File name: Pandora169s1_Egbert_20220426_L2Fit_fsus1c16d20210920p1-8.txt File generation date: 20241103T153932.5Z Data description: Level 2 spectral fitting results file Data file version: fsus1c16p1-8 Local principal investigator: Vitali Fioletov Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 169 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora169_OF_v3d20200220.txt Instrument calibration file used: Pandora169s1_CF_v16d20210920.txt Level 1 file used: Pandora169s1_Egbert_20220426_L1_smca1c16d20210920p1-8.txt Full location name: Center for Atmospheric Research Experiments (CARE) - Egbert Short location name: Egbert Country of location: Canada Location latitude [deg]: 44.2300 Location longitude [deg]: -79.7800 Location altitude [m]: 251 Local noon date: 20220426 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 234 379 Nominal wavelengths inside fitting window [nm]: 306.0191 306.1599 306.3007 306.4414 306.5822 306.7229 306.8637 307.0044 307.1451 307.2858 307.4265 307.5672 307.7079 307.8485 307.9892 308.1298 308.2705 308.4111 308.5517 308.6923 308.8329 308.9734 309.1140 309.2546 309.3951 309.5356 309.6762 309.8167 309.9572 310.0976 310.2381 310.3786 310.5190 310.6595 310.7999 310.9403 311.0807 311.2211 311.3615 311.5019 311.6423 311.7826 311.9229 312.0633 312.2036 312.3439 312.4842 312.6245 312.7648 312.9050 313.0453 313.1855 313.3258 313.4660 313.6062 313.7464 313.8866 314.0267 314.1669 314.3071 314.4472 314.5873 314.7274 314.8675 315.0076 315.1477 315.2878 315.4279 315.5679 315.7080 315.8480 315.9880 316.1280 316.2680 316.4080 316.5480 316.6879 316.8279 316.9678 317.1077 317.2477 317.3876 317.5275 317.6673 317.8072 317.9471 318.0869 318.2268 318.3666 318.5064 318.6462 318.7860 318.9258 319.0655 319.2053 319.3451 319.4848 319.6245 319.7642 319.9039 320.0436 320.1833 320.3230 320.4626 320.6023 320.7419 320.8815 321.0211 321.1607 321.3003 321.4399 321.5795 321.7190 321.8586 321.9981 322.1376 322.2771 322.4166 322.5561 322.6956 322.8350 322.9745 323.1139 323.2534 323.3928 323.5322 323.6716 323.8110 323.9503 324.0897 324.2290 324.3684 324.5077 324.6470 324.7863 324.9256 325.0649 325.2041 325.3434 325.4826 325.6219 325.7611 325.9003 326.0395 326.1787 326.3179 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20220426T134825.1Z 8151.575291 204 1 49.49 2 53.72 107.87 55.55 171.99 0.00 1 0.00 1 0 49 1.862e-03 1.056e-03 9.270e-04 5.490e-04 -1.030913e-06 2.198803e-07 1.887623e-08 3.932813e-07 9.110672e-07 229.08 -2.00 3.58 -2.00 320.99 0.00e+00 3.309400e-04 7.399792e-05 9.232355e-06 2.747147e-05 2.351038e-04 277.99 -2.00 20.00 -2.00 320.64 0.00e+00 6.254351e-04 1.025678e-04 4.503887e-06 2.604744e-05 4.010831e-04 277.99 -2.00 20.00 -2.00 321.06 0.00e+00 2.801842e-04 1.365525e-04 2.422644e-05 7.265596e-06 4.203985e-04 277.99 -2.00 20.00 -2.00 320.88 0.00e+00 2.262522e-01 7.589529e-04 4.947399e-05 8.633267e-04 2.448913e-03 223.50 0.80 0.00 0.21 4.21 316.62 0.00e+00 8.858569e-05 3.439359e-05 8.473703e-06 1.265490e-05 6.104625e-05 277.99 -2.00 20.00 -2.00 315.68 0.00e+00 1.685 0.000 303.00 329.40 4 3.4158e+00 2.0574e-03 1.5907e-02 1.9842e-03 7.6416e-03 -5.3596e-03 2.6706e-03 1.6546e-03 2.4370e-04 8.2514e-03 3.1048e-03 1.4913e-03 1.8466e-04 5.5184e-05 4.5782e-03 -4.4826e-03 6.1983e-04 1.0461e-04 2.2494e-05 1.7712e-03 2.5843e-03 4.0902e-04 2.6826e-05 4.0700e-05 1.1017e-03 2.9613e-03 -4.6864e-03 3.6007e-04 2.4033e-05 8.5654e-06 6.6407e-04 3.0853e-04 1.7473e-05 1.7248e-06 7.5550e-07 6.3407e-05 2.7219e-03 4.8301e-05 1.2847e+00 5.5485e-02 1.9424e-03 5.7519e-04 1.6047e-01 11 9 0 11 8 0 99.20 22.63 0.14 0.00272 0.00508 122 26 1 5 0 405.530 26.41 20.00 22.63 13.34 35.7 1018.37 374 645 -2 25 -268 581 125 455 -187 163 -476 -64 -313 71 -27 152 -265 -274 -308 268 -84 456 264 668 -726 226 -168 -239 -150 -39 -250 102 -70 -116 -258 -77 -167 -80 140 -37 198 -97 -36 81 -3 -46 270 206 93 197 -65 -21 81 -47 171 51 109 57 -140 98 -112 -1 -3 10 -16 -48 177 160 124 -27 -39 -117 -122 13 104 -145 -119 -98 117 -58 -15 11 -40 -38 -160 -182 -232 -221 8 151 149 174 53 -57 -121 -31 -14 -33 -208 15 40 123 -42 11 94 119 16 44 10 61 15 -33 -35 19 59 109 10 -48 -108 71 99 66 -93 -75 -31 -101 -40 -71 -12 68 16 -4 11 -70 60 62 -103 -49 10 -1 105 9 2 20 -28 -23 77 145 0 6 -64 147 35 136 -61 56 -170 -24 -112 26 -10 56 -101 -110 -127 111 -34 172 102 260 -287 94 -74 -105 -64 -17 -122 55 -41 -73 -172 -52 -111 -53 96 -25 130 -63 -23 53 -2 -32 198 151 69 149 -49 -16 61 -36 138 42 92 49 -119 80 -89 -1 -2 9 -14 -44 165 141 104 -22 -31 -93 -102 11 96 -140 -121 -101 125 -65 -16 12 -45 -42 -166 -180 -218 -214 8 164 171 205 63 -66 -132 -33 -15 -37 -241 18 49 153 -54 15 126 156 21 53 11 72 18 -41 -46 24 77 138 12 -59 -127 83 114 79 -115 -95 -40 -131 -54 -97 -17 98 23 -6 16 -100 83 87 -142 -71 14 -2 171 15 3 34 -48 -40 SS 20220426T135802.6Z 8151.581975 207 1 49.27 2 52.08 109.97 55.32 174.78 0.00 1 0.00 1 0 49 2.796e-03 1.842e-03 9.301e-04 5.787e-04 -2.470459e-06 2.319264e-07 3.060096e-08 3.932846e-07 1.370219e-06 229.08 -2.00 3.58 -2.00 320.89 0.00e+00 7.457999e-04 7.787200e-05 1.043750e-05 2.746139e-05 3.539781e-04 277.99 -2.00 20.00 -2.00 320.53 0.00e+00 1.227423e-03 1.080531e-04 1.283973e-05 2.603344e-05 6.015518e-04 277.99 -2.00 20.00 -2.00 320.99 0.00e+00 -1.095484e-04 1.431705e-04 1.895361e-05 7.256546e-06 6.313876e-04 277.99 -2.00 20.00 -2.00 320.79 0.00e+00 2.215470e-01 7.876278e-04 1.025283e-04 8.631799e-04 3.666832e-03 219.55 0.84 0.00 0.21 6.32 316.42 0.00e+00 9.074850e-05 3.487757e-05 4.443720e-05 1.265176e-05 9.170763e-05 277.99 -2.00 20.00 -2.00 315.51 0.00e+00 1.624 0.000 303.00 329.40 4 3.6052e+00 2.0861e-03 1.5327e-02 1.9843e-03 1.1473e-02 -3.5146e-03 2.7109e-03 1.7308e-03 2.4309e-04 1.2375e-02 5.8368e-03 1.5340e-03 3.9920e-04 5.5101e-05 6.8778e-03 -8.4796e-03 6.3557e-04 1.6183e-04 2.1568e-05 2.6479e-03 4.5276e-03 4.2470e-04 4.7900e-05 3.8849e-05 1.6419e-03 2.6446e-03 -1.0699e-02 3.7376e-04 3.6984e-05 8.8584e-06 1.0747e-03 3.5749e-04 1.8491e-05 2.2108e-06 7.5090e-07 9.4129e-05 7.4817e-03 4.6686e-05 2.6881e+00 5.8622e-02 3.9388e-03 5.7415e-04 2.4418e-01 12 8 8 10 0 0 98.56 22.61 0.15 0.00748 0.01021 95 20 1 5 0 518.520 26.32 19.99 22.61 14.52 35.5 1023.73 1366 510 715 412 378 327 371 244 253 -314 -477 -610 -333 -285 -205 -46 -60 -329 -525 -63 -6 197 628 722 -655 -18 -526 -118 -127 21 0 -105 -292 -291 -279 -281 -93 -29 71 251 179 -100 -180 259 162 297 376 394 40 145 -127 32 20 305 254 330 177 121 -270 48 -129 -201 58 86 92 -18 296 263 126 95 -271 -379 -250 -165 -20 -108 -211 -77 72 -57 -19 -83 -130 -240 -246 -399 -509 -362 82 297 428 306 -59 -73 -60 -43 -47 -108 -382 -23 83 22 126 142 186 181 111 82 41 156 -2 -74 -76 98 263 204 55 -118 -148 77 138 84 -106 -44 -60 -146 -241 -109 -147 50 40 24 -173 38 115 96 -50 -165 -108 -38 118 117 65 67 -114 16 299 123 183 109 101 88 111 81 86 -114 -177 -233 -130 -113 -82 -18 -25 -136 -224 -27 -2 81 249 291 -282 -8 -236 -53 -55 10 0 -57 -176 -194 -187 -192 -64 -20 49 170 118 -68 -121 177 112 217 274 297 30 112 -100 25 15 240 203 281 152 105 -234 39 -105 -162 51 80 86 -17 269 234 108 77 -209 -298 -206 -146 -19 -105 -216 -79 77 -64 -22 -96 -145 -261 -255 -398 -485 -354 84 321 486 357 -69 -84 -68 -46 -51 -120 -442 -28 101 28 161 185 244 238 141 101 49 182 -2 -91 -96 126 335 261 68 -142 -177 88 157 100 -129 -55 -77 -191 -317 -145 -206 71 57 35 -246 53 159 131 -69 -236 -162 -59 191 195 110 114 -194 27 SS 20220426T140333.5Z 8151.585805 211 1 30.28 2 51.16 111.21 55.23 176.40 0.00 1 0.00 1 0 49 3.604e-03 2.409e-03 1.193e-03 7.550e-04 -3.114464e-06 3.034469e-07 4.924756e-08 3.932858e-07 1.766566e-06 229.08 -2.00 3.58 -2.00 320.86 0.00e+00 1.025023e-03 1.015971e-04 3.872597e-06 2.745410e-05 4.568599e-04 277.99 -2.00 20.00 -2.00 320.48 0.00e+00 1.554988e-03 1.409943e-04 1.782904e-05 2.603263e-05 7.745563e-04 277.99 -2.00 20.00 -2.00 320.97 0.00e+00 -8.258661e-05 1.863050e-04 3.095788e-05 7.260306e-06 8.137063e-04 277.99 -2.00 20.00 -2.00 320.75 0.00e+00 2.198310e-01 1.014312e-03 1.485668e-04 8.631937e-04 4.715747e-03 216.75 1.09 0.00 0.22 8.14 316.34 0.00e+00 8.141473e-06 4.474149e-05 6.566156e-05 1.265216e-05 1.182439e-04 277.99 -2.00 20.00 -2.00 315.43 0.00e+00 1.591 0.000 303.00 329.40 4 3.6734e+00 2.6518e-03 1.5027e-02 1.9840e-03 1.4781e-02 -1.1865e-03 3.4364e-03 1.9507e-03 2.4293e-04 1.5927e-02 2.7599e-03 1.9646e-03 5.0698e-04 5.4709e-05 8.8637e-03 -1.1657e-02 8.1893e-04 1.4579e-04 2.1281e-05 3.4039e-03 6.8874e-03 5.4931e-04 6.0282e-05 3.8460e-05 2.1059e-03 2.5694e-03 -1.5114e-02 4.8645e-04 5.9388e-05 9.2179e-06 1.4576e-03 5.3646e-04 2.4503e-05 2.7104e-06 7.5263e-07 1.2045e-04 1.1698e-02 6.8392e-05 3.9843e+00 7.6503e-02 2.8221e-03 6.0531e-04 3.1700e-01 12 9 9 12 1 1 99.70 22.59 0.19 0.01170 0.01579 54 19 1 5 0 547.260 26.32 19.99 22.59 14.96 35.5 1027.28 932 831 966 1260 513 845 229 180 -186 -469 -291 -485 -496 -615 -182 36 -348 -545 -897 -246 -37 564 744 1004 -891 -185 -208 -562 225 213 73 -420 25 -225 -364 -338 -76 -122 429 55 69 -46 79 160 304 140 513 326 224 16 -100 -167 90 265 441 292 346 -51 -310 -113 -226 -152 -131 145 148 12 272 414 319 -75 -374 -411 -178 83 0 -121 -262 36 82 -10 -140 12 -131 -350 -392 -447 -768 -482 60 324 478 286 8 -99 -81 -11 -146 -271 -472 -113 247 145 103 250 208 256 342 11 38 138 -101 -68 -139 168 312 415 -18 -303 -110 81 122 114 -163 -79 -25 -174 -267 -175 -138 8 78 25 -153 -24 146 162 -159 -237 -36 -6 169 171 -9 38 -54 -16 209 203 251 337 140 246 70 61 -68 -171 -108 -185 -194 -246 -73 14 -146 -239 -406 -111 -16 232 297 405 -384 -83 -92 -251 104 99 38 -243 16 -149 -253 -229 -52 -83 304 39 47 -30 52 109 217 101 384 254 170 13 -77 -127 69 206 361 244 303 -45 -263 -93 -181 -125 -113 131 140 11 251 374 277 -60 -297 -332 -150 75 0 -119 -262 38 88 -12 -157 14 -147 -370 -410 -433 -744 -479 62 355 548 335 9 -115 -88 -12 -159 -304 -549 -136 302 180 133 324 272 336 435 14 44 162 -119 -81 -177 214 398 531 -23 -367 -132 94 140 136 -199 -99 -32 -222 -351 -233 -194 11 111 35 -217 -34 202 222 -222 -339 -54 -9 273 284 -15 63 -91 -26 SS 20220426T140842.7Z 8151.589383 214 1 49.52 2 50.30 112.38 55.16 177.90 0.00 1 0.00 1 0 49 3.891e-03 2.715e-03 8.914e-04 5.594e-04 -3.676981e-06 2.249442e-07 5.304043e-08 3.932933e-07 1.908742e-06 229.08 -2.00 3.58 -2.00 320.90 0.00e+00 1.017991e-03 7.542607e-05 7.112728e-06 2.745853e-05 4.937416e-04 277.99 -2.00 20.00 -2.00 320.57 0.00e+00 2.008364e-03 1.046042e-04 1.856847e-05 2.603171e-05 8.361142e-04 277.99 -2.00 20.00 -2.00 321.00 0.00e+00 -4.073125e-04 1.392824e-04 2.355197e-05 7.266391e-06 8.785761e-04 277.99 -2.00 20.00 -2.00 320.80 0.00e+00 2.186811e-01 7.548699e-04 1.379549e-04 8.632008e-04 5.083456e-03 216.08 0.81 0.00 0.22 8.79 316.37 0.00e+00 6.760483e-05 3.348777e-05 6.348954e-05 1.265246e-05 1.277462e-04 277.99 -2.00 20.00 -2.00 315.47 0.00e+00 1.562 0.000 303.00 329.40 4 3.5995e+00 1.9552e-03 1.4758e-02 1.9839e-03 1.5958e-02 3.4232e-04 2.5514e-03 1.8657e-03 2.4406e-04 1.7184e-02 -1.0238e-03 1.4597e-03 5.1149e-04 5.5122e-05 9.5660e-03 -1.1255e-02 6.0518e-04 1.7197e-04 2.1322e-05 3.6622e-03 7.7438e-03 4.0646e-04 4.5746e-05 3.8613e-05 2.2677e-03 2.8650e-03 -1.6522e-02 3.6566e-04 6.2004e-05 9.3173e-06 1.6073e-03 6.0063e-04 1.8440e-05 2.7081e-06 7.4784e-07 1.2944e-04 1.3887e-02 4.1516e-05 4.8966e+00 5.7061e-02 3.1839e-03 6.1678e-04 3.4295e-01 12 8 8 10 0 0 99.71 22.57 0.18 0.01389 0.01847 123 26 1 5 0 402.560 26.32 19.99 22.57 15.34 35.4 1028.63 1444 1251 1057 566 793 735 432 176 -73 -468 -612 -728 -428 -372 -4 -83 -316 -750 -604 -81 -216 510 670 783 -809 -259 -339 -411 247 343 -53 -166 -176 -370 -440 -317 -255 -162 374 170 183 -91 -149 58 346 182 467 552 316 54 -83 -94 -88 254 587 402 222 40 -216 -66 -289 -345 44 179 65 108 201 532 351 253 -494 -508 -228 -130 -13 -139 -394 92 152 25 -26 -132 -129 -328 -544 -593 -819 -456 66 334 650 482 -46 -106 -129 -45 -165 -216 -527 -156 187 212 107 152 322 294 219 95 99 72 -42 -294 -107 68 417 511 -12 -302 -177 39 206 145 -153 -59 -60 -236 -298 -161 -59 66 135 -13 -284 -71 260 169 -160 -154 -82 -12 192 146 -12 33 -75 -4 335 294 265 147 210 207 135 57 -26 -174 -233 -284 -170 -151 -2 -34 -127 -315 -261 -35 -91 213 272 322 -354 -112 -152 -185 109 162 -27 -91 -111 -245 -305 -214 -174 -110 264 118 124 -61 -99 40 247 130 348 425 247 41 -63 -74 -70 197 476 332 192 35 -179 -53 -229 -281 38 166 60 101 182 472 300 208 -389 -407 -190 -116 -12 -139 -401 95 167 27 -29 -150 -142 -351 -558 -587 -780 -446 67 358 726 570 -55 -119 -143 -48 -177 -246 -620 -184 231 264 139 198 421 386 279 113 115 83 -50 -357 -137 87 533 658 -15 -369 -207 46 239 169 -189 -74 -78 -302 -393 -215 -83 92 192 -19 -403 -101 362 232 -225 -221 -123 -18 308 240 -21 56 -129 -6 SS 20220426T141337.4Z 8151.592794 217 1 49.38 2 49.49 113.53 55.12 179.34 0.00 1 0.00 1 0 49 2.723e-03 1.946e-03 7.462e-04 4.848e-04 -2.889860e-06 1.954851e-07 3.860076e-08 3.932813e-07 1.335596e-06 229.08 -2.00 3.58 -2.00 320.79 0.00e+00 8.198153e-04 6.495909e-05 7.377501e-06 2.744844e-05 3.461045e-04 277.99 -2.00 20.00 -2.00 320.41 0.00e+00 1.332906e-03 9.064066e-05 1.210552e-05 2.602992e-05 5.852053e-04 277.99 -2.00 20.00 -2.00 320.93 0.00e+00 6.698710e-05 1.184823e-04 1.361928e-05 7.258618e-06 6.150289e-04 277.99 -2.00 20.00 -2.00 320.70 0.00e+00 2.116134e-01 6.497792e-04 7.448302e-05 8.630926e-04 3.558523e-03 218.50 0.73 0.00 0.23 6.14 316.23 0.00e+00 6.010043e-05 2.810018e-05 4.075712e-05 1.265170e-05 8.930817e-05 277.99 -2.00 20.00 -2.00 315.32 0.00e+00 1.536 0.000 303.00 329.40 4 3.3525e+00 1.7274e-03 1.4505e-02 1.9837e-03 1.1165e-02 -4.2612e-03 2.2210e-03 1.6221e-03 2.4181e-04 1.2027e-02 2.1967e-03 1.2636e-03 3.4266e-04 5.4344e-05 6.7052e-03 -9.1136e-03 5.1521e-04 1.3342e-04 2.0361e-05 2.5575e-03 5.2637e-03 3.4678e-04 2.6185e-05 3.7209e-05 1.5822e-03 3.7590e-03 -1.2444e-02 3.2216e-04 5.0035e-05 9.1152e-06 1.1472e-03 4.1361e-04 1.5666e-05 2.2395e-06 7.5058e-07 9.1089e-05 9.8892e-03 3.1097e-05 3.4667e+00 4.9764e-02 2.3171e-03 6.2901e-04 2.4358e-01 12 9 8 11 8 0 99.26 22.57 0.15 0.00989 0.01305 136 29 1 5 0 363.030 26.32 20.00 22.57 15.57 35.5 1030.47 600 696 629 684 460 357 372 482 103 -123 -569 -207 -631 -171 -85 -21 -257 -554 -488 6 -33 406 416 710 -346 -152 -417 -395 23 237 -214 -114 -167 -337 -549 -195 -47 -243 170 153 84 8 -47 97 81 154 381 372 224 204 51 -57 13 268 391 327 201 -22 -197 11 -158 -226 154 129 134 -95 207 368 287 102 -372 -433 -210 -78 122 -143 -191 30 31 29 -21 -55 -81 -254 -337 -424 -570 -387 28 283 379 285 -4 -43 -98 -85 -106 -267 -269 -117 166 96 -1 66 202 224 176 94 8 116 -78 -104 -117 92 344 284 -11 -265 -39 99 202 134 -99 -44 -43 -155 -249 -115 1 37 94 14 -213 -52 86 138 -48 -29 -80 -48 58 120 -11 12 -21 -7 149 176 170 190 130 107 117 167 39 -46 -219 -82 -256 -70 -35 -9 -111 -250 -226 3 -15 172 170 293 -151 -70 -200 -190 11 112 -115 -67 -107 -229 -375 -136 -33 -171 118 105 59 6 -32 67 57 113 292 282 174 159 40 -45 10 213 327 280 173 -19 -170 9 -129 -188 134 118 125 -89 195 325 243 82 -298 -352 -178 -71 117 -143 -193 32 34 32 -23 -63 -90 -274 -345 -417 -557 -374 28 303 425 328 -5 -49 -108 -93 -113 -304 -318 -139 206 121 -1 88 269 290 220 112 10 133 -92 -126 -146 120 443 357 -14 -325 -46 116 233 155 -119 -55 -53 -199 -330 -154 2 53 131 20 -306 -73 117 191 -65 -41 -117 -74 93 196 -18 19 -34 -11 SS 20220426T150208.2Z 8151.626484 251 1 49.19 2 41.94 126.22 55.88 193.50 0.00 1 0.00 1 0 49 3.241e-03 1.862e-03 1.902e-03 1.209e-03 -1.646117e-06 4.885791e-07 2.868720e-08 3.932627e-07 1.591121e-06 229.08 -2.00 3.58 -2.00 320.80 0.00e+00 5.182823e-04 1.615741e-04 8.503384e-06 2.745741e-05 4.144438e-04 278.00 -2.00 20.00 -2.00 320.44 0.00e+00 4.783162e-04 2.293700e-04 4.628038e-06 2.602310e-05 6.979660e-04 278.00 -2.00 20.00 -2.00 320.93 0.00e+00 2.475228e-04 2.930931e-04 4.277178e-05 7.253846e-06 7.321105e-04 278.00 -2.00 20.00 -2.00 320.71 0.00e+00 1.862812e-01 1.626205e-03 1.123846e-04 8.630248e-04 4.220298e-03 224.29 2.12 0.00 0.26 7.28 316.30 0.00e+00 9.882557e-05 7.106448e-05 1.049503e-05 1.265206e-05 1.060313e-04 278.00 -2.00 20.00 -2.00 315.38 0.00e+00 1.343 0.000 303.00 329.40 4 5.2049e+00 4.5797e-03 1.2676e-02 1.9836e-03 1.3320e-02 1.9779e-02 5.7629e-03 1.4308e-03 2.4066e-04 1.4273e-02 4.0359e-03 3.2239e-03 2.0823e-04 5.5193e-05 8.0085e-03 -4.3206e-03 1.2319e-03 7.8705e-05 2.0527e-05 2.9769e-03 1.9598e-03 8.6249e-04 3.7463e-05 3.7783e-05 1.8609e-03 7.1634e-04 -2.2207e-03 9.7864e-04 4.5417e-05 1.0519e-05 1.5678e-03 5.4175e-04 3.8713e-05 1.7614e-06 7.6486e-07 1.1137e-04 -4.4952e-04 6.8505e-05 8.9374e-01 1.3574e-01 1.1123e-03 6.6471e-04 3.1018e-01 12 8 8 10 0 0 99.95 22.49 0.01 -0.00045 0.00368 58 12 1 5 0 847.860 26.21 20.01 22.49 14.31 35.7 1023.02 675 -150 785 -8 416 -223 -47 -38 -177 -15 -360 -272 114 -305 481 24 -205 2 -326 -271 307 720 339 813 -2466 262 -258 -63 1081 240 242 7 -206 7 -178 -273 -101 -221 140 -210 381 39 -196 222 -56 103 193 532 -2 184 47 -139 21 178 255 -155 237 -21 -246 165 -213 -144 -321 -71 -28 -207 -16 81 -95 159 -289 -200 -103 -110 321 -75 210 34 -28 96 130 -166 34 -161 -1 187 -66 -246 133 66 89 33 -61 236 -1 -125 -179 -123 -121 231 80 -109 26 -22 6 293 -102 -33 -59 54 -166 -24 -104 221 62 0 -85 78 -222 132 41 -80 -38 -172 -83 221 -132 -34 73 97 57 24 17 -180 57 -28 -237 -4 66 -39 235 91 125 -68 -135 -45 155 -37 207 -2 113 -64 -15 -13 -64 -6 -138 -107 45 -124 196 10 -86 1 -146 -122 134 296 135 324 -1050 114 -116 -28 471 110 122 4 -129 5 -125 -195 -73 -159 100 -149 262 27 -132 150 -39 75 145 409 -2 145 37 -109 16 142 209 -134 210 -19 -213 135 -170 -117 -277 -65 -27 -198 -15 73 -81 127 -222 -154 -84 -97 300 -74 213 36 -31 109 150 -193 39 -176 -1 183 -63 -236 134 70 101 39 -72 270 -1 -134 -192 -138 -142 278 99 -138 33 -30 8 385 -129 -40 -68 62 -193 -29 -131 285 80 1 -105 94 -259 150 46 -92 -45 -213 -104 280 -171 -45 100 136 82 35 24 -251 79 -38 -327 -6 97 -60 376 150 210 -116 -228 -76