File name: Pandora153s1_ChelseaMA_20241223_L2Fit_fnvs4c7d20240424p1-8.txt
File generation date: 20241230T200702.6Z
Data description: Level 2 spectral fitting results file
Data file version: fnvs4c7p1-8
Local principal investigator: Jeff Geddes
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 153
Spectrometer number: 1
Processing software version used: BlickP v1.8.60
Instrument operation file used: Pandora153_OF_v3d20200209.txt
Instrument calibration file used: Pandora153s1_CF_v7d20240424.txt
Level 1 file used: Pandora153s1_ChelseaMA_20241223_L1_smca1c7d20240424p1-8.txt
Full location name: Chelsea, Massachusetts
Short location name: ChelseaMA
Country of location: United States
Location latitude [deg]: 42.3946
Location longitude [deg]: -71.0307
Location altitude [m]: 30
Local noon date: 20241223
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method)
Data caveats: AnaFld of OoB session 6.
First and last pixel inside fitting window: 925 1470
Nominal wavelengths inside fitting window [nm]: 400.0091 400.1414 400.2737 400.4060 400.5382 400.6705 400.8027 400.9349 401.0671 401.1993 401.3314 401.4636 401.5957 401.7279 401.8600 401.9921 402.1242 402.2562 402.3883 402.5203 402.6523 402.7844 402.9164 403.0483 403.1803 403.3123 403.4442 403.5761 403.7081 403.8400 403.9718 404.1037 404.2356 404.3674 404.4992 404.6311 404.7629 404.8946 405.0264 405.1582 405.2899 405.4216 405.5534 405.6851 405.8167 405.9484 406.0801 406.2117 406.3434 406.4750 406.6066 406.7382 406.8697 407.0013 407.1328 407.2644 407.3959 407.5274 407.6589 407.7903 407.9218 408.0532 408.1847 408.3161 408.4475 408.5789 408.7103 408.8416 408.9730 409.1043 409.2356 409.3669 409.4982 409.6295 409.7607 409.8920 410.0232 410.1544 410.2856 410.4168 410.5480 410.6791 410.8103 410.9414 411.0725 411.2036 411.3347 411.4658 411.5968 411.7279 411.8589 411.9899 412.1209 412.2519 412.3829 412.5139 412.6448 412.7757 412.9066 413.0375 413.1684 413.2993 413.4302 413.5610 413.6918 413.8226 413.9534 414.0842 414.2150 414.3458 414.4765 414.6072 414.7379 414.8686 414.9993 415.1300 415.2606 415.3913 415.5219 415.6525 415.7831 415.9137 416.0443 416.1748 416.3054 416.4359 416.5664 416.6969 416.8274 416.9578 417.0883 417.2187 417.3492 417.4796 417.6100 417.7403 417.8707 418.0011 418.1314 418.2617 418.3920 418.5223 418.6526 418.7829 418.9131 419.0433 419.1736 419.3038 419.4340 419.5641 419.6943 419.8244 419.9546 420.0847 420.2148 420.3449 420.4750 420.6050 420.7351 420.8651 420.9951 421.1251 421.2551 421.3851 421.5150 421.6450 421.7749 421.9048 422.0347 422.1646 422.2945 422.4243 422.5542 422.6840 422.8138 422.9436 423.0734 423.2032 423.3329 423.4627 423.5924 423.7221 423.8518 423.9815 424.1111 424.2408 424.3704 424.5001 424.6297 424.7593 424.8888 425.0184 425.1480 425.2775 425.4070 425.5365 425.6660 425.7955 425.9249 426.0544 426.1838 426.3132 426.4426 426.5720 426.7014 426.8308 426.9601 427.0894 427.2187 427.3480 427.4773 427.6066 427.7358 427.8651 427.9943 428.1235 428.2527 428.3819 428.5111 428.6402 428.7694 428.8985 429.0276 429.1567 429.2858 429.4148 429.5439 429.6729 429.8019 429.9309 430.0599 430.1889 430.3179 430.4468 430.5757 430.7046 430.8335 430.9624 431.0913 431.2202 431.3490 431.4778 431.6066 431.7354 431.8642 431.9930 432.1217 432.2505 432.3792 432.5079 432.6366 432.7653 432.8939 433.0226 433.1512 433.2798 433.4085 433.5370 433.6656 433.7942 433.9227 434.0513 434.1798 434.3083 434.4368 434.5652 434.6937 434.8221 434.9505 435.0790 435.2074 435.3357 435.4641 435.5925 435.7208 435.8491 435.9774 436.1057 436.2340 436.3623 436.4905 436.6187 436.7469 436.8752 437.0033 437.1315 437.2597 437.3878 437.5159 437.6441 437.7721 437.9002 438.0283 438.1564 438.2844 438.4124 438.5404 438.6684 438.7964 438.9244 439.0523 439.1802 439.3082 439.4361 439.5639 439.6918 439.8197 439.9475 440.0753 440.2032 440.3310 440.4587 440.5865 440.7143 440.8420 440.9697 441.0974 441.2251 441.3528 441.4805 441.6081 441.7357 441.8634 441.9910 442.1186 442.2461 442.3737 442.5012 442.6288 442.7563 442.8838 443.0112 443.1387 443.2662 443.3936 443.5210 443.6484 443.7758 443.9032 444.0306 444.1579 444.2852 444.4125 444.5399 444.6671 444.7944 444.9217 445.0489 445.1761 445.3033 445.4305 445.5577 445.6849 445.8120 445.9392 446.0663 446.1934 446.3205 446.4475 446.5746 446.7016 446.8287 446.9557 447.0827 447.2097 447.3366 447.4636 447.5905 447.7174 447.8443 447.9712 448.0981 448.2250 448.3518 448.4787 448.6055 448.7323 448.8590 448.9858 449.1126 449.2393 449.3660 449.4927 449.6194 449.7461 449.8728 449.9994 450.1261 450.2527 450.3793 450.5059 450.6324 450.7590 450.8855 451.0120 451.1386 451.2651 451.3915 451.5180 451.6444 451.7709 451.8973 452.0237 452.1501 452.2765 452.4028 452.5291 452.6555 452.7818 452.9081 453.0344 453.1606 453.2869 453.4131 453.5393 453.6655 453.7917 453.9179 454.0440 454.1702 454.2963 454.4224 454.5485 454.6746 454.8007 454.9267 455.0527 455.1788 455.3048 455.4307 455.5567 455.6827 455.8086 455.9345 456.0604 456.1863 456.3122 456.4381 456.5639 456.6898 456.8156 456.9414 457.0672 457.1929 457.3187 457.4444 457.5701 457.6959 457.8215 457.9472 458.0729 458.1985 458.3242 458.4498 458.5754 458.7010 458.8265 458.9521 459.0776 459.2031 459.3286 459.4541 459.5796 459.7051 459.8305 459.9559 460.0814 460.2068 460.3321 460.4575 460.5829 460.7082 460.8335 460.9588 461.0841 461.2094 461.3346 461.4599 461.5851 461.7103 461.8355 461.9607 462.0858 462.2110 462.3361 462.4612 462.5863 462.7114 462.8365 462.9615 463.0866 463.2116 463.3366 463.4616 463.5866 463.7115 463.8365 463.9614 464.0863 464.2112 464.3361 464.4610 464.5858 464.7106 464.8355 464.9603 465.0850 465.2098 465.3346 465.4593 465.5840 465.7087 465.8334 465.9581 466.0828 466.2074 466.3320 466.4566 466.5812 466.7058 466.8304 466.9549 467.0795 467.2040 467.3285 467.4530 467.5775 467.7019 467.8263 467.9508 468.0752 468.1996 468.3239 468.4483 468.5726 468.6970 468.8213 468.9456 469.0699 469.1941 469.3184 469.4426 469.5668 469.6910 469.8152 469.9394
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Water vapor effective temperature [K]
Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Molecular iodine effective temperature [K]
Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Nitrogen dioxide effective temperature [K]
Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful
Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 60: Oxygen dimer effective temperature [K]
Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful
Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 71: Ozone effective temperature [K]
Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 82: Iodine dioxide effective temperature [K]
Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful
Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 90: Lower limit used for wavelength scaling [nm]
Column 91: Upper limit used for wavelength scaling [nm]
Column 92: Order of smoothing polynomial
Column 93: Smoothing polynomial coefficient, order 0
Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 98: Smoothing polynomial coefficient, order 1
Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 103: Smoothing polynomial coefficient, order 2
Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 108: Smoothing polynomial coefficient, order 3
Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 113: Smoothing polynomial coefficient, order 4
Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 118: Mean value of measured data inside fitting window [same units as measurements]
Column 119: Offset polynomial coefficient, order 0
Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 124: Wavelength change polynomial coefficient, order 0
Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 129: Wavelength change polynomial coefficient, order 1
Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful
Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 136: Resolution change polynomial coefficient, order 0
Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 148: Wavelength effective temperature [�C], 999=no effective temperature given
Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 152: Number of bright count cycles
Column 153: Number of dark count cycles
Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 157: Integration time [ms]
Column 158: Temperature at electronics board [�C], 999=no temperature signal
Column 159: Spectrometer control temperature [�C], 999=no temperature signal
Column 160: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Column 161: Temperature in head sensor [�C], 999=no temperature signal
Column 162: Humidity in head sensor [%], -9=no humidity signal
Column 163: Pressure in head sensor [hPa], -9=no pressure signal
Columns 164-709: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 710-1255: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------