File name: Pandora26s1_CambridgeMA_20240920_L2Fit_fnvs4c7d20230915p1-8.txt
File generation date: 20240923T193647.9Z
Data description: Level 2 spectral fitting results file
Data file version: fnvs4c7p1-8
Local principal investigator: 
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 26
Spectrometer number: 1
Processing software version used: BlickP v1.8.59
Instrument operation file used: Pandora26_OF_v2d20230725.txt
Instrument calibration file used: Pandora26s1_CF_v7d20230915.txt
Level 1 file used: Pandora26s1_CambridgeMA_20240920_L1_smca1c7d20230915p1-8.txt
Full location name: Harvard - William James Hall, Cambridge (MA)
Short location name: CambridgeMA
Country of location: USA
Location latitude [deg]: 42.3800
Location longitude [deg]: -71.1100
Location altitude [m]: 60
Local noon date: 20240920
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method)
Data caveats: OOB session based on clearance session 5
First and last pixel inside fitting window: 892 1438
Nominal wavelengths inside fitting window [nm]: 400.1228 400.2547 400.3866 400.5185 400.6503 400.7822 400.9140 401.0458 401.1776 401.3093 401.4411 401.5729 401.7046 401.8363 401.9680 402.0997 402.2314 402.3631 402.4947 402.6263 402.7580 402.8896 403.0212 403.1527 403.2843 403.4159 403.5474 403.6789 403.8104 403.9419 404.0734 404.2049 404.3363 404.4677 404.5992 404.7306 404.8620 404.9934 405.1247 405.2561 405.3874 405.5187 405.6500 405.7813 405.9126 406.0439 406.1751 406.3064 406.4376 406.5688 406.7000 406.8312 406.9623 407.0935 407.2246 407.3557 407.4869 407.6180 407.7490 407.8801 408.0111 408.1422 408.2732 408.4042 408.5352 408.6662 408.7972 408.9281 409.0590 409.1900 409.3209 409.4518 409.5826 409.7135 409.8444 409.9752 410.1060 410.2368 410.3676 410.4984 410.6292 410.7599 410.8906 411.0214 411.1521 411.2828 411.4134 411.5441 411.6748 411.8054 411.9360 412.0666 412.1972 412.3278 412.4584 412.5889 412.7194 412.8500 412.9805 413.1109 413.2414 413.3719 413.5023 413.6328 413.7632 413.8936 414.0240 414.1544 414.2847 414.4151 414.5454 414.6757 414.8060 414.9363 415.0666 415.1968 415.3271 415.4573 415.5875 415.7177 415.8479 415.9781 416.1082 416.2384 416.3685 416.4986 416.6287 416.7588 416.8889 417.0189 417.1490 417.2790 417.4090 417.5390 417.6690 417.7990 417.9289 418.0589 418.1888 418.3187 418.4486 418.5785 418.7083 418.8382 418.9680 419.0979 419.2277 419.3575 419.4872 419.6170 419.7468 419.8765 420.0062 420.1359 420.2656 420.3953 420.5249 420.6546 420.7842 420.9138 421.0434 421.1730 421.3026 421.4322 421.5617 421.6912 421.8208 421.9503 422.0797 422.2092 422.3387 422.4681 422.5975 422.7270 422.8564 422.9857 423.1151 423.2445 423.3738 423.5031 423.6324 423.7617 423.8910 424.0203 424.1495 424.2788 424.4080 424.5372 424.6664 424.7956 424.9247 425.0539 425.1830 425.3121 425.4412 425.5703 425.6994 425.8285 425.9575 426.0865 426.2156 426.3446 426.4735 426.6025 426.7315 426.8604 426.9893 427.1182 427.2471 427.3760 427.5049 427.6337 427.7626 427.8914 428.0202 428.1490 428.2778 428.4065 428.5353 428.6640 428.7927 428.9214 429.0501 429.1788 429.3075 429.4361 429.5647 429.6934 429.8220 429.9505 430.0791 430.2077 430.3362 430.4647 430.5932 430.7217 430.8502 430.9787 431.1071 431.2356 431.3640 431.4924 431.6208 431.7492 431.8775 432.0059 432.1342 432.2625 432.3908 432.5191 432.6474 432.7756 432.9039 433.0321 433.1603 433.2885 433.4167 433.5449 433.6730 433.8011 433.9293 434.0574 434.1855 434.3135 434.4416 434.5696 434.6977 434.8257 434.9537 435.0817 435.2096 435.3376 435.4655 435.5935 435.7214 435.8493 435.9772 436.1050 436.2329 436.3607 436.4885 436.6163 436.7441 436.8719 436.9997 437.1274 437.2551 437.3828 437.5105 437.6382 437.7659 437.8936 438.0212 438.1488 438.2764 438.4040 438.5316 438.6592 438.7867 438.9142 439.0418 439.1693 439.2967 439.4242 439.5517 439.6791 439.8065 439.9339 440.0613 440.1887 440.3161 440.4434 440.5708 440.6981 440.8254 440.9527 441.0800 441.2072 441.3345 441.4617 441.5889 441.7161 441.8433 441.9705 442.0976 442.2247 442.3519 442.4790 442.6061 442.7331 442.8602 442.9872 443.1143 443.2413 443.3683 443.4953 443.6222 443.7492 443.8761 444.0030 444.1300 444.2568 444.3837 444.5106 444.6374 444.7643 444.8911 445.0179 445.1447 445.2714 445.3982 445.5249 445.6516 445.7783 445.9050 446.0317 446.1584 446.2850 446.4116 446.5383 446.6649 446.7914 446.9180 447.0446 447.1711 447.2976 447.4241 447.5506 447.6771 447.8036 447.9300 448.0564 448.1828 448.3092 448.4356 448.5620 448.6883 448.8147 448.9410 449.0673 449.1936 449.3199 449.4461 449.5724 449.6986 449.8248 449.9510 450.0772 450.2034 450.3295 450.4556 450.5818 450.7079 450.8339 450.9600 451.0861 451.2121 451.3381 451.4642 451.5901 451.7161 451.8421 451.9680 452.0940 452.2199 452.3458 452.4717 452.5975 452.7234 452.8492 452.9751 453.1009 453.2266 453.3524 453.4782 453.6039 453.7297 453.8554 453.9811 454.1067 454.2324 454.3581 454.4837 454.6093 454.7349 454.8605 454.9861 455.1116 455.2372 455.3627 455.4882 455.6137 455.7392 455.8646 455.9901 456.1155 456.2409 456.3663 456.4917 456.6171 456.7424 456.8678 456.9931 457.1184 457.2437 457.3690 457.4942 457.6195 457.7447 457.8699 457.9951 458.1203 458.2454 458.3706 458.4957 458.6208 458.7459 458.8710 458.9961 459.1211 459.2461 459.3712 459.4962 459.6212 459.7461 459.8711 459.9960 460.1209 460.2459 460.3708 460.4956 460.6205 460.7453 460.8702 460.9950 461.1198 461.2446 461.3693 461.4941 461.6188 461.7435 461.8682 461.9929 462.1176 462.2422 462.3669 462.4915 462.6161 462.7407 462.8653 462.9898 463.1144 463.2389 463.3634 463.4879 463.6124 463.7368 463.8613 463.9857 464.1101 464.2345 464.3589 464.4833 464.6076 464.7320 464.8563 464.9806 465.1049 465.2291 465.3534 465.4776 465.6019 465.7261 465.8503 465.9744 466.0986 466.2227 466.3469 466.4710 466.5951 466.7191 466.8432 466.9672 467.0913 467.2153 467.3393 467.4633 467.5872 467.7112 467.8351 467.9590 468.0829 468.2068 468.3307 468.4545 468.5784 468.7022 468.8260 468.9498 469.0736 469.1973 469.3210 469.4448 469.5685 469.6922 469.8158 469.9395
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Water vapor effective temperature [K]
Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Molecular iodine effective temperature [K]
Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Nitrogen dioxide effective temperature [K]
Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful
Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 60: Oxygen dimer effective temperature [K]
Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful
Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 71: Ozone effective temperature [K]
Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 82: Iodine dioxide effective temperature [K]
Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful
Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 90: Lower limit used for wavelength scaling [nm]
Column 91: Upper limit used for wavelength scaling [nm]
Column 92: Order of smoothing polynomial
Column 93: Smoothing polynomial coefficient, order 0
Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 98: Smoothing polynomial coefficient, order 1
Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 103: Smoothing polynomial coefficient, order 2
Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 108: Smoothing polynomial coefficient, order 3
Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 113: Smoothing polynomial coefficient, order 4
Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 118: Mean value of measured data inside fitting window [same units as measurements]
Column 119: Offset polynomial coefficient, order 0
Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 124: Wavelength change polynomial coefficient, order 0
Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 129: Wavelength change polynomial coefficient, order 1
Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 136: Resolution change polynomial coefficient, order 0
Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 148: Wavelength effective temperature [�C], 999=no effective temperature given
Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 152: Number of bright count cycles
Column 153: Number of dark count cycles
Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 157: Integration time [ms]
Column 158: Temperature at electronics board [�C], 999=no temperature signal
Column 159: Spectrometer control temperature [�C], 999=no temperature signal
Column 160: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Column 161: Temperature in head sensor [�C], 999=no temperature signal
Column 162: Humidity in head sensor [%], -9=no humidity signal
Column 163: Pressure in head sensor [hPa], -9=no pressure signal
Columns 164-710: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 711-1257: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------