File name: Pandora80s1_BeltsvilleMD_20230828_L2Fit_fsus1c8d20220601p1-8.txt File generation date: 20230830T120844.7Z Data description: Level 2 spectral fitting results file Data file version: fsus1c8p1-8 Local principal investigator: John Sullivan Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 80 Spectrometer number: 1 Processing software version used: BlickP v1.8.49 Instrument operation file used: Pandora80_OF_v4d20220517.txt Instrument calibration file used: Pandora80s1_CF_v8d20220601.txt Level 1 file used: Pandora80s1_BeltsvilleMD_20230828_L1_smca1c8d20220601p1-8.txt Full location name: Howard University-Beltsville Campus, Beltsville, MD Short location name: BeltsvilleMD Country of location: United States Location latitude [deg]: 39.0567 Location longitude [deg]: -76.8758 Location altitude [m]: 70 Local noon date: 20230828 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 203 347 Nominal wavelengths inside fitting window [nm]: 306.1167 306.2576 306.3986 306.5396 306.6805 306.8214 306.9623 307.1032 307.2441 307.3850 307.5259 307.6667 307.8076 307.9484 308.0893 308.2301 308.3709 308.5117 308.6524 308.7932 308.9340 309.0747 309.2155 309.3562 309.4969 309.6376 309.7783 309.9190 310.0596 310.2003 310.3409 310.4816 310.6222 310.7628 310.9034 311.0440 311.1846 311.3252 311.4657 311.6063 311.7468 311.8873 312.0278 312.1683 312.3088 312.4493 312.5898 312.7302 312.8707 313.0111 313.1515 313.2919 313.4323 313.5727 313.7131 313.8535 313.9938 314.1342 314.2745 314.4148 314.5551 314.6954 314.8357 314.9760 315.1162 315.2565 315.3967 315.5370 315.6772 315.8174 315.9576 316.0978 316.2380 316.3781 316.5183 316.6584 316.7985 316.9386 317.0788 317.2188 317.3589 317.4990 317.6391 317.7791 317.9191 318.0592 318.1992 318.3392 318.4792 318.6192 318.7591 318.8991 319.0390 319.1790 319.3189 319.4588 319.5987 319.7386 319.8785 320.0183 320.1582 320.2980 320.4378 320.5777 320.7175 320.8573 320.9971 321.1368 321.2766 321.4163 321.5561 321.6958 321.8355 321.9752 322.1149 322.2546 322.3943 322.5339 322.6736 322.8132 322.9528 323.0925 323.2321 323.3716 323.5112 323.6508 323.7903 323.9299 324.0694 324.2089 324.3485 324.4880 324.6274 324.7669 324.9064 325.0458 325.1853 325.3247 325.4641 325.6035 325.7429 325.8823 326.0217 326.1610 326.3004 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20230828T123554.8Z 8640.524940 163 1 17.20 2 67.05 96.22 149.27 285.83 0.00 1 0.00 1 0 33 4.306e-03 1.404e-03 4.934e-03 1.410e-03 7.734935e-07 5.161792e-07 2.538971e-08 3.774847e-07 1.967853e-06 230.67 -2.00 3.47 -2.00 322.03 0.00e+00 5.637926e-04 1.923976e-04 1.668160e-05 1.616638e-05 5.057570e-04 290.10 -2.00 20.00 -2.00 321.89 0.00e+00 -9.459000e-05 2.558726e-04 6.593398e-06 2.504842e-05 9.127635e-04 290.10 -2.00 20.00 -2.00 321.81 0.00e+00 3.980986e-04 4.083177e-04 5.613561e-05 1.469705e-05 9.547792e-04 290.10 -2.00 20.00 -2.00 321.88 0.00e+00 3.149506e-01 2.185576e-03 1.622340e-04 1.702815e-03 5.283476e-03 236.29 1.69 0.00 0.53 9.12 318.72 0.00e+00 -7.829231e-05 1.409941e-04 3.770480e-05 1.209759e-05 1.424792e-04 290.10 -2.00 20.00 -2.00 317.46 0.00e+00 2.544 0.000 303.00 329.40 4 3.0376e+00 5.8019e-03 2.4570e-02 1.9457e-03 1.6613e-02 -1.7957e-02 8.5690e-03 2.7230e-03 3.8905e-04 1.7777e-02 7.1593e-03 4.3669e-03 4.0144e-04 1.4035e-04 9.6338e-03 -4.5825e-03 2.2477e-03 1.1126e-04 6.0328e-05 3.9375e-03 6.5090e-04 1.4372e-03 5.1548e-05 6.6502e-05 2.8781e-03 1.6841e-03 -5.3991e-03 7.3107e-04 4.3603e-05 1.4536e-05 6.8327e-04 -1.1369e-04 4.1249e-05 2.0633e-06 7.0565e-07 1.2736e-04 -1.4272e-02 6.5921e-05 -1.5672e-01 1.0151e-01 1.2327e-03 3.3099e-04 2.8067e-01 12 9 1 12 1 1 99.55 25.01 0.64 -0.01427 -0.01514 39 18 1 5 0 425.770 27.35 20.00 25.01 32.64 4.4 1020.36 -28 -1850 1080 1471 315 -463 -977 65 -1308 1597 -1302 149 86 181 -364 518 -1125 -740 781 -447 1007 118 1101 108 -117 955 -100 -627 -618 -127 -609 172 126 71 64 -135 705 324 -327 -187 52 189 -21 198 18 112 -116 -55 -15 43 -204 -195 318 -316 -200 292 88 -27 143 -67 -25 66 -186 8 109 24 -114 0 248 -175 161 25 117 32 63 -103 -227 -79 -219 99 31 -121 -331 316 53 147 -122 231 23 -11 102 -182 136 -167 234 -306 -9 50 21 18 -49 73 -9 49 -46 8 22 -38 58 178 -1 -171 269 70 -39 124 105 -97 -191 -46 124 -44 -99 -45 12 -168 112 -130 54 152 -9 37 -104 -194 86 68 -77 75 -62 -12 -19 6 16 79 -18 -2 -151 90 120 28 -47 -115 9 -194 239 -211 25 15 32 -63 94 -223 -154 166 -95 197 22 209 23 -27 239 -26 -150 -153 -35 -181 61 52 31 27 -58 301 139 -142 -87 24 86 -10 92 9 59 -65 -31 -9 25 -120 -113 184 -193 -123 194 62 -19 90 -44 -16 45 -145 7 86 20 -90 0 161 -115 105 17 90 25 55 -96 -221 -77 -227 106 34 -131 -338 314 49 126 -107 223 23 -13 119 -219 155 -191 243 -312 -10 56 24 22 -63 93 -13 71 -66 10 29 -47 69 218 -2 -225 369 95 -52 160 137 -121 -228 -53 150 -58 -133 -63 18 -248 164 -204 88 237 -15 59 -167 -301 129 101 -122 123 -105 -21 -35 11 32 159 -36 SS 20230828T125319.3Z 8640.537029 168 1 50.95 2 63.71 99.17 152.28 290.28 0.00 1 0.00 1 0 49 1.082e-02 3.386e-03 1.099e-02 2.904e-03 -3.881748e-06 1.063902e-06 9.791707e-08 3.775483e-07 4.936587e-06 230.67 -2.00 3.47 -2.00 322.29 0.00e+00 1.705353e-03 4.057419e-04 6.991371e-05 1.619825e-05 1.277205e-03 290.10 -2.00 20.00 -2.00 322.33 0.00e+00 1.163874e-04 5.330771e-04 1.430726e-05 2.499377e-05 2.277417e-03 290.10 -2.00 20.00 -2.00 321.99 0.00e+00 -1.637179e-04 9.075723e-04 7.119878e-05 1.467462e-05 2.399174e-03 290.10 -2.00 20.00 -2.00 322.14 0.00e+00 2.760402e-01 4.596299e-03 2.673572e-04 1.702888e-03 1.323820e-02 227.13 3.93 0.00 0.61 22.87 319.09 0.00e+00 -4.460955e-04 3.152224e-04 2.055180e-05 1.213562e-05 3.556944e-04 290.10 -2.00 20.00 -2.00 317.80 0.00e+00 2.244 0.000 303.00 329.40 4 5.3400e+00 1.0754e-02 2.1672e-02 1.9469e-03 4.1785e-02 -2.8333e-02 1.7365e-02 2.4598e-03 3.9241e-04 4.4660e-02 2.9764e-02 8.9693e-03 8.9862e-04 1.4614e-04 2.4311e-02 -1.5915e-02 4.5068e-03 6.2309e-04 6.4621e-05 9.8885e-03 7.2642e-04 2.9265e-03 8.1673e-05 6.7901e-05 6.9483e-03 2.4051e-04 -9.4417e-03 1.9709e-03 1.9401e-04 2.1603e-05 2.4270e-03 -2.1021e-04 8.7719e-05 4.9564e-06 7.1334e-07 3.1968e-04 -1.3872e-02 6.6729e-05 2.8793e-01 2.3097e-01 5.6813e-03 2.5344e-04 7.6609e-01 12 9 8 11 8 0 98.39 25.13 0.63 -0.01387 -0.01548 17 3 1 5 0 2996.550 27.35 20.00 25.13 33.30 4.4 1025.31 -2557 -818 6346 3680 78 1203 -345 -1158 325 2154 4926 -673 -693 903 -368 1329 651 -43 -1425 535 -2730 -338 1452 -862 -3059 468 -233 -634 2938 362 954 -663 -21 -1111 -767 84 -315 358 80 70 -1504 -215 -920 -592 108 1124 -157 615 1066 268 -926 -685 139 669 273 462 466 -237 -1106 -279 -1346 -475 -80 262 212 839 688 131 822 10 -520 -497 743 294 621 70 -277 265 -135 -8 334 200 -458 243 -492 -186 -113 -281 103 -215 -136 -96 513 297 -666 -339 -460 31 -84 285 -38 -311 113 167 39 407 -32 -158 244 -160 -359 3 -532 344 45 77 -187 -19 -488 324 64 107 23 104 189 -317 35 -36 37 99 510 -222 -102 -298 343 -55 -102 -217 72 165 269 83 -66 -140 -147 -185 -64 487 285 7 115 -38 -145 43 291 679 -101 -108 140 -57 213 112 -8 -273 99 -486 -55 238 -157 -610 99 -50 -127 588 83 255 -216 -8 -446 -318 35 -133 150 33 29 -618 -86 -379 -261 50 549 -82 326 576 149 -512 -371 75 376 167 306 297 -162 -694 -167 -809 -314 -55 189 158 605 474 92 512 6 -301 -317 535 215 499 59 -246 253 -137 -8 357 212 -459 222 -415 -160 -90 -245 99 -232 -161 -117 591 319 -666 -329 -484 35 -99 352 -49 -426 151 232 53 575 -42 -191 285 -192 -459 4 -770 491 63 104 -241 -23 -575 363 76 137 32 149 276 -436 51 -56 59 161 844 -367 -162 -458 507 -82 -160 -370 132 325 526 169 -138 -294 -303 SS 20230828T133415.0Z 8640.565451 193 1 51.00 2 55.97 106.67 158.90 304.18 0.00 1 0.00 1 0 33 1.141e-02 4.258e-03 9.158e-03 3.491e-03 -3.380147e-06 1.302913e-06 7.179515e-08 3.774265e-07 5.249827e-06 230.67 -2.00 3.47 -2.00 321.93 0.00e+00 1.158741e-03 4.750801e-04 3.303065e-05 1.611545e-05 1.374819e-03 290.10 -2.00 20.00 -2.00 321.79 0.00e+00 1.207464e-05 6.416841e-04 1.976824e-05 2.495891e-05 2.395649e-03 290.10 -2.00 20.00 -2.00 321.71 0.00e+00 1.293452e-03 9.641857e-04 8.684280e-05 1.481533e-05 2.531737e-03 290.10 -2.00 20.00 -2.00 321.77 0.00e+00 2.201315e-01 5.049306e-03 1.964078e-04 1.702863e-03 1.385439e-02 227.68 5.56 0.00 0.77 24.04 318.23 0.00e+00 -3.058998e-04 3.040781e-04 5.140587e-05 1.204853e-05 3.704518e-04 290.10 -2.00 20.00 -2.00 316.94 0.00e+00 1.781 0.000 303.00 329.40 4 6.0313e+00 1.2908e-02 1.7230e-02 1.9445e-03 4.3919e-02 -2.1080e-02 1.8877e-02 2.1171e-03 3.7803e-04 4.6979e-02 2.4113e-02 9.9625e-03 7.6659e-04 1.3309e-04 2.5890e-02 -1.2200e-02 4.2630e-03 4.2253e-04 4.2563e-05 1.0061e-02 2.6890e-04 3.0050e-03 5.3655e-05 5.5094e-05 6.7670e-03 1.9712e-04 -6.7002e-03 2.7723e-03 1.6959e-04 2.2489e-05 4.0758e-03 -1.7905e-05 1.0437e-04 3.6747e-06 6.8840e-07 3.3679e-04 -1.3706e-02 5.7745e-05 5.4047e-01 3.1874e-01 4.5066e-03 4.2490e-04 9.2707e-01 12 9 8 11 8 0 98.44 25.30 0.41 -0.01371 -0.01384 13 2 1 5 0 3923.040 27.56 20.00 25.30 33.72 4.4 1028.66 -8099 518 -163 -450 2283 -941 2839 -2150 2993 -1713 304 -939 3702 158 656 971 -1539 -200 -41 818 2444 435 791 2158 -1379 -667 -565 -2414 -4 876 853 -505 168 -1625 -333 1063 -1003 1818 24 1099 -1615 -454 -310 -414 -75 -378 1035 -317 -356 925 -737 321 85 740 -301 565 -757 -577 -150 -55 -1183 -508 1353 -40 369 -898 587 -1118 463 304 -262 1023 -312 735 243 12 76 611 224 -396 75 682 117 136 -225 -728 -139 -366 -146 187 -624 0 -6 407 146 59 -163 217 -488 144 -180 51 -39 -98 133 483 -114 -385 457 -93 -449 -218 -255 -154 432 233 -40 -113 -165 -195 -284 305 -169 510 551 -221 292 -136 -182 -74 -268 645 -141 -258 -14 -65 265 -213 178 -164 321 -239 3 55 -73 -988 64 -21 -57 293 -140 457 -407 579 -353 64 -204 797 36 145 222 -383 -51 -11 210 570 97 176 505 -354 -185 -157 -631 -1 256 291 -209 79 -822 -172 553 -530 931 12 547 -803 -218 -150 -215 -41 -218 617 -195 -223 581 -464 197 52 475 -211 422 -601 -438 -102 -35 -767 -361 1069 -34 322 -777 479 -852 311 189 -160 674 -236 610 222 11 70 596 232 -430 82 736 120 140 -212 -634 -121 -348 -153 197 -724 0 -7 425 156 61 -168 241 -568 175 -227 67 -54 -142 190 644 -141 -438 498 -105 -536 -281 -346 -209 570 299 -49 -131 -200 -226 -347 362 -213 665 729 -301 416 -206 -286 -118 -442 1042 -222 -394 -21 -97 412 -360 322 -292 610 -473 5 111 -143 SS 20230828T152437.2Z 8640.642097 261 1 52.42 2 37.50 134.68 165.06 24.47 0.00 1 0.00 1 0 33 3.689e-03 2.345e-03 3.091e-03 1.864e-03 -1.547974e-06 7.069773e-07 5.616133e-08 3.772818e-07 1.701467e-06 230.66 -2.00 3.47 -2.00 321.09 0.00e+00 1.131696e-03 2.411254e-04 4.577460e-05 1.599469e-05 4.485890e-04 290.10 -2.00 20.00 -2.00 320.80 0.00e+00 -5.496770e-05 3.460047e-04 7.405964e-06 2.494839e-05 7.797857e-04 290.10 -2.00 20.00 -2.00 321.12 0.00e+00 3.473359e-04 4.517128e-04 3.211801e-05 1.493310e-05 8.193033e-04 290.10 -2.00 20.00 -2.00 320.98 0.00e+00 1.599703e-01 2.408666e-03 1.194711e-04 1.702832e-03 4.439808e-03 228.10 3.74 0.00 1.07 7.79 316.70 0.00e+00 1.364569e-04 1.135260e-04 1.723697e-05 1.195521e-05 1.186137e-04 290.10 -2.00 20.00 -2.00 315.50 0.00e+00 1.259 0.000 303.00 329.40 4 5.8170e+00 6.8192e-03 1.2166e-02 1.9416e-03 1.4251e-02 -2.1143e-03 8.8507e-03 1.4196e-03 3.5286e-04 1.5144e-02 1.4194e-02 4.7554e-03 4.8014e-04 1.1176e-04 8.3963e-03 -4.7313e-03 1.7147e-03 1.4070e-04 2.5482e-05 3.0446e-03 -2.0456e-03 1.3748e-03 1.5049e-04 4.1937e-05 2.1433e-03 4.4592e-04 -4.4077e-03 1.5303e-03 1.2323e-04 2.3609e-05 1.8784e-03 7.6163e-05 5.4130e-05 2.4994e-06 6.6268e-07 1.0877e-04 -1.3715e-02 1.1340e-04 7.6005e-01 1.9407e-01 8.5570e-03 5.3683e-04 3.3680e-01 12 8 8 10 0 0 99.85 25.49 0.77 -0.01371 -0.01313 17 3 1 5 0 3083.020 27.67 20.00 25.49 35.38 4.4 1040.45 -474 1073 273 86 290 703 958 -58 -169 715 -244 -882 806 -620 466 -897 22 -114 -410 -79 -739 1515 -433 -156 -389 -142 -495 586 511 -189 323 -220 114 97 -341 342 -102 -307 -520 460 -243 -301 -375 24 580 -708 -50 527 192 -91 18 -453 405 16 -123 238 143 -386 444 242 -487 -15 -2 61 281 -144 662 -284 128 -56 -187 542 193 -7 -321 218 -161 168 -116 28 -14 255 199 -141 -273 -259 219 -170 -413 215 508 181 -151 154 -35 -268 -161 -395 -183 -88 -40 16 -14 150 -43 139 58 -187 -50 -228 -319 -313 -71 295 105 197 -170 -2 -54 76 111 123 -287 -40 107 -227 366 182 84 -136 66 -27 -22 169 -14 105 -113 41 19 114 127 -57 43 -117 -176 -107 261 69 21 72 192 289 -20 -60 254 -89 -333 307 -241 175 -353 9 -48 -179 -33 -289 537 -155 -58 -152 -59 -207 223 199 -82 163 -121 71 63 -230 234 -69 -208 -349 295 -151 -181 -225 15 383 -493 -36 382 142 -68 13 -330 295 12 -101 208 130 -334 342 176 -348 -12 -2 57 270 -137 597 -237 95 -42 -135 422 155 -6 -309 217 -169 174 -128 32 -16 292 214 -151 -267 -231 194 -163 -435 247 583 212 -169 176 -37 -280 -183 -446 -214 -107 -51 22 -20 212 -60 180 69 -221 -57 -266 -362 -386 -93 385 134 245 -200 -3 -62 84 127 150 -339 -48 131 -284 479 253 121 -200 99 -41 -32 239 -20 145 -163 63 29 187 223 -103 78 -214 -314 SS 20230828T225813.1Z 8640.957096 540 1 52.24 2 81.99 275.81 88.03 124.30 0.00 1 0.00 1 0 65 1.541e-01 1.047e-02 2.839e-01 9.987e-03 9.371442e-07 4.326302e-06 2.408997e-06 3.782705e-07 6.586132e-05 230.64 -2.00 3.47 -2.00 324.42 0.00e+00 8.222284e-03 2.001511e-03 9.425498e-04 1.597800e-05 1.780714e-02 290.07 -2.00 20.00 -2.00 325.21 0.00e+00 5.308824e-03 2.915949e-03 5.770860e-04 2.587839e-05 3.237038e-02 290.07 -2.00 20.00 -2.00 323.83 0.00e+00 5.632212e-04 6.372178e-03 6.427385e-04 1.633700e-05 3.414829e-02 290.07 -2.00 20.00 -2.00 324.25 0.00e+00 7.523818e-01 2.812168e-02 3.635039e-03 1.698920e-03 1.912300e-01 228.48 8.61 0.00 0.23 322.06 323.21 0.00e+00 -1.310227e-02 4.787714e-03 4.096796e-03 1.360349e-05 4.984718e-03 290.07 -2.00 20.00 -2.00 322.37 0.00e+00 6.702 0.005 303.00 329.40 4 2.1888e+00 5.5686e-02 6.6518e-02 1.9498e-03 5.9329e-01 4.1229e-01 1.1828e-01 4.5553e-02 4.2671e-04 6.3310e-01 -8.5990e-01 6.7002e-02 7.4751e-03 1.6584e-04 3.4425e-01 7.5984e-01 3.2633e-02 2.5419e-02 1.1049e-04 1.1629e-01 -2.5006e-01 1.9710e-02 8.9454e-03 9.1395e-05 8.9786e-02 5.1625e-05 5.3899e-02 1.3513e-02 2.0566e-04 7.6859e-07 7.5800e-04 2.6608e-04 4.4378e-04 6.4534e-05 8.7883e-07 4.5950e-03 -1.2998e-02 1.0408e-04 5.8388e-01 3.8521e-01 5.8787e-02 3.8522e-04 4.9642e+00 12 8 8 10 0 0 99.41 25.33 0.64 -0.01300 -0.01097 31 5 1 5 0 1684.880 27.56 20.00 25.33 33.13 4.4 1022.42 11389 46156 1658 -6876 5268 -5785 44935 -6360 39196 58188 28485 13895 -6147 9319 -7091 27001 15093 24146 32425 -16827 893 -61755 -23412 -47002 6197 6489 -16720 -33854 -19251 -9116 24411 -217 26649 47296 18881 26369 6046 10465 17798 -3583 2584 -15748 4562 -5554 8018 7222 21552 24843 8939 16034 -3781 23846 -7301 17489 8970 3713 2103 -4063 4043 -5850 4969 -1413 9221 -590 2511 9388 -4062 -7467 -17020 -6563 -10081 -5578 -5101 2797 3082 45 -1142 2115 -350 -782 2782 -579 -2523 -3295 -4610 -1217 -5039 1654 688 583 2763 1372 219 -2482 -1034 -1594 1878 -3064 2284 -1236 406 -582 892 171 453 1372 553 -915 -1440 638 352 -1157 813 -718 1684 1229 -411 34 385 1051 -821 344 -408 292 -513 -710 -375 -147 134 -78 1085 -293 -374 -388 299 283 -275 420 65 -47 -691 -5 576 -192 47 166 436 36 -160 95 -164 425 -241 539 550 490 311 -190 168 -165 255 285 394 390 -564 13 -2814 -523 -2101 107 139 -575 -1310 -563 -266 483 -10 1031 1382 941 1111 322 477 741 -207 137 -1162 272 -452 607 615 1671 1973 938 1562 -451 1759 -773 1340 874 449 292 -611 524 -885 705 -255 1726 -134 560 1829 -845 -1419 -3203 -1061 -1830 -1160 -1293 764 970 16 -426 818 -146 -340 1171 -247 -1031 -1256 -1713 -440 -2106 758 375 370 1965 1038 161 -1721 -628 -918 1115 -2071 1523 -916 321 -520 894 190 522 1550 606 -965 -1506 678 396 -1398 975 -839 1839 1308 -426 34 372 1003 -900 432 -579 452 -849 -1249 -708 -296 278 -166 2300 -611 -734 -717 522 499 -527 893 139 -111 -1827 -14 1730 -606 148 SS 20230828T231018.0Z 8640.965486 543 1 53.53 2 84.32 277.68 86.17 126.19 0.00 1 0.00 1 0 225 1.579e-01 4.343e-02 2.573e-01 4.283e-02 1.505442e-05 1.879038e-05 2.327428e-06 3.782300e-07 6.751761e-05 230.64 -2.00 3.47 -2.00 324.50 0.00e+00 2.361233e-02 8.550012e-03 2.146011e-03 1.595058e-05 1.836994e-02 290.07 -2.00 20.00 -2.00 325.24 0.00e+00 1.739062e-02 1.217601e-02 1.150049e-03 2.523216e-05 3.317217e-02 290.07 -2.00 20.00 -2.00 323.92 0.00e+00 5.500483e-02 2.406974e-02 5.260697e-03 1.555577e-05 3.497595e-02 290.07 -2.00 20.00 -2.00 324.34 0.00e+00 5.244048e-01 8.671733e-02 1.557140e-02 1.700513e-03 1.974985e-01 135.24 33.79 0.00 0.25 332.62 322.18 0.00e+00 -1.544796e-02 7.370820e-03 3.076737e-03 1.213226e-05 5.165938e-03 290.07 -2.00 20.00 -2.00 320.86 0.00e+00 8.898 0.012 303.00 329.40 4 6.2746e-01 2.7847e-01 9.1916e-02 1.9468e-03 6.1254e-01 1.2707e+00 2.1642e-01 7.4489e-02 4.3601e-04 6.5362e-01 -1.1503e+00 1.4973e-01 3.3337e-02 1.5235e-04 3.5294e-01 2.4330e-01 7.2886e-02 2.3467e-02 5.2426e-05 1.1957e-01 2.3145e-02 4.8198e-02 4.7923e-03 4.3689e-05 9.3477e-02 8.7427e-06 9.3115e-01 1.8392e-01 1.7658e-08 4.3144e-11 1.6887e-07 -4.0677e-04 1.8981e-03 1.8009e-04 7.6032e-07 4.7240e-03 -1.1491e-02 8.7824e-06 3.0250e+00 1.3265e+00 5.3051e-02 3.1422e-04 3.9723e+00 12 9 8 11 8 0 93.55 25.30 1.68 -0.01149 -0.01460 16 2 1 5 0 3345.430 27.56 20.00 25.30 33.27 4.5 1025.84 -5982 -18159 -386 -2376 -10807 36250 31231 33851 58856 32324 14038 18526 26610 8027 20957 24662 17172 22353 37542 -5009 30866 -22280 -25221 -28697 -11001 -5322 -6554 -8272 -23086 -10605 4589 17420 36145 43962 28834 20635 22877 27998 6150 -12670 -16055 -8932 -17685 15759 -13907 12301 2940 11230 7861 2459 4676 -4200 -5137 -2151 8223 8848 8457 10220 -12693 12018 -22776 -857 16725 7335 14456 -3470 2352 -8806 -23091 -27527 -24340 -17385 -6166 4594 4780 13369 18085 4634 9107 3147 8793 567 -6228 -18226 -20170 -12121 -10482 -9524 8281 11679 22845 15455 8117 7045 -7201 2243 -6006 -3465 6090 -593 3890 -2282 5429 6646 4619 6301 -2729 -1231 -6937 -8017 -6076 -5990 -2843 3596 6586 2488 1913 -7281 -5828 -2316 -1382 -3969 -1514 -1954 4539 -1416 -1955 -2203 2224 249 3477 1219 586 679 -2608 477 1337 -2985 695 1764 2810 3389 -2396 117 -2039 -566 -3621 -54 -321 -2009 1470 2428 3432 2387 3714 2562 2567 2355 1125 1468 2000 2532 3214 2907 -1145 1252 -3532 -4091 -5396 -1460 -785 -991 -976 -4426 -1760 694 2890 4797 5025 4996 3804 2952 2168 952 -2896 -3788 -1712 -4369 1743 -3999 2086 716 2360 1855 635 965 -867 -928 -357 1182 1566 1715 1809 -3369 1551 -7138 -202 3268 1920 3401 -1084 553 -2143 -6181 -7368 -6515 -5358 -2050 1546 1880 4500 5501 1954 3620 1353 3210 225 -2450 -7687 -8180 -4326 -4379 -4983 4030 6726 13156 10342 5498 4200 -4556 1101 -3532 -2094 3310 -397 2697 -1943 4822 6496 4815 6235 -2856 -1169 -6977 -8519 -6604 -6826 -3193 3617 6117 2321 1668 -6998 -5413 -2067 -1395 -4893 -2069 -2972 6756 -2383 -3569 -4342 4357 510 6980 2417 1092 1203 -4590 802 2365 -6199 1557 4357 7693 10007 -8007 395 -7046