File name: Pandora67s1_Cologne_20210322_L2Fit_fsus1c2d20200629p1-8.txt File generation date: 20250409T105904.0Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Tom Hanisco Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 67 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora67_OF_v5d20191001.txt Instrument calibration file used: Pandora67s1_CF_v2d20200629.txt Level 1 file used: Pandora67s1_Cologne_20210322_L1_smca1c2d20200629p1-8.txt Full location name: Cologne Short location name: Cologne Country of location: Germany Location latitude [deg]: 50.9389 Location longitude [deg]: 6.9787 Location altitude [m]: 50 Local noon date: 20210322 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: 1.8 data preparation: field calibration First and last pixel inside fitting window: 284 429 Nominal wavelengths inside fitting window [nm]: 306.0589 306.1995 306.3401 306.4807 306.6212 306.7618 306.9023 307.0429 307.1834 307.3239 307.4644 307.6048 307.7453 307.8858 308.0262 308.1666 308.3071 308.4475 308.5879 308.7283 308.8686 309.0090 309.1494 309.2897 309.4300 309.5704 309.7107 309.8510 309.9912 310.1315 310.2718 310.4120 310.5523 310.6925 310.8327 310.9729 311.1131 311.2533 311.3934 311.5336 311.6737 311.8139 311.9540 312.0941 312.2342 312.3743 312.5144 312.6544 312.7945 312.9345 313.0745 313.2146 313.3546 313.4946 313.6345 313.7745 313.9145 314.0544 314.1943 314.3343 314.4742 314.6141 314.7540 314.8938 315.0337 315.1736 315.3134 315.4532 315.5930 315.7328 315.8726 316.0124 316.1522 316.2920 316.4317 316.5714 316.7112 316.8509 316.9906 317.1303 317.2699 317.4096 317.5493 317.6889 317.8285 317.9681 318.1077 318.2473 318.3869 318.5265 318.6660 318.8056 318.9451 319.0846 319.2242 319.3637 319.5031 319.6426 319.7821 319.9215 320.0610 320.2004 320.3398 320.4792 320.6186 320.7580 320.8974 321.0367 321.1761 321.3154 321.4547 321.5940 321.7333 321.8726 322.0119 322.1512 322.2904 322.4296 322.5689 322.7081 322.8473 322.9865 323.1257 323.2648 323.4040 323.5431 323.6822 323.8214 323.9605 324.0996 324.2387 324.3777 324.5168 324.6558 324.7949 324.9339 325.0729 325.2119 325.3509 325.4899 325.6288 325.7678 325.9067 326.0456 326.1846 326.3235 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210322T084822.3Z 7751.366925 261 1 50.63 2 61.71 129.71 97.80 33.77 0.00 1 0.00 1 0 49 1.300e-03 7.588e-04 4.923e-04 1.723e-04 8.994708e-07 6.402900e-08 3.407195e-08 3.883714e-07 5.973495e-07 225.75 -2.00 3.80 -2.00 321.71 0.00e+00 2.132475e-04 2.305009e-05 2.060969e-05 1.077969e-04 1.527963e-04 270.65 -2.00 20.00 -2.00 321.50 0.00e+00 2.987605e-04 3.128918e-05 6.695443e-06 2.674972e-05 2.794764e-04 270.65 -2.00 20.00 -2.00 321.57 0.00e+00 1.629852e-04 4.627466e-05 3.644505e-05 1.622568e-05 2.802628e-04 270.65 -2.00 20.00 -2.00 321.57 0.00e+00 3.298975e-01 2.498663e-04 1.112173e-04 1.461241e-03 1.635130e-03 224.40 0.18 0.00 0.15 2.83 318.09 0.00e+00 5.423736e-05 1.411338e-05 2.792663e-05 1.807585e-05 4.020884e-05 270.65 -2.00 20.00 -2.00 317.25 0.00e+00 2.099 0.000 303.00 329.40 4 5.1925e-01 6.2290e-04 2.0208e-02 1.9873e-03 5.0762e-03 1.7399e-02 8.9688e-04 2.2283e-03 3.3837e-04 5.4707e-03 -7.9346e-03 4.8652e-04 2.6995e-04 1.9612e-04 2.9683e-03 2.5858e-03 2.5112e-04 8.3328e-05 6.3594e-05 1.2042e-03 1.1738e-03 1.6269e-04 6.8409e-05 7.8314e-05 8.6774e-04 3.0279e-02 -2.0685e-03 8.4531e-05 2.3208e-05 1.1838e-05 2.0385e-04 1.8182e-04 5.0389e-06 1.6967e-06 1.6249e-06 3.9744e-05 -1.7890e-02 3.4721e-05 -1.9507e-01 1.3864e-02 1.9015e-03 4.6946e-04 9.0497e-02 10 0 0 10 0 0 99.99 20.48 0.24 -0.01789 -0.01650 2965 695 1 5 0 16.260 24.86 20.00 20.48 12.44 31.7 994.41 -551 -21 -281 -298 -219 176 17 215 140 169 315 44 13 -16 -122 189 62 136 274 35 -138 -169 73 160 -69 369 73 -437 -214 -324 -257 -82 56 -5 1 82 -33 98 63 69 43 50 -154 31 -127 -138 -5 -92 -33 53 -37 -61 -177 -55 -76 -11 91 26 -35 156 -113 61 89 20 89 -22 90 42 129 227 -18 112 45 49 103 -143 -122 -115 -116 -114 -45 18 45 34 188 14 75 43 -9 -29 117 15 -3 42 -56 -90 87 6 -115 -19 -56 -108 47 -53 20 -36 45 -53 -2 88 -10 -24 25 -61 52 81 24 -33 40 -217 112 -21 -51 64 -40 1 -32 8 56 -62 174 -30 -27 21 -41 -34 -2 -21 -1 -13 66 62 -24 49 -82 -20 -50 -2 -31 -33 -25 22 3 33 25 31 61 9 3 -4 -26 41 14 33 70 9 -35 -39 17 39 -18 107 21 -130 -62 -102 -86 -32 25 -2 0 43 -16 52 34 36 22 26 -79 17 -70 -80 -3 -59 -20 33 -24 -38 -115 -34 -51 -8 68 20 -26 111 -79 44 68 17 76 -19 74 34 100 160 -12 78 34 41 91 -131 -117 -117 -120 -124 -50 21 49 36 183 13 69 41 -9 -31 133 18 -4 49 -63 -94 91 7 -132 -23 -68 -137 61 -73 28 -50 59 -66 -3 106 -12 -31 33 -82 69 109 31 -42 49 -254 129 -26 -65 87 -55 2 -45 11 86 -94 270 -47 -42 32 -61 -49 -4 -33 -1 -22 116 112 -45 91 -153 -38 SS 20210322T085322.7Z 7751.370401 264 1 5.36 2 61.10 130.96 97.37 34.78 0.00 1 0.00 1 0 49 2.207e-03 1.126e-03 2.246e-03 8.817e-04 1.362523e-06 3.282760e-07 4.044223e-08 3.883652e-07 1.014199e-06 225.75 -2.00 3.80 -2.00 321.59 0.00e+00 4.123080e-05 1.170109e-04 1.812206e-05 1.078248e-04 2.596257e-04 270.65 -2.00 20.00 -2.00 321.35 0.00e+00 3.289586e-04 1.603049e-04 9.278495e-06 2.672344e-05 4.740495e-04 270.65 -2.00 20.00 -2.00 321.49 0.00e+00 5.400058e-04 2.308722e-04 4.026535e-05 1.624616e-05 4.758236e-04 270.65 -2.00 20.00 -2.00 321.45 0.00e+00 3.218873e-01 1.248721e-03 6.714352e-05 1.461341e-03 2.775051e-03 222.65 0.92 0.00 0.15 4.81 317.85 0.00e+00 8.546111e-05 6.783504e-05 4.125202e-06 1.805315e-05 6.815648e-05 270.65 -2.00 20.00 -2.00 317.01 0.00e+00 2.060 0.000 303.00 329.40 4 1.7100e+00 3.1211e-03 1.9828e-02 1.9875e-03 8.6218e-03 1.7479e-02 4.4250e-03 2.0986e-03 3.4088e-04 9.2918e-03 -8.0309e-03 2.4130e-03 2.2649e-04 1.9104e-04 5.0429e-03 -5.3038e-04 1.2117e-03 1.4485e-04 5.5805e-05 2.0396e-03 3.0367e-03 8.0344e-04 6.3769e-05 7.6776e-05 1.4614e-03 9.6283e-03 -2.2038e-03 4.2102e-04 2.2250e-05 1.0200e-05 3.6492e-04 -6.0812e-05 2.5634e-05 1.8188e-06 1.5998e-06 6.7530e-05 -1.7493e-02 -5.3752e-06 -3.2344e-02 7.0748e-02 1.8353e-03 5.9998e-04 1.5499e-01 12 9 1 12 1 1 98.91 20.50 0.20 -0.01749 -0.01796 64 143 1 5 0 79.710 24.86 20.00 20.50 13.18 32.1 1000.74 529 -69 -255 11 -625 447 -433 268 -690 629 191 777 9 317 -640 265 -83 109 206 316 -266 -454 224 308 -103 -357 96 -661 -162 -493 237 -37 250 36 -60 -43 -18 -69 -76 84 -191 -151 -126 300 -205 125 41 33 -195 341 -219 2 -79 -150 -131 -20 147 276 -92 217 59 -4 174 -45 15 -156 375 106 136 -47 62 141 66 -76 128 -175 -139 -141 -95 -203 -34 -15 -13 131 29 20 98 67 -101 -44 79 88 6 32 -134 -148 61 72 -98 -137 -1 -88 178 -143 48 -20 58 -171 68 165 42 -68 108 -96 99 132 90 -89 18 -175 106 34 -75 153 -81 -65 -6 30 26 -129 122 -50 -34 49 -3 -19 -9 -53 40 22 0 -38 -36 69 -68 54 56 -8 -33 1 -84 62 -70 49 -144 137 44 184 2 74 -149 62 -21 29 57 90 -72 -114 55 82 -29 -112 32 -213 -50 -168 85 -16 119 18 -31 -23 -10 -38 -41 45 -101 -79 -66 165 -123 74 26 22 -131 233 -151 1 -53 -102 -90 -15 112 216 -71 158 42 -3 138 -38 13 -138 318 88 108 -34 45 100 50 -66 117 -167 -138 -142 -102 -219 -37 -17 -14 137 29 19 92 62 -101 -47 90 108 7 37 -150 -160 65 81 -112 -165 -1 -113 231 -192 67 -27 76 -217 83 199 52 -87 141 -130 132 172 117 -109 22 -205 127 41 -96 200 -110 -91 -8 44 39 -192 186 -77 -51 73 -4 -27 -14 -80 63 36 -1 -69 -64 128 -126 99 SS 20210322T091030.8Z 7751.382300 270 1 3.52 2 59.13 135.34 95.83 38.20 0.00 1 0.00 1 0 49 2.119e-03 9.943e-04 1.958e-03 8.416e-04 8.613864e-07 3.147091e-07 4.329312e-08 3.883474e-07 9.775372e-07 225.75 -2.00 3.80 -2.00 321.49 0.00e+00 1.985599e-04 1.108965e-04 2.467267e-05 1.078372e-04 2.505137e-04 270.65 -2.00 20.00 -2.00 321.23 0.00e+00 2.247315e-04 1.529330e-04 7.586480e-06 2.668589e-05 4.534684e-04 270.65 -2.00 20.00 -2.00 321.41 0.00e+00 -4.393810e-05 2.160499e-04 2.281252e-05 1.626114e-05 4.568551e-04 270.65 -2.00 20.00 -2.00 321.35 0.00e+00 3.049046e-01 1.173769e-03 9.472429e-05 1.461323e-03 2.658685e-03 223.11 0.92 0.00 0.16 4.61 317.63 0.00e+00 1.429395e-04 6.127462e-05 3.126485e-05 1.807671e-05 6.518712e-05 270.65 -2.00 20.00 -2.00 316.79 0.00e+00 1.941 0.000 303.00 329.40 4 1.3107e+00 2.9786e-03 1.8684e-02 1.9871e-03 8.2775e-03 2.1635e-02 4.1587e-03 2.0998e-03 3.3960e-04 8.9183e-03 -6.5493e-03 2.2659e-03 2.3082e-04 1.8722e-04 4.8533e-03 -2.2796e-03 1.0945e-03 1.2116e-04 5.0651e-05 1.9539e-03 3.2375e-03 7.3641e-04 8.5616e-05 7.4998e-05 1.3699e-03 1.6532e-02 -2.8309e-03 4.2379e-04 2.3345e-05 1.0232e-05 4.0965e-04 1.4925e-04 2.4365e-05 1.6992e-06 1.5745e-06 6.4756e-05 -1.8011e-02 2.4883e-05 -1.6804e-01 6.9842e-02 2.3840e-03 6.6004e-04 1.5367e-01 12 9 1 12 1 1 99.84 20.52 0.24 -0.01801 -0.01687 74 256 1 5 0 44.460 24.86 20.00 20.52 13.69 31.7 1001.37 792 270 -215 -563 -609 609 -584 312 -476 -90 451 349 -717 11 338 644 123 313 -98 290 161 111 253 77 -131 119 71 -488 -461 -464 -130 -74 60 -90 122 -63 -135 99 115 -53 55 -128 -9 89 -95 -10 132 -76 -156 141 -150 -120 -193 203 -129 34 204 35 -100 -28 -84 47 133 0 164 -184 160 56 175 114 32 88 -87 -119 46 -105 52 -61 -26 -74 -160 92 23 38 140 25 67 13 -84 77 203 2 88 81 -110 -59 -62 17 -114 -99 -117 -40 19 -17 -40 -25 58 -63 -64 62 -13 -33 34 -131 101 60 124 -56 -7 -178 68 -7 -8 99 -88 94 -66 50 15 -21 150 -89 11 -31 16 17 32 -5 82 -92 5 25 17 99 -168 14 96 36 -32 -83 -92 94 -105 64 -110 -22 113 84 -181 3 85 166 34 91 -30 89 47 30 67 22 -40 40 26 -167 -152 -168 -50 -34 30 -47 66 -35 -78 56 65 -30 30 -70 -5 51 -59 -6 86 -51 -108 99 -106 -83 -132 141 -91 26 159 28 -79 -21 -61 35 106 0 145 -164 137 47 140 83 24 66 -70 -103 42 -100 51 -64 -28 -79 -176 102 25 39 140 24 62 13 -86 83 235 3 104 95 -121 -63 -66 19 -134 -116 -145 -50 26 -23 -55 -34 77 -80 -76 75 -16 -42 45 -173 135 78 156 -70 -8 -211 79 -8 -10 129 -121 126 -92 71 22 -31 225 -136 16 -46 24 25 47 -8 128 -151 9 45 31 180 -308 25 SS 20210322T092226.0Z 7751.390579 277 1 36.06 2 57.84 138.50 94.68 40.54 0.00 1 0.00 1 0 49 6.414e-03 2.147e-03 4.864e-03 1.652e-03 -2.332501e-07 6.147231e-07 5.629395e-08 3.883655e-07 2.960906e-06 225.75 -2.00 3.80 -2.00 321.81 0.00e+00 1.177397e-03 2.231796e-04 4.580837e-05 1.077985e-04 7.604189e-04 270.65 -2.00 20.00 -2.00 321.67 0.00e+00 4.453062e-04 3.022924e-04 1.409885e-05 2.674899e-05 1.367995e-03 270.65 -2.00 20.00 -2.00 321.65 0.00e+00 1.017819e-03 4.555012e-04 8.504432e-05 1.619418e-05 1.382876e-03 270.65 -2.00 20.00 -2.00 321.67 0.00e+00 2.954717e-01 2.388715e-03 1.873905e-04 1.461256e-03 8.028107e-03 218.75 1.89 0.00 0.17 13.92 318.23 0.00e+00 1.232211e-04 1.401547e-04 1.584813e-05 1.803243e-05 1.979915e-04 270.65 -2.00 20.00 -2.00 317.39 0.00e+00 1.872 0.000 303.00 329.40 4 4.7638e+00 5.6418e-03 1.8036e-02 1.9870e-03 2.4998e-02 3.3746e-02 8.3629e-03 2.1476e-03 3.3719e-04 2.6930e-02 6.3203e-03 4.6063e-03 5.1629e-04 1.9761e-04 1.4690e-02 -8.1099e-03 2.2966e-03 2.3880e-04 6.5564e-05 5.8836e-03 2.5513e-03 1.5022e-03 9.7566e-05 7.7816e-05 4.0808e-03 5.5189e-04 -2.2327e-03 1.0455e-03 1.0306e-04 1.6704e-05 1.3564e-03 3.4276e-04 4.9357e-05 2.7851e-06 1.6373e-06 1.9560e-04 -1.8603e-02 9.4151e-05 6.1677e-01 1.4337e-01 4.6840e-03 5.0892e-04 4.7348e-01 12 9 9 12 1 1 100.00 20.55 0.14 -0.01860 -0.01599 78 25 1 5 0 448.450 24.86 20.00 20.55 14.01 32.0 1003.26 -3485 409 885 1178 -733 65 -530 -2284 89 -560 460 -489 666 -1224 2407 -2060 484 -1033 1089 167 375 1470 2197 100 304 1437 -354 353 -532 25 -90 1797 -376 -665 198 235 -358 -35 -115 -98 -260 -380 297 86 -173 -436 -88 -253 141 -421 333 53 -98 -291 69 430 276 -484 -204 84 -133 344 -248 140 310 112 -134 -43 -161 249 -33 -128 -169 211 209 174 108 -264 -147 -112 -116 390 234 -220 139 -570 -235 98 -178 -344 234 408 95 156 134 -91 -128 -47 -341 -102 36 151 134 -19 111 69 113 -33 -81 -19 -69 -233 -74 -201 146 112 172 -90 112 -239 197 -70 -180 -21 -132 -109 -58 28 151 3 156 -114 -152 141 76 -9 106 -31 -61 -64 300 53 -117 27 -105 -17 -320 40 94 125 -81 8 -74 -368 15 -103 87 -97 135 -258 485 -443 108 -246 264 41 89 318 475 23 75 381 -99 96 -141 7 -29 658 -164 -315 95 117 -181 -17 -58 -50 -129 -186 144 44 -93 -248 -52 -156 88 -264 211 33 -60 -184 45 300 204 -368 -147 58 -89 237 -190 114 264 97 -112 -34 -118 171 -21 -86 -125 169 183 162 102 -263 -154 -121 -129 435 253 -228 135 -522 -209 90 -175 -364 269 490 113 181 148 -95 -134 -53 -399 -122 44 193 178 -27 156 97 150 -42 -97 -23 -84 -297 -100 -274 195 150 224 -112 135 -282 228 -85 -231 -28 -182 -151 -81 41 227 4 243 -182 -239 216 113 -13 156 -47 -99 -109 530 99 -221 52 -203 -32 SS 20210322T093325.1Z 7751.398208 283 1 48.29 2 56.73 141.48 93.57 42.66 0.00 1 0.00 1 0 49 7.829e-03 3.248e-03 5.430e-03 1.980e-03 -3.201709e-06 7.392373e-07 1.061621e-07 3.883470e-07 3.610539e-06 225.75 -2.00 3.80 -2.00 321.68 0.00e+00 2.361938e-03 2.660027e-04 8.199971e-05 1.078155e-04 9.291767e-04 270.65 -2.00 20.00 -2.00 321.50 0.00e+00 7.110843e-04 3.609705e-04 2.271069e-05 2.672706e-05 1.667512e-03 270.65 -2.00 20.00 -2.00 321.55 0.00e+00 1.894032e-03 5.385126e-04 1.767083e-04 1.621101e-05 1.688375e-03 270.65 -2.00 20.00 -2.00 321.55 0.00e+00 2.889876e-01 2.740225e-03 4.235313e-04 1.461222e-03 9.801023e-03 209.73 2.18 0.00 0.18 17.02 318.00 0.00e+00 -2.387396e-04 1.595584e-04 3.232845e-05 1.806367e-05 2.403422e-04 270.65 -2.00 20.00 -2.00 317.20 0.00e+00 1.817 0.000 303.00 329.40 4 5.5232e+00 6.2454e-03 1.7554e-02 1.9868e-03 3.0564e-02 2.9777e-02 9.1547e-03 2.8781e-03 3.3653e-04 3.2923e-02 2.5352e-02 5.1938e-03 1.0426e-03 1.9556e-04 1.7978e-02 -1.4637e-02 2.6322e-03 3.8870e-04 6.0841e-05 7.1973e-03 -1.6916e-04 1.7625e-03 1.7975e-04 7.6469e-05 4.9390e-03 2.7299e-04 -6.9699e-03 1.2253e-03 2.0651e-04 1.6351e-05 1.8045e-03 1.8796e-04 5.9435e-05 4.7358e-06 1.6224e-06 2.3884e-04 -1.8665e-02 7.8204e-05 1.4429e+00 1.7279e-01 9.1177e-03 5.2842e-04 5.8784e-01 12 8 8 10 0 0 99.97 20.56 0.16 -0.01867 -0.01723 38 9 1 5 0 1270.640 24.86 20.00 20.56 14.15 32.2 1004.30 -1599 2495 -243 2018 -151 3448 -281 269 -3051 1712 -368 65 -497 566 560 -561 438 -1357 -384 -709 -1326 896 2847 -2225 581 -558 581 -27 2071 -790 1136 2182 369 -59 255 -457 -10 -411 -1079 -361 -505 19 -463 173 -717 337 -424 527 -223 21 16 -15 -86 393 -239 827 257 -505 215 88 -232 -578 -352 400 219 196 381 150 592 98 -250 -611 -307 564 194 36 59 -104 -167 -298 -247 220 -105 173 -13 -196 -481 -384 -365 -371 579 542 64 192 43 -173 -115 -285 -370 -73 241 309 407 -306 245 114 344 -33 -24 -295 148 -625 -177 -79 98 401 94 -280 -436 -155 129 69 -193 158 -293 27 -119 213 -343 -11 407 128 -37 -11 32 -115 39 -178 192 -59 313 190 -168 318 -199 -293 -159 264 -29 234 -18 450 -43 45 -593 334 -76 14 -108 125 124 -129 104 -344 -100 -190 -339 211 646 -563 150 -158 173 -8 564 -242 382 832 164 -29 130 -239 -5 -216 -571 -190 -260 10 -235 91 -403 197 -262 331 -144 14 10 -10 -55 254 -163 597 197 -394 160 63 -160 -413 -274 333 189 171 324 122 442 68 -169 -419 -233 459 172 34 58 -105 -178 -325 -277 249 -117 181 -13 -184 -437 -358 -366 -399 671 653 77 223 48 -182 -121 -319 -434 -88 298 396 538 -424 347 158 460 -42 -29 -355 180 -796 -234 -106 132 533 122 -349 -526 -180 149 83 -244 209 -396 37 -167 307 -514 -17 628 200 -57 -17 47 -168 56 -269 305 -98 547 346 -312 600 -378 -547 SS 20210322T093842.2Z 7751.401878 286 1 50.49 2 56.22 142.94 93.02 43.68 0.00 1 0.00 1 0 49 1.091e-03 7.422e-04 2.480e-04 1.227e-04 5.443111e-07 4.639224e-08 3.430606e-08 3.883015e-07 5.038425e-07 225.75 -2.00 3.80 -2.00 321.27 0.00e+00 1.333738e-04 1.600141e-05 1.841476e-05 1.078703e-04 1.296156e-04 270.65 -2.00 20.00 -2.00 320.97 0.00e+00 2.909533e-04 2.225389e-05 7.121131e-06 2.662198e-05 2.323025e-04 270.65 -2.00 20.00 -2.00 321.26 0.00e+00 3.164818e-04 3.018759e-05 2.551229e-05 1.645605e-05 2.352276e-04 270.65 -2.00 20.00 -2.00 321.15 0.00e+00 2.840154e-01 1.657296e-04 6.512839e-05 1.461251e-03 1.364269e-03 223.99 0.14 0.00 0.17 2.37 317.22 0.00e+00 1.190412e-04 8.074195e-06 1.944577e-05 1.814337e-05 3.348684e-05 270.65 -2.00 20.00 -2.00 316.39 0.00e+00 1.793 0.000 303.00 329.40 4 1.8641e-01 4.3659e-04 1.7254e-02 1.9867e-03 4.2537e-03 1.4585e-02 5.8722e-04 1.8748e-03 3.3879e-04 4.5854e-03 -8.6125e-03 3.2270e-04 1.7628e-04 1.8232e-04 2.5050e-03 1.6931e-03 1.4714e-04 9.9076e-05 4.2924e-05 9.9867e-04 1.4376e-03 1.0055e-04 6.8528e-05 7.1148e-05 6.8397e-04 6.0057e-02 -1.3908e-03 6.5490e-05 1.7832e-05 9.8481e-06 2.5092e-04 -2.1201e-05 3.5396e-06 1.5441e-06 1.5648e-06 3.3332e-05 -1.7972e-02 -3.6627e-06 -1.6162e-01 1.0537e-02 2.0351e-03 7.7367e-04 8.2535e-02 10 0 0 10 0 0 98.01 20.57 0.27 -0.01797 -0.01813 3648 856 1 5 0 13.190 24.86 20.00 20.57 14.46 32.5 1008.63 -321 -87 -167 -356 -261 -41 -38 21 208 21 235 -37 72 5 -132 133 74 40 246 155 -10 -201 101 113 -92 415 64 -277 -114 -216 -97 25 -14 -18 -19 70 -54 92 12 16 0 9 -114 74 -70 -76 -11 -98 5 -1 -55 -52 -140 -93 -83 10 92 -25 -85 96 -158 71 89 -3 84 -13 104 63 104 210 -73 141 47 32 141 -124 -95 -41 -75 -68 -58 1 42 12 186 -15 83 74 -25 -22 140 -30 -45 63 -61 -106 72 -26 -122 -25 -38 -98 57 -34 18 -38 31 -25 7 81 -9 -22 36 -57 47 35 19 -17 57 -184 113 -26 -40 64 -37 -14 -10 -33 69 -93 151 -41 1 56 -13 -15 25 -3 -22 -38 35 54 -35 69 -94 1 -50 -15 -28 -60 -45 -8 -8 5 54 6 66 -11 22 1 -40 41 24 14 88 56 -3 -64 31 37 -32 157 24 -106 -42 -82 -42 12 -7 -11 -12 42 -33 55 7 10 0 5 -68 46 -44 -51 -7 -68 4 -1 -39 -37 -98 -66 -63 8 77 -21 -67 75 -120 56 74 -3 78 -12 94 54 83 160 -53 104 37 27 133 -121 -96 -43 -80 -75 -66 1 47 13 185 -15 79 70 -25 -23 158 -37 -54 72 -68 -114 78 -30 -141 -30 -47 -125 74 -47 25 -53 40 -31 9 94 -10 -27 46 -76 62 47 25 -22 68 -219 131 -31 -49 83 -48 -19 -13 -46 99 -137 225 -62 1 80 -19 -21 35 -5 -34 -60 58 92 -63 125 -169 1 SS 20210322T100619.7Z 7751.421061 301 1 5.41 2 53.83 150.86 89.99 48.88 0.00 1 0.00 1 0 49 1.183e-03 7.485e-04 7.687e-04 4.094e-04 2.543677e-07 1.557957e-07 1.928483e-08 3.882915e-07 5.476953e-07 225.75 -2.00 3.80 -2.00 321.14 0.00e+00 2.208409e-04 5.300167e-05 1.036529e-05 1.078726e-04 1.413012e-04 270.65 -2.00 20.00 -2.00 320.82 0.00e+00 5.222783e-05 7.464731e-05 3.458385e-06 2.660083e-05 2.512595e-04 270.65 -2.00 20.00 -2.00 321.17 0.00e+00 1.376436e-04 9.925670e-05 1.859054e-05 1.628619e-05 2.551803e-04 270.65 -2.00 20.00 -2.00 321.03 0.00e+00 2.669802e-01 5.446672e-04 4.422123e-05 1.461211e-03 1.476793e-03 222.90 0.49 0.00 0.18 2.57 316.97 0.00e+00 6.318332e-05 2.558686e-05 8.911541e-06 1.812287e-05 3.617647e-05 270.65 -2.00 20.00 -2.00 316.15 0.00e+00 1.690 0.000 303.00 329.40 4 6.2171e-01 1.4357e-03 1.6264e-02 1.9872e-03 4.6138e-03 1.1714e-02 1.9137e-03 1.7086e-03 3.3689e-04 4.9718e-03 -1.2078e-03 1.0544e-03 1.3884e-04 1.7794e-04 2.7257e-03 1.4541e-04 4.6343e-04 6.5809e-05 3.9488e-05 1.0773e-03 2.5991e-04 3.2248e-04 3.5255e-05 6.8785e-05 7.2534e-04 4.4052e-02 -1.8172e-03 2.2876e-04 1.6910e-05 1.0429e-05 3.1052e-04 6.3322e-05 1.1777e-05 1.4154e-06 1.5338e-06 3.6125e-05 -1.8567e-02 1.0388e-05 -9.3553e-02 3.6218e-02 1.1424e-03 8.4773e-04 9.2318e-02 12 1 1 12 1 1 96.70 20.61 0.26 -0.01857 -0.01808 248 548 1 5 0 20.680 24.96 19.99 20.61 14.80 32.4 1008.36 38 -307 -150 -562 -103 -6 31 196 30 -253 -19 -128 53 96 -176 256 74 223 45 208 -83 -123 204 346 -77 361 -36 -246 36 -209 -94 -131 125 -107 -17 -132 69 131 137 -27 48 25 8 92 -126 -60 11 -112 -29 83 66 -45 -206 16 -74 -36 118 -22 -95 73 -183 65 76 -36 65 -87 73 68 99 8 -31 111 41 22 70 -136 -34 -34 -52 -114 -8 5 12 -36 138 25 21 81 -50 -46 56 52 -56 99 -64 -79 36 51 -71 17 -54 -72 65 -38 77 -58 -2 -26 55 130 78 -29 35 -87 8 39 51 -21 108 -183 98 -44 -24 14 -46 -4 -58 1 20 -102 134 -4 -21 -9 -9 -13 28 -4 -52 -64 59 59 -56 64 -42 19 6 -56 -29 -109 -20 -1 8 51 9 -77 -6 -42 18 33 -60 88 25 79 17 78 -30 -43 70 126 -28 140 -15 -97 13 -87 -41 -64 72 -65 -11 -86 45 85 89 -17 30 16 5 59 -81 -41 8 -79 -21 60 48 -32 -154 12 -57 -28 101 -19 -76 58 -141 51 64 -32 61 -82 67 61 80 6 -23 82 34 20 66 -133 -34 -35 -55 -127 -9 5 13 -39 143 23 20 80 -52 -51 63 63 -67 112 -71 -85 39 57 -81 20 -65 -91 84 -51 104 -79 -2 -32 65 150 93 -36 46 -114 10 51 64 -26 128 -215 113 -52 -30 18 -62 -6 -78 2 28 -147 197 -6 -31 -14 -12 -17 39 -6 -77 -100 95 100 -98 114 -75 34