File name: Pandora162s1_Brussels-Uccle_20241012_L2Fit_fwvt1c13d20231120p1-8.txt File generation date: 20241012T233523.1Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c13p1-8 Local principal investigator: Michel Van Roozendael Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 162 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora162_OF_v8d20191031.txt Instrument calibration file used: Pandora162s1_CF_v13d20231120.txt Level 1 file used: Pandora162s1_Brussels-Uccle_20241012_L1_smca1c13d20231120p1-8.txt Full location name: Uccle (BIRA-IASB, KMI-IRM) Short location name: Brussels-Uccle Country of location: Belgium Location latitude [deg]: 50.7980 Location longitude [deg]: 4.3580 Location altitude [m]: 107 Local noon date: 20241012 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Based on session 12 for fieldcal First and last pixel inside fitting window: 1648 1798 Nominal wavelengths inside fitting window [nm]: 492.0019 492.1226 492.2433 492.3640 492.4847 492.6053 492.7260 492.8466 492.9672 493.0878 493.2084 493.3289 493.4495 493.5700 493.6905 493.8110 493.9314 494.0519 494.1723 494.2927 494.4131 494.5335 494.6539 494.7742 494.8946 495.0149 495.1352 495.2555 495.3758 495.4960 495.6162 495.7365 495.8567 495.9768 496.0970 496.2172 496.3373 496.4574 496.5775 496.6976 496.8177 496.9377 497.0577 497.1778 497.2978 497.4177 497.5377 497.6577 497.7776 497.8975 498.0174 498.1373 498.2572 498.3770 498.4968 498.6166 498.7364 498.8562 498.9760 499.0957 499.2155 499.3352 499.4549 499.5746 499.6942 499.8139 499.9335 500.0531 500.1727 500.2923 500.4118 500.5314 500.6509 500.7704 500.8899 501.0094 501.1289 501.2483 501.3677 501.4871 501.6065 501.7259 501.8453 501.9646 502.0839 502.2032 502.3225 502.4418 502.5611 502.6803 502.7995 502.9187 503.0379 503.1571 503.2762 503.3954 503.5145 503.6336 503.7527 503.8718 503.9908 504.1099 504.2289 504.3479 504.4669 504.5858 504.7048 504.8237 504.9426 505.0615 505.1804 505.2993 505.4181 505.5370 505.6558 505.7746 505.8934 506.0121 506.1309 506.2496 506.3683 506.4870 506.6057 506.7244 506.8430 506.9616 507.0803 507.1988 507.3174 507.4360 507.5545 507.6731 507.7916 507.9101 508.0285 508.1470 508.2654 508.3839 508.5023 508.6207 508.7390 508.8574 508.9757 509.0941 509.2124 509.3306 509.4489 509.5672 509.6854 509.8036 509.9218 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-252: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 253-403: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20241012T080556.7Z 9051.337462 121 1 44.96 2 72.94 126.58 149.82 27.32 0.00 1 0.00 1 0 15 1.923e-03 1.921e-03 3.489e-04 3.483e-04 2.475615e+03 2.094425e+01 1.826074e+02 -6.000000e+00 1.069742e+02 276.82 -2.00 20.00 -2.00 505.25 0.00e+00 4.404102e-04 9.504687e-06 2.886828e-05 -6.000000e+00 5.363466e-05 276.82 -2.00 20.00 -2.00 500.46 0.00e+00 1.908923e-01 6.946994e-03 1.918150e-02 -6.000000e+00 3.862510e-02 224.85 -2.00 3.79 -2.00 502.05 0.00e+00 3.358 0.001 489.00 513.00 1 5.4073e+00 5.3151e-04 5.0540e-03 -6.0000e+00 2.9593e-03 4.0375e-03 1.3684e-04 5.2667e-04 -6.0000e+00 7.6533e-04 5.3613e-03 1.2237e-03 3.7289e-05 2.5032e-05 -6.0000e+00 2.1249e-04 -1.4962e-03 -5.2986e-05 10 0 0 10 0 0 98.44 18.68 1.85 -0.00150 0.00699 85 17 1 2 0 528.810 15.00 18.68 14.69 21.06 21.69 1.6 913.82 900000 -183 11 58 -110 71 365 365 349 224 212 271 -6 -65 -107 -146 -222 -96 209 -22 -208 27 115 145 350 214 11 221 80 -392 -86 -94 -302 5 255 -185 -226 13 79 -121 14 36 -5 -45 88 179 157 180 87 126 -236 -254 -337 -411 -169 -81 -159 -195 -21 -41 66 209 220 129 91 73 -60 -25 -19 -126 -413 -67 -188 -81 164 -48 -396 -263 -43 -170 -234 -157 -212 -393 -18 -55 -161 -111 -88 13 -99 -15 171 226 -7 85 161 40 -170 -173 -372 -374 -375 -104 -26 -341 -256 -115 -90 18 168 80 28 105 134 177 286 430 283 176 213 194 67 162 335 15 182 268 95 183 390 -58 -97 87 -77 -94 218 18 -140 -43 107 76 117 202 115 61 -9 -117 -351 -256 -149 900000 -178 11 57 -112 73 385 389 373 238 223 281 -6 -65 -107 -147 -225 -99 220 -23 -216 28 120 151 365 224 12 228 81 -406 -87 -95 -307 5 261 -193 -237 14 81 -123 14 37 -5 -47 92 187 164 187 88 126 -240 -252 -329 -400 -166 -82 -159 -197 -21 -42 68 213 225 132 93 74 -60 -24 -19 -126 -410 -67 -186 -78 159 -47 -383 -251 -42 -166 -228 -154 -208 -375 -17 -53 -158 -109 -87 13 -98 -15 172 230 -7 85 158 38 -160 -166 -355 -358 -352 -100 -26 -346 -259 -115 -89 17 166 80 28 104 134 178 289 435 286 176 210 189 64 162 322 15 176 259 92 176 373 -58 -95 83 -74 -90 211 17 -136 -42 106 76 117 203 116 62 -9 -115 -338 -243 -141 SQ 20241012T081315.4Z 9051.342540 125 1 49.66 2 72.02 128.22 149.27 30.29 0.00 1 0.00 1 0 15 2.760e-03 2.761e-03 1.202e-03 1.198e-03 2.277077e+03 7.369248e+01 1.753186e+02 -6.000000e+00 1.535427e+02 276.82 -2.00 20.00 -2.00 505.28 0.00e+00 4.611441e-04 3.276308e-05 2.708600e-05 -6.000000e+00 7.698534e-05 276.82 -2.00 20.00 -2.00 500.36 0.00e+00 2.086245e-01 2.414853e-02 1.625887e-02 -6.000000e+00 5.545715e-02 224.85 -2.00 3.79 -2.00 501.98 0.00e+00 3.197 0.001 489.00 513.00 1 7.5653e+00 1.8524e-03 4.7636e-03 -6.0000e+00 4.2487e-03 8.6352e-03 4.7339e-04 4.7499e-04 -6.0000e+00 1.0992e-03 6.3287e-04 1.5689e-03 1.2842e-04 2.2723e-05 -6.0000e+00 3.0504e-04 3.7093e-05 -8.6302e-05 10 0 0 10 0 0 99.85 18.68 1.93 0.00004 0.01092 14 3 1 2 0 3545.800 15.00 18.68 14.79 21.06 21.69 1.6 914.23 900000 -321 -6 -26 10 -113 625 407 404 -70 28 536 -79 -228 -346 -243 -633 -247 259 92 -297 83 52 110 792 68 207 74 -89 -190 -21 -226 -229 -115 454 -242 44 224 122 -63 -230 26 -139 -48 162 354 21 378 64 239 -112 -308 -360 -408 236 221 -267 -193 -282 41 -173 174 311 -292 186 49 -118 -68 395 -169 -289 -156 -190 -60 499 -363 -203 -543 -339 17 -506 -214 -304 -387 -58 302 -147 -88 138 50 230 -142 406 450 70 150 161 113 -120 -286 -322 -162 -434 -373 -344 -428 -262 -316 -257 277 396 -87 102 -125 81 88 395 61 526 141 401 197 190 115 78 135 -57 560 13 431 395 -164 -204 -51 -363 -314 307 -56 108 196 307 -15 -216 343 147 82 71 -50 -505 -382 -306 900000 -320 -6 -25 10 -117 657 434 432 -74 30 553 -81 -230 -347 -244 -644 -255 273 98 -322 90 56 120 856 74 224 80 -94 -196 -21 -227 -233 -120 483 -263 47 241 130 -66 -243 27 -148 -48 165 363 21 383 68 247 -113 -305 -350 -396 231 223 -276 -192 -282 41 -173 173 311 -294 185 49 -115 -69 395 -168 -285 -154 -187 -60 500 -347 -192 -537 -330 17 -490 -208 -297 -362 -54 286 -141 -84 132 48 222 -138 399 446 69 147 155 106 -111 -258 -288 -145 -397 -352 -335 -423 -258 -309 -249 265 381 -86 101 -125 83 90 404 63 536 143 400 194 185 112 77 132 -56 546 13 419 382 -158 -194 -48 -338 -294 289 -54 106 194 306 -15 -219 348 142 79 71 -49 -492 -367 -293 SQ 20241012T083922.7Z 9051.360680 138 1 44.87 2 68.93 134.26 146.93 40.23 0.00 1 0.00 1 0 15 1.856e-03 1.847e-03 4.444e-04 4.433e-04 2.264523e+03 2.666717e+01 1.668047e+02 -6.000000e+00 1.032626e+02 276.82 -2.00 20.00 -2.00 505.24 0.00e+00 3.669044e-04 1.210431e-05 2.478333e-05 -6.000000e+00 5.177309e-05 276.82 -2.00 20.00 -2.00 500.42 0.00e+00 1.477237e-01 8.876102e-03 1.744142e-02 -6.000000e+00 3.728170e-02 224.84 -2.00 3.79 -2.00 502.01 0.00e+00 2.755 0.000 489.00 513.00 1 5.8899e+00 6.7938e-04 4.1970e-03 -6.0000e+00 2.8564e-03 5.4475e-03 1.7485e-04 4.6833e-04 -6.0000e+00 7.3863e-04 3.6180e-03 9.8414e-04 4.7625e-05 2.3452e-05 -6.0000e+00 2.0510e-04 -1.7720e-03 -4.4456e-05 10 0 0 10 0 0 98.36 18.68 1.94 -0.00177 0.00505 82 17 1 2 0 547.070 15.00 18.68 15.28 21.06 21.69 1.5 917.85 900000 -44 -97 115 -130 58 407 384 228 237 129 319 3 -52 -46 -138 -124 -106 194 -86 -190 122 51 91 360 126 36 249 64 -361 -245 -26 -271 -83 232 -268 -194 68 79 -176 4 120 -29 -16 173 153 142 162 119 55 -185 -199 -350 -406 -111 2 -163 -244 -181 -48 88 200 167 82 151 56 -28 -89 -10 -180 -329 -180 -90 -101 150 41 -334 -255 -2 -75 -256 -171 -202 -392 -26 -20 -146 -245 -21 -21 56 20 215 177 31 -25 124 -1 -62 -176 -347 -309 -368 -123 -19 -284 -308 -169 -53 87 87 29 69 43 50 138 250 349 256 186 218 141 61 274 357 65 77 302 0 212 344 -54 -87 155 -153 -211 214 27 -99 -29 87 38 126 231 115 83 24 -159 -297 -255 -87 900000 -42 -95 116 -134 62 418 399 238 245 132 337 3 -53 -47 -141 -128 -111 199 -90 -201 128 54 97 381 134 38 261 66 -364 -252 -27 -268 -85 240 -285 -206 71 82 -182 4 123 -30 -17 183 162 150 170 123 56 -183 -192 -347 -402 -106 2 -164 -250 -187 -49 91 206 172 85 155 57 -28 -88 -10 -175 -316 -172 -87 -98 147 40 -326 -245 -2 -71 -242 -162 -192 -378 -25 -20 -145 -243 -21 -20 56 20 219 182 32 -26 123 -1 -59 -164 -321 -286 -348 -120 -19 -277 -301 -163 -53 86 87 28 68 43 50 139 253 354 259 186 215 137 59 263 344 63 75 292 0 204 329 -51 -82 150 -147 -204 199 25 -96 -28 86 38 126 232 116 83 24 -156 -285 -242 -82 SQ 20241012T084824.4Z 9051.366949 142 1 44.63 2 67.93 136.41 146.00 43.41 0.00 1 0.00 1 0 15 1.903e-03 1.888e-03 5.341e-04 5.325e-04 2.423136e+03 3.210442e+01 1.784924e+02 -6.000000e+00 1.058801e+02 276.82 -2.00 20.00 -2.00 505.23 0.00e+00 3.697057e-04 1.453253e-05 2.466515e-05 -6.000000e+00 5.308695e-05 276.82 -2.00 20.00 -2.00 500.40 0.00e+00 9.903734e-02 1.066820e-02 1.849602e-02 -6.000000e+00 3.823556e-02 224.84 -2.00 3.79 -2.00 501.99 0.00e+00 2.638 0.000 489.00 513.00 1 6.1658e+00 8.1703e-04 4.0790e-03 -6.0000e+00 2.9294e-03 4.6472e-03 2.1017e-04 4.8898e-04 -6.0000e+00 7.5773e-04 2.8000e-03 1.2675e-03 5.7097e-05 2.4836e-05 -6.0000e+00 2.1034e-04 -2.3406e-04 -7.0885e-05 10 0 0 10 0 0 99.82 18.69 1.92 -0.00023 0.00856 85 17 1 2 0 524.970 15.00 18.69 15.47 21.06 21.69 1.5 919.40 900000 -73 -70 57 -183 110 434 275 245 183 288 216 168 -135 -60 -200 -235 -104 169 -60 -171 119 139 76 224 203 0 139 124 -369 -50 -131 -136 -15 304 -191 -261 38 65 -164 -126 99 0 103 76 214 169 191 58 83 -226 -265 -300 -484 -92 -156 -58 -222 -129 33 -34 218 132 148 101 99 12 -53 28 -138 -331 -95 -133 -200 129 -28 -336 -330 -30 -155 -215 -106 -225 -400 -33 34 -140 -71 -92 88 18 -14 213 114 28 -11 248 12 -90 -272 -409 -302 -278 -175 4 -288 -360 -166 -160 68 174 131 -44 131 96 134 253 350 234 140 318 135 96 259 320 76 140 278 1 231 284 -34 -26 97 -174 -82 183 -10 -204 -72 89 -23 165 216 214 193 -39 -135 -379 -298 -127 900000 -70 -69 58 -191 118 447 287 257 190 296 218 177 -140 -62 -206 -245 -105 174 -63 -181 126 147 80 238 216 0 146 128 -373 -50 -129 -135 -15 316 -203 -278 40 68 -169 -129 102 0 108 80 228 180 201 60 84 -224 -256 -285 -460 -88 -154 -59 -229 -133 34 -36 226 137 154 104 102 12 -53 27 -135 -320 -91 -129 -196 127 -28 -329 -319 -29 -147 -204 -100 -216 -387 -32 33 -139 -71 -92 88 18 -14 217 112 27 -11 247 12 -86 -255 -380 -281 -264 -171 4 -281 -352 -160 -161 67 166 127 -43 130 96 135 256 355 237 141 314 131 93 249 308 74 135 268 1 223 272 -33 -24 90 -160 -76 171 -10 -198 -71 88 -23 166 217 216 194 -38 -133 -365 -282 -120 SQ 20241012T121846.4Z 9051.513037 265 1 31.56 2 59.48 194.37 116.42 93.33 0.00 1 0.00 1 0 15 1.863e-03 1.864e-03 4.380e-04 4.371e-04 2.314952e+03 2.619230e+01 1.717307e+02 -6.000000e+00 1.036464e+02 276.80 -2.00 20.00 -2.00 505.24 0.00e+00 3.389876e-04 1.192977e-05 2.351644e-05 -6.000000e+00 5.196870e-05 276.80 -2.00 20.00 -2.00 500.43 0.00e+00 3.750331e-02 8.740856e-03 1.752215e-02 -6.000000e+00 3.743089e-02 224.82 -2.00 3.79 -2.00 502.01 0.00e+00 1.961 0.000 489.00 513.00 1 5.7575e+00 6.6915e-04 3.1890e-03 -6.0000e+00 2.8677e-03 3.2170e-03 1.7238e-04 4.5003e-04 -6.0000e+00 7.4177e-04 4.6555e-03 1.2795e-03 4.6811e-05 2.3009e-05 -6.0000e+00 2.0592e-04 -1.4174e-03 -6.2614e-05 12 1 1 12 1 1 99.86 18.69 1.99 -0.00142 0.00746 61 20 1 2 0 508.910 15.00 18.69 18.70 21.06 21.69 1.4 941.49 900000 -141 -7 20 -64 34 418 358 280 189 230 205 94 -106 -63 -94 -138 -165 183 -44 -188 7 78 62 475 196 9 164 130 -407 -166 -35 -297 -70 284 -268 -286 96 31 -46 32 97 -8 56 104 266 113 74 31 43 -211 -210 -309 -390 -171 -88 -96 -191 -95 -108 31 210 200 103 78 104 -42 -72 51 -160 -367 -124 -107 -192 150 35 -279 -242 -12 -51 -238 -190 -193 -309 -141 31 -140 -111 -60 -84 -33 32 251 221 54 69 83 27 -140 -227 -296 -295 -338 -136 18 -345 -281 -111 -218 111 158 -13 -44 61 181 102 278 308 267 121 311 157 90 272 351 -21 131 279 45 217 267 -18 -100 164 -91 -123 284 -39 -101 -110 -42 -57 168 236 91 92 83 -175 -339 -162 -61 900000 -138 -7 20 -66 35 443 370 291 203 243 214 97 -108 -64 -95 -140 -171 194 -45 -197 7 82 65 499 206 9 170 133 -423 -168 -35 -303 -71 293 -282 -302 100 32 -47 33 99 -8 58 109 279 119 77 32 43 -214 -208 -301 -380 -169 -89 -96 -195 -97 -111 31 215 205 106 80 105 -42 -71 50 -159 -364 -123 -106 -185 146 34 -270 -231 -12 -50 -231 -185 -190 -295 -136 30 -138 -109 -59 -83 -33 32 253 225 55 70 82 26 -132 -218 -282 -281 -317 -132 18 -337 -274 -111 -216 109 156 -13 -43 61 181 103 281 312 270 122 307 153 87 261 337 -20 127 269 43 208 255 -17 -97 157 -87 -117 273 -37 -98 -108 -41 -57 168 237 92 93 82 -171 -325 -153 -57