File name: Pandora31s1_CharlesCityVA_20241122_L2Fit_ffuh5c7d20240321p1-8.txt File generation date: 20241205T053711.4Z Data description: Level 2 spectral fitting results file Data file version: ffuh5c7p1-8 Local principal investigator: Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 31 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora31_OF_v1d20240301.txt Instrument calibration file used: Pandora31s1_CF_v7d20240321.txt Level 1 file used: Pandora31s1_CharlesCityVA_20241122_L1_smca1c7d20240321p1-8.txt Full location name: Richmond VCU Short location name: CharlesCityVA Country of location: USA Location latitude [deg]: 37.3260 Location longitude [deg]: -77.2057 Location altitude [m]: 6 Local noon date: 20241122 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 421 643 Nominal wavelengths inside fitting window [nm]: 328.5260 328.6646 328.8031 328.9417 329.0802 329.2188 329.3573 329.4958 329.6343 329.7728 329.9112 330.0497 330.1882 330.3266 330.4650 330.6034 330.7418 330.8802 331.0186 331.1570 331.2953 331.4337 331.5720 331.7103 331.8486 331.9869 332.1252 332.2635 332.4018 332.5400 332.6783 332.8165 332.9547 333.0929 333.2311 333.3693 333.5074 333.6456 333.7838 333.9219 334.0600 334.1981 334.3362 334.4743 334.6124 334.7504 334.8885 335.0265 335.1646 335.3026 335.4406 335.5786 335.7166 335.8545 335.9925 336.1304 336.2684 336.4063 336.5442 336.6821 336.8200 336.9579 337.0957 337.2336 337.3714 337.5093 337.6471 337.7849 337.9227 338.0605 338.1982 338.3360 338.4737 338.6115 338.7492 338.8869 339.0246 339.1623 339.3000 339.4376 339.5753 339.7129 339.8506 339.9882 340.1258 340.2634 340.4009 340.5385 340.6761 340.8136 340.9511 341.0887 341.2262 341.3637 341.5012 341.6386 341.7761 341.9135 342.0510 342.1884 342.3258 342.4632 342.6006 342.7380 342.8753 343.0127 343.1500 343.2874 343.4247 343.5620 343.6993 343.8365 343.9738 344.1111 344.2483 344.3855 344.5228 344.6600 344.7972 344.9343 345.0715 345.2087 345.3458 345.4829 345.6201 345.7572 345.8943 346.0314 346.1684 346.3055 346.4425 346.5796 346.7166 346.8536 346.9906 347.1276 347.2646 347.4015 347.5385 347.6754 347.8123 347.9492 348.0861 348.2230 348.3599 348.4968 348.6336 348.7705 348.9073 349.0441 349.1809 349.3177 349.4545 349.5912 349.7280 349.8647 350.0014 350.1381 350.2748 350.4115 350.5482 350.6849 350.8215 350.9582 351.0948 351.2314 351.3680 351.5046 351.6411 351.7777 351.9143 352.0508 352.1873 352.3238 352.4603 352.5968 352.7333 352.8697 353.0062 353.1426 353.2791 353.4155 353.5519 353.6882 353.8246 353.9610 354.0973 354.2337 354.3700 354.5063 354.6426 354.7789 354.9151 355.0514 355.1876 355.3239 355.4601 355.5963 355.7325 355.8687 356.0048 356.1410 356.2771 356.4132 356.5494 356.6855 356.8216 356.9576 357.0937 357.2297 357.3658 357.5018 357.6378 357.7738 357.9098 358.0458 358.1817 358.3177 358.4536 358.5895 358.7254 358.8613 358.9972 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Formaldehyde effective temperature [K] Column 28: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 45: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Oxygen dimer effective temperature [K] Column 50: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Ozone effective temperature [K] Column 61: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Fitted Ring spectrum, -9e99=no fitting done or fitting not successful Column 67: Independent uncertainty of fitted Ring spectrum, -9=fitting not successful Column 68: Structured uncertainty of fitted Ring spectrum, -9=fitting not successful Column 69: Common uncertainty of fitted Ring spectrum, -9=fitting not successful Column 70: rms-based uncertainty of fitted Ring spectrum, -9=fitting not successful Column 71: Effective Ring fitting wavelength [nm], -9=fitting not done or not successful Column 72: Diffuse correction applied before fitting at effective Ring fitting wavelength [%], 0=no diffuse correction applied, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 73: Lower limit used for wavelength scaling [nm] Column 74: Upper limit used for wavelength scaling [nm] Column 75: Order of smoothing polynomial Column 76: Smoothing polynomial coefficient, order 0 Column 77: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 78: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 79: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 80: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 81: Smoothing polynomial coefficient, order 1 Column 82: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 83: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 84: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 85: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 86: Smoothing polynomial coefficient, order 2 Column 87: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 88: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 89: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 90: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 91: Smoothing polynomial coefficient, order 3 Column 92: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 93: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 94: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 95: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 96: Smoothing polynomial coefficient, order 4 Column 97: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 98: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 99: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 100: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 101: Mean value of measured data inside fitting window [same units as measurements] Column 102: Offset polynomial coefficient, order 0 Column 103: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 104: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 105: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 106: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 107: Offset polynomial coefficient, order 1 Column 108: Independent uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 109: Structured uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 110: Common uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 111: rms-based uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 112: Wavelength change polynomial coefficient, order 0 Column 113: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 114: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 115: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 116: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 117: Wavelength change polynomial coefficient, order 1 Column 118: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 119: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 120: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 121: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 122: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 123: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 124: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 125: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 126: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 127: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 128: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 129: Atmospheric variability [%], 999=no atmospheric variability was determined Column 130: Wavelength effective temperature [°C], 999=no effective temperature given Column 131: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 132: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 133: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 134: Number of bright count cycles Column 135: Number of dark count cycles Column 136: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 137: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 138: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 139: Integration time [ms] Column 140: Temperature at electronics board [°C], 999=no temperature signal Column 141: Spectrometer control temperature [°C], 999=no temperature signal Column 142: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 143: Temperature in head sensor [°C], 999=no temperature signal Column 144: Humidity in head sensor [%], -9=no humidity signal Column 145: Pressure in head sensor [hPa], -9=no pressure signal Columns 146-368: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 369-591: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------