File name: Pandora144s1_Eureka-PEARL_20200802_L2Fit_fwvt1c4d20190120p1-8.txt File generation date: 20241125T231626.2Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c4p1-8 Local principal investigator: Vitali Fioletov Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 144 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora144_of_v3d20180302.txt Instrument calibration file used: Pandora144s1_CF_v4d20190120.txt Level 1 file used: Pandora144s1_Eureka-PEARL_20200802_L1_smca1c4d20190120p1-8.txt Full location name: Polar Environment Atmospheric Research Laboratory (PEARL) Short location name: Eureka-PEARL Country of location: Canada Location latitude [deg]: 80.0533 Location longitude [deg]: -86.4160 Location altitude [m]: 617 Local noon date: 20200802 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1639 1789 Nominal wavelengths inside fitting window [nm]: 492.0500 492.1708 492.2917 492.4125 492.5333 492.6541 492.7748 492.8956 493.0163 493.1371 493.2578 493.3784 493.4991 493.6198 493.7404 493.8610 493.9816 494.1022 494.2228 494.3433 494.4639 494.5844 494.7049 494.8254 494.9458 495.0663 495.1867 495.3072 495.4276 495.5479 495.6683 495.7887 495.9090 496.0293 496.1496 496.2699 496.3902 496.5104 496.6306 496.7508 496.8710 496.9912 497.1114 497.2315 497.3517 497.4718 497.5919 497.7120 497.8320 497.9521 498.0721 498.1921 498.3121 498.4321 498.5520 498.6720 498.7919 498.9118 499.0317 499.1516 499.2714 499.3913 499.5111 499.6309 499.7507 499.8705 499.9902 500.1100 500.2297 500.3494 500.4691 500.5887 500.7084 500.8280 500.9476 501.0672 501.1868 501.3064 501.4259 501.5455 501.6650 501.7845 501.9040 502.0234 502.1429 502.2623 502.3817 502.5011 502.6205 502.7398 502.8592 502.9785 503.0978 503.2171 503.3364 503.4556 503.5749 503.6941 503.8133 503.9325 504.0516 504.1708 504.2899 504.4090 504.5281 504.6472 504.7663 504.8853 505.0044 505.1234 505.2424 505.3614 505.4803 505.5993 505.7182 505.8371 505.9560 506.0748 506.1937 506.3125 506.4314 506.5502 506.6689 506.7877 506.9065 507.0252 507.1439 507.2626 507.3813 507.5000 507.6186 507.7372 507.8558 507.9744 508.0930 508.2116 508.3301 508.4486 508.5671 508.6856 508.8041 508.9225 509.0410 509.1594 509.2778 509.3962 509.5145 509.6329 509.7512 509.8695 509.9878 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Columns 98-248: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 249-399: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SO 20200802T181015.4Z 7519.757122 330 1 34.71 2 62.60 184.93 123.12 16.53 0.00 1 0.00 1 0 15 2.462e-03 2.456e-03 1.413e-03 1.410e-03 9.977872e+02 7.601302e+01 6.335178e+01 -6.000000e+00 1.280031e+02 269.44 -2.00 20.00 -2.00 505.27 0.00e+00 5.819704e-04 3.713247e-05 3.470743e-05 -6.000000e+00 6.633130e-05 269.44 -2.00 20.00 -2.00 500.41 0.00e+00 1.527596e-01 2.801817e-02 1.247597e-02 -6.000000e+00 4.916943e-02 234.77 -2.00 5.57 -2.00 502.02 0.00e+00 2.161 0.000 489.00 513.00 1 7.6335e+00 2.1288e-03 3.1350e-03 -6.0000e+00 3.7481e-03 -4.6011e-04 5.5875e-04 2.9129e-04 -6.0000e+00 9.7921e-04 6.9975e-04 1.5231e-04 1.3336e-04 1.4949e-05 -6.0000e+00 2.3760e-04 1.9674e-02 -4.1469e-04 10 0 0 10 0 0 79.61 20.03 0.82 0.01967 0.02073 9 2 1 7 0 3850.513 23.53 14.99 20.03 -450 -397 -213 -160 309 580 290 318 41 408 96 21 -10 41 -42 8 84 20 -57 -130 -119 134 194 -60 305 102 246 -76 -107 117 -75 -364 -61 266 -634 -129 393 -87 -42 -61 68 -47 -4 194 224 -63 226 -198 299 -559 54 -312 -385 -608 -16 -393 -192 -240 229 276 410 250 249 118 367 103 -79 216 -89 34 -114 -425 -369 -291 -24 -208 -77 168 4 -106 -23 -551 -416 -99 6 -317 -316 77 280 -186 -136 236 -110 -198 46 199 -138 -102 -410 -419 206 -133 227 -165 -194 -111 -182 -141 60 134 -88 273 201 382 335 561 57 -105 70 209 -136 -43 335 -193 -123 -13 -40 102 279 417 -94 38 457 -203 23 234 166 -343 60 49 -59 33 390 311 166 -322 -303 -213 43 -52 -228 -425 -377 -207 -161 319 612 312 348 42 443 103 22 -11 42 -43 8 86 21 -58 -135 -124 140 202 -62 319 107 257 -79 -109 123 -76 -371 -63 265 -660 -136 411 -91 -43 -62 69 -47 -4 201 234 -66 237 -206 305 -563 52 -313 -379 -599 -16 -384 -192 -245 233 281 416 255 255 121 374 104 -78 212 -86 33 -108 -403 -352 -281 -23 -204 -74 159 3 -98 -21 -519 -395 -94 6 -309 -311 76 274 -184 -134 235 -112 -204 47 202 -138 -100 -391 -390 188 -123 213 -161 -196 -113 -185 -140 59 131 -87 274 205 395 331 556 57 -106 70 206 -133 -43 333 -193 -124 -13 -40 103 280 417 -94 38 443 -195 22 222 160 -324 58 47 -58 32 383 308 165 -321 -298 -204 40 -51 -211 SO 20200802T181541.4Z 7519.760896 333 1 34.89 2 62.62 186.39 123.05 17.96 0.00 1 0.00 1 0 15 2.446e-03 2.437e-03 1.296e-03 1.292e-03 7.990271e+02 6.853457e+01 5.178463e+01 -6.000000e+00 1.271662e+02 269.44 -2.00 20.00 -2.00 505.24 0.00e+00 6.375357e-04 3.398921e-05 3.783622e-05 -6.000000e+00 6.589723e-05 269.44 -2.00 20.00 -2.00 500.40 0.00e+00 1.534605e-01 2.561639e-02 1.059583e-02 -6.000000e+00 4.885234e-02 234.77 -2.00 5.57 -2.00 501.99 0.00e+00 2.163 0.000 489.00 513.00 1 7.4703e+00 1.9499e-03 3.1121e-03 -6.0000e+00 3.7238e-03 -1.1584e-03 5.1132e-04 2.5381e-04 -6.0000e+00 9.7302e-04 8.2322e-04 5.6994e-04 1.2270e-04 1.4995e-05 -6.0000e+00 2.3604e-04 2.2054e-02 -4.3868e-04 10 0 0 10 0 0 75.91 20.04 0.82 0.02205 0.02601 10 2 1 7 0 3488.455 23.53 15.00 20.04 -220 -108 -389 133 -16 429 310 323 103 281 317 -81 -67 -45 60 -262 16 -279 -102 -58 46 -150 334 397 291 328 111 58 -427 176 -151 -308 -346 186 -242 17 400 157 188 -308 51 -153 261 -89 102 153 137 14 160 -328 -369 -206 -411 -156 -587 -428 -226 -49 -32 339 169 394 209 -102 134 183 210 -10 -275 -91 -163 -102 -9 73 21 -142 -140 251 -187 -148 -340 -498 -279 97 50 -277 -73 -80 317 -585 267 -217 80 -192 112 -97 55 89 -401 -383 -3 -91 -7 45 -406 -100 -88 -113 -19 74 22 -136 284 234 301 272 424 -15 155 170 -165 159 294 6 -317 134 -193 271 263 643 -113 83 278 -27 -159 242 361 -197 127 -13 178 -18 639 133 -165 -110 -462 -235 5 -264 -230 -209 -103 -383 135 -17 458 319 337 108 292 323 -82 -70 -46 62 -269 16 -280 -104 -61 49 -158 351 417 308 348 117 61 -441 176 -156 -316 -340 187 -253 18 422 164 194 -316 52 -157 269 -93 108 163 145 14 165 -333 -364 -197 -409 -154 -562 -422 -229 -50 -33 348 174 405 216 -106 139 186 211 -10 -270 -88 -156 -98 -8 71 21 -141 -136 240 -177 -139 -321 -474 -267 94 48 -273 -72 -79 314 -585 267 -220 82 -200 116 -100 55 88 -387 -361 -2 -85 -7 45 -415 -97 -86 -114 -19 73 22 -131 278 232 301 274 428 -16 157 170 -162 153 281 5 -306 130 -187 261 253 615 -109 79 273 -26 -153 233 334 -188 123 -13 176 -18 633 133 -166 -110 -461 -228 5 -247 -214 SO 20200802T183415.7Z 7519.773793 345 1 33.43 2 62.75 191.37 122.76 22.82 0.00 1 0.00 1 0 15 2.509e-03 2.512e-03 1.426e-03 1.422e-03 7.039017e+02 7.524420e+01 4.122360e+01 -6.000000e+00 1.304558e+02 269.44 -2.00 20.00 -2.00 505.23 0.00e+00 5.951204e-04 3.734469e-05 3.496813e-05 -6.000000e+00 6.760256e-05 269.44 -2.00 20.00 -2.00 500.38 0.00e+00 1.618651e-01 2.817034e-02 1.025311e-02 -6.000000e+00 5.011299e-02 234.77 -2.00 5.57 -2.00 501.98 0.00e+00 2.172 0.000 489.00 513.00 1 7.6106e+00 2.1419e-03 3.0954e-03 -6.0000e+00 3.8200e-03 1.7129e-03 5.6323e-04 2.4477e-04 -6.0000e+00 9.9804e-04 7.1477e-04 5.8479e-04 1.3460e-04 1.3123e-05 -6.0000e+00 2.4216e-04 2.3543e-02 -4.4013e-04 10 0 0 10 0 0 82.75 20.07 0.82 0.02354 0.02760 9 2 1 7 0 3713.842 23.53 15.00 20.07 -332 -109 -439 -90 118 454 82 277 84 315 144 144 -340 -186 147 -513 302 -25 -179 -206 203 146 222 334 -20 274 27 -143 -148 -2 -170 -137 -254 280 -317 -38 516 73 112 -70 33 -127 291 136 191 -118 45 174 303 -348 -164 -315 -673 -319 27 -111 -481 -81 12 245 424 265 389 166 304 241 198 174 -327 -146 -131 -311 -267 -211 15 -296 -170 270 -74 95 -236 -301 -452 142 -22 -275 -317 -75 154 -230 161 -85 -153 -291 31 80 80 -25 -197 -262 -189 145 123 -45 -594 -172 58 -51 94 243 -9 -111 386 199 418 270 611 -296 267 369 135 146 105 -123 -92 6 -147 38 -94 412 -161 79 80 14 -129 163 355 -453 323 35 197 -40 281 163 416 -290 -404 -352 -79 -413 -115 -317 -104 -432 -91 123 485 84 289 88 326 147 154 -359 -193 151 -529 313 -27 -184 -216 213 154 234 351 -22 291 29 -150 -152 -2 -175 -140 -249 282 -331 -41 543 76 116 -71 34 -130 299 142 202 -125 47 182 311 -352 -161 -301 -671 -316 26 -109 -487 -83 13 252 433 272 401 172 312 245 198 172 -320 -141 -125 -297 -257 -205 15 -292 -165 257 -70 89 -221 -285 -433 136 -21 -270 -314 -74 152 -228 160 -86 -157 -302 32 82 80 -24 -189 -245 -175 134 116 -44 -607 -177 59 -51 93 239 -9 -112 375 196 415 270 612 -300 268 366 132 140 105 -118 -88 6 -141 36 -90 393 -154 75 78 14 -124 155 345 -430 309 34 193 -39 278 162 414 -291 -400 -341 -74 -383 -106