File name: Pandora171s1_Beijing-RADI_20230701_L2Fit_ffuh5c1d20210725p1-8.txt File generation date: 20230706T030907.0Z Data description: Level 2 spectral fitting results file Data file version: ffuh5c1p1-8 Local principal investigator: Li Kaitao Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 171 Spectrometer number: 1 Processing software version used: BlickP v1.8.49 Instrument operation file used: Pandora171_OF_v3d20200518.txt Instrument calibration file used: Pandora171s1_CF_v1d20210725.txt Level 1 file used: Pandora171s1_Beijing-RADI_20230701_L1_smca1c1d20210725p1-8.txt Full location name: Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing Short location name: Beijing-RADI Country of location: China Location latitude [deg]: 40.0048 Location longitude [deg]: 116.3786 Location altitude [m]: 59 Local noon date: 20230701 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 393 613 Nominal wavelengths inside fitting window [nm]: 328.6162 328.7553 328.8943 329.0333 329.1723 329.3113 329.4502 329.5892 329.7281 329.8671 330.0060 330.1449 330.2838 330.4227 330.5616 330.7004 330.8393 330.9781 331.1170 331.2558 331.3946 331.5334 331.6722 331.8110 331.9497 332.0885 332.2272 332.3659 332.5046 332.6433 332.7820 332.9207 333.0594 333.1980 333.3367 333.4753 333.6139 333.7525 333.8911 334.0297 334.1683 334.3068 334.4454 334.5839 334.7224 334.8609 334.9994 335.1379 335.2764 335.4149 335.5533 335.6917 335.8302 335.9686 336.1070 336.2454 336.3837 336.5221 336.6605 336.7988 336.9371 337.0755 337.2138 337.3520 337.4903 337.6286 337.7669 337.9051 338.0433 338.1815 338.3198 338.4579 338.5961 338.7343 338.8725 339.0106 339.1487 339.2869 339.4250 339.5631 339.7011 339.8392 339.9773 340.1153 340.2534 340.3914 340.5294 340.6674 340.8054 340.9433 341.0813 341.2193 341.3572 341.4951 341.6330 341.7709 341.9088 342.0467 342.1845 342.3224 342.4602 342.5981 342.7359 342.8737 343.0114 343.1492 343.2870 343.4247 343.5625 343.7002 343.8379 343.9756 344.1133 344.2510 344.3886 344.5263 344.6639 344.8015 344.9391 345.0767 345.2143 345.3519 345.4895 345.6270 345.7645 345.9021 346.0396 346.1771 346.3146 346.4520 346.5895 346.7269 346.8644 347.0018 347.1392 347.2766 347.4140 347.5513 347.6887 347.8261 347.9634 348.1007 348.2380 348.3753 348.5126 348.6499 348.7871 348.9244 349.0616 349.1988 349.3360 349.4732 349.6104 349.7475 349.8847 350.0218 350.1590 350.2961 350.4332 350.5703 350.7074 350.8444 350.9815 351.1185 351.2555 351.3926 351.5296 351.6665 351.8035 351.9405 352.0774 352.2144 352.3513 352.4882 352.6251 352.7620 352.8988 353.0357 353.1726 353.3094 353.4462 353.5830 353.7198 353.8566 353.9934 354.1301 354.2669 354.4036 354.5403 354.6770 354.8137 354.9504 355.0870 355.2237 355.3603 355.4970 355.6336 355.7702 355.9068 356.0433 356.1799 356.3164 356.4530 356.5895 356.7260 356.8625 356.9990 357.1354 357.2719 357.4083 357.5448 357.6812 357.8176 357.9540 358.0904 358.2267 358.3631 358.4994 358.6358 358.7721 358.9084 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Formaldehyde effective temperature [K] Column 28: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 45: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Oxygen dimer effective temperature [K] Column 50: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Ozone effective temperature [K] Column 61: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Fitted Ring spectrum, -9e99=no fitting done or fitting not successful Column 67: Independent uncertainty of fitted Ring spectrum, -9=fitting not successful Column 68: Structured uncertainty of fitted Ring spectrum, -9=fitting not successful Column 69: Common uncertainty of fitted Ring spectrum, -9=fitting not successful Column 70: rms-based uncertainty of fitted Ring spectrum, -9=fitting not successful Column 71: Effective Ring fitting wavelength [nm], -9=fitting not done or not successful Column 72: Diffuse correction applied before fitting at effective Ring fitting wavelength [%], 0=no diffuse correction applied, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 73: Lower limit used for wavelength scaling [nm] Column 74: Upper limit used for wavelength scaling [nm] Column 75: Order of smoothing polynomial Column 76: Smoothing polynomial coefficient, order 0 Column 77: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 78: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 79: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 80: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 81: Smoothing polynomial coefficient, order 1 Column 82: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 83: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 84: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 85: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 86: Smoothing polynomial coefficient, order 2 Column 87: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 88: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 89: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 90: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 91: Smoothing polynomial coefficient, order 3 Column 92: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 93: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 94: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 95: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 96: Smoothing polynomial coefficient, order 4 Column 97: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 98: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 99: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 100: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 101: Mean value of measured data inside fitting window [same units as measurements] Column 102: Offset polynomial coefficient, order 0 Column 103: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 104: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 105: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 106: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 107: Offset polynomial coefficient, order 1 Column 108: Independent uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 109: Structured uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 110: Common uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 111: rms-based uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 112: Wavelength change polynomial coefficient, order 0 Column 113: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 114: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 115: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 116: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 117: Wavelength change polynomial coefficient, order 1 Column 118: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 119: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 120: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 121: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 122: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 123: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 124: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 125: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 126: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 127: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 128: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 129: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 130: Atmospheric variability [%], 999=no atmospheric variability was determined Column 131: Wavelength effective temperature [°C], 999=no effective temperature given Column 132: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 133: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 134: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 135: Number of bright count cycles Column 136: Number of dark count cycles Column 137: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 138: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 139: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 140: Integration time [ms] Column 141: Spectrometer control temperature [°C], 999=no temperature signal Column 142: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 143: Temperature in head sensor [°C], 999=no temperature signal Column 144: Temperature at electronics board 1 [°C], 999=no temperature signal Column 145: Temperature at electronics board 2 [°C], 999=no temperature signal Column 146: Humidity in head sensor [%], -9=no humidity signal Column 147: Pressure in head sensor [hPa], -9=no pressure signal Columns 148-368: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 369-589: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------