File name: Pandora104s1_Downsview_20221206_L2Fit_fnvs4c19d20221101p1-8.txt File generation date: 20241127T161843.1Z Data description: Level 2 spectral fitting results file Data file version: fnvs4c19p1-8 Local principal investigator: Vitali Fioletov Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 104 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora104_OF_v10d20171009.txt Instrument calibration file used: Pandora104s1_CF_v19d20221101.txt Level 1 file used: Pandora104s1_Downsview_20221206_L1_smca1c19d20221101p1-8.txt Full location name: Environment Canada HQ - Downsview Short location name: Downsview Country of location: Canada Location latitude [deg]: 43.7810 Location longitude [deg]: -79.4680 Location altitude [m]: 187 Local noon date: 20221206 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: based on session 14 for VP 20221101 First and last pixel inside fitting window: 904 1451 Nominal wavelengths inside fitting window [nm]: 400.0808 400.2127 400.3445 400.4763 400.6081 400.7399 400.8716 401.0034 401.1351 401.2668 401.3986 401.5302 401.6619 401.7936 401.9253 402.0569 402.1885 402.3201 402.4517 402.5833 402.7149 402.8464 402.9780 403.1095 403.2410 403.3725 403.5040 403.6355 403.7669 403.8984 404.0298 404.1612 404.2926 404.4240 404.5554 404.6867 404.8181 404.9494 405.0807 405.2120 405.3433 405.4746 405.6058 405.7371 405.8683 405.9995 406.1307 406.2619 406.3931 406.5242 406.6554 406.7865 406.9176 407.0487 407.1798 407.3109 407.4420 407.5730 407.7040 407.8350 407.9661 408.0970 408.2280 408.3590 408.4899 408.6208 408.7518 408.8827 409.0136 409.1444 409.2753 409.4061 409.5370 409.6678 409.7986 409.9294 410.0601 410.1909 410.3217 410.4524 410.5831 410.7138 410.8445 410.9752 411.1058 411.2365 411.3671 411.4977 411.6283 411.7589 411.8895 412.0200 412.1506 412.2811 412.4116 412.5421 412.6726 412.8031 412.9335 413.0640 413.1944 413.3248 413.4552 413.5856 413.7160 413.8463 413.9767 414.1070 414.2373 414.3676 414.4979 414.6282 414.7584 414.8887 415.0189 415.1491 415.2793 415.4095 415.5397 415.6698 415.8000 415.9301 416.0602 416.1903 416.3204 416.4504 416.5805 416.7105 416.8406 416.9706 417.1006 417.2305 417.3605 417.4905 417.6204 417.7503 417.8802 418.0101 418.1400 418.2699 418.3997 418.5296 418.6594 418.7892 418.9190 419.0487 419.1785 419.3083 419.4380 419.5677 419.6974 419.8271 419.9568 420.0864 420.2161 420.3457 420.4753 420.6049 420.7345 420.8641 420.9936 421.1232 421.2527 421.3822 421.5117 421.6412 421.7707 421.9001 422.0296 422.1590 422.2884 422.4178 422.5472 422.6765 422.8059 422.9352 423.0646 423.1939 423.3232 423.4524 423.5817 423.7110 423.8402 423.9694 424.0986 424.2278 424.3570 424.4861 424.6153 424.7444 424.8735 425.0026 425.1317 425.2608 425.3898 425.5189 425.6479 425.7769 425.9059 426.0349 426.1639 426.2928 426.4218 426.5507 426.6796 426.8085 426.9374 427.0662 427.1951 427.3239 427.4527 427.5816 427.7103 427.8391 427.9679 428.0966 428.2254 428.3541 428.4828 428.6115 428.7401 428.8688 428.9974 429.1261 429.2547 429.3833 429.5118 429.6404 429.7690 429.8975 430.0260 430.1545 430.2830 430.4115 430.5400 430.6684 430.7968 430.9253 431.0537 431.1821 431.3104 431.4388 431.5671 431.6955 431.8238 431.9521 432.0804 432.2086 432.3369 432.4651 432.5933 432.7215 432.8497 432.9779 433.1061 433.2342 433.3624 433.4905 433.6186 433.7467 433.8748 434.0028 434.1309 434.2589 434.3869 434.5149 434.6429 434.7708 434.8988 435.0267 435.1547 435.2826 435.4105 435.5383 435.6662 435.7940 435.9219 436.0497 436.1775 436.3053 436.4331 436.5608 436.6886 436.8163 436.9440 437.0717 437.1994 437.3270 437.4547 437.5823 437.7099 437.8375 437.9651 438.0927 438.2203 438.3478 438.4753 438.6029 438.7304 438.8578 438.9853 439.1128 439.2402 439.3676 439.4950 439.6224 439.7498 439.8772 440.0045 440.1319 440.2592 440.3865 440.5138 440.6410 440.7683 440.8955 441.0228 441.1500 441.2772 441.4043 441.5315 441.6586 441.7858 441.9129 442.0400 442.1671 442.2942 442.4212 442.5483 442.6753 442.8023 442.9293 443.0563 443.1832 443.3102 443.4371 443.5641 443.6910 443.8178 443.9447 444.0716 444.1984 444.3252 444.4521 444.5789 444.7056 444.8324 444.9592 445.0859 445.2126 445.3393 445.4660 445.5927 445.7193 445.8460 445.9726 446.0992 446.2258 446.3524 446.4790 446.6055 446.7320 446.8586 446.9851 447.1116 447.2380 447.3645 447.4909 447.6174 447.7438 447.8702 447.9965 448.1229 448.2493 448.3756 448.5019 448.6282 448.7545 448.8808 449.0070 449.1333 449.2595 449.3857 449.5119 449.6381 449.7642 449.8904 450.0165 450.1426 450.2687 450.3948 450.5209 450.6470 450.7730 450.8990 451.0250 451.1510 451.2770 451.4030 451.5289 451.6548 451.7807 451.9066 452.0325 452.1584 452.2842 452.4101 452.5359 452.6617 452.7875 452.9133 453.0390 453.1648 453.2905 453.4162 453.5419 453.6676 453.7932 453.9189 454.0445 454.1701 454.2957 454.4213 454.5469 454.6725 454.7980 454.9235 455.0490 455.1745 455.3000 455.4255 455.5509 455.6763 455.8017 455.9271 456.0525 456.1779 456.3032 456.4286 456.5539 456.6792 456.8045 456.9297 457.0550 457.1802 457.3055 457.4307 457.5559 457.6810 457.8062 457.9313 458.0565 458.1816 458.3067 458.4318 458.5568 458.6819 458.8069 458.9319 459.0569 459.1819 459.3069 459.4318 459.5568 459.6817 459.8066 459.9315 460.0564 460.1812 460.3061 460.4309 460.5557 460.6805 460.8053 460.9301 461.0548 461.1795 461.3043 461.4290 461.5536 461.6783 461.8030 461.9276 462.0522 462.1768 462.3014 462.4260 462.5505 462.6751 462.7996 462.9241 463.0486 463.1731 463.2976 463.4220 463.5464 463.6708 463.7952 463.9196 464.0440 464.1683 464.2927 464.4170 464.5413 464.6656 464.7898 464.9141 465.0383 465.1625 465.2867 465.4109 465.5351 465.6593 465.7834 465.9075 466.0316 466.1557 466.2798 466.4039 466.5279 466.6519 466.7759 466.8999 467.0239 467.1479 467.2718 467.3957 467.5197 467.6436 467.7674 467.8913 468.0152 468.1390 468.2628 468.3866 468.5104 468.6342 468.7579 468.8816 469.0054 469.1291 469.2528 469.3764 469.5001 469.6237 469.7473 469.8709 469.9945 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Columns 161-708: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 709-1256: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------