2.0595e-05 1.4744e-02 1.0164e-04 -9.6063e-01 7.3055e-02 1.2007e-02 6.7067e-03 1.2956e-01 12 8 8 10 0 0 99.47 23.46 0.24 0.01474 0.01479 24 6 1 5 0 1997.987 28.29 20.04 23.46 25.85 35.2 967.87 -60 315 234 330 449 432 -32 -40 -221 203 -305 -56 -244 -63 -53 -51 -237 63 -76 -170 -154 -39 -180 -59 104 99 -57 98 -50 88 -45 -105 4 0 -35 99 -47 50 70 14 94 -15 121 102 125 -67 -51 52 98 -155 -62 168 -118 -67 68 -178 16 -110 -242 107 -178 -39 -78 -70 -39 49 120 -188 138 -124 -180 200 89 910 -55 -41 -46 -164 -111 -50 -3 -160 50 106 -68 483 81 378 -2 -79 -7 -140 -130 78 -44 -103 -133 -10 -134 -195 71 46 -136 -65 187 -43 -117 38 -48 59 115 151 128 -59 -32 99 8 -113 39 84 -127 -10 -160 -83 37 244 77 42 70 280 95 -32 -11 -309 -23 -186 -121 258 -305 -63 109 -81 -56 42 128 56 -123 -60 -21 43 55 132 -148 199 105 -21 224 -190 -54 -174 43 -191 197 -86 62 -85 4 -48 -37 -127 -177 -192 -61 63 46 -192 170 -4 -160 15 -14 -151 -103 48 66 -112 -95 -41 112 335 -294 102 79 -62 239 54 31 137 5 -80 -24 138 -43 216 109 -104 162 69 -32 6 26 -73 49 -206 96 -40 -188 110 82 24 55 10 -41 45 198 -143 49 -46 82 -9 53 105 24 -44 18 -59 -24 6 -69 -15 -116 -113 -163 -264 137 -113 -59 129 -188 235 143 150 33 65 41 -82 -61 -315 -34 -89 -142 230 89 80 43 -31 156 113 172 245 248 -19 -23 -134 130 -202 -38 -168 -44 -36 -33 -152 39 -49 -115 -111 -29 -143 -48 87 85 -48 81 -42 75 -39 -91 3 0 -30 84 -40 40 56 12 76 -12 98 82 101 -57 -46 49 96 -153 -61 166 -119 -67 67 -167 15 -95 -212 93 -161 -36 -70 -62 -35 45 114 -181 128 -114 -167 185 84 850 -51 -39 -43 -151 -99 -43 -2 -142 46 100 -67 478 81 369 -2 -76 -6 -142 -138 82 -44 -93 -108 -7 -113 -179 67 43 -118 -54 152 -35 -106 37 -48 59 110 140 119 -57 -33 103 8 -119 39 82 -124 -9 -164 -91 42 274 86 46 75 294 98 -32 -11 -321 -23 -183 -118 263 -328 -70 120 -89 -60 45 136 61 -141 -69 -23 47 60 142 -158 196 94 -17 182 -164 -50 -173 46 -210 220 -95 68 -96 5 -50 -37 -126 -184 -205 -66 69 51 -221 197 -4 -170 15 -13 -154 -110 53 73 -121 -103 -45 123 364 -311 104 81 -64 246 57 34 156 6 -101 -30 170 -53 260 127 -120 180 75 -35 6 32 -89 59 -234 102 -40 -190 116 92 27 66 12 -49 55 244 -180 62 -58 103 -12 67 134 31 -56 23 -74 -28 8 -82 -18 -139 -137 -200 -321 160 -123 -61 126 -183 232 143 161 37 73 45 -83 -57 -279 -29 -75 -123 203 85 85 49 SS 20250322T083643.1Z 9212.358832 294 1 49.15 2 45.63 137.70 89.53 231.01 0.00 1 0.00 1 0 33 1.908e-03 1.787e-03 1.183e-03 1.099e-03 6.474237e-08 3.645485e-07 3.703575e-08 4.499684e-07 6.122141e-07 226.97 -2.00 3.45 -2.00 340.39 0.00e+00 1.322514e-04 9.844735e-05 9.245805e-06 5.430062e-05 1.657972e-04 279.25 -2.00 20.00 -2.00 337.79 0.00e+00 1.711137e-05 1.501969e-05 1.745918e-06 2.970069e-05 2.898781e-05 279.25 -2.00 20.00 -2.00 346.60 0.00e+00 4.928827e-04 4.314209e-05 2.411647e-05 4.265065e-05 8.112561e-05 279.25 -2.00 20.00 -2.00 345.16 0.00e+00 -1.939584e+05 9.021155e+04 2.599559e+04 2.329141e+05 1.528465e+05 260.98 -2.00 11.07 -2.00 352.02 0.00e+00 2.407373e-01 1.380999e-03 1.975750e-03 2.414629e-03 1.980949e-03 226.97 -2.00 3.45 -2.00 330.54 0.00e+00 5.556450e-04 1.501112e-03 1.366746e-04 1.170095e-04 1.820102e-03 279.25 -2.00 20.00 -2.00 328.73 0.00e+00 1.428 0.000 319.50 362.20 4 5.2769e+00 1.4253e-03 9.9896e-03 1.7633e-03 2.6363e-03 1.1812e-02 3.5345e-04 1.5954e-03 3.6407e-04 6.0423e-04 9.6357e-04 7.0386e-04 3.9863e-04 1.8929e-04 1.1958e-03 -1.1148e-03 3.2849e-04 3.2629e-04 1.4463e-04 4.6130e-04 8.8234e-04 5.4017e-04 2.2801e-04 1.1870e-04 8.5109e-04 1.2818e-03 -6.4531e-03 8.7578e-04 1.5058e-04 9.4856e-05 1.5201e-03 -1.5396e-05 1.4603e-05 2.2280e-06 1.1099e-06 2.6338e-05 1.3501e-02 1.1548e-04 -8.6635e-01 9.5407e-02 1.1347e-02 6.5393e-03 1.6586e-01 12 9 8 11 8 0 98.72 23.60 0.14 0.01350 0.01331 14 3 1 5 0 3508.552 28.40 20.04 23.60 25.90 35.2 967.76 360 -384 443 424 134 376 37 540 -248 169 -522 128 -214 -216 521 -302 118 -251 -160 -305 -246 -157 -52 -151 293 290 -233 105 -212 -122 -77 -124 89 59 106 20 95 -8 -150 17 141 158 110 -54 118 60 -164 -354 208 -32 36 19 -89 82 205 -217 -171 -90 -174 -16 -196 11 118 -125 -39 163 10 38 236 35 -54 365 -293 235 -108 28 -76 -281 2 -165 -13 95 122 34 -100 480 172 408 -78 -7 -115 8 -14 -9 -51 -172 204 52 110 -130 -91 246 -8 135 -98 3 -234 -14 -284 -41 117 -68 351 37 -267 -58 -76 9 152 -39 58 -167 -162 169 -160 295 140 42 99 190 178 -44 -170 -132 -164 -212 -319 613 -350 -70 -64 -236 -206 107 301 216 138 -4 70 -223 112 167 -176 298 239 194 158 -159 -148 -158 1 -191 14 70 -52 -17 119 57 -248 50 -143 -37 -117 -75 -29 -224 260 -67 -158 144 -170 44 -53 -49 -181 31 24 -137 -4 586 -349 -166 201 -47 126 3 -39 261 67 -213 159 139 -235 1 -84 -211 289 -34 77 -70 54 -41 125 -40 -178 41 10 121 -30 21 19 -97 105 20 285 -365 106 -139 105 281 -96 128 20 93 -24 42 76 -52 -180 -179 -157 -20 34 -146 153 -84 -87 -6 -100 79 175 212 298 166 236 -244 -142 -423 -43 -334 -196 229 109 -83 -6 182 -185 211 218 73 209 21 310 -149 106 -344 84 -144 -147 349 -196 73 -157 -101 -207 -178 -119 -41 -126 248 244 -199 87 -179 -105 -67 -106 75 49 88 16 79 -7 -118 13 112 128 87 -43 96 51 -149 -339 201 -31 35 19 -89 82 201 -205 -151 -77 -150 -14 -175 10 106 -112 -35 150 9 36 220 32 -50 339 -280 222 -101 26 -72 -260 2 -144 -11 84 111 32 -96 478 173 394 -75 -6 -113 8 -14 -9 -50 -154 165 40 92 -119 -87 230 -7 111 -79 3 -212 -13 -288 -40 110 -63 326 36 -274 -60 -79 10 153 -39 55 -163 -167 182 -180 336 158 46 105 197 185 -46 -178 -138 -165 -210 -313 613 -380 -78 -72 -257 -222 112 322 240 156 -4 79 -248 123 182 -185 288 212 160 127 -136 -136 -157 1 -209 16 78 -58 -19 131 60 -251 49 -146 -39 -128 -84 -33 -257 299 -75 -168 143 -165 45 -56 -54 -199 33 26 -151 -4 640 -371 -171 206 -48 131 3 -43 301 82 -269 199 172 -291 1 -100 -244 325 -37 85 -81 65 -50 150 -46 -191 41 10 126 -34 24 22 -117 127 25 351 -462 133 -175 133 355 -121 164 25 120 -31 52 92 -62 -214 -215 -189 -24 42 -178 178 -94 -90 -6 -98 77 178 226 335 186 256 -248 -132 -370 -37 -283 -168 204 104 -89 -7 SS 20250322T091246.0Z 9212.383866 307 1 49.18 2 41.38 149.27 95.03 236.27 0.00 1 0.00 1 0 33 2.180e-03 2.139e-03 1.528e-03 1.424e-03 -3.416548e-07 4.696804e-07 3.389439e-08 4.500139e-07 6.989078e-07 226.97 -2.00 3.45 -2.00 340.18 0.00e+00 1.269818e-04 1.261280e-04 1.104230e-05 5.427833e-05 1.879790e-04 279.26 -2.00 20.00 -2.00 337.57 0.00e+00 -6.430259e-05 1.965261e-05 9.742705e-07 2.970076e-05 3.338035e-05 279.26 -2.00 20.00 -2.00 346.41 0.00e+00 3.374902e-04 5.619166e-05 2.090492e-05 4.264913e-05 9.267239e-05 279.26 -2.00 20.00 -2.00 344.92 0.00e+00 -6.959200e+04 1.162639e+05 2.482640e+04 2.329182e+05 1.736074e+05 260.98 -2.00 11.07 -2.00 351.79 0.00e+00 2.233765e-01 1.752909e-03 1.805605e-03 2.413421e-03 2.245707e-03 226.97 -2.00 3.45 -2.00 330.46 0.00e+00 5.411637e-03 1.912807e-03 1.456570e-04 1.165887e-04 2.067863e-03 279.26 -2.00 20.00 -2.00 328.64 0.00e+00 1.331 0.000 319.50 362.20 4 5.7324e+00 1.8466e-03 9.3047e-03 1.7633e-03 3.0035e-03 3.4873e-02 4.5175e-04 1.4861e-03 3.6469e-04 6.8519e-04 3.8206e-03 9.0053e-04 3.5376e-04 1.8611e-04 1.3504e-03 2.0168e-04 4.2024e-04 3.0354e-04 1.4519e-04 5.2270e-04 -1.0158e-03 6.8927e-04 2.1718e-04 1.1907e-04 9.5652e-04 8.6909e-04 -5.2818e-03 1.1458e-03 1.2787e-04 9.1497e-05 1.7540e-03 5.4711e-05 1.9008e-05 2.1404e-06 1.1484e-06 3.0147e-05 8.3675e-03 1.3078e-04 -1.0558e+00 1.2476e-01 9.8898e-03 6.3039e-03 1.9135e-01 12 8 8 10 0 0 99.84 24.15 0.31 0.00837 0.00904 16 4 1 5 0 3073.332 28.84 20.02 24.15 25.54 35.3 965.78 61 -6 98 54 224 301 -33 122 7 452 16 -12 -84 -214 191 -311 119 -274 -59 -252 -156 54 -56 -339 -164 257 73 -102 -56 29 12 -256 423 -215 300 82 8 226 -58 -30 44 -315 -150 -21 -30 -34 33 -87 292 -59 40 -45 -356 210 -174 307 56 -44 -375 114 -471 147 269 -36 107 -171 201 -10 3 -217 -228 608 -368 315 -111 -3 155 -50 351 103 -202 -322 283 355 50 901 -320 390 -90 189 -144 -93 -287 -119 -253 -392 164 112 -340 -19 -178 245 -497 119 -186 -68 -114 189 50 74 196 -21 281 -177 -243 147 -210 -78 -33 191 -310 -34 -91 -89 -5 101 414 -52 609 234 169 -87 -308 -35 134 83 -587 45 -216 79 86 -54 121 7 249 290 -23 -78 -137 9 -110 214 -238 340 -163 311 31 -134 -213 57 160 -431 -168 -43 -312 -355 -26 66 -340 -56 -206 230 -2 243 -37 -94 134 -3 -34 240 -101 270 -316 6 -106 179 -203 -13 140 600 -408 139 49 75 21 232 169 178 -107 10 -21 26 -207 94 28 -119 446 -218 -125 -227 -89 89 -100 -45 5 12 -205 465 191 101 128 -59 -136 -180 335 13 -1 -136 -99 197 -18 203 73 -56 128 -177 -46 -209 65 -172 104 -179 -124 -256 -51 81 -36 237 -136 176 -93 187 225 19 135 -54 -49 -538 -223 -290 54 293 154 205 -75 31 -3 47 28 124 170 -19 71 4 282 10 -8 -58 -149 129 -204 77 -174 -37 -171 -112 42 -45 -291 -144 222 64 -87 -49 26 11 -223 364 -183 255 70 6 185 -47 -24 36 -263 -123 -17 -25 -30 30 -85 288 -59 41 -46 -371 218 -175 298 51 -38 -327 101 -435 137 245 -33 98 -159 193 -10 2 -202 -213 577 -350 297 -104 -3 146 -48 313 91 -178 -286 262 343 49 906 -328 382 -87 184 -142 -95 -308 -126 -255 -352 132 85 -285 -17 -172 229 -437 98 -149 -57 -102 184 51 73 187 -20 258 -175 -250 153 -223 -83 -34 188 -299 -33 -94 -96 -6 116 468 -59 650 247 174 -89 -321 -36 137 82 -577 46 -236 88 96 -59 131 7 268 322 -27 -90 -155 10 -120 233 -252 327 -144 254 25 -113 -194 56 168 -481 -185 -47 -348 -393 -29 68 -339 -55 -211 241 -3 267 -42 -109 155 -3 -36 234 -98 268 -331 6 -115 193 -219 -14 153 651 -424 139 49 77 22 238 184 204 -132 12 -27 32 -253 113 33 -136 490 -237 -135 -262 -108 108 -121 -52 5 12 -202 470 209 117 153 -69 -164 -219 417 16 -1 -169 -124 246 -22 260 94 -70 163 -221 -54 -249 77 -204 122 -214 -151 -313 -58 88 -36 226 -129 166 -91 193 245 21 142 -53 -44 -448 -182 -234 45 246 142 209 -84