File name: Pandora103s1_Downsview_20240311_L2Fit_fnvs4c3d20230309p1-8.txt File generation date: 20240312T053521.6Z Data description: Level 2 spectral fitting results file Data file version: fnvs4c3p1-8 Local principal investigator: Vitali Fioletov Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 103 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora103_OF_v3d20221207.txt Instrument calibration file used: Pandora103s1_CF_v3d20230309.txt Level 1 file used: Pandora103s1_Downsview_20240311_L1_smca1c3d20230309p1-8.txt Full location name: Environment Canada HQ - Downsview Short location name: Downsview Country of location: Canada Location latitude [deg]: 43.7810 Location longitude [deg]: -79.4680 Location altitude [m]: 187 Local noon date: 20240311 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OoB-data based on session 2 "Initial 1.8 calibration for delrin-free head sensor, absolute calibration done with an uncalibrated lamp, certificate of FEL1441 (GSFC) used" First and last pixel inside fitting window: 896 1440 Nominal wavelengths inside fitting window [nm]: 400.0981 400.2304 400.3627 400.4950 400.6272 400.7595 400.8917 401.0239 401.1561 401.2883 401.4204 401.5526 401.6847 401.8168 401.9490 402.0811 402.2131 402.3452 402.4773 402.6093 402.7413 402.8733 403.0053 403.1373 403.2693 403.4012 403.5332 403.6651 403.7970 403.9289 404.0608 404.1927 404.3245 404.4564 404.5882 404.7200 404.8518 404.9836 405.1154 405.2472 405.3789 405.5106 405.6424 405.7741 405.9057 406.0374 406.1691 406.3007 406.4324 406.5640 406.6956 406.8272 406.9587 407.0903 407.2219 407.3534 407.4849 407.6164 407.7479 407.8794 408.0108 408.1423 408.2737 408.4051 408.5365 408.6679 408.7993 408.9307 409.0620 409.1934 409.3247 409.4560 409.5873 409.7185 409.8498 409.9811 410.1123 410.2435 410.3747 410.5059 410.6371 410.7682 410.8994 411.0305 411.1616 411.2927 411.4238 411.5549 411.6860 411.8170 411.9481 412.0791 412.2101 412.3411 412.4721 412.6030 412.7340 412.8649 412.9958 413.1267 413.2576 413.3885 413.5193 413.6502 413.7810 413.9118 414.0426 414.1734 414.3042 414.4350 414.5657 414.6964 414.8272 414.9579 415.0886 415.2192 415.3499 415.4805 415.6112 415.7418 415.8724 416.0030 416.1335 416.2641 416.3946 416.5252 416.6557 416.7862 416.9167 417.0471 417.1776 417.3080 417.4385 417.5689 417.6993 417.8297 417.9600 418.0904 418.2207 418.3511 418.4814 418.6117 418.7419 418.8722 419.0025 419.1327 419.2629 419.3931 419.5233 419.6535 419.7837 419.9138 420.0440 420.1741 420.3042 420.4343 420.5644 420.6944 420.8245 420.9545 421.0845 421.2145 421.3445 421.4745 421.6045 421.7344 421.8644 421.9943 422.1242 422.2541 422.3839 422.5138 422.6436 422.7735 422.9033 423.0331 423.1629 423.2926 423.4224 423.5521 423.6819 423.8116 423.9413 424.0710 424.2006 424.3303 424.4599 424.5895 424.7192 424.8488 424.9783 425.1079 425.2374 425.3670 425.4965 425.6260 425.7555 425.8850 426.0144 426.1439 426.2733 426.4027 426.5321 426.6615 426.7909 426.9203 427.0496 427.1789 427.3083 427.4376 427.5668 427.6961 427.8254 427.9546 428.0838 428.2130 428.3422 428.4714 428.6006 428.7297 428.8589 428.9880 429.1171 429.2462 429.3753 429.5043 429.6334 429.7624 429.8914 430.0204 430.1494 430.2784 430.4074 430.5363 430.6652 430.7942 430.9231 431.0519 431.1808 431.3097 431.4385 431.5673 431.6961 431.8249 431.9537 432.0825 432.2112 432.3400 432.4687 432.5974 432.7261 432.8548 432.9834 433.1121 433.2407 433.3693 433.4979 433.6265 433.7551 433.8836 434.0122 434.1407 434.2692 434.3977 434.5262 434.6547 434.7831 434.9116 435.0400 435.1684 435.2968 435.4252 435.5535 435.6819 435.8102 435.9385 436.0668 436.1951 436.3234 436.4516 436.5799 436.7081 436.8363 436.9645 437.0927 437.2209 437.3490 437.4772 437.6053 437.7334 437.8615 437.9896 438.1176 438.2457 438.3737 438.5017 438.6297 438.7577 438.8857 439.0136 439.1416 439.2695 439.3974 439.5253 439.6532 439.7811 439.9089 440.0368 440.1646 440.2924 440.4202 440.5480 440.6757 440.8035 440.9312 441.0589 441.1866 441.3143 441.4420 441.5696 441.6973 441.8249 441.9525 442.0801 442.2077 442.3352 442.4628 442.5903 442.7179 442.8454 442.9728 443.1003 443.2278 443.3552 443.4827 443.6101 443.7375 443.8649 443.9922 444.1196 444.2469 444.3742 444.5015 444.6288 444.7561 444.8834 445.0106 445.1379 445.2651 445.3923 445.5195 445.6466 445.7738 445.9009 446.0281 446.1552 446.2823 446.4093 446.5364 446.6635 446.7905 446.9175 447.0445 447.1715 447.2985 447.4254 447.5524 447.6793 447.8062 447.9331 448.0600 448.1869 448.3137 448.4406 448.5674 448.6942 448.8210 448.9478 449.0745 449.2013 449.3280 449.4547 449.5814 449.7081 449.8348 449.9614 450.0881 450.2147 450.3413 450.4679 450.5945 450.7210 450.8476 450.9741 451.1006 451.2271 451.3536 451.4801 451.6065 451.7330 451.8594 451.9858 452.1122 452.2386 452.3649 452.4913 452.6176 452.7439 452.8702 452.9965 453.1228 453.2491 453.3753 453.5015 453.6277 453.7539 453.8801 454.0063 454.1324 454.2586 454.3847 454.5108 454.6369 454.7629 454.8890 455.0150 455.1411 455.2671 455.3931 455.5190 455.6450 455.7710 455.8969 456.0228 456.1487 456.2746 456.4005 456.5263 456.6522 456.7780 456.9038 457.0296 457.1554 457.2811 457.4069 457.5326 457.6583 457.7840 457.9097 458.0354 458.1611 458.2867 458.4123 458.5379 458.6635 458.7891 458.9147 459.0402 459.1657 459.2913 459.4168 459.5422 459.6677 459.7932 459.9186 460.0440 460.1694 460.2948 460.4202 460.5456 460.6709 460.7962 460.9216 461.0469 461.1721 461.2974 461.4227 461.5479 461.6731 461.7983 461.9235 462.0487 462.1739 462.2990 462.4241 462.5492 462.6743 462.7994 462.9245 463.0495 463.1746 463.2996 463.4246 463.5496 463.6746 463.7995 463.9245 464.0494 464.1743 464.2992 464.4241 464.5489 464.6738 464.7986 464.9234 465.0482 465.1730 465.2978 465.4225 465.5473 465.6720 465.7967 465.9214 466.0461 466.1707 466.2954 466.4200 466.5446 466.6692 466.7938 466.9184 467.0429 467.1674 467.2920 467.4165 467.5409 467.6654 467.7899 467.9143 468.0387 468.1631 468.2875 468.4119 468.5363 468.6606 468.7850 468.9093 469.0336 469.1579 469.2821 469.4064 469.5306 469.6548 469.7790 469.9032 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-708: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 709-1253: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------