File name: Pandora32s1_GreenbeltMD_20250206_L2Fit_fwvt1c12d20221109p1-8.txt File generation date: 20250207T052900.0Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c12p1-8 Local principal investigator: Thomas Hanisco Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 32 Spectrometer number: 1 Processing software version used: BlickP v1.8.70 Instrument operation file used: Pandora32_OF_v2d20220415.txt Instrument calibration file used: Pandora32s1_CF_v12d20221109.txt Level 1 file used: Pandora32s1_GreenbeltMD_20250206_L1_smca1c12d20221109p1-8.txt Full location name: Goddard Space Flight Center Short location name: GreenbeltMD Country of location: USA Location latitude [deg]: 38.9926 Location longitude [deg]: -76.8396 Location altitude [m]: 90 Local noon date: 20250206 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Based on session 11 with new SO2 and HCHO field cal First and last pixel inside fitting window: 1680 1830 Nominal wavelengths inside fitting window [nm]: 492.0337 492.1546 492.2756 492.3965 492.5174 492.6382 492.7591 492.8799 493.0008 493.1216 493.2424 493.3631 493.4839 493.6046 493.7254 493.8461 493.9668 494.0874 494.2081 494.3287 494.4493 494.5700 494.6905 494.8111 494.9317 495.0522 495.1727 495.2933 495.4137 495.5342 495.6547 495.7751 495.8955 496.0159 496.1363 496.2567 496.3771 496.4974 496.6177 496.7380 496.8583 496.9786 497.0989 497.2191 497.3393 497.4595 497.5797 497.6999 497.8201 497.9402 498.0603 498.1804 498.3005 498.4206 498.5406 498.6607 498.7807 498.9007 499.0207 499.1407 499.2606 499.3806 499.5005 499.6204 499.7403 499.8602 499.9800 500.0999 500.2197 500.3395 500.4593 500.5790 500.6988 500.8185 500.9383 501.0580 501.1776 501.2973 501.4170 501.5366 501.6562 501.7758 501.8954 502.0150 502.1345 502.2541 502.3736 502.4931 502.6126 502.7321 502.8515 502.9709 503.0904 503.2098 503.3291 503.4485 503.5679 503.6872 503.8065 503.9258 504.0451 504.1644 504.2836 504.4028 504.5221 504.6413 504.7604 504.8796 504.9988 505.1179 505.2370 505.3561 505.4752 505.5942 505.7133 505.8323 505.9513 506.0703 506.1893 506.3083 506.4272 506.5462 506.6651 506.7840 506.9028 507.0217 507.1405 507.2594 507.3782 507.4970 507.6157 507.7345 507.8533 507.9720 508.0907 508.2094 508.3281 508.4467 508.5653 508.6840 508.8026 508.9212 509.0397 509.1583 509.2768 509.3954 509.5139 509.6324 509.7508 509.8693 509.9877 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-402: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20250206T220618.4Z 9168.921046 445 1 4.81 2 85.69 246.30 31.66 103.09 0.00 1 0.00 1 0 22 3.781e-03 3.756e-03 1.069e-03 1.068e-03 6.642100e+03 7.004819e+01 4.646171e+02 -6.000000e+00 2.126732e+02 276.37 -2.00 20.00 -2.00 505.34 0.00e+00 2.843500e-03 2.955467e-05 1.576568e-04 -6.000000e+00 1.060008e-04 276.37 -2.00 20.00 -2.00 500.71 0.00e+00 8.135113e-01 2.121256e-02 5.548704e-02 -6.000000e+00 7.609855e-02 224.67 -2.00 3.47 -2.00 502.27 0.00e+00 10.924 0.023 489.00 513.00 1 4.1396e+00 1.6255e-03 1.6899e-02 -6.0000e+00 5.8411e-03 -1.0688e-02 4.0708e-04 1.5126e-03 -6.0000e+00 1.4902e-03 5.9918e-03 1.0438e-03 1.1748e-04 8.3468e-05 -6.0000e+00 4.3428e-04 1.6828e-02 -3.3118e-04 12 1 1 12 1 1 92.58 20.43 2.69 0.01683 0.02407 7 19 1 4 0 599.980 25.47 19.76 20.43 11.97 5.3 934.13 -911 -567 -29 13 273 288 434 604 579 387 295 220 148 -312 -397 -290 -205 -28 242 146 36 219 150 564 327 460 514 49 19 -558 -749 -586 -349 -44 533 404 -255 -79 20 -157 -272 -113 73 245 339 534 281 411 286 -150 -359 -604 -721 -637 -724 -328 163 151 84 114 77 508 408 458 468 268 41 -95 -24 -152 -378 -595 -182 -290 -22 -52 -298 -622 -299 -502 -547 -427 -473 -517 -481 -163 -183 -237 -220 -171 -324 -125 404 570 609 370 228 -112 -135 -569 -717 -701 -748 -314 -300 -122 -79 -196 -252 -62 3 -65 308 417 491 498 781 681 710 534 435 259 199 347 287 -8 221 234 186 152 242 4 -125 -35 -232 -123 -220 -163 -39 366 203 259 154 313 61 77 -32 -324 -337 -580 -485 -852 -531 -28 13 267 284 436 603 580 386 296 218 145 -308 -390 -284 -200 -28 241 148 36 220 152 571 333 470 524 49 19 -556 -733 -579 -343 -44 539 409 -261 -80 20 -157 -272 -113 74 251 345 547 289 418 292 -151 -359 -591 -708 -626 -713 -325 165 153 86 117 79 521 415 465 473 273 41 -95 -24 -151 -371 -585 -179 -288 -22 -51 -296 -612 -290 -493 -537 -414 -461 -509 -478 -160 -181 -235 -218 -170 -324 -124 403 570 606 369 222 -109 -130 -540 -676 -665 -716 -305 -296 -122 -79 -196 -251 -62 3 -65 312 421 500 511 805 696 726 543 444 261 199 351 288 -8 223 237 188 154 243 4 -125 -34 -230 -122 -220 -163 -40 377 209 269 161 323 63 79 -34 -331 -343 -588 -493 SQ 20250206T221534.1Z 9168.927478 447 1 48.63 2 87.34 247.80 29.95 105.18 0.00 1 0.00 1 0 22 5.642e-03 5.594e-03 1.690e-04 1.687e-04 9.031570e+03 1.133677e+01 6.077073e+02 -6.000000e+00 3.173969e+02 276.37 -2.00 20.00 -2.00 505.38 0.00e+00 4.110703e-03 4.682782e-06 2.285827e-04 -6.000000e+00 1.581700e-04 276.37 -2.00 20.00 -2.00 500.91 0.00e+00 8.714057e-01 3.325302e-03 7.898637e-02 -6.000000e+00 1.134967e-01 224.67 -2.00 3.47 -2.00 502.43 0.00e+00 14.413 0.053 489.00 513.00 1 2.3741e+00 2.5461e-04 2.3356e-02 -6.0000e+00 8.7126e-03 -2.9845e-02 6.3363e-05 2.0974e-03 -6.0000e+00 2.2211e-03 2.0896e-02 3.3266e-04 1.8331e-05 1.1511e-04 -6.0000e+00 6.4815e-04 1.5075e-02 -2.6734e-04 12 8 8 10 0 0 57.02 20.43 5.91 0.01508 0.01738 395 93 1 4 0 123.090 25.47 20.19 20.43 12.16 5.3 934.97 -1224 -1042 -500 9 353 593 940 1128 1015 718 432 180 -100 -363 -518 -567 -479 -139 278 316 268 307 387 456 600 601 475 393 48 -520 -943 -873 -688 -189 315 278 74 24 -42 -200 -124 2 184 387 612 694 653 417 279 -64 -538 -939 -1167 -1088 -764 -202 104 236 300 316 385 550 618 596 522 360 118 -105 -200 -438 -612 -672 -540 -340 -122 -151 -492 -725 -737 -761 -807 -726 -706 -647 -531 -365 -404 -397 -387 -301 -197 72 451 659 597 498 300 -22 -397 -819 -1166 -1268 -981 -442 -154 -89 -311 -407 -453 -321 7 192 437 689 880 994 1174 1199 1046 786 575 426 343 397 472 415 365 367 239 352 333 20 -216 -388 -500 -431 -218 -97 4 173 281 283 319 372 353 250 42 -396 -761 -893 -752 -1117 -955 -458 9 335 565 911 1106 999 705 420 173 -95 -343 -496 -545 -456 -134 268 310 265 300 379 449 594 597 472 388 47 -507 -907 -836 -667 -184 313 277 74 24 -41 -197 -122 2 184 393 618 705 665 422 280 -64 -531 -926 -1140 -1065 -746 -201 104 241 303 320 391 560 632 610 534 366 118 -106 -200 -434 -603 -662 -535 -340 -123 -152 -492 -717 -721 -740 -784 -708 -694 -641 -531 -361 -401 -394 -384 -299 -196 72 456 657 603 494 296 -21 -382 -778 -1103 -1212 -941 -429 -155 -89 -315 -411 -455 -323 7 195 449 702 902 1027 1221 1237 1084 812 597 438 349 404 482 426 377 380 248 365 344 21 -220 -392 -506 -440 -222 -101 4 182 299 298 338 397 377 266 45 -420 -798 -931 -787 SQ 20250206T221834.8Z 9168.929569 451 1 48.71 2 87.89 248.29 29.40 105.90 0.00 1 0.00 1 0 22 6.397e-03 6.347e-03 1.981e-04 1.976e-04 1.024438e+04 1.345051e+01 6.824603e+02 -6.000000e+00 3.598911e+02 276.37 -2.00 20.00 -2.00 505.40 0.00e+00 4.526075e-03 5.492808e-06 2.524291e-04 -6.000000e+00 1.793410e-04 276.37 -2.00 20.00 -2.00 500.97 0.00e+00 8.763213e-01 3.889268e-03 8.923444e-02 -6.000000e+00 1.286751e-01 224.67 -2.00 3.47 -2.00 502.48 0.00e+00 15.823 0.070 489.00 513.00 1 2.4751e+00 2.9770e-04 2.6297e-02 -6.0000e+00 9.8780e-03 -3.2159e-02 7.3887e-05 2.3722e-03 -6.0000e+00 2.5177e-03 1.5365e-02 1.6961e-04 2.1302e-05 1.2748e-04 -6.0000e+00 7.3494e-04 1.1770e-02 -2.3596e-04 12 8 8 10 0 0 75.14 20.43 7.15 0.01177 0.01295 303 71 1 4 0 160.210 25.47 20.00 20.43 11.94 5.4 934.67 -1335 -1084 -611 -43 452 679 1066 1274 1200 852 463 184 -107 -411 -606 -594 -516 -119 314 401 353 342 441 497 670 651 525 443 49 -610 -1085 -1010 -800 -264 292 302 119 64 -62 -188 -188 7 241 414 676 773 688 528 279 -73 -592 -987 -1317 -1211 -856 -250 139 317 397 406 454 618 709 719 595 442 94 -159 -267 -491 -720 -799 -603 -432 -222 -193 -603 -838 -847 -872 -954 -847 -802 -722 -592 -461 -425 -474 -474 -355 -214 101 502 754 720 531 286 -27 -442 -966 -1325 -1429 -1090 -489 -170 -146 -296 -417 -493 -364 -11 211 526 714 975 1141 1316 1400 1199 897 686 423 332 465 589 454 454 408 295 419 335 64 -251 -405 -547 -477 -191 -106 -14 200 341 326 331 425 389 266 16 -445 -818 -997 -883 -1211 -988 -556 -40 426 641 1023 1236 1168 828 446 176 -101 -385 -577 -555 -487 -114 300 390 347 337 437 485 656 641 518 434 47 -593 -1039 -963 -772 -255 289 298 118 63 -61 -184 -185 7 241 419 679 782 697 533 279 -73 -583 -956 -1291 -1189 -837 -250 139 323 401 411 460 629 725 738 609 449 95 -158 -268 -489 -714 -792 -600 -434 -221 -192 -596 -834 -833 -853 -933 -830 -792 -719 -583 -457 -423 -473 -472 -353 -214 101 508 751 726 526 282 -26 -426 -918 -1256 -1368 -1047 -475 -171 -147 -300 -422 -498 -369 -11 215 542 729 1002 1181 1373 1473 1246 930 716 437 340 475 604 469 472 426 303 438 349 66 -258 -414 -559 -492 -196 -111 -15 212 365 347 355 457 419 286 17 -469 -867 -1053 -936 SQ 20250206T222139.8Z 9168.931711 455 1 48.60 2 88.44 248.78 28.83 106.65 0.00 1 0.00 1 0 22 8.194e-03 8.123e-03 2.956e-04 2.946e-04 1.136316e+04 2.028718e+01 7.412225e+02 -6.000000e+00 4.609905e+02 276.37 -2.00 20.00 -2.00 505.42 0.00e+00 5.127883e-03 8.201580e-06 2.856099e-04 -6.000000e+00 2.297185e-04 276.37 -2.00 20.00 -2.00 501.05 0.00e+00 8.041645e-01 5.776333e-03 1.017789e-01 -6.000000e+00 1.648087e-01 224.67 -2.00 3.47 -2.00 502.55 0.00e+00 17.336 0.092 489.00 513.00 1 3.0332e+00 4.4212e-04 2.9835e-02 -6.0000e+00 1.2652e-02 -3.7538e-02 1.0942e-04 2.6799e-03 -6.0000e+00 3.2243e-03 7.0755e-03 1.5196e-04 3.1587e-05 1.4012e-04 -6.0000e+00 9.4133e-04 1.3736e-03 -1.6653e-04 12 8 8 10 0 0 16.39 20.43 10.42 0.00137 0.00243 171 40 1 4 0 284.180 25.47 19.81 20.43 11.82 5.4 934.13 -1785 -1535 -878 -115 504 849 1359 1577 1439 1099 697 209 -88 -530 -777 -812 -620 -285 311 472 459 536 590 659 874 867 719 521 45 -719 -1259 -1375 -1016 -411 274 436 240 100 -38 -259 -137 -17 324 605 897 1013 956 769 342 -81 -728 -1264 -1537 -1459 -1016 -292 199 445 550 626 625 799 926 945 787 575 150 -211 -358 -640 -925 -996 -831 -548 -256 -284 -687 -1050 -1084 -1205 -1202 -1201 -1047 -932 -735 -595 -596 -643 -593 -448 -263 128 623 863 905 662 377 -17 -633 -1260 -1702 -1741 -1317 -552 -180 -32 -353 -434 -595 -450 -49 250 674 981 1257 1534 1682 1753 1510 1132 779 485 494 573 702 620 553 552 458 502 324 -15 -353 -549 -754 -634 -337 -137 56 288 449 456 384 531 494 305 51 -605 -1080 -1289 -1175 -1602 -1384 -787 -106 464 800 1300 1488 1364 1040 654 200 -83 -497 -726 -761 -586 -267 297 457 438 514 568 638 850 849 705 509 44 -684 -1210 -1318 -962 -398 265 428 237 98 -38 -254 -134 -17 324 598 896 1021 966 774 341 -80 -722 -1235 -1488 -1418 -1002 -288 201 446 555 634 635 815 949 971 807 586 151 -212 -355 -631 -927 -999 -819 -545 -256 -284 -684 -1035 -1081 -1194 -1191 -1194 -1024 -919 -731 -596 -599 -646 -595 -448 -264 129 621 863 896 658 366 -16 -603 -1187 -1600 -1653 -1279 -541 -178 -32 -360 -442 -606 -450 -49 256 697 1003 1293 1589 1759 1850 1604 1201 819 505 509 590 726 646 580 581 474 519 342 -16 -367 -568 -782 -663 -351 -145 59 308 485 498 414 575 535 330 55 -655 -1160 -1379 -1264 SQ 20250206T222445.6Z 9168.933861 459 1 48.44 2 89.00 249.27 28.27 107.43 0.00 1 0.00 1 0 36 1.113e-02 1.102e-02 4.743e-04 4.718e-04 1.228276e+04 3.272141e+01 7.759708e+02 -6.000000e+00 6.259046e+02 276.37 -2.00 20.00 -2.00 505.44 0.00e+00 6.204049e-03 1.316786e-05 3.437424e-04 -6.000000e+00 3.118760e-04 276.37 -2.00 20.00 -2.00 501.17 0.00e+00 6.863353e-01 9.228013e-03 1.171757e-01 -6.000000e+00 2.236934e-01 224.68 -2.00 3.47 -2.00 502.64 0.00e+00 18.795 0.117 489.00 513.00 1 3.7109e+00 7.0646e-04 3.3836e-02 -6.0000e+00 1.7174e-02 -4.1019e-02 1.7397e-04 3.0043e-03 -6.0000e+00 4.3746e-03 2.9054e-03 -3.3593e-04 5.0534e-05 1.6078e-04 -6.0000e+00 1.2782e-03 7.8375e-04 -1.3137e-04 12 8 8 10 0 0 79.82 20.43 15.46 0.00078 -0.00155 83 19 1 4 0 583.580 25.47 19.71 20.43 11.72 5.4 933.49 -2544 -2264 -1370 -405 499 1103 1792 1936 1998 1531 867 324 -178 -680 -1106 -1081 -841 -442 344 607 649 607 861 926 1225 1213 970 712 -54 -958 -1697 -1829 -1348 -529 460 510 421 245 -17 -306 -193 68 550 862 1253 1415 1473 1057 629 -88 -848 -1649 -2131 -1942 -1296 -432 365 656 892 884 1030 1133 1236 1309 1067 796 314 -158 -536 -825 -1156 -1323 -1055 -839 -377 -419 -890 -1365 -1507 -1700 -1744 -1605 -1404 -1142 -1087 -856 -750 -907 -822 -680 -425 167 747 1232 1234 873 427 -91 -826 -1783 -2134 -2280 -1687 -734 -233 131 -264 -564 -789 -616 -99 362 994 1372 1798 2099 2277 2308 1939 1635 1023 612 611 775 966 837 836 727 579 581 458 14 -475 -832 -1099 -942 -562 -221 74 389 502 527 581 634 600 356 -46 -716 -1404 -1697 -1600 -2241 -2004 -1233 -362 457 1032 1651 1805 1867 1429 804 299 -163 -635 -1031 -981 -771 -411 325 581 609 573 815 882 1172 1168 937 685 -51 -902 -1581 -1702 -1267 -507 450 493 410 237 -16 -295 -187 67 543 863 1235 1407 1468 1053 622 -86 -840 -1615 -2075 -1897 -1283 -425 366 668 916 889 1038 1148 1259 1336 1089 808 317 -158 -532 -834 -1166 -1336 -1069 -836 -377 -419 -887 -1349 -1514 -1700 -1743 -1608 -1377 -1127 -1083 -858 -753 -911 -823 -679 -426 168 758 1250 1242 864 413 -88 -788 -1689 -2015 -2177 -1645 -717 -235 131 -268 -573 -802 -629 -102 368 1021 1421 1873 2202 2412 2411 2043 1721 1071 649 642 813 1018 869 873 764 610 613 482 15 -495 -864 -1146 -991 -599 -234 79 423 552 585 634 695 658 389 -50 -790 -1540 -1858 -1762 SQ 20250206T222803.2Z 9168.936148 463 1 49.42 2 89.60 249.79 27.67 108.27 0.00 1 0.00 1 0 36 1.684e-02 1.670e-02 9.245e-04 9.189e-04 1.208499e+04 6.337777e+01 7.132306e+02 -6.000000e+00 9.475654e+02 276.37 -2.00 20.00 -2.00 505.45 0.00e+00 7.754690e-03 2.563558e-05 4.235445e-04 -6.000000e+00 4.721539e-04 276.37 -2.00 20.00 -2.00 501.23 0.00e+00 3.851556e-01 1.796123e-02 1.327817e-01 -6.000000e+00 3.386587e-01 224.68 -2.00 3.47 -2.00 502.69 0.00e+00 20.053 0.142 489.00 513.00 1 4.7866e+00 1.3748e-03 3.7854e-02 -6.0000e+00 2.6000e-02 -2.9839e-02 3.3811e-04 3.2388e-03 -6.0000e+00 6.6230e-03 8.3103e-04 -5.0486e-04 9.8889e-05 1.8332e-04 -6.0000e+00 1.9351e-03 2.9874e-03 -1.4624e-04 12 8 8 10 0 0 71.52 20.42 24.12 0.00299 -0.00051 29 7 1 4 0 1703.870 25.47 19.76 20.42 11.60 5.4 932.91 -4092 -4017 -2505 -1165 575 1481 2255 2756 2522 2034 1354 255 -417 -1078 -1663 -2002 -1331 -1004 487 769 876 1140 1305 1534 2082 1928 1668 1012 -31 -1374 -2366 -2861 -2024 -960 814 891 956 631 133 -270 -85 156 1011 1460 2107 2221 2173 1883 964 -3 -980 -2239 -2826 -2810 -1785 -595 753 1023 1644 1521 1660 1925 1814 2220 1784 1337 586 40 -958 -1002 -1821 -1919 -1653 -1248 -720 -706 -1148 -2135 -2265 -2711 -2514 -2385 -2200 -1602 -1669 -1304 -1232 -1427 -1211 -869 -568 391 960 1802 1762 1267 857 -194 -1312 -2414 -3004 -3149 -2353 -969 -426 452 -202 -647 -1027 -567 -197 450 1546 2150 2541 3148 3418 3379 2760 2506 1592 870 763 1077 1542 1240 1397 1101 710 770 514 -242 -803 -1228 -1633 -1647 -1157 -514 38 547 588 773 743 957 1062 515 110 -1163 -2069 -2735 -2846 -3621 -3579 -2173 -1032 517 1355 2091 2574 2367 1905 1260 236 -384 -989 -1525 -1844 -1232 -909 444 711 816 1063 1221 1443 1966 1836 1595 968 -29 -1295 -2211 -2679 -1908 -921 762 848 914 603 127 -258 -81 152 988 1447 2109 2171 2133 1846 943 -3 -974 -2210 -2779 -2777 -1723 -584 751 1036 1672 1557 1706 1986 1826 2233 1799 1343 605 41 -982 -1018 -1852 -1952 -1687 -1241 -718 -705 -1141 -2115 -2295 -2743 -2535 -2411 -2161 -1577 -1659 -1301 -1231 -1427 -1204 -861 -564 389 963 1804 1753 1242 850 -189 -1263 -2307 -2865 -3031 -2304 -939 -425 456 -207 -665 -1059 -568 -200 462 1596 2237 2662 3312 3628 3517 2903 2631 1667 906 812 1143 1639 1293 1465 1164 755 819 546 -256 -847 -1292 -1726 -1758 -1249 -562 41 593 644 853 826 1066 1181 573 121 -1282 -2270 -3006 -3152