File name: Pandora199s1_Fukuoka_20250303_L2Fit_ffus5c70d20230726p1-8.txt
File generation date: 20250304T090150.9Z
Data description: Level 2 spectral fitting results file
Data file version: ffus5c70p1-8
Local principal investigator: Hisahiro Takashima
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 199
Spectrometer number: 1
Processing software version used: BlickP v1.8.74
Instrument operation file used: Pandora199_OF_v3d20210122.txt
Instrument calibration file used: Pandora199s1_CF_v70d20230726.txt
Level 1 file used: Pandora199s1_Fukuoka_20250303_L1_smca1c70d20230726p1-8.txt
Full location name: Fukuoka University
Short location name: Fukuoka
Country of location: Japan
Location latitude [deg]: 33.5491
Location longitude [deg]: 130.3660
Location altitude [m]: 55
Local noon date: 20250303
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method)
Data caveats: Initial fieldcal after fiber replacement based on Session 7
First and last pixel inside fitting window: 317 582
Nominal wavelengths inside fitting window [nm]: 322.5312 322.6708 322.8105 322.9501 323.0898 323.2294 323.3690 323.5086 323.6482 323.7878 323.9273 324.0669 324.2064 324.3459 324.4855 324.6250 324.7645 324.9040 325.0434 325.1829 325.3224 325.4618 325.6012 325.7406 325.8801 326.0194 326.1588 326.2982 326.4376 326.5769 326.7163 326.8556 326.9949 327.1342 327.2735 327.4128 327.5521 327.6913 327.8306 327.9698 328.1090 328.2482 328.3874 328.5266 328.6658 328.8050 328.9441 329.0833 329.2224 329.3615 329.5007 329.6398 329.7788 329.9179 330.0570 330.1960 330.3351 330.4741 330.6131 330.7521 330.8911 331.0301 331.1691 331.3081 331.4470 331.5859 331.7249 331.8638 332.0027 332.1416 332.2805 332.4193 332.5582 332.6971 332.8359 332.9747 333.1135 333.2523 333.3911 333.5299 333.6687 333.8074 333.9462 334.0849 334.2236 334.3623 334.5010 334.6397 334.7784 334.9170 335.0557 335.1943 335.3330 335.4716 335.6102 335.7488 335.8874 336.0259 336.1645 336.3030 336.4416 336.5801 336.7186 336.8571 336.9956 337.1341 337.2725 337.4110 337.5494 337.6879 337.8263 337.9647 338.1031 338.2415 338.3799 338.5182 338.6566 338.7949 338.9332 339.0715 339.2098 339.3481 339.4864 339.6247 339.7629 339.9012 340.0394 340.1776 340.3158 340.4540 340.5922 340.7304 340.8686 341.0067 341.1448 341.2830 341.4211 341.5592 341.6973 341.8354 341.9734 342.1115 342.2495 342.3876 342.5256 342.6636 342.8016 342.9396 343.0775 343.2155 343.3535 343.4914 343.6293 343.7672 343.9051 344.0430 344.1809 344.3188 344.4566 344.5945 344.7323 344.8701 345.0079 345.1457 345.2835 345.4213 345.5591 345.6968 345.8345 345.9723 346.1100 346.2477 346.3854 346.5230 346.6607 346.7984 346.9360 347.0736 347.2113 347.3489 347.4865 347.6240 347.7616 347.8992 348.0367 348.1742 348.3118 348.4493 348.5868 348.7243 348.8617 348.9992 349.1366 349.2741 349.4115 349.5489 349.6863 349.8237 349.9611 350.0985 350.2358 350.3732 350.5105 350.6478 350.7851 350.9224 351.0597 351.1970 351.3342 351.4715 351.6087 351.7459 351.8831 352.0203 352.1575 352.2947 352.4319 352.5690 352.7061 352.8433 352.9804 353.1175 353.2546 353.3916 353.5287 353.6658 353.8028 353.9398 354.0768 354.2139 354.3508 354.4878 354.6248 354.7617 354.8987 355.0356 355.1725 355.3094 355.4463 355.5832 355.7201 355.8570 355.9938 356.1306 356.2675 356.4043 356.5411 356.6778 356.8146 356.9514 357.0881 357.2249 357.3616 357.4983 357.6350 357.7717 357.9084 358.0450 358.1817 358.3183 358.4549 358.5915 358.7281 358.8647 359.0013 359.1379
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Bromine oxide effective temperature [K]
Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Formaldehyde effective temperature [K]
Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Nitrous acid effective temperature [K]
Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 60: Nitrogen dioxide effective temperature [K]
Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful
Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 71: Oxygen dimer effective temperature [K]
Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful
Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 82: Ozone effective temperature [K]
Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 93: Sulfur dioxide effective temperature [K]
Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful
Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 101: Lower limit used for wavelength scaling [nm]
Column 102: Upper limit used for wavelength scaling [nm]
Column 103: Order of smoothing polynomial
Column 104: Smoothing polynomial coefficient, order 0
Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 109: Smoothing polynomial coefficient, order 1
Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 114: Smoothing polynomial coefficient, order 2
Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 119: Smoothing polynomial coefficient, order 3
Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 124: Smoothing polynomial coefficient, order 4
Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 129: Mean value of measured data inside fitting window [same units as measurements]
Column 130: Offset polynomial coefficient, order 0
Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 135: Wavelength change polynomial coefficient, order 0
Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 142: Resolution change polynomial coefficient, order 0
Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 154: Wavelength effective temperature [�C], 999=no effective temperature given
Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 158: Number of bright count cycles
Column 159: Number of dark count cycles
Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 163: Integration time [ms]
Column 164: Temperature at electronics board [�C], 999=no temperature signal
Column 165: Spectrometer control temperature [�C], 999=no temperature signal
Column 166: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Column 167: Temperature in head sensor [�C], 999=no temperature signal
Column 168: Humidity in head sensor [%], -9=no humidity signal
Column 169: Pressure in head sensor [hPa], -9=no pressure signal
Columns 170-435: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 436-701: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------