File name: Pandora21s1_Bremen_20230825_L2Fit_fsus1c6d20211128p1-8.txt File generation date: 20240905T000433.3Z Data description: Level 2 spectral fitting results file Data file version: fsus1c6p1-8 Local principal investigator: Tom Hanisco Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 21 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora21_OF_v4d20190904.txt Instrument calibration file used: Pandora21s1_CF_v6d20211128.txt Level 1 file used: Pandora21s1_Bremen_20230825_L1_smca1c6d20211128p1-8.txt Full location name: Bremen University Short location name: Bremen Country of location: Germany Location latitude [deg]: 53.0813 Location longitude [deg]: 8.8126 Location altitude [m]: 50 Local noon date: 20230825 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 293 438 Nominal wavelengths inside fitting window [nm]: 306.0309 306.1714 306.3118 306.4522 306.5926 306.7329 306.8733 307.0137 307.1540 307.2943 307.4346 307.5749 307.7152 307.8555 307.9958 308.1361 308.2763 308.4165 308.5568 308.6970 308.8372 308.9774 309.1176 309.2577 309.3979 309.5380 309.6781 309.8183 309.9584 310.0985 310.2386 310.3786 310.5187 310.6587 310.7988 310.9388 311.0788 311.2188 311.3588 311.4988 311.6387 311.7787 311.9186 312.0586 312.1985 312.3384 312.4783 312.6182 312.7581 312.8979 313.0378 313.1776 313.3174 313.4572 313.5970 313.7368 313.8766 314.0164 314.1561 314.2959 314.4356 314.5753 314.7150 314.8547 314.9944 315.1341 315.2737 315.4134 315.5530 315.6927 315.8323 315.9719 316.1115 316.2510 316.3906 316.5302 316.6697 316.8092 316.9487 317.0883 317.2277 317.3672 317.5067 317.6462 317.7856 317.9250 318.0645 318.2039 318.3433 318.4827 318.6220 318.7614 318.9008 319.0401 319.1794 319.3187 319.4581 319.5973 319.7366 319.8759 320.0152 320.1544 320.2936 320.4329 320.5721 320.7113 320.8505 320.9896 321.1288 321.2679 321.4071 321.5462 321.6853 321.8244 321.9635 322.1026 322.2417 322.3807 322.5198 322.6588 322.7978 322.9368 323.0758 323.2148 323.3538 323.4927 323.6317 323.7706 323.9095 324.0484 324.1873 324.3262 324.4651 324.6040 324.7428 324.8817 325.0205 325.1593 325.2981 325.4369 325.5757 325.7145 325.8532 325.9920 326.1307 326.2694 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20230825T081058.3Z 8637.340953 180 1 9.62 2 57.53 118.51 143.89 55.97 0.00 1 0.00 1 0 65 4.947e-03 2.665e-03 4.570e-03 2.373e-03 -3.215060e-06 9.386805e-07 5.704500e-08 3.956272e-07 2.396854e-06 231.36 -2.00 3.88 -2.00 321.18 0.00e+00 1.111528e-03 3.198476e-04 1.811385e-05 1.952793e-05 6.158664e-04 281.79 -2.00 20.00 -2.00 320.78 0.00e+00 1.613985e-06 4.432747e-04 1.596654e-05 2.610307e-05 1.058337e-03 281.79 -2.00 20.00 -2.00 321.18 0.00e+00 1.166872e-03 5.997092e-04 6.900555e-05 1.399847e-05 1.118108e-03 281.79 -2.00 20.00 -2.00 321.05 0.00e+00 2.210191e-01 3.346237e-03 1.125144e-04 2.587399e-03 6.508390e-03 227.82 3.63 0.00 0.12 11.01 317.10 0.00e+00 1.067455e-04 1.489253e-04 2.774833e-06 2.387325e-05 1.481545e-04 281.79 -2.00 20.00 -2.00 316.44 0.00e+00 1.856 0.000 303.00 329.40 4 4.3051e+00 9.1637e-03 1.7899e-02 1.0000e+00 2.0163e-02 9.8832e-03 1.2057e-02 1.9695e-03 2.4675e-04 2.1877e-02 1.3976e-02 6.6142e-03 3.1134e-04 5.7478e-05 1.2063e-02 -6.1954e-03 2.7395e-03 8.9318e-05 2.5530e-05 4.6278e-03 -9.2645e-04 1.8725e-03 4.4492e-05 4.6268e-05 2.9619e-03 9.9760e-04 -3.7308e-03 1.6460e-03 8.8156e-05 1.1362e-05 1.6729e-03 -4.5812e-04 7.2742e-05 2.7229e-06 6.7377e-07 1.5981e-04 -1.1178e-02 0.0000e+00 4.8938e-01 2.3445e-01 2.6139e-03 4.4627e-04 4.1470e-01 12 9 9 12 1 1 99.91 23.06 0.20 -0.01118 -0.01467 10 11 1 5 0 873.468 26.00 20.00 23.06 29.28 34.6 1013.51 1490 213 418 135 -473 470 -830 829 -1196 1043 -1159 1878 587 -1257 -109 -1404 -246 -1586 167 304 1060 -877 1141 587 100 -590 363 1004 -733 -262 -775 290 544 -587 103 190 474 95 451 -300 -222 -404 38 168 569 -3 -137 418 -408 78 -109 42 -316 286 41 216 -48 -363 722 -154 -269 -519 -18 -71 -159 -165 404 -362 -321 101 -268 -96 -401 191 93 23 -169 306 382 71 116 -521 231 131 457 -230 23 -111 -69 282 -414 527 -365 252 -269 204 173 32 279 -203 70 -59 -48 -381 77 92 -49 -105 2 184 -123 -122 -256 70 -129 210 247 -33 -84 -509 466 -169 114 -136 223 -118 131 223 181 -140 -176 98 -70 126 -108 40 -269 207 -18 53 -102 -54 134 -64 -22 34 243 38 80 26 -93 98 -194 212 -337 301 -350 568 184 -409 -35 -462 -83 -566 61 111 373 -297 367 193 35 -218 138 373 -270 -100 -330 140 295 -348 63 120 302 61 287 -190 -138 -247 23 103 363 -2 -95 296 -295 57 -80 31 -230 210 31 173 -40 -310 592 -121 -203 -399 -15 -62 -145 -153 369 -320 -268 78 -198 -71 -314 162 85 22 -168 314 410 79 132 -603 263 144 474 -226 22 -105 -69 298 -468 622 -438 295 -302 220 185 36 325 -244 86 -74 -62 -516 105 125 -65 -132 2 215 -146 -150 -329 93 -172 276 318 -41 -101 -599 536 -199 139 -172 288 -154 175 306 256 -203 -260 147 -103 185 -155 57 -381 299 -27 83 -168 -93 234 -113 -39 61 SS 20230825T081601.4Z 8637.344461 183 1 14.02 2 56.87 119.76 143.30 57.48 0.00 1 0.00 1 0 49 7.169e-03 3.444e-03 7.464e-03 3.543e-03 -3.162839e-06 1.394087e-06 6.336831e-08 3.956543e-07 3.476243e-06 231.36 -2.00 3.88 -2.00 321.35 0.00e+00 1.557528e-03 4.821894e-04 3.947293e-05 1.957729e-05 8.921666e-04 281.79 -2.00 20.00 -2.00 321.02 0.00e+00 7.158648e-04 6.637752e-04 1.372583e-05 2.609918e-05 1.534198e-03 281.79 -2.00 20.00 -2.00 321.31 0.00e+00 9.622450e-04 9.162253e-04 4.293753e-05 1.400910e-05 1.619822e-03 281.79 -2.00 20.00 -2.00 321.22 0.00e+00 2.263730e-01 5.133857e-03 9.958646e-05 2.587603e-03 9.412766e-03 230.56 5.45 0.00 0.13 15.96 317.41 0.00e+00 4.653375e-05 2.374190e-04 3.425956e-06 2.387457e-05 2.149249e-04 281.79 -2.00 20.00 -2.00 316.74 0.00e+00 1.824 0.000 303.00 329.40 4 5.2549e+00 1.4157e-02 1.7578e-02 1.0000e+00 2.9217e-02 3.8256e-02 1.8829e-02 1.8698e-03 2.4524e-04 3.1648e-02 4.2253e-03 1.0232e-02 4.6430e-04 5.7839e-05 1.7436e-02 -1.9908e-03 4.1922e-03 1.6254e-04 2.6783e-05 6.6559e-03 -2.1194e-03 2.8532e-03 7.6787e-05 4.8804e-05 4.2879e-03 3.8992e-04 -2.7740e-03 2.6520e-03 1.3237e-04 1.2913e-05 2.4561e-03 -5.0375e-04 1.1069e-04 3.4551e-06 6.7115e-07 2.3164e-04 -1.1136e-02 0.0000e+00 1.3536e+00 3.5806e-01 6.4952e-03 4.6515e-04 6.0279e-01 12 9 9 12 1 1 99.95 23.06 0.28 -0.01114 -0.01498 6 5 1 5 0 2000.978 26.00 20.00 23.06 29.56 34.7 1014.93 1143 1872 2205 585 -2419 2178 1904 -1128 652 645 -2918 -686 776 -458 -2756 164 1298 -502 10 900 -835 376 603 -897 -1251 -331 98 -401 1366 681 500 641 -279 -445 -173 -164 659 115 465 -574 -56 693 1036 -530 401 -843 153 812 88 -166 -643 71 -927 -426 457 89 848 12 -370 -445 -159 -787 -4 -99 260 88 329 157 -153 615 -313 -207 60 -183 -168 -364 -109 -166 587 258 198 -121 -268 -33 278 -325 12 -339 -118 185 48 289 540 206 -149 -95 137 -443 -180 -650 221 235 73 157 -31 52 110 -581 -98 420 -121 32 24 -404 108 358 -342 332 -278 -240 443 -378 44 -99 216 399 -282 -70 -117 -24 48 -96 393 -139 -25 306 -144 195 -414 121 -182 309 190 -330 134 -112 165 294 367 100 -429 398 389 -263 163 169 -811 -192 221 -135 -829 48 395 -162 3 300 -272 115 177 -271 -399 -111 34 -138 452 237 195 287 -143 -250 -102 -99 400 70 282 -347 -33 398 587 -310 244 -541 102 551 61 -117 -457 50 -652 -302 336 69 689 10 -297 -338 -116 -585 -3 -85 233 80 295 136 -124 459 -222 -147 45 -151 -150 -344 -107 -170 624 287 226 -140 -306 -36 286 -314 11 -315 -115 194 54 342 647 241 -167 -102 146 -495 -209 -787 274 299 96 214 -43 72 146 -735 -118 490 -143 40 31 -539 145 475 -445 416 -338 -281 507 -444 53 -125 281 526 -379 -97 -168 -36 72 -145 594 -208 -36 438 -207 286 -639 194 -307 542 341 -605 246 -205 SS 20230825T141333.6Z 8637.592750 406 1 49.40 2 53.88 233.96 95.93 129.48 0.00 1 0.00 1 0 33 9.362e-03 3.358e-03 6.864e-03 2.904e-03 -2.304231e-06 1.134278e-06 5.987179e-08 3.956773e-07 4.508053e-06 231.33 -2.00 3.88 -2.00 321.68 0.00e+00 1.396055e-03 4.021504e-04 3.232026e-05 1.964996e-05 1.165182e-03 281.76 -2.00 20.00 -2.00 321.49 0.00e+00 -1.086238e-04 5.489802e-04 1.619356e-05 2.607142e-05 2.001935e-03 281.76 -2.00 20.00 -2.00 321.53 0.00e+00 -8.242304e-04 7.783253e-04 2.420499e-05 1.403140e-05 2.115130e-03 281.76 -2.00 20.00 -2.00 321.54 0.00e+00 2.198614e-01 4.416070e-03 1.910482e-04 2.587626e-03 1.221226e-02 237.42 4.92 0.00 0.15 20.65 317.90 0.00e+00 8.577571e-05 2.151704e-04 3.754445e-06 2.387717e-05 2.816404e-04 281.76 -2.00 20.00 -2.00 317.17 0.00e+00 1.692 0.000 303.00 329.40 4 5.7604e+00 1.2673e-02 1.6303e-02 1.0000e+00 3.8002e-02 6.6735e-02 1.6918e-02 1.7648e-03 2.4183e-04 4.1030e-02 -6.5180e-04 8.9803e-03 4.7581e-04 5.8828e-05 2.2736e-02 -7.0683e-03 3.6040e-03 1.7508e-04 2.9142e-05 8.6581e-03 2.6741e-03 2.4075e-03 4.8131e-05 5.1626e-05 5.5266e-03 2.7427e-04 -1.1025e-02 2.4624e-03 1.4529e-04 1.7972e-05 3.8194e-03 -1.7121e-04 9.2063e-05 3.6192e-06 6.6415e-07 3.0249e-04 -1.1729e-02 0.0000e+00 9.2628e-01 3.1329e-01 6.6277e-03 5.8233e-04 8.3634e-01 12 8 8 10 0 0 99.91 23.15 0.18 -0.01173 -0.01303 17 3 1 5 0 2905.403 26.11 20.00 23.15 30.32 34.4 1015.29 -4640 -18 2055 -708 6477 -2901 766 2904 55 2339 -115 -1011 715 -683 -1676 -507 302 -758 -29 7 -522 268 182 243 -528 -1136 210 -170 852 844 707 -54 21 -621 -683 109 -370 267 154 586 -225 1008 594 -758 -58 323 -435 -618 271 -125 -255 948 -267 699 181 115 -506 -745 297 -21 -392 -750 -166 -33 -206 434 287 -2 -150 -174 -325 -52 342 245 866 -197 -403 250 467 436 -53 -42 5 -137 -131 -206 652 -408 -6 129 350 317 -284 19 139 -81 -211 -302 -476 -229 100 -85 292 18 -90 -35 259 132 -23 -220 -304 -545 -308 -75 398 430 -220 505 -105 -495 166 -218 -477 -46 -98 376 -80 13 538 -119 -240 232 7 20 299 -205 -89 -182 -139 272 44 122 227 175 -301 -240 -617 -2 300 -107 926 -484 138 571 12 527 -27 -249 179 -177 -438 -132 81 -216 -8 2 -150 72 47 64 -146 -338 64 -51 247 257 243 -22 10 -320 -371 60 -209 150 86 323 -122 526 307 -405 -32 189 -268 -394 175 -82 -168 614 -173 457 125 85 -394 -591 223 -15 -265 -517 -124 -27 -178 378 246 -2 -115 -121 -211 -34 238 189 724 -178 -382 247 488 479 -60 -48 6 -148 -132 -191 568 -361 -6 132 387 374 -341 22 152 -85 -219 -331 -552 -277 125 -109 391 25 -128 -50 349 166 -27 -253 -355 -669 -400 -101 540 575 -288 630 -126 -572 186 -251 -578 -58 -127 496 -108 18 787 -180 -371 362 11 31 447 -300 -130 -275 -222 459 77 229 438 344 -594 -468 SS 20230825T141912.1Z 8637.596668 409 1 50.08 2 54.57 235.44 95.31 130.53 0.00 1 0.00 1 0 49 7.547e-03 3.107e-03 6.471e-03 2.739e-03 -3.619902e-06 1.072721e-06 6.491890e-08 3.956726e-07 3.652947e-06 231.33 -2.00 3.88 -2.00 321.65 0.00e+00 1.007891e-03 3.802474e-04 4.174960e-05 1.964831e-05 9.383705e-04 281.76 -2.00 20.00 -2.00 321.45 0.00e+00 1.215494e-03 5.165262e-04 1.321033e-05 2.607798e-05 1.614030e-03 281.76 -2.00 20.00 -2.00 321.52 0.00e+00 1.174822e-03 7.439522e-04 1.184509e-04 1.402491e-05 1.705925e-03 281.76 -2.00 20.00 -2.00 321.52 0.00e+00 2.157232e-01 4.094022e-03 3.070678e-04 2.587559e-03 9.884098e-03 229.10 4.53 0.00 0.14 16.78 317.86 0.00e+00 -1.464074e-04 2.011061e-04 3.600154e-06 2.387702e-05 2.254283e-04 281.76 -2.00 20.00 -2.00 317.14 0.00e+00 1.720 0.000 303.00 329.40 4 5.7029e+00 1.0891e-02 1.6596e-02 1.0000e+00 3.0747e-02 4.0082e-02 1.5011e-02 2.2423e-03 2.4225e-04 3.3290e-02 4.0625e-03 8.1566e-03 6.8343e-04 5.8938e-05 1.8351e-02 -1.0427e-02 3.3621e-03 1.6895e-04 2.9155e-05 6.9837e-03 6.6687e-03 2.2755e-03 1.2143e-04 5.1713e-05 4.4930e-03 2.8032e-04 -9.8823e-03 2.2837e-03 1.3387e-04 1.7258e-05 2.8452e-03 -6.1198e-04 8.7349e-05 2.5159e-06 6.6772e-07 2.4384e-04 -1.2560e-02 0.0000e+00 1.6000e+00 2.9129e-01 7.8039e-03 5.6143e-04 6.5261e-01 12 9 8 11 8 0 99.98 23.16 0.38 -0.01256 -0.01723 19 4 1 5 0 2635.063 26.11 20.00 23.16 30.49 34.5 1016.37 3173 2651 1522 -655 809 658 1206 535 1922 -1060 1246 -840 -228 -3049 -1038 -231 -548 4 -67 -1970 -534 443 -2412 2294 450 224 -1711 708 -337 847 1461 -306 905 -405 441 -223 282 266 -739 43 -189 420 107 -21 -22 -124 -90 173 662 -688 -379 -131 -237 253 803 447 494 -552 125 -303 230 326 -262 -383 -372 205 -126 656 177 106 263 608 -919 -846 256 -183 317 -160 -36 -111 94 244 -167 -242 -147 -501 361 -23 -454 1 453 787 342 -120 7 -220 -77 -290 -522 -178 10 139 -21 134 -23 225 155 219 -320 -159 -431 -251 -184 118 167 343 217 168 -306 33 36 -133 -30 -436 41 -79 -217 415 5 -52 122 178 51 -244 -26 -28 -45 -89 -15 171 60 77 49 -16 73 -217 393 362 224 -99 123 107 217 108 417 -248 293 -207 -58 -810 -272 -61 -150 1 -20 -600 -155 120 -642 594 125 66 -537 213 -100 260 502 -124 420 -209 239 -125 159 150 -420 24 -103 222 56 -11 -12 -73 -55 110 427 -456 -252 -86 -155 167 554 329 383 -440 95 -216 156 224 -197 -313 -321 179 -109 538 136 75 172 395 -649 -659 216 -166 300 -159 -37 -122 107 280 -189 -262 -148 -468 316 -21 -429 1 500 923 409 -140 7 -231 -80 -317 -605 -215 13 178 -29 187 -33 316 209 276 -381 -184 -505 -307 -239 159 227 460 283 211 -370 38 40 -153 -37 -553 53 -105 -294 580 8 -78 188 278 79 -373 -40 -40 -66 -134 -24 286 106 143 94 -31 142 -421 SS 20230825T150631.4Z 8637.629530 437 1 2.19 2 60.81 247.07 90.56 139.49 0.00 1 0.00 1 0 33 4.996e-03 2.855e-03 4.983e-03 2.631e-03 8.966453e-07 1.037072e-06 3.353215e-08 3.955772e-07 2.411978e-06 231.32 -2.00 3.88 -2.00 321.16 0.00e+00 2.926178e-04 3.516223e-04 2.102026e-05 1.950844e-05 6.160595e-04 281.76 -2.00 20.00 -2.00 320.72 0.00e+00 -2.053560e-04 4.877503e-04 1.263463e-05 2.612072e-05 1.072095e-03 281.76 -2.00 20.00 -2.00 321.17 0.00e+00 1.021452e-03 6.517962e-04 8.048399e-05 1.399230e-05 1.128802e-03 281.76 -2.00 20.00 -2.00 321.03 0.00e+00 2.478932e-01 3.755795e-03 1.621266e-04 2.587531e-03 6.600290e-03 236.02 3.71 0.00 0.12 11.14 317.06 0.00e+00 2.785738e-04 1.631291e-04 2.098123e-06 2.387328e-05 1.503191e-04 281.76 -2.00 20.00 -2.00 316.40 0.00e+00 2.041 0.000 303.00 329.40 4 2.9195e+00 1.1029e-02 1.9674e-02 1.0000e+00 2.0349e-02 6.2145e-03 1.4079e-02 2.2072e-03 2.4878e-04 2.2120e-02 1.3809e-03 7.5175e-03 3.7847e-04 5.7017e-05 1.2110e-02 -3.6477e-03 3.1747e-03 5.7435e-05 2.6793e-05 4.7432e-03 1.4745e-03 2.1234e-03 1.0228e-04 4.6538e-05 3.0964e-03 3.2055e-03 -2.0250e-03 1.5162e-03 3.5702e-05 9.0507e-06 1.3451e-03 -2.1259e-04 7.9726e-05 1.8318e-06 6.8072e-07 1.6146e-04 -1.3301e-02 0.0000e+00 1.0249e-01 2.4307e-01 3.7722e-03 4.0039e-04 3.9733e-01 12 9 9 12 1 1 -75.41 23.16 0.19 -0.01330 -0.01492 6 32 1 5 0 310.841 26.11 19.99 23.16 30.97 34.3 1017.30 473 17 -195 1947 -2076 240 -307 1489 -738 403 530 -409 -1096 -274 -44 -1255 208 -793 164 -321 1076 -623 -141 1262 201 179 331 936 -718 1592 -549 12 46 -1 153 -113 683 -914 132 -726 -29 -762 790 27 487 -414 -17 281 49 341 -31 248 -63 586 240 -182 -75 23 425 10 -292 -545 87 29 -58 -436 -34 15 -333 -649 -187 143 -158 -130 298 -26 171 38 260 -74 216 -100 -15 45 184 -197 -69 -243 -881 88 -105 164 -277 304 253 300 402 -537 215 304 -374 55 695 31 -51 -34 204 -329 40 144 -210 54 -311 188 -95 182 -25 -67 78 -180 -129 -284 125 -61 175 68 -45 19 -36 -165 -2 151 17 -407 -95 357 77 172 -186 -130 -152 166 326 -73 -193 76 79 3 -38 375 -419 51 -73 384 -210 119 160 -128 -355 -90 -15 -421 71 -286 61 -120 387 -216 -48 430 73 68 131 363 -276 626 -241 6 25 -1 94 -71 432 -584 84 -461 -18 -470 480 17 314 -279 -12 200 36 249 -22 181 -46 430 183 -145 -62 20 349 8 -224 -425 72 26 -53 -403 -31 13 -280 -514 -142 108 -126 -111 272 -25 170 39 277 -82 243 -113 -16 49 191 -194 -65 -233 -888 93 -119 193 -331 355 285 324 432 -602 249 363 -460 69 897 41 -70 -45 267 -414 49 169 -251 66 -400 248 -127 238 -32 -84 95 -214 -151 -339 154 -78 228 90 -61 26 -51 -241 -3 225 26 -598 -137 505 109 249 -280 -204 -249 280 564 -128 -340 134 SS 20230825T151018.1Z 8637.632154 440 1 18.44 2 61.33 247.94 90.21 140.22 0.00 1 0.00 1 0 49 1.160e-03 5.407e-04 9.434e-04 4.160e-04 2.229446e-07 1.626066e-07 1.255875e-08 3.956231e-07 5.606846e-07 231.32 -2.00 3.88 -2.00 321.47 0.00e+00 5.083186e-04 5.675259e-05 1.100394e-05 1.959085e-05 1.429579e-04 281.76 -2.00 20.00 -2.00 321.11 0.00e+00 3.113543e-04 7.725096e-05 1.937557e-06 2.613068e-05 2.490593e-04 281.76 -2.00 20.00 -2.00 321.40 0.00e+00 1.668030e-04 1.083900e-04 2.492444e-05 1.400638e-05 2.619034e-04 281.76 -2.00 20.00 -2.00 321.33 0.00e+00 2.551187e-01 6.199909e-04 6.864537e-05 2.587656e-03 1.534063e-03 236.41 0.59 0.00 0.12 2.59 317.64 0.00e+00 2.926528e-05 2.923003e-05 1.334805e-06 2.387577e-05 3.487954e-05 281.76 -2.00 20.00 -2.00 316.95 0.00e+00 2.075 0.000 303.00 329.40 4 1.2892e+00 1.7721e-03 1.9984e-02 1.0000e+00 4.7310e-03 6.6091e-03 2.3444e-03 2.0804e-03 2.4724e-04 5.1410e-03 -3.9458e-03 1.2529e-03 2.1011e-04 5.7694e-05 2.8127e-03 -8.4094e-04 5.4441e-04 5.7147e-05 3.0372e-05 1.1079e-03 1.0542e-03 3.5373e-04 1.8222e-05 5.2498e-05 7.2336e-04 1.5901e-02 -2.4511e-03 2.6203e-04 3.4332e-05 1.0790e-05 3.0364e-04 -4.3985e-04 1.2797e-05 1.9671e-06 6.6718e-07 3.7477e-05 -1.1681e-02 0.0000e+00 2.0855e-01 3.8863e-02 1.3322e-03 3.9504e-04 9.1585e-02 12 1 1 12 1 1 99.41 23.17 0.21 -0.01168 -0.01504 338 188 1 5 0 52.359 26.11 20.00 23.17 31.07 34.4 1018.47 326 485 182 287 -60 189 -135 289 60 77 -451 -223 -131 -253 -56 144 -93 -260 149 -170 -100 -139 236 107 140 399 -19 -169 6 -135 72 53 114 -68 -94 67 99 27 -5 -73 46 -75 -89 52 -28 93 49 50 -58 49 -45 -95 -64 83 84 -9 149 8 -35 -38 -74 -105 -62 -25 26 -79 109 -32 107 7 -11 -25 -101 71 31 20 -14 46 -62 -2 -58 6 56 45 -4 -24 -49 2 -70 4 99 51 58 -9 -49 -28 14 -16 -106 -42 -31 -18 40 -40 17 59 35 5 -27 1 -24 0 -70 37 55 99 31 -50 -52 -119 80 34 -5 29 25 31 -66 -29 9 3 15 -23 -2 -10 27 14 -27 -23 -36 0 22 9 38 14 -44 6 42 69 28 45 -9 30 -24 59 13 18 -112 -57 -35 -69 -15 40 -27 -79 47 -54 -31 -40 65 31 43 130 -7 -57 2 -47 26 23 54 -36 -53 39 58 16 -3 -42 26 -42 -49 30 -17 56 31 33 -39 34 -31 -65 -44 57 61 -6 117 6 -27 -29 -54 -78 -48 -21 22 -70 94 -27 84 5 -7 -18 -78 58 27 19 -14 46 -66 -2 -65 7 62 50 -4 -23 -45 2 -70 4 109 61 71 -10 -54 -30 15 -18 -123 -51 -37 -22 54 -54 23 82 46 6 -33 2 -30 0 -92 48 72 129 41 -63 -65 -142 93 41 -6 37 33 42 -90 -42 13 4 23 -36 -4 -15 40 21 -41 -34 -55 1 38 15 69 24 -80 11 SS 20230825T154852.9Z 8637.658945 467 1 12.32 2 66.86 256.51 86.99 147.84 0.00 1 0.00 1 0 49 3.885e-03 9.359e-04 2.804e-03 8.226e-04 2.250629e-07 3.153285e-07 1.891680e-08 3.957442e-07 1.861321e-06 231.32 -2.00 3.88 -2.00 321.96 0.00e+00 4.119299e-04 1.162108e-04 7.154082e-06 1.974591e-05 4.696104e-04 281.76 -2.00 20.00 -2.00 321.75 0.00e+00 7.335989e-04 1.528119e-04 6.541791e-06 2.616917e-05 8.456017e-04 281.76 -2.00 20.00 -2.00 321.76 0.00e+00 6.480841e-04 2.378045e-04 8.068682e-05 1.408472e-05 8.764792e-04 281.76 -2.00 20.00 -2.00 321.80 0.00e+00 3.073179e-01 1.335810e-03 2.058208e-04 2.587883e-03 5.177275e-03 235.85 1.04 0.00 0.10 8.73 318.63 0.00e+00 4.460826e-05 7.465213e-05 3.487287e-06 2.388740e-05 1.175282e-04 281.76 -2.00 20.00 -2.00 317.93 0.00e+00 2.524 0.000 303.00 329.40 4 1.7314e+00 3.5530e-03 2.4323e-02 1.0000e+00 1.5867e-02 1.0042e-02 5.0755e-03 2.6964e-03 2.4666e-04 1.7239e-02 -7.4445e-03 2.6912e-03 3.8109e-04 5.8796e-05 9.3079e-03 -1.3974e-03 1.3460e-03 5.8076e-05 4.5843e-05 3.7263e-03 3.3055e-03 8.2275e-04 6.4745e-05 6.6783e-05 2.6283e-03 6.1616e-03 -1.7721e-03 4.6266e-04 4.4251e-05 1.1879e-05 6.0532e-04 -4.9705e-04 2.5737e-05 2.2496e-06 6.6947e-07 1.2573e-04 -1.1139e-02 0.0000e+00 1.3454e-01 6.9370e-02 5.1289e-04 3.6806e-04 2.7060e-01 12 1 1 12 1 1 99.97 23.17 0.19 -0.01114 -0.01493 146 118 1 5 0 83.718 26.11 20.00 23.17 29.96 34.2 1011.45 2922 627 1336 107 404 1391 -456 676 -627 989 -511 479 -115 -20 -337 -421 151 -469 65 -726 -327 -743 618 -401 20 268 -318 -253 -192 8 -724 354 -112 111 -37 -41 111 -276 203 -214 364 -152 -209 7 110 -40 39 212 -42 204 -105 284 -74 80 32 234 148 42 105 -49 -151 -201 -26 -42 83 -128 -11 -8 -11 172 -218 26 -33 7 2 -22 -51 0 -61 -15 34 39 -32 -32 120 -121 -56 -36 -48 103 161 126 61 -16 -136 -58 -33 -112 -59 -139 -22 56 127 -76 63 -98 70 -75 118 1 -114 3 -17 -61 90 147 22 76 -39 -3 32 -30 -83 -11 44 38 -19 -33 -26 10 56 18 -62 54 -53 56 -85 -46 -95 13 79 6 84 -9 -48 -3 213 52 118 10 38 143 -55 86 -91 151 -83 80 -20 -4 -61 -78 29 -97 14 -161 -69 -149 119 -81 4 64 -81 -63 -47 2 -215 116 -44 48 -16 -19 51 -128 94 -99 164 -68 -93 3 55 -21 22 124 -24 119 -62 164 -42 47 20 157 101 30 75 -33 -98 -135 -18 -33 69 -103 -9 -7 -8 117 -140 17 -24 5 2 -20 -48 0 -62 -17 36 42 -34 -33 116 -112 -49 -33 -47 107 177 152 72 -19 -151 -62 -35 -121 -68 -169 -27 72 166 -106 87 -135 95 -99 145 1 -138 3 -23 -84 124 198 29 99 -49 -4 39 -37 -107 -15 61 54 -27 -49 -39 16 90 30 -100 85 -80 86 -131 -71 -157 23 142 11 159 -17 -95 -6