File name: Pandora249s1_ChicagoIL_20241103_L2Fit_ffus5c3d20230501p1-8.txt File generation date: 20241105T125814.8Z Data description: Level 2 spectral fitting results file Data file version: ffus5c3p1-8 Local principal investigator: John Randazzo Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 249 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora249_OF_v2d20221026.txt Instrument calibration file used: Pandora249s1_CF_v3d20230501.txt Level 1 file used: Pandora249s1_ChicagoIL_20241103_L1_smca1c3d20230501p1-8.txt Full location name: North Park University Chicago Short location name: ChicagoIL Country of location: United States Location latitude [deg]: 41.9748 Location longitude [deg]: -87.7120 Location altitude [m]: 200 Local noon date: 20241103 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: based on session 2"OoB session" for fieldcal First and last pixel inside fitting window: 317 583 Nominal wavelengths inside fitting window [nm]: 322.5246 322.6640 322.8033 322.9427 323.0821 323.2214 323.3607 323.5001 323.6394 323.7787 323.9179 324.0572 324.1965 324.3357 324.4750 324.6142 324.7534 324.8926 325.0318 325.1709 325.3101 325.4493 325.5884 325.7275 325.8666 326.0057 326.1448 326.2839 326.4230 326.5620 326.7010 326.8401 326.9791 327.1181 327.2571 327.3960 327.5350 327.6740 327.8129 327.9518 328.0907 328.2297 328.3685 328.5074 328.6463 328.7851 328.9240 329.0628 329.2016 329.3404 329.4792 329.6180 329.7568 329.8955 330.0343 330.1730 330.3117 330.4504 330.5891 330.7278 330.8665 331.0052 331.1438 331.2824 331.4211 331.5597 331.6983 331.8369 331.9754 332.1140 332.2525 332.3911 332.5296 332.6681 332.8066 332.9451 333.0836 333.2220 333.3605 333.4989 333.6374 333.7758 333.9142 334.0526 334.1909 334.3293 334.4677 334.6060 334.7443 334.8826 335.0209 335.1592 335.2975 335.4358 335.5740 335.7123 335.8505 335.9887 336.1269 336.2651 336.4033 336.5415 336.6796 336.8178 336.9559 337.0940 337.2322 337.3702 337.5083 337.6464 337.7845 337.9225 338.0605 338.1986 338.3366 338.4746 338.6126 338.7505 338.8885 339.0264 339.1644 339.3023 339.4402 339.5781 339.7160 339.8539 339.9917 340.1296 340.2674 340.4053 340.5431 340.6809 340.8187 340.9564 341.0942 341.2320 341.3697 341.5074 341.6451 341.7828 341.9205 342.0582 342.1959 342.3335 342.4712 342.6088 342.7464 342.8840 343.0216 343.1592 343.2968 343.4343 343.5719 343.7094 343.8469 343.9844 344.1219 344.2594 344.3969 344.5343 344.6718 344.8092 344.9466 345.0840 345.2214 345.3588 345.4962 345.6335 345.7709 345.9082 346.0455 346.1828 346.3201 346.4574 346.5947 346.7319 346.8692 347.0064 347.1436 347.2809 347.4180 347.5552 347.6924 347.8296 347.9667 348.1038 348.2410 348.3781 348.5152 348.6523 348.7893 348.9264 349.0634 349.2005 349.3375 349.4745 349.6115 349.7485 349.8855 350.0224 350.1594 350.2963 350.4332 350.5701 350.7070 350.8439 350.9808 351.1177 351.2545 351.3913 351.5282 351.6650 351.8018 351.9386 352.0753 352.2121 352.3488 352.4856 352.6223 352.7590 352.8957 353.0324 353.1691 353.3057 353.4424 353.5790 353.7156 353.8522 353.9888 354.1254 354.2620 354.3986 354.5351 354.6716 354.8082 354.9447 355.0812 355.2177 355.3541 355.4906 355.6270 355.7635 355.8999 356.0363 356.1727 356.3091 356.4455 356.5818 356.7182 356.8545 356.9908 357.1271 357.2634 357.3997 357.5360 357.6722 357.8085 357.9447 358.0809 358.2171 358.3533 358.4895 358.6257 358.7618 358.8980 359.0341 359.1702 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-436: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 437-703: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20241103T161333.0Z 9073.676076 166 1 54.11 2 60.29 157.43 79.64 140.55 0.00 1 0.00 1 0 33 9.679e-04 9.304e-04 5.141e-04 4.914e-04 6.841228e-07 1.597119e-07 5.440610e-08 4.231926e-07 3.093511e-07 223.89 -2.00 3.53 -2.00 339.86 0.00e+00 1.253663e-04 4.387539e-05 1.067615e-05 1.115666e-05 8.555645e-05 279.88 -2.00 20.00 -2.00 337.29 0.00e+00 2.058388e-05 6.807522e-06 1.888227e-06 2.818911e-05 1.471931e-05 279.88 -2.00 20.00 -2.00 346.10 0.00e+00 2.802588e-04 1.975201e-05 1.564549e-05 8.921500e-06 4.175980e-05 279.88 -2.00 20.00 -2.00 344.67 0.00e+00 2.687122e+05 4.027419e+04 3.107511e+04 2.210906e+05 7.888119e+04 261.46 -2.00 11.25 -2.00 352.01 0.00e+00 2.262870e-01 6.008756e-04 1.885572e-03 5.229548e-04 1.033094e-03 223.89 -2.00 3.53 -2.00 330.08 0.00e+00 1.770274e-04 8.016032e-04 8.223871e-04 1.006129e-04 1.183785e-03 279.88 -2.00 20.00 -2.00 328.00 0.00e+00 2.009 0.000 319.50 362.20 4 4.8427e+00 6.7055e-04 1.3866e-02 1.6042e-03 1.3932e-03 2.8087e-02 1.6297e-04 2.1594e-03 2.8224e-04 3.1887e-04 -2.3340e-03 3.1168e-04 3.6737e-04 8.0348e-05 6.1373e-04 -5.0217e-04 1.5448e-04 3.5226e-04 1.9390e-05 2.5429e-04 5.3303e-04 2.4850e-04 2.7529e-04 5.8420e-05 4.5912e-04 1.9962e-03 -2.4459e-03 4.0833e-04 1.8673e-04 7.2247e-05 8.0453e-04 -1.2498e-04 7.1972e-06 2.6304e-06 6.2797e-07 1.4847e-05 -1.5520e-02 0.0000e+00 -5.8985e-01 4.3371e-02 1.4480e-02 4.1746e-03 8.5699e-02 12 8 8 10 0 0 99.99 25.22 0.25 -0.01552 -0.01706 65 7 1 5 0 832.420 32.50 19.98 25.22 18.53 9.5 921.54 34 102 -63 -98 130 145 -93 303 187 -109 8 -52 -103 -170 -6 -158 -11 206 -64 34 -206 109 140 66 -109 -109 9 96 117 -89 -96 -117 -91 -7 -22 -66 -18 177 81 17 49 -6 -6 -147 126 185 -33 -27 -161 -34 84 124 -101 -80 121 -34 -175 81 -57 8 -4 -73 -115 19 -77 -4 -18 -39 3 148 -9 -113 38 52 263 -22 154 126 -46 181 -63 -69 -77 32 15 113 -66 -48 64 15 40 95 -131 -121 46 38 72 -46 -134 -29 -28 -31 53 112 26 18 23 -123 -99 -61 52 -6 49 46 -83 -68 82 -90 -10 208 -72 153 16 57 -5 -123 14 -16 -27 77 -53 61 42 -23 -52 -82 -18 11 -57 -59 9 -8 -38 -102 116 40 56 -51 -57 23 -85 49 -90 -86 68 -31 -23 -130 35 54 162 77 210 140 -67 30 -97 33 -38 140 13 -220 70 101 -17 31 -96 -21 16 -13 17 -110 -23 -89 -128 25 40 -97 -66 2 62 -28 72 -43 -67 28 -92 -66 118 84 -152 43 202 -11 52 76 -114 -101 22 -29 -123 96 16 8 -51 72 47 49 18 75 -44 -19 -11 3 141 78 -40 77 63 2 -56 -51 10 -50 48 -32 19 16 9 -114 32 -9 75 -30 -192 144 -57 -320 120 -45 -54 120 81 125 -5 140 -92 130 -162 -264 106 -226 -191 111 26 102 79 20 60 -36 -58 77 91 -61 202 122 -74 5 -37 -75 -126 -4 -113 -7 146 -45 24 -157 85 112 57 -93 -96 8 83 101 -78 -85 -104 -80 -6 -19 -57 -16 149 70 15 41 -5 -5 -124 107 157 -30 -25 -154 -34 84 125 -99 -79 123 -34 -169 75 -52 7 -3 -66 -106 17 -69 -3 -18 -39 3 141 -8 -106 36 50 254 -21 149 121 -43 169 -57 -63 -72 30 15 111 -67 -48 63 15 40 94 -133 -127 48 37 68 -40 -112 -26 -26 -30 50 102 23 16 21 -112 -96 -62 52 -6 47 44 -82 -68 85 -94 -11 215 -72 148 16 58 -5 -138 16 -17 -30 82 -56 63 44 -23 -54 -86 -19 11 -59 -64 10 -9 -42 -109 125 42 61 -56 -63 26 -95 54 -97 -92 69 -28 -20 -114 31 50 162 81 226 155 -73 33 -109 36 -40 143 13 -225 75 109 -18 35 -109 -24 18 -14 18 -108 -23 -91 -140 26 43 -106 -70 2 66 -30 75 -44 -70 29 -95 -70 133 96 -180 52 240 -13 62 87 -131 -111 24 -31 -135 109 19 10 -57 78 49 49 18 80 -49 -22 -12 4 165 94 -48 92 75 2 -68 -62 12 -60 58 -39 22 19 10 -132 37 -10 86 -35 -222 164 -63 -334 121 -44 -53 120 82 133 -5 149 -95 127 -150 -237 91 -197 -172 103 26 107 86 SS 20241103T161744.9Z 9073.678992 169 1 5.94 2 60.00 158.55 79.17 141.35 0.00 1 0.00 1 0 33 9.687e-04 9.441e-04 7.874e-04 7.550e-04 2.564047e-07 2.453551e-07 5.402132e-08 4.231919e-07 3.096292e-07 223.89 -2.00 3.53 -2.00 339.88 0.00e+00 3.299132e-05 6.759974e-05 1.218036e-05 1.115728e-05 8.589618e-05 279.88 -2.00 20.00 -2.00 337.31 0.00e+00 2.300629e-05 1.045426e-05 1.497725e-06 2.818912e-05 1.470756e-05 279.88 -2.00 20.00 -2.00 346.10 0.00e+00 1.798464e-04 3.033487e-05 1.342619e-05 8.918544e-06 4.181396e-05 279.88 -2.00 20.00 -2.00 344.67 0.00e+00 1.938788e+05 6.186609e+04 2.919338e+04 2.210887e+05 7.911765e+04 261.46 -2.00 11.25 -2.00 352.02 0.00e+00 2.240541e-01 9.202842e-04 1.877262e-03 5.229455e-04 1.033853e-03 223.89 -2.00 3.53 -2.00 330.01 0.00e+00 1.275890e-03 1.213911e-03 3.693394e-04 9.936784e-05 1.184152e-03 279.88 -2.00 20.00 -2.00 327.92 0.00e+00 1.992 0.000 319.50 362.20 4 3.4938e+00 1.0316e-03 1.3741e-02 1.6042e-03 1.3986e-03 1.5700e-02 2.5192e-04 2.1394e-03 2.8232e-04 3.2078e-04 -9.2870e-04 4.7957e-04 3.6326e-04 8.0134e-05 6.1520e-04 -6.4502e-04 2.3516e-04 3.3316e-04 1.9317e-05 2.5477e-04 4.0296e-04 3.8174e-04 2.4941e-04 5.8376e-05 4.6106e-04 7.8251e-03 -3.4675e-03 6.2388e-04 1.9202e-04 7.3039e-05 8.0391e-04 -7.0159e-05 1.1042e-05 2.5847e-06 6.1290e-07 1.4860e-05 -1.6225e-02 0.0000e+00 -6.6568e-01 6.6650e-02 1.4525e-02 4.2336e-03 8.5826e-02 12 9 9 12 1 1 90.75 25.22 0.30 -0.01622 -0.01709 15 15 1 5 0 371.150 32.50 20.00 25.22 18.82 9.6 924.30 -84 125 67 -23 -18 104 97 98 34 57 -11 -68 -222 32 -163 27 -241 -29 -175 169 38 93 104 26 56 40 -17 -85 -70 64 -94 27 -87 -4 99 168 20 -45 -130 -95 78 54 105 77 -151 1 -21 114 -100 29 -79 -76 48 -94 80 -95 -60 -4 -155 -88 9 53 -28 35 -150 140 230 -159 159 154 112 -115 53 -41 75 58 130 -69 -16 153 47 20 19 113 3 47 -71 -137 142 -15 -46 118 -136 -135 -59 16 -1 127 50 -107 38 -34 125 16 50 -131 -85 -119 -166 -199 79 61 59 58 -42 -114 143 -99 34 70 -51 247 -9 -33 -35 -53 -19 68 -151 -5 25 137 16 -18 95 51 -11 10 -72 -123 -96 21 9 1 14 66 -85 -148 93 2 -153 103 -63 -88 -34 2 -90 -17 22 66 25 55 47 90 -11 126 33 37 -39 9 167 -163 53 -18 -45 -97 9 56 31 6 103 -125 80 57 -16 -15 -49 66 20 69 37 2 -16 -70 11 -5 -99 -51 196 -1 -91 -15 8 -10 19 103 -40 -71 169 -219 6 -151 24 28 -74 -8 16 -36 36 -37 -4 92 101 -25 123 40 -79 -24 126 -82 104 -31 -25 11 94 -26 -36 -86 -83 -36 158 -13 41 42 -99 119 -39 -170 117 -71 -244 78 54 -169 158 44 -70 75 -226 -318 113 -51 -98 207 -94 157 143 -52 76 40 -14 -11 67 62 64 23 39 -8 -50 -162 24 -120 20 -173 -21 -122 122 29 74 84 22 47 35 -15 -73 -60 56 -83 24 -77 -4 87 147 17 -39 -109 -81 66 46 90 66 -129 1 -19 105 -96 27 -77 -75 48 -93 80 -92 -57 -3 -139 -79 8 49 -26 32 -138 131 216 -154 153 144 106 -107 50 -39 73 55 124 -66 -15 140 43 18 18 105 3 47 -71 -137 139 -14 -45 118 -138 -143 -61 16 -1 111 42 -96 35 -33 117 15 44 -114 -76 -111 -162 -199 78 58 56 56 -41 -115 147 -104 36 72 -51 243 -9 -34 -38 -58 -21 75 -167 -6 26 143 17 -18 98 53 -11 10 -74 -131 -106 23 10 1 15 71 -94 -165 104 2 -168 112 -68 -93 -34 2 -82 -15 20 62 25 57 50 97 -12 139 36 40 -41 9 167 -169 56 -20 -49 -106 10 64 34 6 105 -124 81 60 -17 -17 -53 70 22 74 40 3 -16 -71 12 -5 -104 -55 215 -1 -109 -18 10 -12 22 119 -46 -79 183 -238 7 -172 28 32 -83 -8 17 -36 37 -39 -5 104 118 -28 144 47 -93 -29 149 -98 125 -37 -30 13 114 -32 -43 -101 -96 -41 179 -15 47 49 -116 135 -42 -179 118 -70 -240 78 55 -179 171 47 -73 74 -211 -284 99 -46 -88 190 -93 166 156 SS 20241103T162143.5Z 9073.681754 172 1 54.45 2 59.74 159.62 78.73 142.12 0.00 1 0.00 1 0 33 7.147e-04 6.968e-04 3.250e-04 3.113e-04 4.618811e-07 1.012934e-07 4.557918e-08 4.231938e-07 2.284340e-07 223.89 -2.00 3.53 -2.00 339.86 0.00e+00 1.671554e-04 2.783633e-05 9.693245e-06 1.115372e-05 6.325047e-05 279.88 -2.00 20.00 -2.00 337.30 0.00e+00 2.220488e-05 4.316825e-06 1.616873e-06 2.818911e-05 1.086022e-05 279.88 -2.00 20.00 -2.00 346.09 0.00e+00 2.372045e-04 1.249823e-05 1.399514e-05 8.926531e-06 3.084093e-05 279.88 -2.00 20.00 -2.00 344.66 0.00e+00 2.608933e+05 2.550011e+04 2.932342e+04 2.210879e+05 5.829837e+04 261.46 -2.00 11.25 -2.00 352.02 0.00e+00 2.233791e-01 3.787960e-04 1.865623e-03 5.229354e-04 7.622372e-04 223.89 -2.00 3.53 -2.00 330.03 0.00e+00 -4.642276e-04 5.026184e-04 7.619696e-04 9.945468e-05 8.739701e-04 279.88 -2.00 20.00 -2.00 327.95 0.00e+00 1.976 0.000 319.50 362.20 4 3.9934e+00 4.2483e-04 1.3635e-02 1.6042e-03 1.0299e-03 1.9726e-02 1.0340e-04 2.1231e-03 2.8229e-04 2.3598e-04 -1.2260e-03 1.9744e-04 3.5247e-04 8.0076e-05 4.5342e-04 -5.8067e-04 9.7223e-05 3.4363e-04 1.9351e-05 1.8788e-04 3.0660e-04 1.5721e-04 2.5640e-04 5.8190e-05 3.3952e-04 4.7807e-03 -1.7145e-03 2.5860e-04 1.9136e-04 7.2772e-05 5.9323e-04 -1.0023e-04 4.5604e-06 2.5975e-06 6.2011e-07 1.0963e-05 -1.5796e-02 0.0000e+00 -5.9294e-01 2.7512e-02 1.4532e-02 4.2543e-03 6.3403e-02 11 8 0 10 0 0 99.99 25.24 0.30 -0.01580 -0.01703 119 12 1 5 0 457.510 32.50 20.01 25.24 19.25 9.6 927.51 -85 33 165 -88 82 79 26 147 104 -84 33 -41 -119 -131 -12 17 -61 -58 -31 68 1 60 30 13 12 -82 -10 100 6 -70 -89 -42 -12 -2 -42 -53 9 93 -69 32 82 9 28 67 -24 120 79 -1 -87 17 21 69 -84 -73 19 -84 -76 91 -51 -16 -11 -79 -45 18 -61 -28 48 -59 40 42 93 -20 47 100 72 -2 46 -12 42 73 -99 -14 -32 57 -2 17 -57 -34 150 -5 80 90 -132 -54 -31 -43 11 5 -79 -26 -48 -18 46 -42 -20 61 7 -72 -73 -89 76 -7 5 129 -112 -31 163 -56 -43 73 -48 33 53 23 24 -61 49 0 -44 -1 63 63 11 -46 -15 25 -29 66 8 -64 -59 -25 37 -28 45 85 -66 -32 17 54 -45 16 21 -133 78 -101 -37 -68 51 27 123 9 63 123 -14 -33 43 46 -14 73 1 -123 63 9 -85 16 -30 7 -37 -59 68 -119 -140 -11 -56 -33 22 -17 -69 -9 47 -60 101 -52 -9 102 -28 -64 74 2 -88 53 74 -24 -28 125 -84 22 55 -59 -64 8 -14 -10 13 45 76 20 -64 25 -53 62 33 -22 81 63 -50 16 57 -88 51 -18 -41 -1 -24 40 18 -8 -54 -90 41 15 47 -40 -144 169 5 -227 147 81 -66 125 105 78 31 74 -21 33 -225 -239 57 -184 -91 124 -74 -3 128 -52 20 96 -53 50 51 17 97 71 -58 23 -30 -89 -96 -8 13 -43 -42 -22 49 1 47 24 11 11 -71 -9 86 5 -61 -78 -37 -10 -2 -37 -46 8 80 -58 27 70 8 24 57 -21 104 71 -1 -84 16 21 68 -84 -74 19 -81 -73 84 -45 -15 -10 -72 -42 17 -56 -26 46 -56 38 40 87 -19 46 98 70 -2 45 -11 40 67 -90 -13 -30 54 -2 17 -57 -34 148 -5 78 90 -137 -56 -32 -44 11 4 -67 -23 -44 -17 44 -38 -18 53 7 -68 -72 -89 75 -7 5 121 -109 -32 166 -58 -44 75 -49 33 54 24 26 -68 55 0 -48 -1 67 65 11 -48 -15 26 -29 67 9 -67 -64 -27 41 -29 48 90 -72 -35 19 60 -50 18 23 -139 77 -94 -33 -59 47 25 121 10 69 134 -16 -37 47 50 -15 74 1 -126 65 10 -94 17 -33 7 -40 -64 70 -120 -141 -11 -61 -37 24 -18 -75 -10 52 -63 103 -53 -9 105 -29 -68 82 2 -104 63 88 -28 -33 145 -95 24 59 -64 -71 9 -17 -11 15 49 78 20 -64 27 -59 70 39 -26 94 74 -60 20 69 -105 60 -21 -50 -2 -29 47 22 -9 -63 -102 46 17 55 -47 -168 193 5 -241 148 80 -64 125 107 82 34 79 -21 32 -211 -215 49 -161 -80 114 -72 -3 141 SS 20241103T170313.7Z 9073.710575 200 1 13.36 2 57.79 171.10 74.65 150.44 0.00 1 0.00 1 0 33 1.075e-03 1.062e-03 9.224e-04 8.830e-04 -2.300550e-07 2.868556e-07 4.255240e-08 4.231865e-07 3.436384e-07 223.89 -2.00 3.53 -2.00 339.90 0.00e+00 1.051633e-04 7.898509e-05 8.983693e-06 1.115842e-05 9.530444e-05 279.87 -2.00 20.00 -2.00 337.33 0.00e+00 2.162882e-05 1.220431e-05 1.401981e-06 2.818909e-05 1.633554e-05 279.87 -2.00 20.00 -2.00 346.14 0.00e+00 2.387379e-04 3.549599e-05 1.302410e-05 8.912841e-06 4.640140e-05 279.87 -2.00 20.00 -2.00 344.70 0.00e+00 2.259161e+05 7.234684e+04 2.626560e+04 2.210896e+05 8.776921e+04 261.45 -2.00 11.25 -2.00 352.03 0.00e+00 2.117286e-01 1.074406e-03 1.764424e-03 5.228879e-04 1.142462e-03 223.89 -2.00 3.53 -2.00 330.04 0.00e+00 1.364937e-03 1.425854e-03 6.684422e-04 1.007259e-04 1.314472e-03 279.87 -2.00 20.00 -2.00 327.95 0.00e+00 1.870 0.000 319.50 362.20 4 4.6588e+00 1.2074e-03 1.2901e-02 1.6043e-03 1.5558e-03 2.5640e-03 2.9544e-04 2.0086e-03 2.8234e-04 3.5646e-04 -1.5510e-03 5.6162e-04 3.3028e-04 8.0712e-05 6.8303e-04 -4.0776e-04 2.7587e-04 3.2106e-04 1.9346e-05 2.8253e-04 2.6006e-04 4.4662e-04 2.2976e-04 5.8793e-05 5.1134e-04 2.6598e-03 -3.9814e-03 7.3184e-04 1.7682e-04 7.3957e-05 8.9740e-04 -1.4327e-04 1.2958e-05 2.4275e-06 6.2935e-07 1.6490e-05 -1.6376e-02 0.0000e+00 -5.0910e-01 7.8423e-02 1.3416e-02 4.3908e-03 9.6020e-02 12 9 9 12 1 1 97.30 25.41 0.25 -0.01638 -0.01814 12 5 1 5 0 1027.590 32.50 20.00 25.41 19.65 9.4 926.68 -103 159 -27 102 314 26 -13 17 190 -131 107 -13 -130 -162 -83 -78 -118 27 -13 95 -82 -25 -41 -32 29 23 -67 146 -101 -23 -72 -74 -97 -144 146 -138 131 69 38 28 58 24 -96 47 12 177 5 38 109 -124 210 9 -67 -26 19 81 -102 249 -33 -77 -83 -57 -58 -16 9 39 112 -234 16 187 -6 -282 36 -70 115 -67 -37 108 -16 144 21 -47 -48 -257 -144 170 -39 13 17 -23 -63 194 -99 -2 -93 41 268 -12 18 158 1 -24 -45 102 173 -24 235 -6 -42 -142 59 -127 163 -27 -113 62 74 -57 14 -24 -20 87 -32 -58 94 -55 156 -1 -180 88 -17 -37 35 -230 109 80 -129 -110 -35 -115 -167 -14 -8 86 110 -25 60 -145 115 161 -102 44 74 -219 16 -52 -100 -12 -151 -67 255 2 180 154 36 45 -48 28 84 -31 21 22 54 -81 14 1 -87 -62 7 -57 -113 67 -8 -178 -79 -12 -8 -65 26 45 209 -163 2 -74 -58 172 -39 -185 82 91 -38 188 33 -114 -68 153 -39 -38 110 28 -3 -95 124 139 -12 -57 4 -173 39 140 -89 -89 55 -95 44 -22 -58 138 -56 -77 156 85 55 -92 183 -126 -8 -69 3 -6 26 -24 -6 -43 -192 109 124 -265 110 52 -43 67 50 -123 83 201 -108 -13 -135 -43 -33 -222 -111 144 -4 3 167 -62 96 -16 62 192 17 -8 11 128 -88 76 -10 -95 -120 -61 -56 -86 19 -9 67 -62 -19 -33 -27 25 21 -57 128 -88 -20 -62 -64 -87 -126 126 -120 114 59 33 24 49 21 -82 40 10 151 5 35 105 -120 205 9 -67 -26 19 78 -96 225 -30 -70 -74 -53 -54 -15 9 37 104 -225 15 173 -6 -270 34 -67 109 -63 -35 102 -15 132 19 -43 -44 -247 -139 170 -39 13 17 -22 -61 190 -103 -2 -95 40 246 -11 15 139 1 -23 -44 95 154 -21 205 -6 -41 -143 58 -124 153 -26 -110 64 75 -59 14 -24 -19 87 -32 -60 99 -62 172 -1 -199 94 -18 -38 36 -238 112 82 -129 -109 -36 -124 -184 -16 -8 91 118 -26 66 -161 127 178 -111 48 79 -235 16 -49 -89 -11 -136 -65 252 2 195 171 39 50 -53 31 88 -32 22 22 55 -87 15 1 -96 -69 8 -61 -115 68 -8 -184 -84 -13 -9 -69 28 49 225 -175 2 -76 -59 176 -41 -198 91 106 -46 224 39 -137 -80 179 -44 -42 117 29 -4 -107 145 163 -14 -61 5 -174 40 147 -99 -102 64 -109 51 -26 -70 166 -67 -93 188 103 67 -112 224 -154 -10 -82 3 -7 30 -27 -7 -50 -223 125 135 -285 110 51 -43 66 51 -131 90 215 -111 -13 -127 -39 -29 -196 -98 131 -4 3 183 SS 20241103T171521.7Z 9073.719001 209 1 19.91 2 57.51 174.55 73.63 152.98 0.00 1 0.00 1 0 33 1.990e-03 1.929e-03 1.442e-03 1.380e-03 4.939951e-07 4.468717e-07 1.165776e-07 4.232030e-07 6.356048e-07 223.89 -2.00 3.53 -2.00 339.76 0.00e+00 5.906581e-05 1.219569e-04 2.685414e-05 1.113861e-05 1.745489e-04 279.87 -2.00 20.00 -2.00 337.12 0.00e+00 -2.515911e-05 1.930699e-05 2.777981e-06 2.818881e-05 3.045369e-05 279.87 -2.00 20.00 -2.00 346.00 0.00e+00 2.625528e-04 5.561949e-05 1.482925e-05 8.934818e-06 8.578051e-05 279.87 -2.00 20.00 -2.00 344.53 0.00e+00 3.683217e+05 1.125914e+05 4.035833e+04 2.210813e+05 1.611195e+05 261.45 -2.00 11.25 -2.00 351.89 0.00e+00 2.123242e-01 1.670848e-03 1.807074e-03 5.227503e-04 2.109387e-03 223.89 -2.00 3.53 -2.00 330.03 0.00e+00 4.877958e-03 2.239924e-03 3.448022e-04 1.026683e-04 2.432230e-03 279.87 -2.00 20.00 -2.00 327.95 0.00e+00 1.855 0.000 319.50 362.20 4 5.8163e+00 1.8786e-03 1.2806e-02 1.6041e-03 2.8623e-03 3.9883e-02 4.5242e-04 1.9990e-03 2.8208e-04 6.4841e-04 -4.0374e-03 8.7090e-04 4.4775e-04 7.9496e-05 1.2532e-03 -3.5894e-04 4.3109e-04 3.1694e-04 1.9310e-05 5.1974e-04 1.9042e-04 6.9201e-04 3.0425e-04 5.7497e-05 9.3158e-04 8.4159e-04 -6.8606e-03 1.1523e-03 1.6713e-04 7.1747e-05 1.6825e-03 -1.1035e-04 2.0304e-05 2.5249e-06 6.2960e-07 3.0518e-05 -1.6706e-02 0.0000e+00 -4.3106e-01 1.2327e-01 1.2511e-02 4.1451e-03 1.7826e-01 12 9 9 12 1 1 99.89 25.43 0.39 -0.01671 -0.01807 7 2 1 5 0 2488.530 32.50 20.00 25.43 19.70 9.5 928.55 28 130 214 -123 205 20 -277 553 584 -77 -79 -526 -101 -238 67 -178 -297 -53 -297 537 31 343 26 -18 -251 63 48 274 -58 -221 -171 -162 97 71 -28 -232 -277 0 -84 407 -49 273 -131 -11 -7 523 144 -142 -130 -201 89 150 -145 -197 346 135 -78 91 14 71 -215 -55 -187 -96 -27 -224 -57 -128 172 48 151 16 82 50 400 33 109 78 -146 362 -147 -125 -63 35 -311 -9 -98 148 -75 -57 342 134 -16 -54 -196 48 248 -72 -352 -188 198 38 -360 79 263 141 18 7 165 -290 125 -156 -55 -160 90 -111 312 -194 71 314 -188 124 -93 75 -76 -304 -138 247 -50 79 27 88 85 -118 -288 -26 78 -196 22 155 -19 -303 -337 189 -98 -4 318 -170 260 82 23 85 138 -411 174 -276 -5 -189 77 -121 319 111 289 113 160 82 -160 371 -194 219 330 146 -72 71 -83 -113 -195 -162 157 73 20 -31 -229 -65 -235 21 -223 86 -335 -125 103 -42 -179 26 -201 139 57 -251 217 88 105 69 302 -280 267 267 -196 -230 63 -254 -86 156 -197 28 -110 45 361 -73 -274 445 -75 -102 -134 -199 274 -20 -16 -56 -57 240 118 -76 -15 -41 134 31 8 -296 -72 -64 226 185 101 -246 -357 364 86 -295 -6 97 -98 88 126 255 176 135 44 261 -213 -334 -17 -316 -92 67 -298 -123 237 16 77 124 -73 121 12 -180 364 394 -52 -55 -385 -75 -181 50 -131 -212 -37 -206 386 24 268 22 -15 -222 57 43 245 -51 -199 -157 -149 88 63 -25 -205 -244 0 -71 335 -40 228 -109 -9 -6 450 133 -133 -129 -196 88 149 -147 -201 347 131 -75 86 13 65 -202 -51 -172 -92 -25 -207 -54 -125 167 45 140 15 78 48 384 31 104 75 -136 340 -134 -115 -59 33 -304 -9 -102 154 -76 -55 336 136 -16 -58 -206 49 233 -63 -300 -163 190 37 -337 72 235 122 15 7 163 -286 127 -153 -52 -152 90 -112 321 -204 74 313 -190 122 -94 76 -84 -337 -157 277 -55 86 29 91 87 -122 -296 -28 80 -198 22 167 -20 -331 -362 206 -105 -5 343 -191 292 92 26 91 152 -440 177 -262 -4 -165 66 -116 319 115 304 122 175 90 -175 396 -208 220 340 147 -75 74 -90 -125 -222 -186 175 76 20 -30 -226 -68 -250 22 -239 91 -362 -136 110 -43 -184 26 -206 143 60 -266 245 103 124 84 361 -332 307 311 -224 -251 69 -277 -93 181 -228 32 -126 49 359 -74 -271 472 -83 -114 -153 -232 320 -23 -19 -67 -67 285 141 -91 -18 -50 166 38 10 -347 -81 -71 259 206 115 -286 -419 407 94 -312 -6 92 -95 87 125 261 189 144 43 254 -188 -289 -14 -266 -80 59 -288 -129 259