File name: Pandora103s1_Downsview_20210114_L2Fit_fnvs4c10d20181123p1-8.txt File generation date: 20241101T115323.4Z Data description: Level 2 spectral fitting results file Data file version: fnvs4c10p1-8 Local principal investigator: Vitali Fioletov Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 103 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora103_OF_v10d20171016.txt Instrument calibration file used: Pandora103s1_CF_v10d20200901.txt Level 1 file used: Pandora103s1_Downsview_20210114_L1_smca1c10d20181123p1-8.txt Full location name: Environment Canada HQ - Downsview Short location name: Downsview Country of location: Canada Location latitude [deg]: 43.7810 Location longitude [deg]: -79.4680 Location altitude [m]: 187 Local noon date: 20210114 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method) Data caveats: FieldAna 3rd VP - WinterReference but for LabData 2017 but L7 from 2023 First and last pixel inside fitting window: 896 1440 Nominal wavelengths inside fitting window [nm]: 400.1239 400.2562 400.3884 400.5206 400.6529 400.7851 400.9173 401.0494 401.1816 401.3138 401.4459 401.5780 401.7101 401.8422 401.9743 402.1064 402.2384 402.3705 402.5025 402.6345 402.7665 402.8985 403.0305 403.1624 403.2944 403.4263 403.5582 403.6901 403.8220 403.9539 404.0857 404.2176 404.3494 404.4812 404.6130 404.7448 404.8766 405.0084 405.1401 405.2718 405.4036 405.5353 405.6670 405.7986 405.9303 406.0620 406.1936 406.3252 406.4568 406.5884 406.7200 406.8516 406.9831 407.1146 407.2462 407.3777 407.5092 407.6406 407.7721 407.9036 408.0350 408.1664 408.2978 408.4292 408.5606 408.6920 408.8233 408.9547 409.0860 409.2173 409.3486 409.4799 409.6112 409.7424 409.8737 410.0049 410.1361 410.2673 410.3985 410.5296 410.6608 410.7919 410.9231 411.0542 411.1853 411.3164 411.4474 411.5785 411.7095 411.8406 411.9716 412.1026 412.2336 412.3645 412.4955 412.6264 412.7574 412.8883 413.0192 413.1501 413.2809 413.4118 413.5426 413.6735 413.8043 413.9351 414.0659 414.1966 414.3274 414.4581 414.5888 414.7196 414.8503 414.9809 415.1116 415.2423 415.3729 415.5035 415.6342 415.7648 415.8953 416.0259 416.1565 416.2870 416.4175 416.5481 416.6785 416.8090 416.9395 417.0700 417.2004 417.3308 417.4612 417.5916 417.7220 417.8524 417.9827 418.1131 418.2434 418.3737 418.5040 418.6343 418.7646 418.8948 419.0251 419.1553 419.2855 419.4157 419.5459 419.6760 419.8062 419.9363 420.0665 420.1966 420.3267 420.4567 420.5868 420.7169 420.8469 420.9769 421.1069 421.2369 421.3669 421.4969 421.6268 421.7568 421.8867 422.0166 422.1465 422.2763 422.4062 422.5361 422.6659 422.7957 422.9255 423.0553 423.1851 423.3148 423.4446 423.5743 423.7040 423.8337 423.9634 424.0931 424.2228 424.3524 424.4820 424.6117 424.7413 424.8708 425.0004 425.1300 425.2595 425.3890 425.5186 425.6481 425.7775 425.9070 426.0365 426.1659 426.2953 426.4247 426.5541 426.6835 426.8129 426.9422 427.0716 427.2009 427.3302 427.4595 427.5888 427.7180 427.8473 427.9765 428.1057 428.2350 428.3641 428.4933 428.6225 428.7516 428.8808 429.0099 429.1390 429.2681 429.3971 429.5262 429.6552 429.7843 429.9133 430.0423 430.1713 430.3002 430.4292 430.5581 430.6871 430.8160 430.9449 431.0738 431.2026 431.3315 431.4603 431.5891 431.7179 431.8467 431.9755 432.1043 432.2330 432.3618 432.4905 432.6192 432.7479 432.8765 433.0052 433.1339 433.2625 433.3911 433.5197 433.6483 433.7769 433.9054 434.0340 434.1625 434.2910 434.4195 434.5480 434.6764 434.8049 434.9333 435.0618 435.1902 435.3186 435.4469 435.5753 435.7036 435.8320 435.9603 436.0886 436.2169 436.3452 436.4734 436.6017 436.7299 436.8581 436.9863 437.1145 437.2427 437.3708 437.4990 437.6271 437.7552 437.8833 438.0114 438.1394 438.2675 438.3955 438.5235 438.6515 438.7795 438.9075 439.0355 439.1634 439.2913 439.4193 439.5472 439.6750 439.8029 439.9308 440.0586 440.1864 440.3142 440.4420 440.5698 440.6976 440.8253 440.9531 441.0808 441.2085 441.3362 441.4639 441.5915 441.7192 441.8468 441.9744 442.1020 442.2296 442.3572 442.4847 442.6122 442.7398 442.8673 442.9948 443.1223 443.2497 443.3772 443.5046 443.6320 443.7594 443.8868 444.0142 444.1415 444.2689 444.3962 444.5235 444.6508 444.7781 444.9054 445.0326 445.1599 445.2871 445.4143 445.5415 445.6687 445.7958 445.9230 446.0501 446.1772 446.3043 446.4314 446.5585 446.6855 446.8126 446.9396 447.0666 447.1936 447.3206 447.4475 447.5745 447.7014 447.8283 447.9552 448.0821 448.2090 448.3358 448.4627 448.5895 448.7163 448.8431 448.9699 449.0967 449.2234 449.3502 449.4769 449.6036 449.7303 449.8569 449.9836 450.1102 450.2369 450.3635 450.4901 450.6167 450.7432 450.8698 450.9963 451.1228 451.2493 451.3758 451.5023 451.6288 451.7552 451.8816 452.0080 452.1344 452.2608 452.3872 452.5135 452.6399 452.7662 452.8925 453.0188 453.1451 453.2713 453.3976 453.5238 453.6500 453.7762 453.9024 454.0286 454.1547 454.2808 454.4070 454.5331 454.6592 454.7852 454.9113 455.0373 455.1634 455.2894 455.4154 455.5413 455.6673 455.7933 455.9192 456.0451 456.1710 456.2969 456.4228 456.5486 456.6745 456.8003 456.9261 457.0519 457.1777 457.3034 457.4292 457.5549 457.6806 457.8063 457.9320 458.0577 458.1834 458.3090 458.4346 458.5602 458.6858 458.8114 458.9369 459.0625 459.1880 459.3135 459.4390 459.5645 459.6900 459.8154 459.9409 460.0663 460.1917 460.3171 460.4425 460.5678 460.6932 460.8185 460.9438 461.0691 461.1944 461.3196 461.4449 461.5701 461.6953 461.8205 461.9457 462.0709 462.1960 462.3212 462.4463 462.5714 462.6965 462.8216 462.9466 463.0717 463.1967 463.3217 463.4467 463.5717 463.6966 463.8216 463.9465 464.0714 464.1963 464.3212 464.4461 464.5710 464.6958 464.8206 464.9454 465.0702 465.1950 465.3197 465.4445 465.5692 465.6939 465.8186 465.9433 466.0680 466.1926 466.3172 466.4419 466.5665 466.6910 466.8156 466.9402 467.0647 467.1892 467.3137 467.4382 467.5627 467.6871 467.8116 467.9360 468.0604 468.1848 468.3092 468.4336 468.5579 468.6822 468.8065 468.9308 469.0551 469.1794 469.3036 469.4279 469.5521 469.6763 469.8005 469.9246 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Columns 161-705: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 706-1250: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20210114T164733.2Z 7684.699690 159 1 52.36 2 65.59 169.87 71.30 149.55 0.00 1 0.00 1 0 17 1.206e-03 1.172e-03 1.042e-03 1.016e-03 4.483585e+02 1.829581e+02 1.154581e+02 6.749224e+02 2.292450e+02 271.85 -2.00 20.00 -2.00 445.58 0.00e+00 4.662198e-04 1.122807e-04 2.386936e-05 2.818336e-05 1.316091e-04 271.85 -2.00 20.00 -2.00 454.79 0.00e+00 5.480389e-04 1.036740e-05 4.118816e-05 1.515141e-05 1.251424e-05 271.85 -2.00 20.00 -2.00 436.18 0.00e+00 -2.153255e+05 1.376274e+05 5.497637e+04 4.307075e+05 1.721267e+05 254.67 -2.00 11.30 -2.00 457.01 0.00e+00 3.861321e-01 2.843737e-02 1.132126e-02 1.833505e-02 3.747898e-02 223.37 -2.00 3.57 -2.00 454.16 0.00e+00 -5.354225e-06 3.519709e-06 1.109312e-06 2.153542e-06 4.553236e-06 271.85 -2.00 20.00 -2.00 455.31 0.00e+00 2.403 0.000 397.00 473.00 4 7.8479e+00 1.1011e-03 6.2232e-03 7.3507e-04 1.2531e-03 6.0934e-02 1.2852e-03 1.2442e-03 4.3982e-04 1.5122e-03 -1.6932e-02 7.5213e-04 1.6514e-04 1.8541e-04 8.7994e-04 1.5364e-04 2.4713e-04 4.5777e-05 4.5717e-05 2.9055e-04 1.4191e-03 1.2839e-04 2.9831e-05 2.6880e-05 1.4723e-04 3.9880e-04 -3.5728e-03 7.3842e-04 1.7921e-04 8.1672e-05 7.7704e-04 -4.3747e-05 9.9751e-06 1.5381e-07 5.6384e-07 1.1685e-05 1.4754e-05 1.3972e-05 5.6964e-07 6.8203e-07 1.6140e-05 4.7077e-04 -7.3705e-06 6.5706e-01 1.0046e-01 1.1556e-02 4.2552e-03 1.1094e-01 11 8 0 10 0 0 83.60 15.00 0.54 0.00047 -0.00174 14 3 1 4 0 3739.230 21.88 15.00 18.76 89 379 -335 60 -206 18 -112 4 -47 -62 2 -128 -59 199 -15 167 -148 -78 -32 -159 133 -103 -27 -1 42 -112 86 190 40 49 8 107 207 -55 115 -168 -130 -82 -50 228 260 -134 -9 172 55 94 -79 164 33 27 41 5 -103 105 53 -32 -46 83 126 96 -51 -14 -57 -41 134 152 106 -85 64 -31 -43 94 -7 -17 -157 -180 -207 -348 -121 -88 176 263 -5 -10 -43 120 6 144 -91 -41 97 -125 120 -82 -48 -45 -59 179 -159 -148 -162 -65 0 198 121 -116 161 -234 -53 126 -170 -174 -56 -61 -137 -107 -17 -46 -208 -366 -16 -42 -21 41 -119 -90 -32 33 43 27 -71 -83 -43 -134 -170 -24 -33 -151 -144 43 -61 206 -40 -30 -221 185 194 -60 46 -214 -79 -120 10 -88 190 -86 131 139 -36 143 234 77 225 46 128 245 359 -97 15 -19 -278 -191 209 -34 -37 180 30 222 195 136 -48 -22 157 -29 -102 25 -4 -10 -102 91 65 -106 -136 -2 2 37 -102 -20 53 -64 -51 -117 21 133 18 -228 -6 -77 -7 -26 31 -226 18 123 2 61 -19 -87 104 159 -1 -112 154 67 -40 -12 110 70 -74 411 55 297 -147 359 55 -91 271 20 -3 169 17 171 214 179 66 -160 40 147 184 41 43 60 98 197 153 -62 -3 86 68 271 -111 -2 -186 -109 -157 -119 18 -20 -149 72 30 -15 -17 75 152 -121 -324 46 -33 -5 75 82 -127 -164 -64 -16 -13 -57 193 14 -89 24 -282 -66 -73 -111 -107 -162 147 2 -60 1 -173 -31 -468 59 44 -4 32 -155 -2 -87 -242 -13 105 -60 -101 -69 35 117 72 -110 -102 -72 -73 -49 38 -26 75 127 33 -62 23 -123 -82 -91 -236 96 -77 -90 10 50 17 95 109 1 -94 24 -134 61 223 -6 -21 32 68 82 -15 138 -5 -61 -23 93 50 39 -62 172 35 56 -68 -26 -13 120 96 -109 -53 95 79 14 -12 60 -25 -24 -163 68 -143 -84 -18 52 179 -80 -2 -38 -17 95 99 5 -143 81 22 -5 -81 28 -34 314 -70 40 65 -260 33 -41 -33 77 -250 2 -216 28 -89 241 124 45 86 -263 28 -44 -88 -144 -25 -127 -109 -139 57 164 104 -19 94 61 119 10 -127 46 -52 -67 42 165 29 -73 33 7 23 -34 -59 -31 -97 38 116 -20 -29 97 204 -101 132 70 -180 -56 2 -31 174 -82 -13 -40 61 30 181 -72 82 -75 -58 50 67 130 145 -98 -10 360 50 -93 -68 -138 -29 -6 -25 -29 -81 -132 -106 -133 54 7 -104 165 140 -131 -43 -96 133 -204 115 -87 142 47 19 35 -39 -74 170 -81 -29 150 -41 189 126 -142 128 13 134 -94 -51 -136 155 -68 -82 -38 4 36 -47 -27 -25 56 -121 168 -36 100 -109 -203 8 73 306 -265 47 -160 14 -91 3 -39 -53 2 -107 -49 167 -13 142 -127 -66 -27 -138 115 -87 -22 -1 33 -90 72 165 35 44 7 92 167 -43 89 -135 -111 -72 -44 197 220 -112 -8 143 46 78 -65 132 26 22 35 4 -88 89 45 -27 -39 69 104 82 -45 -13 -51 -37 120 139 99 -80 60 -29 -39 84 -7 -14 -129 -142 -160 -272 -99 -76 157 238 -4 -9 -40 113 6 139 -87 -39 91 -118 113 -78 -45 -42 -55 167 -146 -133 -146 -59 0 190 119 -115 155 -218 -48 116 -160 -167 -54 -58 -130 -101 -16 -42 -193 -347 -15 -41 -21 41 -119 -89 -31 32 41 26 -65 -75 -40 -124 -159 -23 -31 -143 -136 41 -57 191 -37 -28 -212 181 190 -59 44 -198 -71 -108 9 -81 178 -82 129 139 -36 143 235 77 223 45 123 237 355 -98 15 -18 -252 -163 176 -30 -35 177 30 216 185 128 -45 -20 149 -28 -100 24 -4 -10 -97 84 60 -99 -128 -2 2 36 -97 -19 49 -59 -49 -117 21 132 17 -208 -5 -66 -6 -23 29 -216 18 118 2 58 -18 -81 96 142 -1 -100 138 61 -37 -11 95 57 -58 309 41 226 -113 271 40 -66 195 15 -3 147 16 171 222 189 69 -162 38 131 158 36 40 59 100 202 157 -64 -3 83 61 227 -92 -1 -167 -104 -154 -120 19 -20 -145 69 28 -14 -17 75 153 -123 -332 48 -35 -5 78 84 -129 -166 -65 -16 -12 -55 189 14 -91 24 -265 -59 -63 -97 -98 -154 141 2 -58 1 -172 -31 -475 59 44 -4 31 -148 -2 -82 -232 -13 107 -63 -107 -71 36 117 73 -116 -108 -76 -76 -51 40 -27 78 132 34 -64 23 -123 -83 -93 -246 101 -81 -92 11 51 18 100 116 1 -100 25 -137 61 218 -6 -21 31 67 81 -15 142 -6 -64 -24 96 52 41 -67 186 38 61 -73 -27 -13 123 100 -117 -57 103 84 15 -13 64 -26 -25 -174 73 -155 -91 -19 57 200 -90 -2 -43 -19 107 111 6 -158 88 24 -5 -90 31 -37 344 -75 42 67 -267 33 -42 -35 80 -260 2 -232 30 -98 267 137 50 95 -287 30 -47 -94 -154 -26 -137 -117 -151 63 182 117 -22 106 68 131 11 -141 52 -59 -75 48 186 33 -83 37 8 25 -37 -64 -34 -106 41 128 -22 -33 108 228 -112 146 77 -200 -62 2 -35 194 -91 -14 -45 70 35 209 -83 94 -86 -66 57 77 149 167 -113 -12 417 58 -108 -79 -160 -34 -7 -29 -34 -94 -151 -121 -152 62 8 -120 190 159 -148 -48 -107 150 -234 133 -100 163 54 22 41 -46 -88 199 -94 -32 167 -45 206 140 -161 146 15 156 -109 -59 -157 177 -78 -94 -43 4 42 -55 -31 -29 65 -140 195 -42 118 -127 -235 9 SQ 20210114T172142.4Z 7684.723407 180 1 48.72 2 64.96 178.61 68.55 157.26 0.00 1 0.00 1 0 33 1.278e-03 1.240e-03 1.081e-03 1.053e-03 5.328838e+01 1.903544e+02 1.337639e+02 6.749172e+02 2.429906e+02 271.84 -2.00 20.00 -2.00 445.57 0.00e+00 4.323892e-04 1.163400e-04 3.145377e-05 2.825473e-05 1.394760e-04 271.84 -2.00 20.00 -2.00 454.79 0.00e+00 7.486993e-04 1.076317e-05 5.511843e-05 1.514947e-05 1.327538e-05 271.84 -2.00 20.00 -2.00 436.17 0.00e+00 1.953756e+04 1.427812e+05 7.080268e+04 4.307003e+05 1.824384e+05 254.67 -2.00 11.30 -2.00 457.02 0.00e+00 3.785482e-01 2.948046e-02 1.492033e-02 1.831523e-02 3.972846e-02 223.37 -2.00 3.57 -2.00 454.16 0.00e+00 8.759616e-07 3.648406e-06 1.549648e-06 2.153388e-06 4.825942e-06 271.84 -2.00 20.00 -2.00 455.32 0.00e+00 2.348 0.000 397.00 473.00 4 7.7685e+00 1.1416e-03 6.3040e-03 7.3426e-04 1.3268e-03 6.4799e-02 1.3296e-03 1.2156e-03 4.4053e-04 1.6000e-03 -1.6061e-02 7.7974e-04 1.6174e-04 1.8630e-04 9.3277e-04 -1.9320e-04 2.5610e-04 5.7787e-05 4.5853e-05 3.0800e-04 1.2965e-03 1.3312e-04 4.0685e-05 2.6874e-05 1.5601e-04 4.3403e-04 -1.9006e-03 7.7099e-04 2.5349e-04 8.3867e-05 8.2355e-04 6.0141e-05 1.0349e-05 1.9635e-07 5.6747e-07 1.2376e-05 -1.8519e-05 1.4484e-05 8.2075e-07 6.7727e-07 1.7067e-05 -5.5912e-03 3.8645e-05 6.6170e-01 1.0427e-01 1.6132e-02 4.3523e-03 1.1754e-01 11 8 0 10 0 0 95.96 15.00 0.60 -0.00559 -0.00270 13 2 1 4 0 3746.800 21.88 15.00 18.76 75 265 60 7 81 57 -4 212 -61 -1 -137 62 -78 123 -86 -288 -151 -249 127 -96 31 -116 -37 -219 -83 -219 -90 -113 -82 15 95 -107 149 174 152 -89 89 170 -29 249 271 -13 -105 178 31 -9 -15 -18 133 266 87 251 -83 -94 -113 70 41 -161 95 37 111 177 -221 94 -106 200 174 4 -12 167 278 -116 47 -128 -165 -283 -144 -244 -214 -201 -24 146 210 19 -52 114 -3 122 4 -55 124 71 64 215 -213 -49 -161 -249 -55 70 -135 -74 -204 4 -173 -133 -24 -31 142 90 28 63 184 -96 -216 -149 -212 -223 38 -362 206 -93 58 -52 -53 -19 -202 -136 -38 -169 -108 -78 -69 -48 -166 44 47 34 -113 -60 -103 8 -169 -13 -138 215 126 108 -13 6 -45 43 237 -26 316 601 20 27 154 26 115 -73 101 50 142 34 33 38 -11 53 -81 -76 63 -125 -237 -84 85 -5 -21 1 189 -42 57 170 8 94 -137 43 -209 -9 -158 -34 4 54 72 8 -110 24 66 171 -42 -71 157 128 59 -40 53 -290 -108 -244 63 -224 35 19 46 159 124 11 -5 100 155 270 167 -10 38 157 214 89 -66 165 -48 -29 -269 190 252 44 265 205 204 64 79 15 215 193 230 -68 90 100 39 36 -81 -250 186 -152 122 169 126 -216 -99 -336 -241 -136 -122 -187 138 1 28 -34 124 146 49 -28 -160 58 -101 -86 -63 27 -156 174 -84 -25 88 -157 -220 70 -89 141 49 -21 -108 -107 -226 -61 -102 -120 71 -234 14 -183 198 -144 -48 -219 -297 -114 -72 -20 96 196 93 53 -175 24 -70 59 -28 -121 16 -44 -30 19 -36 -49 22 -53 -127 126 -84 62 219 112 -155 -312 27 86 -50 34 -44 -70 192 -136 123 -6 41 -185 -32 -73 -115 17 75 19 98 115 193 111 -34 -33 136 131 -42 7 5 -86 -120 89 -20 118 -106 -45 195 -63 -132 -52 106 101 -51 145 -15 -10 -147 -166 131 -76 -77 113 48 -251 -24 31 196 -18 76 19 136 97 58 30 -116 -5 195 -87 82 141 -70 -10 -234 129 -81 -61 -41 126 23 161 -66 -212 -16 201 67 -17 -81 -81 76 172 -83 -18 33 -40 50 -79 -60 -45 140 -172 46 1 54 -52 -75 -121 -38 7 143 105 -60 -113 -148 22 -73 52 66 3 75 -45 7 -75 -116 69 79 80 -239 25 58 -80 12 35 -62 86 141 -37 105 -49 273 -18 -22 -169 -68 -60 47 23 115 -23 78 118 126 -75 102 -186 51 -78 -165 72 -161 26 85 -9 -30 144 29 167 26 -92 74 28 219 19 -53 -29 -115 -65 -34 -80 199 -93 25 -239 -44 -48 59 106 154 -278 186 178 106 -4 -112 -153 192 114 -69 -48 116 -33 -47 -71 -154 -116 -75 -147 29 100 45 50 -9 62 214 47 6 63 45 -4 176 -51 -1 -115 52 -66 103 -73 -247 -129 -213 109 -83 27 -98 -31 -173 -65 -176 -75 -98 -73 14 84 -91 120 135 117 -71 76 149 -25 215 229 -11 -87 148 26 -7 -12 -15 105 216 74 215 -71 -80 -96 59 34 -134 78 32 97 158 -197 83 -95 184 163 4 -12 155 253 -104 41 -110 -136 -223 -111 -189 -174 -174 -21 132 191 17 -48 108 -3 118 4 -53 117 67 60 205 -202 -46 -151 -232 -50 63 -121 -67 -190 4 -171 -132 -23 -29 130 82 26 60 177 -92 -206 -140 -198 -207 36 -343 198 -91 58 -53 -53 -19 -199 -132 -36 -159 -100 -71 -63 -44 -156 42 45 32 -107 -57 -96 7 -158 -13 -132 211 124 105 -12 5 -41 39 214 -24 296 577 20 27 154 27 116 -74 100 48 137 33 33 38 -11 51 -73 -64 53 -109 -222 -82 84 -5 -19 1 176 -39 55 164 8 93 -135 42 -199 -8 -146 -32 4 52 70 7 -105 22 61 159 -41 -71 158 127 57 -36 47 -247 -92 -217 59 -215 34 18 44 150 117 11 -5 90 137 239 150 -9 35 142 185 73 -51 123 -36 -22 -205 142 184 31 189 152 163 55 75 15 224 204 241 -69 86 89 33 32 -76 -247 190 -156 125 174 126 -207 -88 -280 -198 -114 -109 -177 135 1 28 -34 120 139 47 -27 -159 58 -102 -88 -65 28 -164 182 -87 -26 89 -159 -222 70 -86 137 48 -21 -110 -106 -212 -54 -88 -104 64 -223 14 -177 192 -140 -47 -220 -301 -116 -73 -20 93 186 88 50 -168 24 -72 62 -30 -125 16 -44 -31 19 -38 -52 23 -55 -131 131 -88 64 228 116 -158 -313 28 87 -52 36 -46 -72 196 -140 127 -6 43 -195 -34 -76 -117 17 73 18 96 112 189 111 -35 -34 142 135 -43 7 5 -91 -129 96 -22 128 -114 -47 199 -64 -138 -56 115 108 -55 153 -15 -10 -157 -177 139 -82 -84 123 52 -278 -27 35 221 -21 85 21 152 108 63 32 -127 -6 214 -96 90 154 -76 -10 -244 132 -82 -62 -42 130 24 169 -71 -232 -18 223 74 -18 -89 -88 82 183 -89 -19 36 -44 54 -86 -66 -50 158 -195 52 1 60 -58 -83 -136 -43 8 161 118 -68 -129 -168 25 -81 57 72 3 81 -49 7 -85 -131 78 88 89 -264 27 65 -88 14 39 -69 96 159 -42 120 -57 315 -21 -25 -194 -78 -69 55 27 133 -27 91 138 146 -87 119 -216 59 -90 -192 83 -186 30 97 -10 -34 165 34 192 30 -103 82 31 246 22 -61 -33 -132 -75 -39 -94 236 -110 29 -278 -50 -53 64 116 171 -315 214 206 123 -5 -130 -177 218 129 -79 -55 135 -39 -55 -83 -179 -135 -87 -171 34 118 53 58 -10