File name: Pandora249s1_ChicagoIL_20240122_L2Fit_fnvs4c2d20230104p1-8.txt File generation date: 20240123T060526.5Z Data description: Level 2 spectral fitting results file Data file version: fnvs4c2p1-8 Local principal investigator: John Randazzo Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 249 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora249_OF_v2d20221026.txt Instrument calibration file used: Pandora249s1_CF_v2d20230104.txt Level 1 file used: Pandora249s1_ChicagoIL_20240122_L1_smca1c2d20230104p1-8.txt Full location name: North Park University Chicago Short location name: ChicagoIL Country of location: United States Location latitude [deg]: 41.9748 Location longitude [deg]: -87.7120 Location altitude [m]: 200 Local noon date: 20240122 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OoB session based on session 1 First and last pixel inside fitting window: 888 1434 Nominal wavelengths inside fitting window [nm]: 400.0592 400.1911 400.3230 400.4549 400.5868 400.7186 400.8505 400.9823 401.1142 401.2460 401.3778 401.5095 401.6413 401.7731 401.9048 402.0365 402.1682 402.2999 402.4316 402.5633 402.6949 402.8265 402.9582 403.0898 403.2214 403.3530 403.4845 403.6161 403.7476 403.8791 404.0106 404.1421 404.2736 404.4051 404.5365 404.6680 404.7994 404.9308 405.0622 405.1936 405.3249 405.4563 405.5876 405.7189 405.8502 405.9815 406.1128 406.2441 406.3753 406.5066 406.6378 406.7690 406.9002 407.0314 407.1625 407.2937 407.4248 407.5559 407.6870 407.8181 407.9492 408.0803 408.2113 408.3424 408.4734 408.6044 408.7354 408.8664 408.9973 409.1283 409.2592 409.3901 409.5210 409.6519 409.7828 409.9136 410.0445 410.1753 410.3061 410.4369 410.5677 410.6985 410.8293 410.9600 411.0907 411.2214 411.3521 411.4828 411.6135 411.7442 411.8748 412.0054 412.1360 412.2666 412.3972 412.5278 412.6584 412.7889 412.9194 413.0499 413.1804 413.3109 413.4414 413.5718 413.7023 413.8327 413.9631 414.0935 414.2239 414.3543 414.4846 414.6149 414.7453 414.8756 415.0059 415.1361 415.2664 415.3967 415.5269 415.6571 415.7873 415.9175 416.0477 416.1778 416.3080 416.4381 416.5682 416.6983 416.8284 416.9585 417.0886 417.2186 417.3486 417.4786 417.6086 417.7386 417.8686 417.9986 418.1285 418.2584 418.3883 418.5182 418.6481 418.7780 418.9078 419.0377 419.1675 419.2973 419.4271 419.5569 419.6866 419.8164 419.9461 420.0758 420.2055 420.3352 420.4649 420.5946 420.7242 420.8538 420.9835 421.1131 421.2426 421.3722 421.5018 421.6313 421.7608 421.8904 422.0199 422.1493 422.2788 422.4083 422.5377 422.6671 422.7965 422.9259 423.0553 423.1847 423.3140 423.4433 423.5727 423.7020 423.8313 423.9605 424.0898 424.2190 424.3483 424.4775 424.6067 424.7359 424.8650 424.9942 425.1233 425.2525 425.3816 425.5107 425.6397 425.7688 425.8979 426.0269 426.1559 426.2849 426.4139 426.5429 426.6718 426.8008 426.9297 427.0586 427.1875 427.3164 427.4453 427.5742 427.7030 427.8318 427.9606 428.0894 428.2182 428.3470 428.4757 428.6045 428.7332 428.8619 428.9906 429.1193 429.2479 429.3766 429.5052 429.6338 429.7624 429.8910 430.0196 430.1481 430.2767 430.4052 430.5337 430.6622 430.7907 430.9192 431.0476 431.1761 431.3045 431.4329 431.5613 431.6897 431.8180 431.9464 432.0747 432.2030 432.3313 432.4596 432.5879 432.7161 432.8444 432.9726 433.1008 433.2290 433.3572 433.4854 433.6135 433.7416 433.8698 433.9979 434.1260 434.2540 434.3821 434.5101 434.6382 434.7662 434.8942 435.0222 435.1501 435.2781 435.4060 435.5340 435.6619 435.7898 435.9176 436.0455 436.1734 436.3012 436.4290 436.5568 436.6846 436.8124 436.9401 437.0679 437.1956 437.3233 437.4510 437.5787 437.7064 437.8340 437.9617 438.0893 438.2169 438.3445 438.4721 438.5996 438.7272 438.8547 438.9822 439.1097 439.2372 439.3647 439.4921 439.6196 439.7470 439.8744 440.0018 440.1292 440.2566 440.3839 440.5113 440.6386 440.7659 440.8932 441.0204 441.1477 441.2749 441.4022 441.5294 441.6566 441.7838 441.9109 442.0381 442.1652 442.2924 442.4195 442.5466 442.6736 442.8007 442.9277 443.0548 443.1818 443.3088 443.4358 443.5627 443.6897 443.8166 443.9436 444.0705 444.1974 444.3243 444.4511 444.5780 444.7048 444.8316 444.9584 445.0852 445.2120 445.3387 445.4655 445.5922 445.7189 445.8456 445.9723 446.0990 446.2256 446.3522 446.4789 446.6055 446.7321 446.8586 446.9852 447.1117 447.2383 447.3648 447.4913 447.6178 447.7442 447.8707 447.9971 448.1235 448.2499 448.3763 448.5027 448.6291 448.7554 448.8817 449.0081 449.1344 449.2606 449.3869 449.5132 449.6394 449.7656 449.8918 450.0180 450.1442 450.2704 450.3965 450.5226 450.6487 450.7748 450.9009 451.0270 451.1530 451.2791 451.4051 451.5311 451.6571 451.7831 451.9090 452.0350 452.1609 452.2868 452.4127 452.5386 452.6645 452.7903 452.9162 453.0420 453.1678 453.2936 453.4193 453.5451 453.6709 453.7966 453.9223 454.0480 454.1737 454.2993 454.4250 454.5506 454.6762 454.8018 454.9274 455.0530 455.1786 455.3041 455.4296 455.5551 455.6806 455.8061 455.9316 456.0570 456.1825 456.3079 456.4333 456.5587 456.6840 456.8094 456.9347 457.0601 457.1854 457.3107 457.4359 457.5612 457.6865 457.8117 457.9369 458.0621 458.1873 458.3125 458.4376 458.5627 458.6879 458.8130 458.9381 459.0631 459.1882 459.3132 459.4383 459.5633 459.6883 459.8133 459.9382 460.0632 460.1881 460.3130 460.4379 460.5628 460.6877 460.8125 460.9374 461.0622 461.1870 461.3118 461.4366 461.5614 461.6861 461.8108 461.9355 462.0602 462.1849 462.3096 462.4342 462.5589 462.6835 462.8081 462.9327 463.0573 463.1818 463.3064 463.4309 463.5554 463.6799 463.8044 463.9288 464.0533 464.1777 464.3021 464.4265 464.5509 464.6753 464.7996 464.9240 465.0483 465.1726 465.2969 465.4212 465.5454 465.6697 465.7939 465.9181 466.0423 466.1665 466.2906 466.4148 466.5389 466.6630 466.7871 466.9112 467.0353 467.1593 467.2834 467.4074 467.5314 467.6554 467.7793 467.9033 468.0272 468.1512 468.2751 468.3990 468.5228 468.6467 468.7706 468.8944 469.0182 469.1420 469.2658 469.3895 469.5133 469.6370 469.7607 469.8844 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-710: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 711-1257: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------