File name: Pandora75s1_EssexMD_20250126_L2Fit_ffuh5c3d20230525p1-8.txt File generation date: 20250305T073208.6Z Data description: Level 2 spectral fitting results file Data file version: ffuh5c3p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 75 Spectrometer number: 1 Processing software version used: BlickP v1.8.74 Instrument operation file used: Pandora75_OF_v3d20220127.txt Instrument calibration file used: Pandora75s1_CF_v3d20230525.txt Level 1 file used: Pandora75s1_EssexMD_20250126_L1_smca1c3d20230525p1-8.txt Full location name: MDE Essex Monitoring Site Short location name: EssexMD Country of location: United States Location latitude [deg]: 39.3109 Location longitude [deg]: -76.4745 Location altitude [m]: 12 Local noon date: 20250126 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OoB session based on session 2 First and last pixel inside fitting window: 364 584 Nominal wavelengths inside fitting window [nm]: 328.5901 328.7293 328.8686 329.0078 329.1471 329.2863 329.4255 329.5647 329.7039 329.8430 329.9822 330.1213 330.2605 330.3996 330.5387 330.6778 330.8169 330.9560 331.0951 331.2341 331.3732 331.5122 331.6512 331.7902 331.9292 332.0682 332.2072 332.3461 332.4851 332.6240 332.7629 332.9019 333.0408 333.1796 333.3185 333.4574 333.5962 333.7351 333.8739 334.0127 334.1515 334.2903 334.4291 334.5679 334.7066 334.8454 334.9841 335.1228 335.2616 335.4003 335.5389 335.6776 335.8163 335.9549 336.0936 336.2322 336.3708 336.5094 336.6480 336.7866 336.9252 337.0637 337.2023 337.3408 337.4793 337.6178 337.7563 337.8948 338.0333 338.1717 338.3102 338.4486 338.5870 338.7254 338.8638 339.0022 339.1406 339.2790 339.4173 339.5557 339.6940 339.8323 339.9706 340.1089 340.2472 340.3854 340.5237 340.6619 340.8002 340.9384 341.0766 341.2148 341.3530 341.4911 341.6293 341.7674 341.9056 342.0437 342.1818 342.3199 342.4580 342.5960 342.7341 342.8721 343.0102 343.1482 343.2862 343.4242 343.5622 343.7002 343.8381 343.9761 344.1140 344.2519 344.3899 344.5278 344.6656 344.8035 344.9414 345.0792 345.2171 345.3549 345.4927 345.6305 345.7683 345.9061 346.0438 346.1816 346.3193 346.4571 346.5948 346.7325 346.8702 347.0079 347.1455 347.2832 347.4208 347.5584 347.6961 347.8337 347.9713 348.1088 348.2464 348.3840 348.5215 348.6590 348.7965 348.9340 349.0715 349.2090 349.3465 349.4839 349.6214 349.7588 349.8962 350.0336 350.1710 350.3084 350.4458 350.5831 350.7205 350.8578 350.9951 351.1324 351.2697 351.4070 351.5443 351.6815 351.8188 351.9560 352.0932 352.2304 352.3676 352.5048 352.6420 352.7791 352.9163 353.0534 353.1905 353.3276 353.4647 353.6018 353.7388 353.8759 354.0129 354.1500 354.2870 354.4240 354.5610 354.6979 354.8349 354.9719 355.1088 355.2457 355.3826 355.5195 355.6564 355.7933 355.9302 356.0670 356.2039 356.3407 356.4775 356.6143 356.7511 356.8879 357.0246 357.1614 357.2981 357.4348 357.5715 357.7082 357.8449 357.9816 358.1183 358.2549 358.3915 358.5282 358.6648 358.8014 358.9379 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Formaldehyde effective temperature [K] Column 28: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 45: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Oxygen dimer effective temperature [K] Column 50: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Ozone effective temperature [K] Column 61: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Fitted Ring spectrum, -9e99=no fitting done or fitting not successful Column 67: Independent uncertainty of fitted Ring spectrum, -9=fitting not successful Column 68: Structured uncertainty of fitted Ring spectrum, -9=fitting not successful Column 69: Common uncertainty of fitted Ring spectrum, -9=fitting not successful Column 70: rms-based uncertainty of fitted Ring spectrum, -9=fitting not successful Column 71: Effective Ring fitting wavelength [nm], -9=fitting not done or not successful Column 72: Diffuse correction applied before fitting at effective Ring fitting wavelength [%], 0=no diffuse correction applied, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 73: Lower limit used for wavelength scaling [nm] Column 74: Upper limit used for wavelength scaling [nm] Column 75: Order of smoothing polynomial Column 76: Smoothing polynomial coefficient, order 0 Column 77: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 78: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 79: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 80: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 81: Smoothing polynomial coefficient, order 1 Column 82: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 83: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 84: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 85: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 86: Smoothing polynomial coefficient, order 2 Column 87: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 88: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 89: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 90: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 91: Smoothing polynomial coefficient, order 3 Column 92: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 93: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 94: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 95: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 96: Smoothing polynomial coefficient, order 4 Column 97: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 98: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 99: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 100: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 101: Mean value of measured data inside fitting window [same units as measurements] Column 102: Offset polynomial coefficient, order 0 Column 103: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 104: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 105: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 106: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 107: Offset polynomial coefficient, order 1 Column 108: Independent uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 109: Structured uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 110: Common uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 111: rms-based uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 112: Wavelength change polynomial coefficient, order 0 Column 113: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 114: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 115: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 116: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 117: Wavelength change polynomial coefficient, order 1 Column 118: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 119: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 120: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 121: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 122: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 123: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 124: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 125: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 126: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 127: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 128: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 129: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 130: Atmospheric variability [%], 999=no atmospheric variability was determined Column 131: Wavelength effective temperature [°C], 999=no effective temperature given Column 132: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 133: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 134: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 135: Number of bright count cycles Column 136: Number of dark count cycles Column 137: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 138: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 139: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 140: Integration time [ms] Column 141: Temperature at electronics board [°C], 999=no temperature signal Column 142: Spectrometer control temperature [°C], 999=no temperature signal Column 143: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 144: Temperature in head sensor [°C], 999=no temperature signal Column 145: Humidity in head sensor [%], -9=no humidity signal Column 146: Pressure in head sensor [hPa], -9=no pressure signal Columns 147-367: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 368-588: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------