File name: Pandora206s1_BuffaloNY_20250412_L2Fit_fsus1c6d20240814p1-8.txt File generation date: 20250413T052239.1Z Data description: Level 2 spectral fitting results file Data file version: fsus1c6p1-8 Local principal investigator: Kang Sun Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 206 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora206_OF_v3d20211008.txt Instrument calibration file used: Pandora206s1_CF_v6d20240814.txt Level 1 file used: Pandora206s1_BuffaloNY_20250412_L1_smca1c6d20240814p1-8.txt Full location name: University at Buffalo Short location name: BuffaloNY Country of location: United States Location latitude [deg]: 43.0015 Location longitude [deg]: -78.7869 Location altitude [m]: 190 Local noon date: 20250412 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 230 375 Nominal wavelengths inside fitting window [nm]: 306.0215 306.1624 306.3033 306.4442 306.5850 306.7259 306.8668 307.0076 307.1484 307.2893 307.4301 307.5709 307.7117 307.8524 307.9932 308.1340 308.2747 308.4154 308.5561 308.6968 308.8375 308.9782 309.1189 309.2596 309.4002 309.5408 309.6815 309.8221 309.9627 310.1033 310.2438 310.3844 310.5250 310.6655 310.8060 310.9466 311.0871 311.2276 311.3681 311.5085 311.6490 311.7894 311.9299 312.0703 312.2107 312.3511 312.4915 312.6319 312.7723 312.9126 313.0530 313.1933 313.3336 313.4740 313.6143 313.7545 313.8948 314.0351 314.1753 314.3156 314.4558 314.5960 314.7362 314.8764 315.0166 315.1568 315.2970 315.4371 315.5772 315.7174 315.8575 315.9976 316.1377 316.2777 316.4178 316.5579 316.6979 316.8379 316.9780 317.1180 317.2580 317.3980 317.5379 317.6779 317.8178 317.9578 318.0977 318.2376 318.3775 318.5174 318.6573 318.7972 318.9370 319.0769 319.2167 319.3565 319.4963 319.6361 319.7759 319.9157 320.0554 320.1952 320.3349 320.4747 320.6144 320.7541 320.8938 321.0335 321.1731 321.3128 321.4524 321.5921 321.7317 321.8713 322.0109 322.1505 322.2900 322.4296 322.5692 322.7087 322.8482 322.9877 323.1272 323.2667 323.4062 323.5457 323.6851 323.8246 323.9640 324.1034 324.2428 324.3822 324.5216 324.6610 324.8003 324.9397 325.0790 325.2184 325.3577 325.4970 325.6363 325.7755 325.9148 326.0541 326.1933 326.3325 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Spectrometer control temperature [°C], 999=no temperature signal Column 155: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 156: Temperature in head sensor [°C], 999=no temperature signal Column 157: Temperature at electronics board 1 [°C], 999=no temperature signal Column 158: Temperature at electronics board 2 [°C], 999=no temperature signal Column 159: Humidity in head sensor [%], -9=no humidity signal Column 160: Pressure in head sensor [hPa], -9=no pressure signal Columns 161-306: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 307-452: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20250412T165604.2Z 9233.705604 373 1 24.00 2 34.32 171.32 147.02 358.18 0.00 1 0.00 1 0 49 5.374e-02 1.803e-02 6.273e-02 1.771e-02 -7.456243e-06 6.542979e-06 2.396275e-07 4.241966e-07 2.325331e-05 228.02 -2.00 3.55 -2.00 322.13 0.00e+00 4.645287e-03 2.430323e-03 9.633610e-05 1.924523e-05 6.184663e-03 277.57 -2.00 20.00 -2.00 322.21 0.00e+00 3.112502e-03 3.281196e-03 9.902188e-05 2.832416e-05 1.121796e-02 277.57 -2.00 20.00 -2.00 321.88 0.00e+00 8.280163e-03 5.207436e-03 5.576049e-04 7.464762e-06 1.161910e-02 277.57 -2.00 20.00 -2.00 322.00 0.00e+00 2.546279e-01 2.474211e-02 1.199227e-03 5.995379e-03 6.434088e-02 202.56 22.15 0.00 0.25 112.24 318.65 0.00e+00 6.113294e-04 1.644127e-03 3.147304e-05 5.131633e-05 1.663844e-03 277.57 -2.00 20.00 -2.00 317.63 0.00e+00 1.210 0.000 303.00 329.40 4 7.9692e+00 5.3791e-02 1.2566e-02 2.1485e-03 2.0198e-01 1.1079e-02 8.1856e-02 6.6819e-03 3.0302e-04 2.1698e-01 5.3471e-03 4.6650e-02 2.2604e-03 1.1111e-04 1.1821e-01 -2.5322e-03 2.1966e-02 8.7595e-04 5.6608e-05 4.2462e-02 3.1783e-03 1.5431e-02 6.6516e-04 6.6428e-05 3.2047e-02 3.8300e-05 3.2561e-02 1.6740e-02 5.0266e-04 2.0595e-05 7.9645e-03 -7.2291e-04 5.4842e-04 1.0468e-05 8.9369e-07 1.5505e-03 -2.7055e-03 0.0000e+00 4.0608e+00 1.8575e+00 1.4430e-02 5.5456e-04 4.2825e+00 12 8 8 10 0 0 -5.79 17.86 2.60 -0.00271 -0.00822 6 6 2 8 0 4000.000 15.00 17.86 12.98 21.48 21.27 24.8 1008.28 -5995 -19356 11765 26259 6038 -11097 3634 350 2474 22050 -7174 6653 -4837 15741 -12181 12043 689 -2578 -7987 -1507 -5648 4205 12458 2901 3079 -6822 8253 -10189 -2933 -9527 656 -1452 -999 293 1467 7069 323 4180 1125 1888 -4481 7352 -2803 3424 -3643 3134 -604 4995 -714 2040 3272 -4928 -4604 -795 3434 411 3316 -2637 1283 -4276 -1538 -3043 -6379 5462 -1683 2860 -1205 -8 -4090 3413 -891 -863 -5061 2054 631 -334 538 2306 3117 -494 489 -1200 750 -2191 -24 -85 -125 -2460 -721 341 1650 766 -1107 3019 -391 273 -1304 1019 -2098 -614 1326 898 219 1435 2398 -2864 -331 1860 1449 -1614 -960 -617 -484 160 -835 920 1098 -3387 526 848 1885 -1668 -1576 475 811 360 -2076 -756 -661 620 858 1206 153 -261 -369 793 -407 -383 -558 -350 480 1455 517 -880 730 -1114 -461 -1959 911 1677 510 -1280 412 48 378 2833 -1339 1102 -941 2476 -2612 2034 136 -553 -1885 -338 -1293 781 2016 551 627 -1676 1858 -2691 -678 -2589 182 -492 -391 126 654 3065 153 1934 538 881 -2163 3064 -1281 1520 -1867 1574 -333 2709 -415 1174 1861 -2985 -2751 -467 2058 276 2310 -1988 860 -2798 -943 -1929 -4727 3982 -1388 2267 -961 -6 -2845 2041 -524 -518 -3466 1481 512 -296 488 2181 3135 -539 527 -1324 810 -2238 -22 -74 -102 -2151 -664 346 1845 930 -1356 3332 -416 268 -1305 1088 -2447 -735 1636 1160 301 1993 3366 -4113 -447 2255 1691 -1919 -1135 -776 -651 221 -1149 1216 1383 -4309 615 937 2033 -1988 -2006 625 1106 485 -2938 -1120 -1032 983 1387 1968 246 -405 -556 1184 -602 -600 -950 -640 901 2883 1062 -1863 1508 -2299 SS 20250412T181817.1Z 9233.762698 419 1 24.00 2 36.67 206.44 143.48 32.13 0.00 1 0.00 1 0 49 4.177e-02 1.447e-02 3.815e-02 1.216e-02 -8.965656e-06 4.478653e-06 1.739367e-07 4.241810e-07 1.847481e-05 228.02 -2.00 3.55 -2.00 322.01 0.00e+00 2.755240e-03 1.655274e-03 5.879480e-05 1.924020e-05 4.852033e-03 277.58 -2.00 20.00 -2.00 322.04 0.00e+00 4.100838e-03 2.232483e-03 5.507100e-05 2.831186e-05 8.732289e-03 277.58 -2.00 20.00 -2.00 321.80 0.00e+00 4.204102e-03 3.502682e-03 3.183362e-04 7.371095e-06 9.030711e-03 277.58 -2.00 20.00 -2.00 321.89 0.00e+00 2.416888e-01 1.681234e-02 6.868664e-04 5.995594e-03 5.033590e-02 205.14 15.96 0.00 0.33 88.43 318.44 0.00e+00 -2.651987e-04 1.074679e-03 6.812511e-05 5.131153e-05 1.284316e-03 277.58 -2.00 20.00 -2.00 317.44 0.00e+00 1.246 0.000 303.00 329.40 4 7.6036e+00 3.7129e-02 1.2230e-02 2.1483e-03 1.5936e-01 -2.8877e-02 5.6063e-02 4.0029e-03 3.0331e-04 1.7012e-01 3.4764e-02 3.1824e-02 1.4200e-03 1.0866e-04 9.2843e-02 -7.9348e-03 1.4846e-02 4.8386e-04 5.1912e-05 3.4478e-02 4.0923e-03 1.0411e-02 1.6144e-04 6.4061e-05 2.4941e-02 5.9549e-05 1.1935e-02 1.0348e-02 3.1167e-04 1.9870e-05 8.3637e-03 -5.9330e-04 3.6448e-04 5.9820e-06 8.8577e-07 1.1933e-03 4.6362e-04 0.0000e+00 2.3706e+00 1.2477e+00 7.3047e-03 5.7688e-04 3.3633e+00 12 8 8 10 0 0 -61.76 17.88 1.92 0.00046 -0.00406 6 6 2 8 0 4000.000 15.00 17.88 14.34 21.48 21.27 24.9 1016.99 1196 -13020 22575 7906 15093 -12827 6629 -3710 -219 -294 -2940 391 -5802 12646 -6163 16130 -3181 5852 -3576 6248 -4850 520 629 -6528 -4692 -4542 1429 -17 2655 -4340 4 4131 2598 -191 208 2412 3944 -1379 -111 -4133 -682 5452 -3142 3803 -605 -507 434 5826 -945 1165 -1606 -3047 -5157 995 1303 -2807 2457 -2054 1944 -2486 804 -2160 -1419 1416 663 -276 243 -1462 1528 878 1274 -1116 -5129 1311 545 1629 1080 -312 1809 495 -1251 46 331 -394 -654 820 -1153 -1968 440 -238 1305 636 1162 445 824 -461 -1328 257 -1476 572 909 273 326 931 936 -763 -799 1533 -357 -547 -2123 -6 -1419 417 -3 1313 801 -4133 18 -524 1293 -1728 1887 -1048 -88 7 -1471 -1133 -4 2181 372 322 -84 936 -1062 1870 -1250 538 -494 434 1078 38 1113 -754 -383 -885 101 -1451 1862 772 1357 -1739 837 -595 -37 -52 -567 76 -1228 2264 -1332 2780 -715 1259 -882 1420 -1169 108 125 -1462 -1101 -1144 365 -4 626 -1161 1 1376 1049 -88 100 1168 1906 -694 -55 -2103 -324 2382 -1474 1726 -308 -271 243 3214 -565 696 -989 -1862 -3188 590 822 -2000 1776 -1532 1327 -1635 493 -1397 -1033 1112 533 -234 197 -1134 1036 558 758 -693 -3622 980 454 1453 1001 -302 1843 536 -1422 51 359 -396 -621 701 -953 -1713 414 -249 1453 767 1376 498 883 -465 -1367 286 -1714 678 1127 355 446 1297 1327 -1097 -1072 1903 -419 -637 -2600 -8 -1918 571 -4 1722 1042 -5291 21 -586 1444 -2057 2313 -1393 -120 9 -2046 -1667 -6 3362 597 524 -133 1420 -1597 2744 -1866 837 -844 765 2017 74 2207 -1546 -774 -1760 SS 20250412T192828.8Z 9233.811445 462 1 24.01 2 44.66 230.24 135.21 54.43 0.00 1 0.00 1 0 49 4.484e-02 1.619e-02 6.038e-02 1.471e-02 -4.989231e-06 5.434592e-06 3.730357e-07 4.242380e-07 1.982744e-05 228.02 -2.00 3.55 -2.00 322.26 0.00e+00 2.969491e-03 2.044196e-03 6.590564e-05 1.930368e-05 5.188553e-03 277.58 -2.00 20.00 -2.00 322.38 0.00e+00 -6.774509e-05 2.747049e-03 1.810426e-04 2.833173e-05 9.384608e-03 277.58 -2.00 20.00 -2.00 321.98 0.00e+00 1.412069e-02 4.579086e-03 6.599173e-04 7.531755e-06 9.693607e-03 277.58 -2.00 20.00 -2.00 322.13 0.00e+00 2.290163e-01 1.884596e-02 1.617186e-03 5.995124e-03 5.406889e-02 164.79 17.85 0.00 0.85 94.04 318.84 0.00e+00 -1.014690e-05 1.497333e-03 4.539565e-04 5.129180e-05 1.395719e-03 277.58 -2.00 20.00 -2.00 317.97 0.00e+00 1.404 0.000 303.00 329.40 4 7.5878e+00 4.6245e-02 1.5765e-02 2.1483e-03 1.6959e-01 -1.3023e-01 5.4168e-02 1.1352e-02 3.0314e-04 1.8204e-01 8.5143e-02 3.4768e-02 4.1301e-03 1.1195e-04 9.9262e-02 -1.3417e-02 1.9675e-02 1.0652e-03 6.8889e-05 3.8329e-02 -8.1701e-03 1.3471e-02 4.9560e-04 7.2994e-05 2.8047e-02 4.6632e-05 4.3622e-02 1.4911e-02 4.2038e-04 2.2484e-05 7.8502e-03 -8.0028e-04 4.5024e-04 1.0734e-05 8.9855e-07 1.2963e-03 -6.9455e-03 0.0000e+00 2.7140e+00 1.4951e+00 1.1952e-02 5.5291e-04 3.5900e+00 12 8 8 10 0 0 -5429.23 17.89 1.55 -0.00695 -0.01305 6 6 2 8 0 4000.000 15.00 17.89 17.09 21.48 21.27 25.2 1036.13 -13403 -19148 -4956 3379 -1500 -2469 8367 -5637 9736 6007 2750 -4017 -2029 13515 1980 7992 -899 -100 -5353 17214 -4950 9231 1424 -5054 -8724 769 -4938 2248 -5348 -4489 1441 1623 1733 -1163 224 3554 3487 2415 783 -3750 1387 -9474 2983 -127 2042 -5121 22426 1319 -2695 120 -1198 -2850 -4863 418 1414 -525 1130 -794 -2972 183 -474 -2758 -4194 653 -1316 1510 3933 -234 1099 106 210 -2636 -3418 1372 3526 734 660 557 1452 2096 -701 304 818 -393 -1305 978 -2606 -2612 -1109 -758 213 1378 1279 458 467 -4 2 -1256 -1906 -722 2116 997 345 537 554 -535 -293 1629 194 -2003 -1395 251 -1147 208 -1814 752 174 -3872 -666 1648 1673 411 -17 21 1412 -1075 -1293 -436 516 -111 667 945 404 88 -55 817 -629 672 -661 292 -57 1274 -310 493 -531 -937 -820 -1507 -361 220 -105 -201 707 -684 1129 786 387 -641 -325 1829 306 1157 -156 -18 -1090 2748 -973 1420 229 -891 -1730 148 -1121 465 -1138 -1032 345 466 602 -471 94 1485 1482 1023 338 -1684 573 -4324 1168 -53 900 -2574 9159 686 -1482 65 -665 -1574 -2713 226 811 -336 770 -568 -2021 111 -277 -1675 -2923 482 -1043 1172 2874 -168 726 64 119 -1561 -2314 973 2724 636 591 529 1466 2202 -757 327 873 -390 -1194 828 -2174 -2278 -1023 -777 242 1620 1542 522 493 -3 2 -1369 -2220 -867 2600 1298 463 766 811 -769 -392 2023 225 -2344 -1675 317 -1568 290 -2549 1007 224 -4876 -801 1836 1834 489 -21 27 1901 -1508 -1862 -661 818 -177 1075 1541 665 139 -84 1206 -953 1065 -1118 527 -111 2541 -650 1042 -1127 -1955 SS 20250412T201217.6Z 9233.841871 486 1 45.85 2 51.30 241.78 128.66 65.29 0.00 1 0.00 1 0 49 6.302e-03 1.423e-03 6.326e-03 1.491e-03 -3.980286e-07 5.485307e-07 8.686525e-09 4.242806e-07 2.859792e-06 228.03 -2.00 3.55 -2.00 322.42 0.00e+00 5.576390e-05 2.071389e-04 6.152879e-06 1.928599e-05 7.363359e-04 277.59 -2.00 20.00 -2.00 322.58 0.00e+00 6.075287e-04 2.741311e-04 3.175645e-06 2.833925e-05 1.328391e-03 277.59 -2.00 20.00 -2.00 322.11 0.00e+00 -7.242916e-05 4.550390e-04 4.444555e-05 7.493186e-06 1.361998e-03 277.59 -2.00 20.00 -2.00 322.27 0.00e+00 3.074604e-01 2.357718e-03 1.670690e-04 5.995673e-03 7.656798e-03 227.04 1.82 0.00 0.19 13.40 319.23 0.00e+00 -9.542065e-05 1.617555e-04 4.264619e-06 5.129506e-05 1.928251e-04 277.59 -2.00 20.00 -2.00 318.16 0.00e+00 1.596 0.000 303.00 329.40 4 3.8571e+00 5.5500e-03 1.5187e-02 2.1488e-03 2.4096e-02 2.2172e-02 8.8147e-03 1.7067e-03 3.0673e-04 2.5827e-02 -3.6235e-03 4.6805e-03 3.0421e-04 1.1210e-04 1.4074e-02 -2.7182e-03 2.3616e-03 4.8294e-05 7.2386e-05 5.6283e-03 4.1578e-03 1.4681e-03 4.1725e-05 7.4542e-05 4.0324e-03 1.7514e-03 1.8720e-03 1.1291e-03 2.5642e-05 2.2166e-05 1.1740e-03 -3.8512e-04 4.4409e-05 1.3285e-06 8.8942e-07 1.8148e-04 -3.6189e-03 0.0000e+00 -1.5049e-02 1.4023e-01 9.2303e-04 6.1744e-04 4.8267e-01 11 8 0 10 0 0 99.97 17.91 0.25 -0.00362 -0.00656 332 103 1 8 0 138.090 15.00 17.91 18.10 21.48 21.27 25.5 1043.66 -3637 2183 -1483 3095 -999 359 -1651 -89 234 -757 626 -1359 407 -26 605 456 407 -611 623 -424 532 -677 -1069 530 120 582 147 2030 -966 757 -1075 504 -282 439 -492 90 32 231 303 -406 34 -259 -72 -360 778 -374 189 -85 279 211 187 -326 42 -369 -162 146 -310 104 -179 434 -322 193 -215 60 -201 223 -282 95 -104 -152 188 -242 406 85 212 -232 -8 -55 198 31 -82 -134 -131 290 -68 86 -117 194 96 212 -192 94 -66 -53 -122 166 28 -81 5 0 27 4 162 -220 194 -104 124 -37 40 -33 -73 -62 -20 85 -43 43 -54 41 -53 -58 2 -31 -204 133 -49 75 -98 -123 -55 39 124 -37 111 8 43 -5 -75 -105 59 15 73 51 -48 73 -29 -78 -216 138 -106 213 -72 29 -156 -9 28 -97 82 -191 58 -4 88 67 64 -103 109 -77 90 -107 -164 85 21 110 30 392 -182 152 -252 139 -94 162 -192 36 13 93 122 -164 13 -100 -28 -145 336 -172 92 -43 144 112 100 -170 21 -192 -91 88 -204 71 -113 252 -183 113 -144 45 -157 175 -214 67 -66 -87 101 -134 255 61 169 -202 -7 -49 189 31 -85 -140 -133 270 -63 73 -94 163 90 221 -208 110 -76 -58 -133 166 28 -84 5 -1 32 5 218 -316 285 -148 165 -45 45 -37 -85 -78 -27 118 -58 57 -69 49 -66 -67 2 -38 -255 175 -67 105 -141 -188 -89 64 210 -63 186 13 67 -7 -115 -171 106 27 141 106 -103 160 -62 -166 SS 20250412T212023.6Z 9233.889162 530 1 46.58 2 62.91 256.33 117.42 79.18 0.00 1 0.00 1 0 49 3.492e-03 5.752e-04 1.445e-03 2.511e-04 1.064001e-06 9.098207e-08 4.790793e-08 4.243307e-07 1.570493e-06 228.03 -2.00 3.55 -2.00 322.46 0.00e+00 -3.421184e-05 3.485267e-05 2.414003e-05 1.932540e-05 4.031759e-04 277.59 -2.00 20.00 -2.00 322.58 0.00e+00 3.543180e-04 4.588833e-05 8.947312e-06 2.840547e-05 7.487669e-04 277.59 -2.00 20.00 -2.00 322.14 0.00e+00 -3.769131e-04 7.951036e-05 4.043770e-05 7.522456e-06 7.542809e-04 277.59 -2.00 20.00 -2.00 322.30 0.00e+00 4.009074e-01 4.139487e-04 1.520554e-04 5.995601e-03 4.282497e-03 229.80 0.24 0.00 0.14 7.44 319.52 0.00e+00 5.118914e-05 3.054632e-05 4.099048e-05 5.125461e-05 1.076790e-04 277.59 -2.00 20.00 -2.00 318.50 0.00e+00 2.184 0.000 303.00 329.40 4 2.7142e-01 9.7658e-04 2.0785e-02 2.1503e-03 1.3385e-02 5.7751e-03 1.5747e-03 2.4206e-03 3.0885e-04 1.4336e-02 -1.2448e-02 8.2559e-04 2.2337e-04 1.1607e-04 7.7700e-03 7.1446e-03 5.0289e-04 3.0226e-04 1.0030e-04 3.1828e-03 -1.2982e-03 2.9472e-04 3.9499e-05 8.8837e-05 2.4660e-03 3.2978e-02 -2.4111e-03 1.1897e-04 5.2257e-05 1.6294e-05 3.1442e-04 -4.3056e-04 7.3463e-06 1.7346e-06 8.7710e-07 1.0072e-04 -2.6900e-03 0.0000e+00 -2.9625e-01 1.9408e-02 7.4843e-04 5.2259e-04 2.3265e-01 10 0 0 10 0 0 99.44 17.90 0.33 -0.00269 -0.00598 1692 523 2 8 0 27.030 15.00 17.90 17.84 21.48 21.27 25.3 1041.10 -696 -2170 -562 -1816 -725 -529 681 432 286 472 844 1253 433 680 -30 464 101 599 -113 -39 -349 -175 -309 -72 -48 -69 186 -60 -180 -841 -290 -302 69 -46 77 -42 98 137 4 -45 -152 -73 -289 -64 -70 -48 -96 62 0 162 130 6 -219 -224 -176 -8 152 53 36 58 89 26 185 86 87 -35 -51 -60 -34 59 27 32 -10 77 97 82 -98 -80 -86 -11 -94 -76 10 78 144 124 147 59 136 -44 -16 -77 -28 -54 -19 -13 42 51 11 -23 -35 -42 -40 -18 -33 -16 -33 15 -18 49 58 -14 -26 2 21 9 44 1 61 -80 17 -38 -39 17 19 34 -17 -13 11 -9 9 44 -9 25 -48 12 37 -13 -3 -12 8 15 -6 -2 2 -19 -27 -96 -27 -89 -36 -30 45 33 25 45 84 132 48 77 -3 53 13 80 -16 -6 -48 -23 -39 -10 -7 -12 35 -11 -31 -157 -62 -71 19 -15 26 -15 35 48 1 -16 -53 -26 -103 -24 -29 -21 -45 31 0 78 62 3 -110 -115 -89 -5 92 34 21 33 49 15 123 64 63 -25 -38 -42 -21 34 15 18 -7 58 76 70 -87 -76 -81 -11 -97 -78 10 77 131 104 119 51 132 -44 -19 -90 -33 -63 -20 -13 41 56 13 -28 -42 -52 -54 -25 -46 -22 -46 19 -21 59 72 -19 -37 2 29 12 58 1 73 -97 20 -47 -52 25 27 50 -26 -20 18 -15 15 74 -15 39 -77 18 59 -21 -5 -22 15 29 -13 -3 3 -40 SS 20250412T212611.8Z 9233.893192 533 1 26.91 2 63.94 257.45 116.42 80.25 0.00 1 0.00 1 0 49 5.941e-02 5.225e-03 7.266e-02 6.216e-03 1.446887e-06 2.289638e-06 1.767489e-07 4.245251e-07 2.531674e-05 228.03 -2.00 3.55 -2.00 323.11 0.00e+00 7.312429e-04 9.170175e-04 7.887131e-05 1.930233e-05 6.814163e-03 277.59 -2.00 20.00 -2.00 323.56 0.00e+00 1.023465e-03 1.199703e-03 3.006669e-05 2.841098e-05 1.250543e-02 277.59 -2.00 20.00 -2.00 322.64 0.00e+00 2.192485e-03 2.389285e-03 4.443341e-04 8.779809e-06 1.283248e-02 277.59 -2.00 20.00 -2.00 322.95 0.00e+00 3.945240e-01 1.139134e-02 1.443601e-03 5.993254e-03 7.251743e-02 219.01 6.54 0.00 0.14 124.08 320.59 0.00e+00 5.851065e-04 1.031064e-03 2.297338e-04 5.119398e-05 1.813062e-03 277.59 -2.00 20.00 -2.00 319.56 0.00e+00 2.263 0.000 303.00 329.40 4 5.0460e+00 2.2305e-02 2.1634e-02 2.1502e-03 2.2515e-01 -1.4804e-02 4.2044e-02 8.1679e-03 3.0891e-04 2.4188e-01 1.1313e-02 2.2899e-02 2.2298e-03 1.2311e-04 1.3194e-01 5.5759e-03 1.5472e-02 1.3503e-03 1.3582e-04 4.5604e-02 -4.5987e-03 8.4336e-03 4.7500e-04 1.0518e-04 3.6025e-02 2.5106e-04 8.0476e-03 4.3965e-03 2.6061e-04 1.9639e-05 1.3841e-03 -2.8114e-04 1.9993e-04 6.4691e-06 8.8990e-07 1.7192e-03 -5.6641e-03 0.0000e+00 9.9043e-01 4.9465e-01 2.5381e-03 7.2993e-04 3.7973e+00 12 8 8 10 0 0 99.99 17.90 0.53 -0.00566 -0.00781 53 53 2 8 0 507.580 15.00 17.90 18.34 21.48 21.27 25.7 1046.32 -12334 -10693 51160 -20967 -7676 1756 -3525 2365 -3054 4820 -4478 16888 -6770 5736 -5452 7080 1040 -3525 -54 -8773 -3544 -3057 2279 1461 539 -2468 2328 16454 -13819 -3381 2021 4278 677 1900 1193 770 -961 2891 171 1274 -546 4858 -2180 1513 1542 -2377 264 957 515 -1269 800 -2118 -149 -1727 640 -761 387 -1152 786 -344 428 -2524 -200 1282 -1119 1265 -235 551 74 -1727 -456 451 -707 519 1211 227 68 -108 -722 -254 354 -402 -116 -158 -94 104 239 372 107 235 -91 95 286 -810 -213 660 -206 818 303 74 -72 676 -114 -510 60 -221 604 140 635 216 -306 -1274 132 122 -30 24 205 -928 174 635 41 -206 -469 163 -81 -415 -360 131 353 411 -168 201 10 39 21 -603 -168 95 16 21 373 -74 173 -49 123 -297 -257 -254 626 -657 -211 51 -136 102 -161 253 -277 878 -477 366 -391 450 77 -293 -5 -839 -307 -245 176 125 51 -266 264 1599 -1698 -406 265 663 132 413 277 187 -244 700 43 317 -137 1159 -564 401 448 -769 89 338 187 -482 299 -793 -54 -646 252 -335 185 -565 369 -154 188 -1187 -105 718 -675 775 -140 304 37 -793 -198 203 -372 310 807 162 51 -86 -618 -226 324 -373 -104 -130 -74 76 168 278 90 216 -94 108 321 -864 -208 606 -191 823 314 80 -83 815 -149 -699 85 -307 810 175 735 249 -368 -1653 180 170 -41 32 260 -1161 206 714 46 -253 -612 226 -119 -625 -559 217 594 710 -297 359 18 67 34 -962 -272 165 30 41 800 -166 406 -119 298 -710