File name: Pandora39s1_DearbornMI_20211120_L2Fit_fsus1c4d20210608p1-8.txt File generation date: 20250217T212239.2Z Data description: Level 2 spectral fitting results file Data file version: fsus1c4p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 39 Spectrometer number: 1 Processing software version used: BlickP v1.8.70 Instrument operation file used: Pandora39_OF_v3d20200924.txt Instrument calibration file used: Pandora39s1_CF_v4d20210608.txt Level 1 file used: Pandora39s1_DearbornMI_20211120_L1_smca1c4d20210608p1-8.txt Full location name: Dearborn MI - Salina Elementary School (AQS-26-163-0033) Short location name: DearbornMI Country of location: USA Location latitude [deg]: 42.3067 Location longitude [deg]: -83.1488 Location altitude [m]: 181 Local noon date: 20211120 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 267 412 Nominal wavelengths inside fitting window [nm]: 306.0837 306.2239 306.3642 306.5044 306.6446 306.7848 306.9250 307.0652 307.2054 307.3455 307.4857 307.6258 307.7659 307.9061 308.0462 308.1862 308.3263 308.4664 308.6064 308.7465 308.8865 309.0265 309.1665 309.3065 309.4465 309.5865 309.7264 309.8664 310.0063 310.1462 310.2861 310.4260 310.5659 310.7058 310.8456 310.9855 311.1253 311.2651 311.4049 311.5447 311.6845 311.8243 311.9641 312.1038 312.2435 312.3833 312.5230 312.6627 312.8024 312.9420 313.0817 313.2214 313.3610 313.5006 313.6402 313.7799 313.9194 314.0590 314.1986 314.3381 314.4777 314.6172 314.7567 314.8962 315.0357 315.1752 315.3147 315.4542 315.5936 315.7330 315.8725 316.0119 316.1513 316.2906 316.4300 316.5694 316.7087 316.8481 316.9874 317.1267 317.2660 317.4053 317.5445 317.6838 317.8231 317.9623 318.1015 318.2407 318.3799 318.5191 318.6583 318.7974 318.9366 319.0757 319.2149 319.3540 319.4931 319.6322 319.7712 319.9103 320.0494 320.1884 320.3274 320.4664 320.6054 320.7444 320.8834 321.0224 321.1613 321.3003 321.4392 321.5781 321.7170 321.8559 321.9948 322.1336 322.2725 322.4113 322.5501 322.6890 322.8278 322.9666 323.1053 323.2441 323.3828 323.5216 323.6603 323.7990 323.9377 324.0764 324.2151 324.3538 324.4924 324.6311 324.7697 324.9083 325.0469 325.1855 325.3241 325.4626 325.6012 325.7397 325.8782 326.0168 326.1553 326.2938 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20211120T142205.6Z 7994.598676 313 1 50.27 2 74.23 137.18 96.50 308.50 0.00 1 0.00 1 0 49 8.914e-02 5.891e-03 8.767e-02 5.168e-03 2.115330e-06 1.946080e-06 1.098365e-07 3.801267e-07 3.845154e-05 222.80 -2.00 3.54 -2.00 323.47 0.00e+00 6.609803e-04 8.258630e-04 5.570717e-05 2.691917e-05 1.039022e-02 277.80 -2.00 20.00 -2.00 324.03 0.00e+00 4.657142e-04 1.063161e-03 5.178073e-05 2.608616e-05 1.917445e-02 277.80 -2.00 20.00 -2.00 322.93 0.00e+00 2.479914e-03 2.362738e-03 3.937450e-04 1.603148e-05 1.956807e-02 277.80 -2.00 20.00 -2.00 323.28 0.00e+00 4.506651e-01 1.083671e-02 1.224411e-03 2.048236e-03 1.151163e-01 214.74 5.27 0.00 1.16 194.16 321.29 0.00e+00 -2.025034e-04 1.147094e-03 3.838593e-04 6.755985e-05 2.832052e-03 277.80 -2.00 20.00 -2.00 320.32 0.00e+00 3.616 0.001 303.00 329.40 4 4.5081e+00 1.9594e-02 3.4494e-02 2.0901e-03 3.5234e-01 -3.9884e-02 3.9701e-02 8.7540e-03 5.9365e-04 3.7974e-01 -1.4473e-02 2.2469e-02 2.6976e-03 3.2815e-04 2.0612e-01 3.5828e-02 1.7410e-02 3.5793e-04 2.6831e-04 7.1555e-02 -1.7248e-02 8.8457e-03 5.0147e-04 1.2593e-04 5.5223e-02 1.2490e-04 3.3399e-03 3.1742e-03 1.3331e-04 2.5357e-05 1.3956e-03 -6.0735e-05 1.8414e-04 7.7074e-06 1.5175e-06 2.7724e-03 2.3388e-03 2.6701e-05 -1.0552e-01 3.3828e-01 7.9017e-03 6.1425e-04 4.6812e+00 12 8 8 10 0 0 94.95 22.31 0.36 0.00234 0.00188 19 4 1 5 0 2645.430 26.32 20.00 22.31 10.14 9.1 900.18 -17566 16408 40371 -66223 -17822 -42145 15019 -3981 -7516 18386 -3680 10827 2440 2349 -438 12159 105 8707 -7799 -8692 -3021 -123 8892 -2941 4741 -3589 -1390 -11311 2367 10411 3642 1134 -137 6128 1140 5037 -369 858 173 3052 299 -1298 2951 -2018 -1419 3591 -372 216 2253 1776 585 -2101 -2776 511 1330 -1178 -2534 1918 730 563 -192 867 -1421 -1135 717 -644 -1201 -142 673 -795 -2855 3043 -438 -1308 -1656 2009 -951 33 -140 -302 -474 56 399 -266 935 -1047 1649 -1131 1184 232 -799 440 -172 461 -838 795 433 -16 1566 -252 253 -724 813 -120 150 -458 241 -339 -275 763 355 347 -694 -79 74 100 -605 311 -158 66 -129 -1042 350 -81 410 -185 246 -603 287 103 -117 -40 83 96 -275 349 28 -47 -15 -387 -149 344 324 -14 41 -217 -253 189 372 -1996 -368 -1325 323 -127 -271 570 -147 391 100 98 -19 482 5 422 -470 -531 -164 -6 426 -181 305 -282 -113 -973 177 810 358 139 -20 938 193 853 -67 153 31 540 55 -246 557 -435 -317 819 -95 57 606 492 164 -589 -776 143 401 -404 -964 720 265 197 -69 329 -633 -555 357 -324 -576 -62 264 -308 -1121 1215 -200 -695 -993 1270 -650 24 -108 -242 -392 46 314 -196 630 -683 1040 -795 923 207 -807 454 -178 469 -795 686 375 -15 1550 -265 282 -828 991 -160 209 -633 316 -417 -319 869 422 437 -934 -107 98 128 -758 367 -189 76 -148 -1256 461 -116 617 -289 399 -1047 500 186 -215 -73 149 165 -476 582 48 -81 -28 -802 -334 795 795 -36 106 -559 SS 20211120T145707.3Z 7994.623001 328 1 48.79 2 70.16 144.70 101.12 314.83 0.00 1 0.00 1 0 49 2.278e-02 2.701e-03 2.345e-02 2.883e-03 1.960794e-06 1.060726e-06 1.536465e-07 3.799631e-07 1.016101e-05 222.80 -2.00 3.54 -2.00 322.99 0.00e+00 -6.055504e-05 4.324114e-04 7.901142e-05 2.677902e-05 2.661950e-03 277.79 -2.00 20.00 -2.00 323.34 0.00e+00 -3.511163e-05 5.554337e-04 2.365055e-05 2.614181e-05 4.929268e-03 277.79 -2.00 20.00 -2.00 322.54 0.00e+00 2.723943e-04 1.112856e-03 6.395850e-05 1.603679e-05 5.002778e-03 277.79 -2.00 20.00 -2.00 322.81 0.00e+00 3.820064e-01 5.452144e-03 2.826404e-04 2.048985e-03 2.930934e-02 222.11 3.22 0.00 1.35 49.69 320.42 0.00e+00 5.619969e-04 4.698098e-04 2.023501e-05 6.755738e-05 7.676654e-04 277.79 -2.00 20.00 -2.00 319.40 0.00e+00 2.914 0.000 303.00 329.40 4 4.3014e+00 1.0917e-02 2.7704e-02 2.0891e-03 9.0295e-02 -1.4020e-02 2.0300e-02 3.3085e-03 5.9083e-04 9.7075e-02 7.0346e-03 1.0779e-02 9.2059e-04 3.0982e-04 5.2515e-02 -4.7370e-03 7.0674e-03 1.5499e-03 1.9315e-04 2.1160e-02 1.7161e-04 3.9268e-03 2.2274e-04 1.0006e-04 1.6298e-02 3.1802e-04 -2.2167e-03 1.6760e-03 2.2378e-04 3.1219e-05 1.9406e-03 -4.0110e-04 9.5697e-05 6.0957e-06 1.5785e-06 7.0385e-04 2.7794e-03 -4.9687e-05 -5.1726e-01 2.1312e-01 5.4869e-04 4.0566e-04 1.3927e+00 12 8 8 10 0 0 99.36 22.31 0.09 0.00278 -0.00028 38 8 1 5 0 1283.690 26.32 20.00 22.31 9.67 9.0 897.06 -13865 3434 -1598 9828 -9181 1735 2740 3055 -1880 -253 5455 -6205 4454 -1739 2087 834 5226 554 262 1185 740 772 -7208 -3206 -4897 1676 -3112 2624 3251 2183 -761 218 675 -40 886 -710 -582 -1566 51 -108 1197 76 -389 593 -1882 1063 546 326 -447 150 900 510 -421 -637 215 -409 628 -718 389 632 113 -118 -330 247 -161 147 -701 677 383 -549 -304 -589 -56 100 358 -260 331 36 123 -85 41 95 -90 383 -153 317 -147 -921 -161 -82 -76 255 256 -217 -324 30 -196 250 -516 253 -128 98 422 12 -353 -137 160 -43 31 -19 340 -181 94 121 191 -491 326 -169 -132 195 9 376 171 198 -51 -156 -150 -16 32 -133 96 94 -104 -116 150 -93 -29 164 -22 -43 -108 -10 -34 -139 35 187 -428 104 -51 302 -350 70 129 166 -120 -17 365 -468 327 -133 160 67 420 49 24 109 68 68 -701 -319 -551 195 -398 302 372 283 -119 40 146 -10 220 -186 -154 -418 13 -29 310 20 -106 172 -608 355 195 122 -173 59 351 195 -162 -253 92 -185 305 -361 183 292 53 -57 -181 148 -100 92 -418 369 196 -261 -141 -292 -31 62 248 -197 261 29 106 -77 38 89 -81 330 -122 236 -108 -727 -141 -78 -81 290 291 -234 -322 28 -181 251 -558 283 -152 118 545 17 -510 -195 214 -53 38 -23 422 -232 127 168 260 -654 416 -213 -159 225 10 464 223 276 -75 -237 -237 -25 54 -234 171 170 -185 -196 244 -148 -46 279 -40 -83 -221 -21 -80 -321 81 430 SS 20211120T151127.7Z 7994.632960 338 1 36.63 2 68.69 147.94 102.87 317.54 0.00 1 0.00 1 0 49 8.611e-03 1.912e-03 1.391e-02 2.325e-03 9.246524e-07 8.479226e-07 3.230574e-08 3.798830e-07 3.893765e-06 222.80 -2.00 3.54 -2.00 322.65 0.00e+00 3.272235e-05 3.359666e-04 1.572879e-05 2.664279e-05 1.009479e-03 277.79 -2.00 20.00 -2.00 322.81 0.00e+00 -2.595959e-04 4.369310e-04 4.458329e-06 2.619944e-05 1.869608e-03 277.79 -2.00 20.00 -2.00 322.27 0.00e+00 -3.558352e-04 8.097219e-04 8.711510e-06 1.615313e-05 1.890364e-03 277.79 -2.00 20.00 -2.00 322.47 0.00e+00 3.598237e-01 4.042634e-03 2.524851e-05 2.049370e-03 1.107252e-02 220.43 2.55 0.00 1.43 18.90 319.80 0.00e+00 -7.626894e-06 3.124265e-04 2.918861e-06 6.776397e-05 2.841806e-04 277.79 -2.00 20.00 -2.00 318.78 0.00e+00 2.726 0.000 303.00 329.40 4 4.1616e+00 8.4668e-03 2.5912e-02 2.0868e-03 3.4161e-02 -1.2506e-02 1.4730e-02 2.6867e-03 5.9061e-04 3.6795e-02 3.0531e-03 7.8892e-03 2.3164e-04 2.9845e-04 1.9862e-02 -1.6926e-03 4.8535e-03 2.5290e-04 1.5012e-04 8.0872e-03 1.8199e-04 2.8059e-03 1.7104e-05 8.8815e-05 6.1311e-03 4.5213e-04 -1.4567e-03 1.3443e-03 4.0033e-05 2.7646e-05 9.0354e-04 -5.1176e-04 7.4426e-05 2.3408e-06 1.6060e-06 2.6577e-04 3.2956e-03 -7.2562e-05 -1.9792e-01 1.7601e-01 2.9134e-04 4.4271e-04 5.4733e-01 12 9 9 12 1 1 99.96 22.31 0.34 0.00330 -0.00061 25 8 1 5 0 1402.130 26.32 20.00 22.31 9.66 9.0 897.13 -2780 1832 -2600 4417 1698 1809 1146 -1482 509 2140 2384 1719 -1004 1669 -899 1313 -663 994 1660 -1329 -2223 876 -1378 -796 -189 -1329 -316 -1793 -840 -4 -1279 -491 -712 312 623 144 66 320 -303 33 239 -705 -773 262 266 -89 689 -19 37 209 -325 314 -283 369 -714 499 -227 710 -250 594 14 -230 299 124 181 -157 283 -492 -72 -438 -713 519 -245 122 139 -28 -184 35 -22 -52 -104 -134 -143 208 297 254 -139 -96 296 43 54 221 -355 -21 -67 177 -348 -49 124 -13 184 -63 73 -101 -218 48 -38 -156 -108 167 319 155 -185 27 -213 -62 170 -28 387 -80 137 -92 -170 -64 218 -128 -2 -89 146 70 -165 10 17 42 18 -2 107 -7 -107 88 -32 -179 1 83 168 -123 -110 77 -120 194 82 102 76 -116 44 191 224 170 -106 174 -96 143 -80 124 214 -177 -281 102 -168 -106 -28 -215 -53 -290 -135 -1 -249 -114 -194 92 191 46 21 103 -98 11 76 -227 -255 91 100 -36 293 -8 17 97 -152 143 -128 172 -364 275 -126 397 -143 320 7 -133 182 83 126 -109 186 -303 -43 -240 -382 291 -147 84 105 -24 -160 32 -20 -50 -103 -132 -136 196 258 206 -111 -82 280 43 60 262 -421 -23 -69 169 -337 -51 138 -15 227 -78 96 -142 -315 68 -51 -194 -134 205 406 196 -250 37 -291 -82 217 -36 476 -96 161 -117 -220 -88 316 -191 -3 -137 238 117 -281 17 28 69 28 -3 175 -12 -190 161 -64 -380 2 178 367 -267 SS 20211120T154546.0Z 7994.656783 354 1 48.88 2 65.71 156.07 106.66 324.35 0.00 1 0.00 1 0 49 7.972e-03 1.677e-03 7.197e-03 1.548e-03 1.011577e-06 5.678417e-07 6.300756e-08 3.798102e-07 3.632943e-06 222.80 -2.00 3.54 -2.00 322.42 0.00e+00 1.588696e-04 2.211796e-04 3.523655e-05 2.655849e-05 9.421313e-04 277.79 -2.00 20.00 -2.00 322.49 0.00e+00 3.460180e-04 2.877689e-04 1.133499e-05 2.620152e-05 1.721373e-03 277.79 -2.00 20.00 -2.00 322.10 0.00e+00 2.759585e-04 5.045491e-04 2.777770e-05 1.657650e-05 1.750701e-03 277.79 -2.00 20.00 -2.00 322.27 0.00e+00 3.222318e-01 2.570470e-03 4.682306e-05 2.049613e-03 1.021108e-02 223.02 1.84 0.00 1.60 17.53 319.41 0.00e+00 2.604950e-04 1.849404e-04 1.110950e-05 6.784844e-05 2.584027e-04 277.79 -2.00 20.00 -2.00 318.39 0.00e+00 2.415 0.000 303.00 329.40 4 3.9322e+00 5.6980e-03 2.2953e-02 2.0851e-03 3.1586e-02 -1.0041e-02 9.4236e-03 2.3954e-03 5.8434e-04 3.4086e-02 -1.8991e-04 5.0393e-03 4.9939e-04 2.8589e-04 1.8432e-02 2.2606e-03 2.7950e-03 5.3628e-04 1.1968e-04 7.4039e-03 -1.9090e-03 1.6668e-03 2.7353e-05 8.2733e-05 5.3655e-03 7.8128e-04 -3.2813e-04 1.0270e-03 9.7869e-05 2.8325e-05 1.1438e-03 -4.3032e-04 4.8774e-05 3.4942e-06 1.6322e-06 2.4625e-04 2.8217e-03 -6.1837e-05 -4.9137e-02 1.2643e-01 4.7101e-04 4.8658e-04 5.4021e-01 12 8 8 10 0 0 99.72 22.31 0.28 0.00282 -0.00046 57 13 1 5 0 857.340 26.32 20.00 22.31 10.28 9.1 900.86 4138 -3428 407 1031 -1320 3238 -1924 2884 753 805 901 1265 -986 -272 171 -329 1096 1408 -1390 637 -1931 1681 -239 -67 470 -355 -1786 -435 -1014 -141 -1115 -149 -866 -239 183 -196 479 340 524 -767 285 -541 21 93 -164 274 -361 497 -84 245 93 353 -70 -6 -243 -82 183 -171 583 -227 170 21 52 402 8 -100 -182 167 166 105 -412 -104 -190 -99 523 -232 6 -186 60 -247 123 33 -70 -35 121 316 -482 260 -190 80 16 239 101 -46 -245 -131 101 -287 146 -224 29 46 170 34 -117 -110 -46 65 -221 334 56 104 -198 -16 178 -57 118 -213 179 -35 45 -23 61 96 -101 -32 -76 6 -46 -20 -43 124 81 -63 7 5 82 -55 -3 -103 69 -1 -4 48 -69 17 208 -205 25 63 -87 237 -172 281 83 93 109 159 -131 -36 23 -46 160 217 -228 102 -298 236 -35 -11 80 -67 -355 -81 -189 -29 -271 -43 -270 -81 64 -71 175 124 191 -280 101 -193 8 36 -68 120 -168 238 -41 123 46 172 -34 -3 -132 -48 116 -110 347 -128 96 12 35 296 6 -77 -134 114 102 59 -226 -60 -125 -74 398 -192 5 -171 59 -255 130 35 -72 -33 105 255 -409 215 -177 83 18 274 116 -53 -263 -131 102 -316 171 -256 35 58 228 49 -172 -158 -62 81 -260 412 68 132 -271 -23 247 -77 153 -263 226 -42 53 -28 79 132 -145 -47 -117 9 -74 -33 -72 211 134 -102 11 7 125 -89 -5 -184 133 -1 -8 100 -146 36 SS 20211120T155115.7Z 7994.660598 357 1 44.98 2 65.31 157.42 107.22 325.48 0.00 1 0.00 1 0 49 1.784e-02 3.178e-03 1.536e-02 3.291e-03 -3.046961e-07 1.209958e-06 1.845223e-07 3.797854e-07 8.122958e-06 222.80 -2.00 3.54 -2.00 322.49 0.00e+00 4.432232e-04 4.706114e-04 1.110167e-04 2.655263e-05 2.113521e-03 277.79 -2.00 20.00 -2.00 322.63 0.00e+00 1.332336e-03 6.172512e-04 3.221475e-05 2.620970e-05 3.855855e-03 277.79 -2.00 20.00 -2.00 322.15 0.00e+00 -7.447103e-04 1.080606e-03 2.052899e-05 1.657842e-05 3.918524e-03 277.79 -2.00 20.00 -2.00 322.33 0.00e+00 3.219304e-01 5.513091e-03 1.716198e-04 2.049630e-03 2.280803e-02 222.43 3.94 0.00 1.59 39.30 319.44 0.00e+00 1.048862e-03 3.924357e-04 4.542668e-05 6.781625e-05 5.735508e-04 277.79 -2.00 20.00 -2.00 318.40 0.00e+00 2.378 0.000 303.00 329.40 4 5.1753e+00 1.2128e-02 2.2614e-02 2.0849e-03 7.0564e-02 2.1747e-02 2.0102e-02 2.4097e-03 5.8772e-04 7.6220e-02 -1.4411e-02 1.0728e-02 1.6090e-03 2.8815e-04 4.1223e-02 2.8296e-03 5.8039e-03 1.6755e-03 1.1712e-04 1.6045e-02 1.8235e-03 3.4968e-03 7.3150e-05 8.1070e-05 1.1637e-02 2.3281e-04 2.9180e-05 2.2679e-03 3.0150e-04 2.8943e-05 2.4195e-03 -6.3065e-04 1.0468e-04 9.9554e-06 1.6491e-06 5.5228e-04 2.8298e-03 -6.1856e-05 2.1968e-01 2.7392e-01 1.9482e-03 4.4836e-04 1.1976e+00 12 9 9 12 1 1 99.73 22.31 0.35 0.00283 -0.00198 12 3 1 5 0 3446.730 26.32 20.00 22.31 10.31 9.1 901.32 4947 8101 -10588 -2682 -2936 6025 -5633 -2341 605 5167 -1690 -1224 563 -161 -141 43 -2559 -1582 2902 480 845 1921 -844 5785 -1597 2057 -1024 -1740 302 -105 -1061 -1004 1084 -112 1682 -561 547 -214 385 -445 635 491 -362 -325 -2397 1904 -127 488 -458 -449 708 -480 -134 -866 45 -68 6 -435 716 -211 919 -54 -350 320 -52 245 329 97 -456 36 -773 709 215 231 236 -50 -39 -377 -400 -24 17 214 -198 -100 324 -443 -512 -160 -22 125 188 105 132 -435 54 22 60 -144 430 -388 -124 174 -74 756 -376 176 -277 235 71 73 108 -122 217 -118 14 94 -32 -76 -27 430 -63 -316 -119 71 -262 -31 -59 -90 159 -80 -58 24 -76 -14 258 -120 256 -256 -103 -76 163 264 -172 -137 79 30 245 429 -712 -168 -196 428 -523 -241 67 575 -211 -158 74 -22 -19 6 -385 -247 448 76 125 267 -122 852 -277 374 -200 -325 55 -21 -254 -275 338 -39 592 -209 204 -80 144 -165 229 177 -133 -127 -1032 830 -60 237 -228 -228 354 -238 -66 -443 25 -39 3 -270 428 -120 513 -32 -228 227 -38 180 231 64 -282 20 -423 402 140 163 185 -43 -33 -343 -390 -25 17 223 -200 -94 288 -368 -413 -136 -20 127 211 122 153 -494 57 22 60 -155 491 -449 -151 222 -100 1043 -539 245 -378 296 84 85 131 -157 297 -161 19 128 -42 -94 -34 506 -74 -378 -154 98 -365 -44 -86 -139 251 -131 -96 41 -127 -22 410 -187 400 -411 -179 -139 320 535 -366 -298 173 64 SS 20211120T160138.7Z 7994.667809 362 1 48.87 2 64.62 160.01 108.22 327.65 0.00 1 0.00 1 0 49 1.493e-02 2.898e-03 9.850e-03 2.208e-03 1.299852e-06 8.085053e-07 6.888882e-08 3.797984e-07 6.774120e-06 222.80 -2.00 3.54 -2.00 322.46 0.00e+00 3.102732e-04 3.155174e-04 4.026596e-05 2.654461e-05 1.766269e-03 277.79 -2.00 20.00 -2.00 322.58 0.00e+00 -4.805936e-04 4.150196e-04 2.120814e-05 2.622658e-05 3.207696e-03 277.79 -2.00 20.00 -2.00 322.13 0.00e+00 1.321204e-03 7.208484e-04 9.975795e-05 1.664570e-05 3.279621e-03 277.79 -2.00 20.00 -2.00 322.30 0.00e+00 3.068988e-01 3.660448e-03 1.990501e-04 2.049678e-03 1.909440e-02 221.45 2.74 0.00 1.68 32.69 319.38 0.00e+00 2.278149e-04 2.588485e-04 1.688129e-05 6.788756e-05 4.856516e-04 277.79 -2.00 20.00 -2.00 318.34 0.00e+00 2.318 0.000 303.00 329.40 4 4.6272e+00 8.0602e-03 2.2058e-02 2.0855e-03 5.9097e-02 -1.7168e-02 1.3293e-02 2.5368e-03 5.8948e-04 6.3750e-02 7.4459e-03 7.1378e-03 6.1774e-04 2.8940e-04 3.4547e-02 1.8433e-04 3.8618e-03 4.8781e-04 1.1694e-04 1.3834e-02 -4.3841e-03 2.3279e-03 9.8952e-05 8.1344e-05 9.8589e-03 4.3016e-04 2.4509e-04 1.5734e-03 1.1001e-04 3.0065e-05 2.4357e-03 -3.3891e-04 7.0349e-05 3.3057e-06 1.6616e-06 4.6190e-04 2.3413e-03 -3.0065e-05 -1.3670e-01 1.8733e-01 2.8283e-03 4.1329e-04 1.0426e+00 12 8 8 10 0 0 99.80 22.31 0.30 0.00234 -0.00024 34 8 1 5 0 1437.100 26.32 20.00 22.31 10.80 9.1 905.06 -2646 3782 -8131 7224 -4045 5786 -49 1416 2590 -685 997 -1207 4106 -3365 3284 -1065 2030 162 1886 -557 -1235 653 -2933 714 -2752 22 -1396 -304 -873 -407 904 -966 392 -1200 1295 -903 343 743 -72 720 -443 327 -1783 406 -465 480 95 567 71 -231 278 -931 869 -1018 494 -519 158 47 332 245 -783 693 -651 496 118 -20 -11 18 281 2 158 -428 592 -113 907 -182 171 -236 -205 -28 -84 538 -368 209 24 209 -696 -232 24 -162 210 -273 372 -275 22 -335 266 -166 39 -311 -115 132 -75 319 -50 -37 -178 228 -62 -2 256 -288 -77 -66 270 -211 289 113 -35 142 69 -2 -221 -56 -177 56 161 -46 191 -100 297 -129 -5 -254 -28 -240 331 130 -83 28 -23 74 -131 104 -193 130 -151 223 -569 435 -289 433 -4 146 292 -83 125 -160 534 -479 436 -153 302 26 307 -92 -193 95 -443 113 -490 4 -278 -57 -163 -85 216 -281 125 -426 467 -343 130 279 -27 267 -163 119 -670 159 -197 213 45 277 35 -118 141 -468 428 -527 271 -313 97 29 200 139 -445 410 -426 351 87 -15 -8 12 173 1 86 -246 384 -80 706 -155 152 -215 -199 -29 -88 560 -372 195 21 173 -561 -197 22 -164 234 -316 426 -310 23 -328 261 -178 44 -372 -139 167 -101 440 -70 -52 -241 284 -76 -2 318 -368 -105 -93 373 -285 375 139 -43 166 79 -3 -284 -76 -252 82 233 -70 309 -163 487 -216 -8 -416 -45 -371 513 214 -143 50 -45 149 -277 224 -420 279