File name: Pandora17s1_Busan_20170811_L2Fit_ffus5c2d20160407p1-8.txt
File generation date: 20250115T072142.1Z
Data description: Level 2 spectral fitting results file
Data file version: ffus5c2p1-8
Local principal investigator: Nader Abuhassan
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 17
Spectrometer number: 1
Processing software version used: BlickP v1.8.70
Instrument operation file used: Pandora17_OF_v1d20160305.txt
Instrument calibration file used: Pandora17s1_CF_v2d20160407.txt
Level 1 file used: Pandora17s1_Busan_20170811_L1_smca1c2d20160407p1-8.txt
Full location name: Busan/South Korea
Short location name: Busan
Country of location: South Korea
Location latitude [deg]: 35.2353
Location longitude [deg]: 129.0825
Location altitude [m]: 228
Local noon date: 20170811
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method)
Data caveats: Based on session 1 analab for fieldcal
First and last pixel inside fitting window: 351 616
Nominal wavelengths inside fitting window [nm]: 322.5969 322.7366 322.8763 323.0159 323.1556 323.2952 323.4348 323.5745 323.7141 323.8536 323.9932 324.1328 324.2723 324.4119 324.5514 324.6909 324.8304 324.9699 325.1094 325.2488 325.3883 325.5277 325.6672 325.8066 325.9460 326.0854 326.2248 326.3641 326.5035 326.6428 326.7821 326.9215 327.0608 327.2001 327.3393 327.4786 327.6179 327.7571 327.8963 328.0356 328.1748 328.3140 328.4531 328.5923 328.7315 328.8706 329.0097 329.1489 329.2880 329.4271 329.5662 329.7052 329.8443 329.9833 330.1224 330.2614 330.4004 330.5394 330.6784 330.8174 330.9563 331.0953 331.2342 331.3732 331.5121 331.6510 331.7899 331.9288 332.0676 332.2065 332.3453 332.4842 332.6230 332.7618 332.9006 333.0394 333.1781 333.3169 333.4557 333.5944 333.7331 333.8718 334.0105 334.1492 334.2879 334.4265 334.5652 334.7038 334.8425 334.9811 335.1197 335.2583 335.3969 335.5354 335.6740 335.8125 335.9511 336.0896 336.2281 336.3666 336.5051 336.6435 336.7820 336.9205 337.0589 337.1973 337.3357 337.4741 337.6125 337.7509 337.8893 338.0276 338.1660 338.3043 338.4426 338.5809 338.7192 338.8575 338.9958 339.1340 339.2723 339.4105 339.5487 339.6869 339.8251 339.9633 340.1015 340.2397 340.3778 340.5159 340.6541 340.7922 340.9303 341.0684 341.2065 341.3445 341.4826 341.6206 341.7587 341.8967 342.0347 342.1727 342.3107 342.4486 342.5866 342.7246 342.8625 343.0004 343.1383 343.2762 343.4141 343.5520 343.6899 343.8277 343.9656 344.1034 344.2412 344.3790 344.5168 344.6546 344.7924 344.9301 345.0679 345.2056 345.3433 345.4810 345.6187 345.7564 345.8941 346.0317 346.1694 346.3070 346.4447 346.5823 346.7199 346.8575 346.9951 347.1326 347.2702 347.4077 347.5452 347.6828 347.8203 347.9578 348.0953 348.2327 348.3702 348.5076 348.6451 348.7825 348.9199 349.0573 349.1947 349.3321 349.4694 349.6068 349.7441 349.8814 350.0188 350.1561 350.2934 350.4306 350.5679 350.7052 350.8424 350.9796 351.1169 351.2541 351.3913 351.5284 351.6656 351.8028 351.9399 352.0770 352.2142 352.3513 352.4884 352.6255 352.7625 352.8996 353.0367 353.1737 353.3107 353.4477 353.5847 353.7217 353.8587 353.9957 354.1326 354.2696 354.4065 354.5434 354.6803 354.8172 354.9541 355.0909 355.2278 355.3646 355.5015 355.6383 355.7751 355.9119 356.0487 356.1854 356.3222 356.4590 356.5957 356.7324 356.8691 357.0058 357.1425 357.2792 357.4158 357.5525 357.6891 357.8257 357.9623 358.0989 358.2355 358.3721 358.5087 358.6452 358.7818 358.9183 359.0548 359.1913
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Bromine oxide effective temperature [K]
Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Formaldehyde effective temperature [K]
Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Nitrous acid effective temperature [K]
Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 60: Nitrogen dioxide effective temperature [K]
Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful
Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 71: Oxygen dimer effective temperature [K]
Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful
Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 82: Ozone effective temperature [K]
Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 93: Sulfur dioxide effective temperature [K]
Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful
Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 101: Lower limit used for wavelength scaling [nm]
Column 102: Upper limit used for wavelength scaling [nm]
Column 103: Order of smoothing polynomial
Column 104: Smoothing polynomial coefficient, order 0
Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 109: Smoothing polynomial coefficient, order 1
Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 114: Smoothing polynomial coefficient, order 2
Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 119: Smoothing polynomial coefficient, order 3
Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 124: Smoothing polynomial coefficient, order 4
Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 129: Mean value of measured data inside fitting window [same units as measurements]
Column 130: Offset polynomial coefficient, order 0
Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 135: Wavelength change polynomial coefficient, order 0
Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 142: Resolution change polynomial coefficient, order 0
Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 154: Wavelength effective temperature [�C], 999=no effective temperature given
Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 158: Number of bright count cycles
Column 159: Number of dark count cycles
Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 163: Integration time [ms]
Column 164: Temperature at electronics board [�C], 999=no temperature signal
Column 165: Spectrometer control temperature [�C], 999=no temperature signal
Column 166: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Columns 167-432: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 433-698: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------