File name: Pandora225s1_Cebu_20241208_L2Fit_fwvt1c2d20220603p1-8.txt File generation date: 20241209T091241.4Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c2p1-8 Local principal investigator: Ellison Castro Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 225 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora225_OF_v2d20220531.txt Instrument calibration file used: Pandora225s1_CF_v2d20220603.txt Level 1 file used: Pandora225s1_Cebu_20241208_L1_smca1c2d20220603p1-8.txt Full location name: University of San Carlos - Talamban Campus Short location name: Cebu Country of location: Philippines Location latitude [deg]: 10.3551 Location longitude [deg]: 123.9111 Location altitude [m]: 67 Local noon date: 20241208 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method) Data caveats: OoB based on session 1 for initial instrument deployment First and last pixel inside fitting window: 1613 1762 Nominal wavelengths inside fitting window [nm]: 492.0330 492.1544 492.2759 492.3973 492.5187 492.6401 492.7615 492.8828 493.0042 493.1255 493.2468 493.3681 493.4894 493.6106 493.7319 493.8531 493.9743 494.0955 494.2167 494.3378 494.4590 494.5801 494.7012 494.8223 494.9434 495.0644 495.1855 495.3065 495.4275 495.5485 495.6695 495.7904 495.9114 496.0323 496.1532 496.2741 496.3950 496.5158 496.6366 496.7575 496.8783 496.9991 497.1198 497.2406 497.3613 497.4820 497.6027 497.7234 497.8441 497.9647 498.0854 498.2060 498.3266 498.4472 498.5677 498.6883 498.8088 498.9293 499.0498 499.1703 499.2908 499.4112 499.5317 499.6521 499.7725 499.8928 500.0132 500.1335 500.2539 500.3742 500.4945 500.6148 500.7350 500.8553 500.9755 501.0957 501.2159 501.3361 501.4562 501.5763 501.6965 501.8166 501.9367 502.0567 502.1768 502.2968 502.4168 502.5368 502.6568 502.7768 502.8968 503.0167 503.1366 503.2565 503.3764 503.4963 503.6161 503.7359 503.8558 503.9756 504.0953 504.2151 504.3348 504.4546 504.5743 504.6940 504.8137 504.9333 505.0530 505.1726 505.2922 505.4118 505.5314 505.6509 505.7705 505.8900 506.0095 506.1290 506.2484 506.3679 506.4873 506.6068 506.7262 506.8455 506.9649 507.0843 507.2036 507.3229 507.4422 507.5615 507.6808 507.8000 507.9192 508.0385 508.1576 508.2768 508.3960 508.5151 508.6343 508.7534 508.8725 508.9915 509.1106 509.2296 509.3487 509.4677 509.5867 509.7056 509.8246 509.9435 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 251-400: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20241208T071756.8Z 9108.304130 388 1 15.00 2 63.54 237.96 38.93 118.45 0.00 1 0.00 1 0 22 3.290e-03 3.265e-03 3.479e-04 3.472e-04 6.659727e+03 2.245933e+01 4.487380e+02 -6.000000e+00 1.824377e+02 294.00 -2.00 20.00 -2.00 505.28 0.00e+00 4.768330e-04 9.676559e-06 3.789458e-05 -6.000000e+00 9.347866e-05 294.00 -2.00 20.00 -2.00 500.45 0.00e+00 1.257702e-01 6.650614e-03 3.890581e-02 -6.000000e+00 6.307574e-02 225.77 -2.00 3.06 -2.00 502.04 0.00e+00 2.231 0.000 489.00 513.00 1 4.1332e+00 5.1116e-04 4.6656e-03 -6.0000e+00 4.8506e-03 7.5220e-03 1.3185e-04 9.6193e-04 -6.0000e+00 1.2637e-03 2.2344e-02 1.0110e-03 2.8462e-05 4.3824e-05 -6.0000e+00 2.8152e-04 9.7307e-03 1.9743e-04 12 1 1 12 1 1 73.27 26.56 0.62 0.00973 0.01674 72 40 1 4 0 205.440 29.16 20.00 26.56 35.18 1.5 1031.38 -816 -618 -229 4 326 466 525 552 300 315 181 -131 -386 -436 -438 -294 -69 100 79 186 145 149 251 232 225 436 414 -104 -383 -467 -499 -418 54 44 232 302 235 -57 -193 -40 -42 161 136 290 329 453 360 307 12 -308 -654 -860 -638 -550 -178 -66 156 149 215 232 276 319 361 253 202 159 31 -141 -362 -365 -408 -215 28 -44 -95 -27 -91 -270 -453 -390 -331 -285 -236 -234 -68 -15 -97 -210 -168 -126 104 257 357 475 345 231 103 -326 -638 -721 -607 -289 -113 -20 128 82 -228 -299 -201 -299 -74 162 225 359 509 551 537 364 358 228 40 170 209 44 268 116 172 262 329 41 35 -15 -321 -343 -363 -309 -37 175 101 158 254 282 339 405 327 -24 -298 -547 -600 -703 -799 -601 -230 4 339 483 555 588 318 329 186 -134 -397 -442 -443 -298 -71 103 82 195 152 156 262 243 238 459 434 -108 -394 -473 -501 -423 54 45 246 320 245 -59 -197 -41 -43 164 141 303 346 476 375 315 12 -309 -651 -838 -617 -540 -176 -67 159 153 218 235 280 326 370 258 204 161 31 -140 -355 -360 -401 -208 27 -43 -95 -26 -90 -262 -437 -375 -321 -279 -227 -228 -67 -15 -96 -208 -166 -125 101 255 358 469 341 223 99 -305 -599 -670 -569 -272 -108 -20 128 81 -224 -295 -198 -292 -73 162 227 355 505 550 542 368 356 227 40 164 202 43 262 114 169 255 320 40 33 -15 -305 -323 -345 -295 -36 173 99 156 252 281 340 406 327 -23 -292 -526 -572 -677 SQ 20241208T072253.0Z 9108.307558 391 1 51.82 2 64.57 238.49 37.88 119.36 0.00 1 0.00 1 0 15 3.254e-03 3.225e-03 1.477e-04 1.473e-04 6.930831e+03 9.606774e+00 4.667370e+02 -6.000000e+00 1.804434e+02 294.00 -2.00 20.00 -2.00 505.28 0.00e+00 4.916144e-04 4.103033e-06 3.824704e-05 -6.000000e+00 9.246378e-05 294.00 -2.00 20.00 -2.00 500.42 0.00e+00 1.424631e-01 2.826875e-03 3.992093e-02 -6.000000e+00 6.239739e-02 225.77 -2.00 3.06 -2.00 502.02 0.00e+00 2.314 0.000 489.00 513.00 1 3.5554e+00 2.1722e-04 4.8103e-03 -6.0000e+00 4.7983e-03 6.7001e-03 5.6027e-05 9.9208e-04 -6.0000e+00 1.2503e-03 3.9280e-02 1.2380e-03 1.2058e-05 4.5193e-05 -6.0000e+00 2.7849e-04 1.0025e-02 1.8644e-04 10 0 0 10 0 0 92.02 26.58 0.63 0.01003 0.01861 507 80 1 4 0 102.200 29.16 20.00 26.58 35.52 1.5 1033.23 -824 -588 -239 33 320 425 494 534 345 263 153 -109 -384 -448 -423 -265 -70 141 104 198 182 87 242 257 261 396 440 -72 -372 -507 -548 -395 14 99 203 309 182 -56 -190 -108 -66 118 178 317 386 381 384 290 -20 -294 -591 -821 -687 -478 -250 -52 179 144 174 198 251 303 329 308 217 159 55 -132 -353 -314 -338 -260 -7 -11 -58 -39 -70 -272 -501 -434 -348 -312 -225 -238 -61 -50 -80 -159 -105 -98 105 327 316 478 353 257 94 -345 -632 -733 -567 -331 -120 -77 109 60 -180 -249 -260 -275 -72 118 237 358 519 558 491 363 328 156 76 152 141 73 210 171 123 320 271 63 55 -31 -380 -330 -337 -272 -34 148 129 141 262 271 359 435 320 -42 -333 -544 -659 -652 -800 -580 -236 34 335 438 519 566 364 273 157 -111 -396 -456 -429 -270 -73 145 109 211 194 92 257 275 280 424 469 -77 -380 -517 -553 -401 14 104 212 322 194 -59 -197 -111 -68 123 187 326 400 394 394 303 -20 -294 -591 -804 -667 -472 -246 -53 185 150 180 204 259 305 333 310 223 161 55 -130 -344 -301 -324 -251 -7 -11 -58 -38 -67 -266 -486 -420 -339 -297 -216 -231 -60 -49 -79 -156 -103 -97 104 330 312 481 347 246 91 -324 -582 -669 -521 -313 -115 -75 107 59 -179 -244 -254 -273 -71 116 235 356 518 561 499 369 329 153 74 149 139 70 202 165 119 307 260 60 53 -29 -359 -310 -319 -265 -33 144 127 141 262 273 362 440 322 -41 -323 -516 -620 -619 SQ 20241208T072639.9Z 9108.310184 393 1 51.81 2 65.37 238.89 37.08 120.10 0.00 1 0.00 1 0 15 3.250e-03 3.217e-03 1.499e-04 1.496e-04 7.165197e+03 9.835359e+00 4.807474e+02 -6.000000e+00 1.801884e+02 294.00 -2.00 20.00 -2.00 505.29 0.00e+00 4.918953e-04 4.159400e-06 3.930845e-05 -6.000000e+00 9.232817e-05 294.00 -2.00 20.00 -2.00 500.43 0.00e+00 1.519629e-01 2.871183e-03 4.133101e-02 -6.000000e+00 6.230125e-02 225.77 -2.00 3.06 -2.00 502.03 0.00e+00 2.382 0.000 489.00 513.00 1 3.5710e+00 2.2050e-04 4.9644e-03 -6.0000e+00 4.7910e-03 6.7545e-03 5.6832e-05 1.0246e-03 -6.0000e+00 1.2482e-03 3.8257e-02 1.1073e-03 1.2237e-05 4.5682e-05 -6.0000e+00 2.7807e-04 9.2435e-03 1.9778e-04 10 0 0 10 0 0 87.87 26.58 0.63 0.00924 0.01692 509 81 1 4 0 101.770 29.16 20.00 26.58 35.65 1.5 1034.63 -833 -616 -239 52 311 423 501 525 367 280 135 -148 -368 -458 -416 -293 -58 107 70 176 202 125 260 275 262 388 410 -53 -384 -493 -532 -417 49 72 193 308 169 -78 -183 -62 -79 140 192 315 379 392 393 289 -41 -315 -593 -829 -667 -495 -255 -32 158 151 153 203 258 309 322 300 203 133 64 -146 -369 -337 -324 -285 -9 -14 -63 -55 -96 -259 -462 -383 -343 -271 -210 -227 -66 -35 -127 -181 -133 -83 113 305 332 434 347 275 76 -372 -650 -743 -560 -329 -80 -75 104 86 -183 -263 -262 -266 -72 111 181 340 505 582 474 416 336 190 67 129 166 66 221 179 137 322 268 83 88 -39 -372 -322 -328 -285 -63 136 155 149 238 267 332 439 329 -53 -298 -530 -632 -670 -803 -603 -242 53 323 447 522 552 384 289 142 -154 -377 -462 -419 -297 -60 109 73 186 214 132 275 291 279 412 434 -55 -390 -498 -533 -421 50 75 207 328 178 -81 -188 -64 -80 144 200 332 403 417 414 300 -42 -312 -589 -806 -643 -485 -258 -32 163 156 158 208 265 319 333 310 207 134 64 -143 -357 -331 -317 -282 -8 -14 -62 -54 -95 -251 -445 -367 -332 -265 -206 -218 -64 -35 -125 -177 -130 -82 111 306 336 433 337 261 72 -346 -592 -671 -510 -308 -76 -75 105 86 -181 -256 -254 -262 -72 108 178 336 499 579 478 420 334 186 66 125 161 65 218 176 135 316 263 81 85 -37 -349 -300 -309 -276 -61 131 152 147 236 267 332 440 329 -52 -287 -515 -610 -652 SQ 20241208T073158.0Z 9108.313866 396 1 51.70 2 66.48 239.43 35.97 121.18 0.00 1 0.00 1 0 22 3.282e-03 3.247e-03 2.192e-04 2.186e-04 7.447593e+03 1.444801e+01 4.983732e+02 -6.000000e+00 1.819962e+02 294.00 -2.00 20.00 -2.00 505.29 0.00e+00 5.003680e-04 6.081442e-06 4.029096e-05 -6.000000e+00 9.325369e-05 294.00 -2.00 20.00 -2.00 500.43 0.00e+00 1.639660e-01 4.199703e-03 4.294474e-02 -6.000000e+00 6.292505e-02 225.77 -2.00 3.06 -2.00 502.02 0.00e+00 2.487 0.000 489.00 513.00 1 4.2935e+00 3.2255e-04 5.1662e-03 -6.0000e+00 4.8390e-03 7.1474e-03 8.3099e-05 1.0646e-03 -6.0000e+00 1.2607e-03 1.8276e-02 1.0654e-03 1.7854e-05 4.6679e-05 -6.0000e+00 2.8085e-04 9.4188e-03 1.9773e-04 10 0 0 10 0 0 78.91 26.58 0.63 0.00942 0.01681 249 40 1 4 0 207.590 29.16 20.00 26.58 35.89 1.5 1035.68 -812 -627 -224 11 336 431 501 525 374 254 138 -117 -380 -443 -420 -303 -68 147 71 189 188 88 263 254 241 387 428 -74 -385 -480 -555 -376 53 112 215 273 185 -67 -183 -102 -23 102 212 318 376 392 401 288 -34 -319 -632 -851 -666 -501 -216 -64 166 156 184 145 246 302 349 318 252 132 60 -136 -368 -309 -346 -272 -25 -15 -59 -46 -107 -261 -438 -441 -356 -334 -239 -247 -54 -20 -127 -168 -106 -94 98 293 367 427 362 250 88 -338 -652 -753 -604 -343 -77 -83 103 103 -203 -253 -259 -250 -77 109 214 325 534 559 448 376 363 199 83 140 151 89 241 179 131 348 336 67 105 -82 -369 -308 -278 -273 -103 145 82 159 251 292 353 441 295 -12 -281 -557 -690 -663 -783 -616 -227 11 349 455 522 551 392 262 145 -122 -390 -447 -423 -307 -70 155 74 199 198 93 277 269 257 411 452 -77 -390 -485 -557 -379 55 116 230 291 194 -69 -189 -104 -24 105 221 335 399 416 421 298 -35 -316 -628 -829 -643 -491 -219 -64 171 161 189 148 252 312 361 328 257 132 59 -133 -368 -303 -339 -270 -24 -15 -59 -45 -105 -253 -422 -424 -345 -326 -234 -237 -53 -20 -125 -164 -103 -92 97 293 370 424 351 237 84 -314 -593 -679 -549 -320 -73 -83 104 103 -201 -245 -251 -246 -77 110 210 320 527 556 451 379 361 194 82 136 147 87 238 177 130 341 329 65 101 -77 -346 -287 -261 -264 -101 140 80 157 248 291 354 442 294 -12 -270 -541 -666 -645 SQ 20241208T073641.0Z 9108.317142 399 1 52.10 2 67.49 239.89 34.99 122.20 0.00 1 0.00 1 0 15 3.331e-03 3.297e-03 4.446e-04 4.434e-04 7.765572e+03 2.935203e+01 5.180053e+02 -6.000000e+00 1.847036e+02 294.00 -2.00 20.00 -2.00 505.28 0.00e+00 4.970635e-04 1.238195e-05 4.139440e-05 -6.000000e+00 9.463973e-05 294.00 -2.00 20.00 -2.00 500.42 0.00e+00 1.849744e-01 8.524479e-03 4.478385e-02 -6.000000e+00 6.385889e-02 225.77 -2.00 3.06 -2.00 502.02 0.00e+00 2.590 0.000 489.00 513.00 1 5.6281e+00 6.5578e-04 5.3813e-03 -6.0000e+00 4.9108e-03 7.8005e-03 1.6864e-04 1.1078e-03 -6.0000e+00 1.2794e-03 4.7325e-03 1.1221e-03 3.6020e-05 4.9546e-05 -6.0000e+00 2.8502e-04 8.5906e-03 2.0474e-04 10 0 0 10 0 0 91.22 26.59 0.60 0.00859 0.01637 69 11 1 4 0 754.940 29.16 20.00 26.59 35.99 1.5 1036.49 -821 -724 -227 71 279 502 493 540 344 324 149 -217 -392 -437 -478 -326 -65 227 118 122 190 146 297 237 249 413 361 0 -351 -519 -555 -422 30 84 169 323 217 -50 -184 -140 0 136 214 292 362 431 399 290 96 -337 -671 -884 -714 -583 -214 -29 200 126 167 246 271 281 324 273 224 216 30 -207 -356 -377 -336 -263 -18 -79 -110 -47 -74 -186 -433 -368 -424 -253 -196 -250 0 11 -107 -235 -74 -89 168 331 298 463 310 230 68 -298 -697 -683 -624 -313 -60 -61 29 29 -109 -262 -287 -308 -120 34 135 285 455 597 548 421 395 124 110 121 119 106 286 205 152 315 349 47 47 -25 -348 -302 -302 -274 -79 151 175 132 178 298 326 450 252 -42 -287 -542 -641 -631 -791 -710 -230 71 288 528 528 583 370 343 156 -225 -399 -439 -479 -329 -66 238 128 128 199 153 310 248 263 434 378 0 -366 -522 -553 -423 31 87 179 341 226 -52 -195 -147 0 139 221 304 381 453 415 298 96 -343 -663 -856 -685 -569 -215 -30 203 128 170 249 275 287 332 279 226 215 31 -208 -353 -368 -328 -259 -17 -80 -111 -47 -73 -179 -414 -350 -408 -246 -191 -247 0 11 -103 -236 -74 -86 163 327 298 455 309 223 64 -274 -629 -634 -563 -290 -58 -59 29 29 -106 -252 -275 -300 -119 34 136 287 458 606 562 433 401 124 108 116 115 103 278 200 148 305 337 46 45 -23 -323 -288 -281 -261 -77 149 175 133 174 293 322 443 248 -42 -282 -520 -612 -607 SQ 20241208T074106.5Z 9108.320214 402 1 51.63 2 68.43 240.30 34.08 123.21 0.00 1 0.00 1 0 15 3.703e-03 3.687e-03 9.277e-04 9.247e-04 8.229426e+03 6.192683e+01 5.529487e+02 -6.000000e+00 2.053268e+02 294.00 -2.00 20.00 -2.00 505.29 0.00e+00 5.587810e-04 2.574835e-05 4.459825e-05 -6.000000e+00 1.052203e-04 294.00 -2.00 20.00 -2.00 500.38 0.00e+00 2.160812e-01 1.783547e-02 4.633045e-02 -6.000000e+00 7.101079e-02 225.77 -2.00 3.06 -2.00 501.99 0.00e+00 2.695 0.000 489.00 513.00 1 6.8925e+00 1.3682e-03 5.5957e-03 -6.0000e+00 5.4605e-03 9.9031e-03 3.5315e-04 1.1588e-03 -6.0000e+00 1.4230e-03 1.3116e-03 1.3521e-03 7.5315e-05 5.1731e-05 -6.0000e+00 3.1693e-04 1.1398e-02 1.7183e-04 10 0 0 10 0 0 80.64 26.59 0.67 0.01140 0.02078 21 3 1 4 0 2458.290 29.16 20.00 26.59 36.15 1.4 1037.60 -963 -661 -248 228 351 436 435 586 487 48 15 -13 -587 -471 -208 -290 -26 107 -10 254 235 284 174 450 290 221 498 -255 -385 -608 -695 -519 -24 213 175 466 193 3 -420 74 -152 199 156 356 529 395 745 238 121 -419 -606 -953 -855 -581 -300 -15 173 121 294 259 413 233 280 202 320 23 -72 -193 -216 -381 -483 -380 51 271 -330 -57 -149 9 -426 -370 -294 -376 -215 -470 -90 -6 -95 -193 -102 16 186 345 160 456 390 335 204 -333 -660 -765 -671 -387 -132 -211 42 6 -112 -223 -289 -213 -67 -15 143 591 605 804 396 515 474 48 40 -21 271 6 243 220 179 303 146 28 -77 108 -577 -309 -238 -416 -51 42 233 32 414 283 371 291 326 158 -375 -443 -465 -807 -914 -637 -248 235 371 469 456 618 512 50 16 -14 -613 -484 -213 -299 -27 110 -11 269 249 301 184 478 310 237 528 -269 -392 -626 -709 -534 -24 222 188 497 204 3 -435 75 -157 205 163 376 563 420 783 247 124 -418 -612 -944 -840 -579 -295 -15 178 126 303 266 424 241 290 210 327 23 -71 -189 -209 -364 -460 -365 49 266 -327 -56 -142 8 -416 -360 -276 -356 -204 -453 -88 -6 -93 -188 -99 16 183 345 162 452 377 315 186 -312 -605 -694 -615 -364 -125 -209 42 6 -110 -216 -279 -209 -66 -15 145 599 613 821 393 511 464 48 39 -20 263 5 238 216 176 295 143 27 -74 101 -540 -287 -223 -401 -50 40 224 31 404 278 366 288 321 153 -356 -429 -447 -785