File name: Pandora169s1_Egbert_20210420_L2Fit_ffus5c14d20201119p1-8.txt File generation date: 20241103T014618.8Z Data description: Level 2 spectral fitting results file Data file version: ffus5c14p1-8 Local principal investigator: Vitali Fioletov Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 169 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora169_OF_v3d20200220.txt Instrument calibration file used: Pandora169s1_CF_v14d20201119.txt Level 1 file used: Pandora169s1_Egbert_20210420_L1_smca1c14d20201119p1-8.txt Full location name: Center for Atmospheric Research Experiments (CARE) - Egbert Short location name: Egbert Country of location: Canada Location latitude [deg]: 44.2300 Location longitude [deg]: -79.7800 Location altitude [m]: 251 Local noon date: 20210420 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 352 617 Nominal wavelengths inside fitting window [nm]: 322.5797 322.7192 322.8586 322.9981 323.1375 323.2769 323.4163 323.5557 323.6951 323.8345 323.9739 324.1132 324.2526 324.3919 324.5312 324.6705 324.8098 324.9491 325.0884 325.2277 325.3669 325.5062 325.6454 325.7846 325.9238 326.0630 326.2022 326.3414 326.4805 326.6197 326.7588 326.8979 327.0371 327.1762 327.3153 327.4543 327.5934 327.7325 327.8715 328.0105 328.1496 328.2886 328.4276 328.5666 328.7055 328.8445 328.9835 329.1224 329.2613 329.4002 329.5391 329.6780 329.8169 329.9558 330.0947 330.2335 330.3723 330.5112 330.6500 330.7888 330.9276 331.0663 331.2051 331.3439 331.4826 331.6213 331.7601 331.8988 332.0375 332.1762 332.3148 332.4535 332.5921 332.7308 332.8694 333.0080 333.1466 333.2852 333.4238 333.5624 333.7009 333.8395 333.9780 334.1165 334.2550 334.3935 334.5320 334.6705 334.8089 334.9474 335.0858 335.2242 335.3627 335.5011 335.6395 335.7778 335.9162 336.0546 336.1929 336.3312 336.4696 336.6079 336.7462 336.8844 337.0227 337.1610 337.2992 337.4375 337.5757 337.7139 337.8521 337.9903 338.1285 338.2666 338.4048 338.5429 338.6810 338.8192 338.9573 339.0954 339.2334 339.3715 339.5096 339.6476 339.7857 339.9237 340.0617 340.1997 340.3377 340.4756 340.6136 340.7516 340.8895 341.0274 341.1653 341.3032 341.4411 341.5790 341.7169 341.8547 341.9926 342.1304 342.2682 342.4060 342.5438 342.6816 342.8194 342.9571 343.0949 343.2326 343.3703 343.5080 343.6457 343.7834 343.9211 344.0587 344.1964 344.3340 344.4716 344.6093 344.7469 344.8844 345.0220 345.1596 345.2971 345.4347 345.5722 345.7097 345.8472 345.9847 346.1222 346.2596 346.3971 346.5345 346.6720 346.8094 346.9468 347.0842 347.2216 347.3589 347.4963 347.6336 347.7710 347.9083 348.0456 348.1829 348.3202 348.4574 348.5947 348.7319 348.8692 349.0064 349.1436 349.2808 349.4180 349.5551 349.6923 349.8294 349.9666 350.1037 350.2408 350.3779 350.5150 350.6521 350.7891 350.9262 351.0632 351.2002 351.3372 351.4742 351.6112 351.7482 351.8851 352.0221 352.1590 352.2959 352.4329 352.5698 352.7066 352.8435 352.9804 353.1172 353.2541 353.3909 353.5277 353.6645 353.8013 353.9380 354.0748 354.2116 354.3483 354.4850 354.6217 354.7584 354.8951 355.0318 355.1684 355.3051 355.4417 355.5783 355.7149 355.8515 355.9881 356.1247 356.2613 356.3978 356.5343 356.6709 356.8074 356.9439 357.0803 357.2168 357.3533 357.4897 357.6262 357.7626 357.8990 358.0354 358.1718 358.3081 358.4445 358.5808 358.7172 358.8535 358.9898 359.1261 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-435: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 436-701: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210420T134136.4Z 7780.570560 215 1 50.75 2 56.42 107.82 108.96 26.19 0.00 1 0.00 1 0 33 6.994e-03 6.619e-03 3.194e-03 3.000e-03 1.279260e-06 9.991574e-07 1.762943e-07 3.633608e-07 2.289142e-06 228.52 -2.00 3.58 -2.00 339.67 0.00e+00 -2.142174e-05 2.693581e-04 5.134429e-05 1.049035e-05 6.143552e-04 277.29 -2.00 20.00 -2.00 337.12 0.00e+00 -5.082094e-05 4.282260e-05 4.994525e-06 2.388257e-05 1.083482e-04 277.29 -2.00 20.00 -2.00 345.77 0.00e+00 1.410152e-04 1.229826e-04 2.295486e-05 9.445452e-06 3.025758e-04 277.29 -2.00 20.00 -2.00 344.25 0.00e+00 3.028926e+05 2.466468e+05 6.185432e+04 1.866129e+05 5.655523e+05 259.58 -2.00 11.31 -2.00 351.26 0.00e+00 3.794705e-01 3.887926e-03 3.262672e-03 1.345582e-03 7.857134e-03 228.52 -2.00 3.58 -2.00 330.49 0.00e+00 2.982296e-03 5.342824e-03 1.886619e-03 8.329502e-05 8.807365e-03 277.29 -2.00 20.00 -2.00 328.46 0.00e+00 1.802 0.000 319.50 362.20 4 7.8333e+00 4.1208e-03 1.2392e-02 1.3578e-03 1.0052e-02 8.8150e-02 9.7104e-04 2.0451e-03 2.3804e-04 2.2534e-03 -1.2960e-02 1.9163e-03 6.6310e-04 7.0630e-05 4.4854e-03 -2.1300e-03 1.0051e-03 6.4229e-04 1.1795e-05 1.8560e-03 4.1260e-03 1.5491e-03 5.5993e-04 5.0368e-05 3.2873e-03 1.0989e-04 -2.1176e-02 2.5876e-03 3.4967e-04 6.6475e-05 6.1460e-03 -3.8023e-04 4.5646e-05 4.6222e-06 5.7918e-07 1.0987e-04 -3.8218e-03 -2.7441e-04 1.2860e-01 2.8195e-01 2.3718e-02 4.0731e-03 6.5837e-01 12 9 8 11 32 0 99.69 22.70 1.65 -0.00382 -0.00851 16 3 1 5 0 3171.040 26.41 20.00 22.70 6.93 26.7 941.11 -1130 1116 -323 1240 -1856 -1370 1022 -1045 1496 1149 913 848 -1130 409 -23 -1055 18 -689 -2071 -480 260 347 311 1063 668 442 -78 1436 -259 -73 -305 -998 -461 -998 -311 -35 1695 -326 -583 691 1119 -234 -1530 840 1459 -104 -37 285 -243 -2338 -307 110 276 159 -217 -519 436 423 74 39 -124 -984 354 397 843 182 1102 -735 -169 -24 -294 369 -1092 265 487 358 -415 379 757 377 656 288 -1142 36 254 -570 -181 -364 205 449 844 -710 -340 -65 -254 -523 277 203 119 760 452 177 1068 -271 -275 -1732 131 1072 -532 -118 284 -240 2 1441 -224 765 745 -979 677 -232 -292 344 175 -372 -385 -84 -193 -247 683 -100 -205 -611 -1410 -1262 -672 -174 -587 1638 -36 -456 200 -41 485 -181 151 327 -822 317 845 487 21 -89 425 342 -1150 -81 -115 -730 -164 84 -426 79 -508 596 1226 1141 -440 421 -305 688 -556 83 -132 633 -101 -339 -225 176 -1291 571 -652 -272 254 132 -146 454 -561 521 191 -102 -700 -648 -117 -583 752 -361 260 -690 77 380 917 158 1976 -66 273 -335 -349 -8 66 -372 -703 -437 -356 835 685 -787 318 -332 -127 -355 274 -87 448 -228 -150 -1498 217 472 -691 6 1076 -688 -41 991 713 -992 -615 427 -663 425 -691 -290 911 -193 -1 388 61 -651 746 -370 -199 843 607 -885 594 915 230 -29 -261 -1822 688 800 -477 -645 -21 71 -561 530 -156 625 -1022 -790 600 -638 923 741 613 582 -794 285 -16 -706 11 -440 -1361 -328 187 266 252 900 584 393 -70 1264 -233 -66 -279 -918 -415 -888 -273 -30 1450 -276 -484 563 915 -196 -1301 704 1249 -94 -35 287 -253 -2507 -328 117 296 171 -228 -528 418 386 67 35 -115 -936 332 370 794 176 1087 -745 -169 -23 -288 365 -1102 267 486 355 -413 372 720 348 596 265 -1099 35 257 -595 -191 -382 209 454 866 -759 -376 -71 -272 -518 247 170 102 695 439 173 994 -240 -234 -1502 118 1033 -546 -122 287 -236 2 1421 -234 818 802 -1073 720 -240 -296 347 182 -408 -441 -98 -226 -285 764 -109 -219 -650 -1511 -1354 -707 -178 -598 1659 -39 -513 228 -46 537 -198 164 363 -947 366 968 552 23 -97 456 351 -1088 -70 -95 -612 -146 80 -438 85 -565 663 1365 1264 -487 453 -316 684 -559 86 -141 688 -113 -382 -255 198 -1410 582 -639 -266 256 139 -158 490 -603 556 206 -110 -741 -663 -115 -581 753 -366 270 -753 88 454 1118 193 2345 -78 316 -381 -387 -9 70 -400 -788 -506 -415 939 729 -792 304 -319 -127 -379 305 -99 513 -264 -175 -1794 260 561 -826 8 1276 -833 -49 1191 856 -1190 -722 484 -744 469 -769 -325 1022 -220 -1 413 61 -617 661 -330 -180 775 586 -899 597 883 207 -24 -204 -1391 511 611 -382 -559 -20 72 SS 20210420T134628.4Z 7780.573940 219 1 50.88 2 55.59 108.86 108.59 27.26 0.00 1 0.00 1 0 33 6.321e-04 5.973e-04 7.609e-05 7.250e-05 5.823104e-07 2.422285e-08 6.780740e-08 3.633135e-07 2.071124e-07 228.52 -2.00 3.58 -2.00 339.93 0.00e+00 2.616628e-04 6.626866e-06 1.787688e-05 1.053359e-05 5.697524e-05 277.29 -2.00 20.00 -2.00 337.35 0.00e+00 1.727866e-05 1.006828e-06 1.226074e-06 2.388328e-05 9.582040e-06 277.29 -2.00 20.00 -2.00 346.10 0.00e+00 4.364409e-05 2.930184e-06 1.539801e-05 9.405638e-06 2.743214e-05 277.29 -2.00 20.00 -2.00 344.67 0.00e+00 2.824599e+05 6.000113e+03 3.877629e+04 1.866008e+05 5.224645e+04 259.58 -2.00 11.31 -2.00 351.88 0.00e+00 3.310106e-01 9.398658e-05 2.703910e-03 1.345520e-03 7.131192e-04 228.52 -2.00 3.58 -2.00 330.27 0.00e+00 -2.530347e-03 1.229725e-04 7.037324e-04 7.522009e-05 7.861787e-04 277.29 -2.00 20.00 -2.00 328.19 0.00e+00 1.764 0.000 319.50 362.20 4 8.0526e-01 1.0019e-04 1.2121e-02 1.3584e-03 9.0886e-04 -3.2005e-02 2.4725e-05 1.9552e-03 2.3871e-04 2.1114e-04 3.3923e-03 4.7018e-05 4.9203e-04 7.2197e-05 4.1325e-04 -1.0201e-04 2.3500e-05 5.0336e-04 1.1780e-05 1.6827e-04 -3.9056e-04 3.7625e-05 3.4629e-04 5.2559e-05 3.0724e-04 1.2642e-01 5.6484e-03 6.1729e-05 2.4632e-04 6.8897e-05 5.1385e-04 1.0206e-04 1.0717e-06 3.9009e-06 5.2795e-07 9.9636e-06 -8.6047e-03 9.3781e-05 -1.4750e+00 6.7686e-03 2.0536e-02 4.4676e-03 5.9095e-02 11 8 0 10 0 0 99.97 22.70 0.20 -0.00860 -0.00735 2378 508 1 5 0 20.670 26.41 20.00 22.70 7.02 26.8 942.09 6 -154 -133 -185 -124 -53 -63 -4 11 -7 41 84 137 92 117 53 -111 -55 47 -2 -30 18 52 41 92 73 40 36 -48 -44 12 -22 25 13 84 105 40 19 -45 -37 24 12 32 55 -46 -73 -28 -67 -51 -18 -50 -74 -82 -101 -21 -59 18 115 -40 -25 -6 -78 23 34 -33 -50 -16 -41 31 31 -26 -20 40 19 21 52 58 101 115 69 10 61 2 -25 -19 -22 14 52 92 -30 -38 -7 -143 -58 37 116 99 -33 -134 -159 -83 22 78 95 69 -17 -106 -46 -34 41 71 5 30 39 -71 -23 26 -63 26 110 5 40 56 6 -11 -6 17 -3 14 42 -12 -37 -48 -1 79 88 -3 25 -7 -67 5 46 -4 -17 25 -67 -99 -11 -31 -99 -99 -25 -54 -80 79 -48 -44 15 -10 15 27 12 24 36 -96 -9 29 -29 24 26 -33 -15 78 -15 -49 14 -41 -12 16 10 20 -85 7 48 10 55 36 -19 -2 76 51 -37 74 19 59 134 -1 40 68 -29 -44 33 -49 -77 23 -22 -20 73 45 -56 5 10 -24 -43 -8 13 40 -7 35 68 60 27 4 4 38 -37 -29 41 -11 -49 49 4 9 -4 -9 37 4 7 -27 22 50 -42 -29 -48 -57 -20 -178 -107 95 -82 -42 113 0 -65 -31 -85 -109 -140 -186 -2 85 -20 139 163 93 169 4 -86 -74 -105 -74 -33 -40 -3 7 -5 28 60 99 67 83 38 -76 -38 32 -1 -22 14 43 35 79 64 35 31 -42 -38 10 -20 22 11 72 90 34 16 -37 -31 20 10 26 46 -39 -64 -26 -64 -50 -18 -50 -74 -83 -102 -21 -56 17 103 -35 -22 -5 -72 21 31 -30 -47 -16 -39 30 29 -24 -19 39 18 20 51 56 97 108 63 10 55 2 -24 -19 -22 14 52 91 -30 -38 -7 -149 -61 38 112 89 -28 -116 -146 -79 22 72 85 60 -15 -96 -44 -34 42 71 5 29 38 -73 -24 27 -66 27 112 5 40 57 6 -11 -7 18 -4 16 45 -12 -39 -50 -1 82 89 -3 25 -8 -73 6 50 -5 -18 26 -72 -110 -12 -35 -109 -109 -27 -57 -82 76 -44 -39 13 -9 14 27 13 27 39 -107 -9 32 -31 25 26 -34 -16 84 -16 -54 16 -46 -13 17 11 20 -85 7 51 11 60 39 -20 -2 83 55 -39 76 19 61 141 -1 44 78 -34 -53 39 -57 -91 27 -25 -23 79 49 -61 5 11 -28 -49 -8 13 40 -7 36 74 68 31 5 5 45 -44 -35 49 -13 -59 59 5 11 -4 -11 45 5 8 -31 25 57 -48 -33 -56 -65 -22 -190 -108 93 -81 -42 113 0 -70 -34 -89 -108 -130 -165 -2 74 -18 127 157 96 184 SS 20210420T135151.6Z 7780.577681 222 1 1.28 2 54.68 110.02 108.17 28.43 0.00 1 0.00 1 0 33 7.756e-04 7.506e-04 6.496e-04 6.207e-04 1.231348e-06 2.071970e-07 6.153130e-08 3.633169e-07 2.541835e-07 228.52 -2.00 3.58 -2.00 339.89 0.00e+00 1.378519e-04 5.669234e-05 1.611931e-05 1.053156e-05 6.978107e-05 277.29 -2.00 20.00 -2.00 337.32 0.00e+00 6.381200e-05 8.644933e-06 1.396846e-06 2.388313e-05 1.177493e-05 277.29 -2.00 20.00 -2.00 346.05 0.00e+00 1.378313e-05 2.510588e-05 1.520155e-05 9.411969e-06 3.364929e-05 277.29 -2.00 20.00 -2.00 344.64 0.00e+00 2.205353e+05 5.123768e+04 3.817074e+04 1.865980e+05 6.396536e+04 259.58 -2.00 11.31 -2.00 351.90 0.00e+00 3.248629e-01 7.984702e-04 2.694632e-03 1.345426e-03 8.716706e-04 228.52 -2.00 3.58 -2.00 330.24 0.00e+00 -1.536480e-03 1.045317e-03 8.999041e-04 7.535806e-05 9.671253e-04 277.29 -2.00 20.00 -2.00 328.15 0.00e+00 1.725 0.000 319.50 362.20 4 1.4015e+00 8.5586e-04 1.1849e-02 1.3583e-03 1.1157e-03 -2.4467e-02 2.0960e-04 1.9136e-03 2.3865e-04 2.5779e-04 5.2549e-03 4.0111e-04 4.8561e-04 7.1387e-05 5.0544e-04 -1.0985e-03 2.0017e-04 4.9980e-04 1.1760e-05 2.0683e-04 -5.2059e-04 3.2052e-04 3.4384e-04 5.1991e-05 3.7595e-04 7.1582e-02 3.0482e-03 5.2700e-04 2.5813e-04 6.9600e-05 6.3637e-04 6.0554e-06 9.1687e-06 3.8001e-06 5.3681e-07 1.2224e-05 -8.2410e-03 -1.1536e-05 -1.4212e+00 5.8007e-02 2.0768e-02 4.5431e-03 7.2767e-02 12 9 9 12 1 1 63.70 22.70 0.19 -0.00824 -0.00817 22 219 1 5 0 48.170 26.41 20.00 22.70 7.24 26.8 943.33 65 -91 -72 19 109 78 -74 -16 -24 -81 87 155 -99 -64 -40 -59 -274 -202 210 52 61 -5 62 -65 65 97 -64 63 77 -78 25 -47 -106 -3 -39 2 68 100 -35 17 153 -130 131 35 122 5 100 -22 9 148 -15 -47 -77 -121 -105 -69 -109 126 -59 -78 57 -117 85 -31 21 -61 63 -20 -5 110 131 3 11 -16 7 -19 99 54 84 22 -63 -31 -40 36 -138 -80 23 76 80 -7 -61 35 -205 -117 -90 30 12 72 -20 -30 -48 -58 82 133 74 74 -33 34 -53 -23 13 45 36 110 -17 -129 56 -103 6 110 -3 -38 129 -41 95 32 41 -77 -41 -15 29 36 -3 1 86 -10 16 9 -12 -123 -133 23 -38 -8 4 -10 -56 92 57 15 -114 -12 -134 -133 70 80 -24 -24 27 -72 64 41 52 62 -82 24 40 -23 3 -5 -56 86 53 -10 52 -23 53 53 33 -21 -32 -138 -78 22 57 61 -135 -4 -74 159 7 -109 24 -76 -83 162 -63 98 26 62 85 140 2 -71 82 -32 -22 91 -50 -18 -41 -64 -8 -25 12 37 -61 -101 -86 -106 37 60 -8 30 15 -37 -36 -25 32 -110 25 74 15 102 92 43 137 -8 -41 9 -15 -45 41 15 -24 19 -163 -95 -56 -118 -63 -16 -73 -97 26 17 -60 33 20 -2 66 15 89 137 -125 147 37 -52 -41 11 67 49 -47 -11 -16 -56 62 110 -72 -46 -28 -41 -192 -139 147 38 45 -4 51 -54 56 83 -55 54 66 -68 22 -42 -92 -2 -33 2 58 85 -29 14 126 -109 110 30 103 4 93 -21 8 147 -15 -47 -77 -122 -103 -67 -101 114 -53 -71 52 -109 78 -29 20 -57 60 -20 -5 105 125 3 11 -16 7 -18 95 52 79 20 -56 -28 -37 35 -136 -79 24 76 79 -7 -62 35 -213 -122 -92 29 11 61 -18 -28 -47 -57 77 121 65 66 -30 33 -53 -23 13 43 35 108 -17 -134 59 -109 6 111 -3 -38 131 -44 103 35 45 -86 -45 -16 30 38 -3 1 89 -11 16 9 -13 -133 -146 25 -41 -9 4 -10 -62 104 64 17 -125 -13 -144 -136 67 73 -21 -22 26 -71 66 43 57 68 -91 26 44 -25 3 -5 -57 90 57 -11 57 -25 59 58 36 -22 -32 -138 -80 24 62 66 -147 -5 -81 173 7 -114 24 -79 -86 169 -67 107 29 73 102 168 2 -82 93 -37 -25 98 -54 -20 -46 -74 -9 -29 13 39 -62 -102 -89 -116 42 69 -10 35 17 -44 -43 -30 38 -130 29 90 18 123 110 51 161 -9 -47 10 -17 -52 48 17 -28 21 -173 -96 -55 -115 -62 -16 -76 -104 28 18 -60 30 18 -1 58 13 81 132 -130 160 SS 20210420T144400.7Z 7780.613897 256 1 49.34 2 46.30 122.54 103.25 39.24 0.00 1 0.00 1 0 33 1.399e-03 1.289e-03 1.025e-03 9.746e-04 -2.413183e-07 3.237110e-07 6.384860e-08 3.633663e-07 4.581063e-07 228.53 -2.00 3.58 -2.00 339.66 0.00e+00 3.618464e-04 8.744266e-05 9.345846e-06 1.048967e-05 1.240804e-04 277.30 -2.00 20.00 -2.00 337.09 0.00e+00 -3.706707e-05 1.384268e-05 1.302761e-06 2.388250e-05 2.158955e-05 277.30 -2.00 20.00 -2.00 345.82 0.00e+00 1.286079e-04 3.972215e-05 1.540771e-05 9.441158e-06 6.057951e-05 277.30 -2.00 20.00 -2.00 344.33 0.00e+00 2.058537e+05 7.983832e+04 3.534630e+04 1.866046e+05 1.135768e+05 259.59 -2.00 11.31 -2.00 351.51 0.00e+00 2.839916e-01 1.219499e-03 2.277774e-03 1.345242e-03 1.535931e-03 228.53 -2.00 3.58 -2.00 330.28 0.00e+00 1.465223e-03 1.655712e-03 1.233294e-03 8.208260e-05 1.739393e-03 277.30 -2.00 20.00 -2.00 328.22 0.00e+00 1.445 0.000 319.50 362.20 4 6.0941e+00 1.3468e-03 9.9352e-03 1.3579e-03 2.0277e-03 1.2057e-02 3.1956e-04 1.6145e-03 2.3830e-04 4.5559e-04 2.2076e-03 6.1956e-04 4.0162e-04 6.9414e-05 8.9648e-04 -3.8985e-04 3.1625e-04 4.5406e-04 1.1672e-05 3.6984e-04 -4.7764e-05 4.9701e-04 3.3027e-04 4.9887e-05 6.6164e-04 7.9568e-04 -4.7773e-03 8.5313e-04 1.6728e-04 6.7533e-05 1.2217e-03 1.1539e-04 1.4721e-05 3.5439e-06 5.4634e-07 2.2052e-05 -8.1649e-03 8.3457e-05 -8.7344e-01 9.3151e-02 1.3188e-02 4.3946e-03 1.3518e-01 12 8 8 10 0 0 99.99 22.68 0.25 -0.00816 -0.00674 77 16 1 5 0 640.700 26.41 20.01 22.68 7.83 26.9 947.25 -266 186 -311 254 -347 -659 71 -9 64 394 -164 183 -84 116 151 183 139 -214 67 -114 121 43 -42 33 223 89 45 119 -226 72 220 -154 -33 -118 -105 179 152 1 -236 -80 195 0 -166 239 -103 -43 -118 30 -97 -276 -150 -132 -7 80 75 129 -58 117 100 -150 94 -133 -22 -67 94 -111 80 16 -53 -60 2 28 -292 100 270 102 -161 -94 332 106 190 177 -166 -54 72 -73 -40 24 16 30 111 -74 -126 -2 355 -125 135 -88 -166 -25 -77 50 165 77 -2 -131 -203 65 -92 45 198 -164 139 170 -71 82 102 -163 56 -30 -11 182 24 -53 -29 -33 48 -99 -32 -108 -130 -24 -237 -220 14 -2 -12 239 225 -142 -78 -6 -45 -60 -138 118 -214 86 154 5 -47 39 -84 181 -270 -123 -119 -28 71 105 -27 54 -65 12 155 89 -36 -74 -74 253 -32 -154 51 99 -44 -57 -27 97 -107 181 129 47 104 73 23 51 7 0 82 -81 -115 -141 162 -16 162 -94 135 -254 182 -92 52 -75 287 -41 -54 -184 -19 65 162 -136 63 -61 2 5 77 -210 -26 -104 45 75 -37 84 136 26 62 -91 4 60 6 -47 65 -50 41 -22 45 -134 43 -6 -83 -129 -145 -43 134 -50 -158 -59 -191 25 236 20 -80 299 -221 -52 177 98 -94 62 -19 -166 71 -74 -230 191 184 57 -146 99 -165 140 -202 -402 44 -6 41 265 -115 130 -61 84 108 128 95 -144 46 -81 91 34 -35 29 197 79 40 106 -201 65 199 -140 -29 -104 -93 158 133 0 -200 -67 164 0 -141 203 -89 -38 -111 29 -99 -284 -155 -138 -8 84 77 129 -56 107 91 -138 88 -126 -21 -63 89 -106 79 16 -52 -58 2 27 -288 99 266 100 -158 -91 316 98 174 163 -158 -53 72 -75 -41 25 16 30 113 -77 -135 -2 371 -122 121 -75 -143 -23 -74 49 155 68 -2 -114 -185 63 -94 46 199 -160 135 168 -74 87 109 -175 59 -31 -11 182 25 -57 -32 -38 55 -112 -35 -117 -138 -26 -249 -232 15 -2 -12 244 238 -157 -87 -7 -49 -65 -149 129 -242 97 175 5 -52 42 -90 186 -257 -108 -101 -24 64 101 -27 57 -72 13 172 98 -40 -79 -77 253 -32 -159 54 107 -49 -63 -31 109 -116 186 127 46 106 77 25 56 7 0 88 -88 -121 -145 162 -16 165 -96 142 -276 206 -109 63 -90 341 -48 -62 -208 -22 69 171 -147 70 -70 2 6 83 -213 -25 -102 45 80 -41 95 156 30 72 -108 5 71 7 -56 77 -60 50 -27 54 -159 50 -7 -93 -144 -162 -48 152 -57 -178 -64 -196 24 217 18 -75 285 -220 -54 183 97 -87 53 -16 -132 57 -61 -194 173 181 59 SS 20210420T150005.8Z 7780.625067 268 1 49.61 2 43.93 126.98 101.46 42.39 0.00 1 0.00 1 0 33 1.282e-03 1.228e-03 9.321e-04 8.832e-04 3.975409e-07 2.940278e-07 5.869730e-08 3.633587e-07 4.198722e-07 228.53 -2.00 3.58 -2.00 339.73 0.00e+00 7.941534e-05 7.951603e-05 1.355204e-05 1.049566e-05 1.139546e-04 277.30 -2.00 20.00 -2.00 337.16 0.00e+00 -2.531970e-05 1.252068e-05 9.886115e-07 2.388260e-05 1.976756e-05 277.30 -2.00 20.00 -2.00 345.88 0.00e+00 8.702749e-05 3.597044e-05 1.329753e-05 9.434790e-06 5.551533e-05 277.30 -2.00 20.00 -2.00 344.39 0.00e+00 2.887051e+05 7.253868e+04 3.237159e+04 1.866064e+05 1.041166e+05 259.59 -2.00 11.31 -2.00 351.50 0.00e+00 2.701900e-01 1.108213e-03 2.187500e-03 1.345212e-03 1.401973e-03 228.53 -2.00 3.58 -2.00 330.34 0.00e+00 8.684693e-04 1.518740e-03 6.887299e-04 8.355338e-05 1.594426e-03 277.30 -2.00 20.00 -2.00 328.28 0.00e+00 1.387 0.000 319.50 362.20 4 5.8730e+00 1.2223e-03 9.5303e-03 1.3579e-03 1.8606e-03 2.5084e-03 2.9089e-04 1.5478e-03 2.3830e-04 4.1794e-04 2.7220e-03 5.6253e-04 3.8627e-04 6.9930e-05 8.2223e-04 -6.9944e-04 2.8942e-04 4.1522e-04 1.1718e-05 3.3920e-04 1.7804e-04 4.5295e-04 2.9419e-04 5.0380e-05 6.0735e-04 1.0348e-03 -3.5376e-03 7.7592e-04 1.6528e-04 6.7145e-05 1.1177e-03 1.1706e-04 1.3343e-05 3.3469e-06 5.4716e-07 2.0208e-05 -7.7638e-03 8.2203e-05 -9.0802e-01 8.4684e-02 1.2517e-02 4.4088e-03 1.2420e-01 12 8 8 10 0 0 99.99 22.68 0.17 -0.00776 -0.00632 138 29 1 5 0 356.860 26.41 20.00 22.68 8.01 26.8 947.68 -82 168 8 78 -62 -305 441 -141 -5 15 -73 163 -54 -68 89 -102 251 -237 -124 -106 -84 -171 57 -2 214 152 0 154 -76 -143 9 -256 17 -53 -20 115 71 69 -103 91 -57 -7 -154 265 -137 -104 -31 198 -15 -332 -14 62 38 26 -16 23 -37 334 -74 -73 -21 -106 45 137 63 37 66 34 95 -10 -86 187 -442 72 73 68 -32 55 317 106 5 152 -42 -37 -17 -35 55 23 205 -44 110 -328 -46 -123 116 11 302 -137 -131 -106 -18 -124 189 -27 49 -245 20 15 -124 -56 178 -168 59 -44 -115 -50 246 0 192 84 -24 64 92 -118 -23 -84 -49 37 -40 -224 -48 -99 -171 -165 -74 -73 -148 171 142 -77 5 16 61 9 87 60 -242 -5 5 -121 -41 15 -20 -73 -174 -4 -91 -7 117 135 -133 197 -39 92 8 70 -124 142 -175 238 -39 135 238 160 9 146 -32 161 -83 167 -78 121 122 -7 -11 25 -80 -28 -64 -48 25 -178 223 -72 -23 80 6 1 123 -127 68 40 84 -33 59 -98 -102 -31 -12 -103 61 -40 7 34 17 -181 42 -31 -122 -134 219 83 168 -96 13 -38 -17 77 38 -55 193 -76 -68 -26 -50 -187 20 23 -203 66 55 -111 -94 -69 -101 40 -107 79 115 53 -146 294 31 117 -71 153 -36 -47 -276 -108 -146 -27 -156 109 99 275 -44 87 4 42 -35 -182 269 -88 -3 10 -50 114 -39 -48 63 -70 168 -158 -84 -75 -63 -135 47 -2 188 136 0 136 -68 -128 8 -231 15 -47 -17 101 62 59 -87 76 -48 -6 -130 224 -118 -93 -29 194 -15 -342 -15 65 40 27 -17 23 -35 304 -67 -67 -20 -100 43 127 59 35 64 33 94 -9 -82 181 -435 72 72 67 -32 54 300 98 5 140 -40 -37 -17 -36 57 24 205 -43 112 -342 -50 -133 121 11 268 -115 -112 -97 -18 -121 177 -24 42 -211 18 14 -126 -58 179 -164 57 -44 -118 -53 262 0 202 86 -24 64 94 -127 -26 -96 -57 42 -45 -243 -51 -104 -180 -174 -77 -74 -149 174 150 -85 5 18 67 9 94 66 -274 -6 5 -136 -46 16 -21 -75 -165 -4 -77 -6 105 130 -137 212 -43 102 9 78 -136 153 -181 238 -39 140 252 174 10 164 -36 181 -90 171 -77 120 124 -8 -12 27 -86 -30 -69 -52 27 -183 222 -73 -24 82 6 1 140 -152 83 48 101 -40 69 -111 -114 -34 -13 -111 68 -46 8 39 19 -183 41 -30 -125 -144 245 95 193 -111 15 -46 -20 91 46 -65 231 -91 -82 -32 -60 -224 24 26 -230 74 61 -126 -108 -79 -115 43 -110 77 106 48 -137 280 31 121 -74 153 -34 -40 -226 -85 -115 -22 -131 98 97 288