File name: Pandora40s1_CharlesCityVA_20181124_L2Fit_fwvt1c12d20180910p1-8.txt
File generation date: 20250129T152644.5Z
Data description: Level 2 spectral fitting results file
Data file version: fwvt1c12p1-8
Local principal investigator: Nader Abuhassan
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 40
Spectrometer number: 1
Processing software version used: BlickP v1.8.70
Instrument operation file used: Pandora40_OF_v2d20170420.txt
Instrument calibration file used: Pandora40s1_CF_v12d20180910.txt
Level 1 file used: Pandora40s1_CharlesCityVA_20181124_L1_smca1c12d20180910p1-8.txt
Full location name: Richmond VCU
Short location name: CharlesCityVA
Country of location: USA
Location latitude [deg]: 37.3260
Location longitude [deg]: -77.2057
Location altitude [m]: 6
Local noon date: 20181124
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method)
Data caveats: None
First and last pixel inside fitting window: 1681 1831
Nominal wavelengths inside fitting window [nm]: 492.0114 492.1322 492.2529 492.3736 492.4943 492.6150 492.7357 492.8563 492.9770 493.0976 493.2182 493.3387 493.4593 493.5798 493.7004 493.8209 493.9414 494.0618 494.1823 494.3027 494.4232 494.5436 494.6640 494.7843 494.9047 495.0250 495.1454 495.2657 495.3859 495.5062 495.6265 495.7467 495.8669 495.9871 496.1073 496.2275 496.3476 496.4677 496.5878 496.7079 496.8280 496.9481 497.0681 497.1881 497.3081 497.4281 497.5481 497.6681 497.7880 497.9079 498.0278 498.1477 498.2676 498.3874 498.5073 498.6271 498.7469 498.8667 498.9864 499.1062 499.2259 499.3456 499.4653 499.5850 499.7046 499.8243 499.9439 500.0635 500.1831 500.3027 500.4222 500.5418 500.6613 500.7808 500.9003 501.0197 501.1392 501.2586 501.3780 501.4974 501.6168 501.7362 501.8555 501.9749 502.0942 502.2135 502.3327 502.4520 502.5712 502.6905 502.8097 502.9288 503.0480 503.1672 503.2863 503.4054 503.5245 503.6436 503.7627 503.8817 504.0007 504.1197 504.2387 504.3577 504.4767 504.5956 504.7145 504.8334 504.9523 505.0712 505.1900 505.3089 505.4277 505.5465 505.6653 505.7840 505.9028 506.0215 506.1402 506.2589 506.3776 506.4962 506.6149 506.7335 506.8521 506.9707 507.0893 507.2078 507.3264 507.4449 507.5634 507.6818 507.8003 507.9188 508.0372 508.1556 508.2740 508.3924 508.5107 508.6290 508.7474 508.8657 508.9840 509.1022 509.2205 509.3387 509.4569 509.5751 509.6933 509.8114 509.9296
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Water vapor effective temperature [K]
Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Nitrogen dioxide effective temperature [K]
Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Ozone effective temperature [K]
Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 57: Lower limit used for wavelength scaling [nm]
Column 58: Upper limit used for wavelength scaling [nm]
Column 59: Order of smoothing polynomial
Column 60: Smoothing polynomial coefficient, order 0
Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 65: Smoothing polynomial coefficient, order 1
Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 70: Mean value of measured data inside fitting window [same units as measurements]
Column 71: Wavelength change polynomial coefficient, order 0
Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 85: Wavelength effective temperature [�C], 999=no effective temperature given
Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 89: Number of bright count cycles
Column 90: Number of dark count cycles
Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 94: Integration time [ms]
Column 95: Temperature at electronics board [�C], 999=no temperature signal
Column 96: Spectrometer control temperature [�C], 999=no temperature signal
Column 97: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Columns 98-248: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 249-399: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------