File name: Pandora71s1_GreenbeltMD_20250206_L2Fit_fwvt1c1d20220202p1-8.txt File generation date: 20250207T052924.9Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c1p1-8 Local principal investigator: Tom Hanisco Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 71 Spectrometer number: 1 Processing software version used: BlickP v1.8.70 Instrument operation file used: Pandora71_OF_v7d20201007.txt Instrument calibration file used: Pandora71s1_CF_v1d20220202.txt Level 1 file used: Pandora71s1_GreenbeltMD_20250206_L1_smca1c1d20220202p1-8.txt Full location name: Goddard Space Flight Center Short location name: GreenbeltMD Country of location: USA Location latitude [deg]: 38.9926 Location longitude [deg]: -76.8396 Location altitude [m]: 90 Local noon date: 20250206 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are blind pixel subtraction, dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1657 1807 Nominal wavelengths inside fitting window [nm]: 492.0762 492.1966 492.3171 492.4375 492.5580 492.6784 492.7988 492.9191 493.0395 493.1598 493.2802 493.4005 493.5208 493.6410 493.7613 493.8815 494.0017 494.1219 494.2421 494.3623 494.4825 494.6026 494.7227 494.8428 494.9629 495.0830 495.2030 495.3231 495.4431 495.5631 495.6831 495.8030 495.9230 496.0429 496.1628 496.2827 496.4026 496.5225 496.6423 496.7621 496.8820 497.0018 497.1215 497.2413 497.3610 497.4808 497.6005 497.7202 497.8399 497.9595 498.0792 498.1988 498.3184 498.4380 498.5576 498.6771 498.7967 498.9162 499.0357 499.1552 499.2746 499.3941 499.5135 499.6330 499.7524 499.8717 499.9911 500.1105 500.2298 500.3491 500.4684 500.5877 500.7070 500.8262 500.9455 501.0647 501.1839 501.3030 501.4222 501.5414 501.6605 501.7796 501.8987 502.0178 502.1368 502.2559 502.3749 502.4939 502.6129 502.7319 502.8508 502.9698 503.0887 503.2076 503.3265 503.4453 503.5642 503.6830 503.8018 503.9206 504.0394 504.1582 504.2769 504.3957 504.5144 504.6331 504.7517 504.8704 504.9890 505.1077 505.2263 505.3449 505.4635 505.5820 505.7005 505.8191 505.9376 506.0561 506.1745 506.2930 506.4114 506.5298 506.6482 506.7666 506.8850 507.0033 507.1217 507.2400 507.3583 507.4765 507.5948 507.7130 507.8313 507.9495 508.0677 508.1858 508.3040 508.4221 508.5402 508.6584 508.7764 508.8945 509.0126 509.1306 509.2486 509.3666 509.4846 509.6025 509.7205 509.8384 509.9563 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-252: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 253-403: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20250206T220613.5Z 9168.920990 454 1 23.41 2 85.67 246.29 31.67 103.07 0.00 1 0.00 1 0 92 1.334e-02 1.320e-02 8.757e-04 8.748e-04 6.089190e+03 5.068107e+01 4.047958e+02 -6.000000e+00 6.630704e+02 276.37 -2.00 20.00 -2.00 505.34 0.00e+00 2.533798e-03 2.312747e-05 2.536012e-05 -6.000000e+00 3.571406e-04 276.37 -2.00 20.00 -2.00 500.73 0.00e+00 9.712440e-01 1.571863e-02 5.355313e-02 -6.000000e+00 2.546223e-01 224.67 -2.00 3.47 -2.00 502.29 0.00e+00 10.899 0.023 489.00 513.00 1 4.1602e+00 1.2043e-03 1.6169e-02 -6.0000e+00 1.9378e-02 -6.7541e-03 2.9748e-04 1.0053e-03 -6.0000e+00 5.2005e-03 5.8799e-03 9.0887e-02 5.9384e-05 3.5458e-05 -6.0000e+00 9.1624e-04 4.7708e-02 1.4453e-04 12 13 9 12 5 1 99.89 29.85 1.32 0.04771 0.67814 34 9 1 2 0 668.401 20.10 29.85 12.47 27.25 27.50 7.6 1032.12 1516 1662 1607 347 422 712 -339 -1621 -1484 -1634 -1630 -548 1509 595 -329 574 -37 149 1474 1125 1450 2489 1020 -3088 -2099 -1905 -2469 3 2510 1076 160 510 -460 -884 -964 -316 -310 633 1223 1291 1330 1320 1517 1014 -1152 -2042 -3070 -3623 -1665 -362 545 127 458 -600 -361 320 1041 1182 1052 736 97 14 370 -879 -2016 -1137 -459 -122 1299 1210 -487 -785 -881 -1522 -1827 -547 -482 -1496 14 90 167 -681 -668 -770 -787 -207 1861 2721 1813 1822 1728 995 -48 -2223 -2942 -3181 -2466 -216 2042 785 420 -363 -2200 -1429 -579 5 -108 420 451 183 952 1981 2243 1113 747 110 -1273 -177 911 -103 597 874 410 925 2212 11 -667 -532 -2109 -2464 -629 -160 -525 228 324 -42 417 975 1591 1805 1573 95 -1340 -2001 -1846 -1138 191 1180 717 -251 900000 1516 1683 1627 349 417 719 -340 -1608 -1467 -1626 -1587 -542 1526 598 -331 575 -37 150 1487 1142 1459 2481 1013 -3088 -2042 -1868 -2460 3 2562 1120 165 518 -467 -888 -970 -321 -317 636 1238 1320 1351 1326 1544 1019 -1135 -1972 -2944 -3489 -1626 -365 546 129 466 -610 -366 325 1064 1205 1072 740 97 14 370 -874 -1985 -1117 -454 -122 1269 1188 -474 -769 -855 -1476 -1772 -532 -475 -1481 14 88 164 -670 -654 -755 -775 -205 1855 2741 1809 1773 1649 955 -46 -2085 -2744 -2995 -2374 -208 2036 777 413 -355 -2201 -1418 -568 5 -109 428 462 189 954 1999 2271 1118 763 111 -1272 -176 917 -105 603 886 414 929 2228 11 -657 -521 -2082 -2428 -632 -160 -534 234 337 -44 436 1022 1665 1888 1633 97 -1346 -1996 -1852 -1158 197 1236 735 -263 900000 SQ 20250206T221033.4Z 9168.923997 457 1 11.16 2 86.45 246.99 30.87 104.03 0.00 1 0.00 1 0 99 1.361e-02 1.348e-02 5.525e-04 5.518e-04 7.014998e+03 3.215578e+01 4.200461e+02 -6.000000e+00 6.767818e+02 276.37 -2.00 20.00 -2.00 505.38 0.00e+00 2.927893e-03 1.459538e-05 2.072260e-05 -6.000000e+00 3.637926e-04 276.37 -2.00 20.00 -2.00 500.85 0.00e+00 1.051935e+00 9.819221e-03 5.801733e-02 -6.000000e+00 2.574302e-01 224.67 -2.00 3.47 -2.00 502.40 0.00e+00 12.357 0.033 489.00 513.00 1 2.3456e+00 7.5272e-04 1.8537e-02 -6.0000e+00 1.9629e-02 -2.3296e-02 1.8305e-04 1.1449e-03 -6.0000e+00 5.1983e-03 2.9120e-02 9.5781e-02 3.7446e-05 3.6989e-05 -6.0000e+00 9.2513e-04 4.5984e-02 -4.9327e-05 12 13 9 12 5 1 22.19 29.60 1.82 0.04598 0.71036 69 37 1 2 0 159.051 19.93 29.60 12.49 27.50 27.50 7.5 1032.23 1599 1763 1747 561 529 842 -596 -1660 -1531 -1598 -1623 -609 1444 503 -398 429 16 129 1615 1303 1492 2335 977 -3091 -2017 -1919 -2583 112 2685 1001 154 317 -408 -990 -1044 -360 -256 783 1198 1553 1462 1296 1423 912 -1245 -1993 -3077 -3451 -1518 -295 506 223 388 -629 -213 363 982 966 1091 597 23 28 289 -1172 -2084 -1098 -709 -237 1384 1188 -375 -794 -1131 -1379 -1762 -499 -729 -1644 29 39 312 -718 -848 -911 -771 -119 1913 2853 1861 1989 1843 824 -254 -2258 -3038 -3305 -2661 -243 1908 891 319 -282 -2154 -1702 -438 -64 70 434 579 144 1182 2192 2062 1071 922 58 -1085 -158 1012 -112 496 909 338 1131 2335 56 -759 -548 -2059 -2437 -358 -112 -516 157 511 35 504 1093 1724 1931 1765 137 -1538 -2167 -1824 -1211 249 1147 675 -181 -335 1585 1768 1752 558 517 816 -576 -1625 -1495 -1531 -1572 -600 1420 505 -401 431 16 131 1634 1294 1509 2345 975 -3012 -1963 -1840 -2519 111 2698 1002 156 318 -408 -984 -1039 -362 -260 783 1211 1580 1481 1300 1407 911 -1220 -1961 -3010 -3310 -1479 -290 510 228 397 -629 -217 363 989 973 1094 606 23 27 283 -1146 -2062 -1084 -690 -233 1368 1181 -369 -764 -1108 -1344 -1720 -490 -707 -1604 28 39 303 -700 -843 -907 -770 -116 1892 2848 1840 1958 1778 797 -242 -2134 -2857 -3140 -2530 -237 1896 884 315 -283 -2150 -1693 -432 -64 71 445 585 147 1199 2245 2130 1096 931 59 -1096 -159 1009 -113 498 916 340 1154 2338 56 -762 -547 -2072 -2451 -358 -116 -527 162 533 36 530 1155 1819 2035 1845 142 -1598 -2238 -1893 -1249 261 1194 707 -188 -354 SQ 20250206T221550.0Z 9168.927662 459 1 54.21 2 87.39 247.85 29.90 105.24 0.00 1 0.00 1 0 99 1.433e-02 1.413e-02 3.250e-04 3.242e-04 8.547225e+03 1.927284e+01 5.061929e+02 -6.000000e+00 7.126931e+02 276.37 -2.00 20.00 -2.00 505.41 0.00e+00 3.890010e-03 8.595867e-06 3.221062e-05 -6.000000e+00 3.831011e-04 276.37 -2.00 20.00 -2.00 500.99 0.00e+00 1.120512e+00 5.746031e-03 6.729326e-02 -6.000000e+00 2.710769e-01 224.67 -2.00 3.47 -2.00 502.52 0.00e+00 14.532 0.054 489.00 513.00 1 2.4327e+00 4.4019e-04 2.2439e-02 -6.0000e+00 2.0670e-02 -3.2321e-02 1.0635e-04 1.3666e-03 -6.0000e+00 5.4731e-03 1.9298e-02 9.6039e-02 2.1827e-05 4.5750e-05 -6.0000e+00 9.7386e-04 1.8705e-02 1.2401e-04 12 13 8 11 4 0 90.68 29.79 2.55 0.01871 0.68487 297 32 1 2 0 182.174 20.01 29.79 12.62 27.25 27.50 7.5 1032.11 1839 1993 1973 688 631 989 -483 -1636 -1522 -1655 -1644 -536 1532 629 -342 570 -87 302 1541 1309 1609 2472 919 -3234 -2334 -2015 -2699 -54 2606 1128 100 311 -458 -1151 -1102 -397 -262 772 1197 1726 1327 1407 1443 842 -1435 -2098 -3329 -3581 -1652 -351 509 339 365 -561 -106 399 1060 1117 1160 687 8 -81 152 -1289 -2226 -1276 -829 -360 1227 1108 -582 -1044 -1176 -1515 -1904 -639 -784 -1649 -51 54 114 -802 -853 -942 -706 -88 2110 3030 2014 2111 1704 791 -248 -2397 -3285 -3567 -2779 -364 1833 832 310 -567 -2428 -1668 -433 73 33 530 782 280 1190 2326 2349 1223 1046 37 -1194 -155 1067 -24 649 1124 386 1140 2379 -36 -869 -559 -2147 -2466 -374 -101 -400 271 532 180 584 1209 1672 1995 1575 54 -1643 -2196 -1890 -1230 186 1065 718 -274 -349 1812 1988 1886 681 614 955 -464 -1558 -1446 -1584 -1591 -526 1476 620 -337 561 -86 299 1535 1311 1602 2444 905 -3113 -2193 -1909 -2603 -53 2547 1123 99 304 -446 -1117 -1072 -390 -260 774 1215 1763 1355 1420 1437 829 -1389 -1989 -3146 -3396 -1593 -350 520 337 364 -559 -105 399 1067 1123 1164 682 8 -81 152 -1286 -2195 -1257 -824 -360 1190 1080 -562 -1027 -1148 -1473 -1854 -625 -776 -1576 -49 53 111 -784 -830 -916 -689 -87 2085 3023 1989 2025 1667 756 -234 -2246 -3064 -3361 -2682 -348 1823 846 315 -573 -2444 -1670 -441 73 34 541 802 288 1229 2427 2472 1278 1079 37 -1206 -155 1087 -25 667 1160 398 1168 2447 -37 -877 -562 -2178 -2503 -386 -104 -415 284 565 193 626 1298 1795 2137 1678 57 -1704 -2266 -1962 -1297 199 1159 786 -299 -378 SQ 20250206T222000.8Z 9168.930565 465 1 54.25 2 88.14 248.52 29.13 106.24 0.00 1 0.00 1 0 113 1.512e-02 1.492e-02 4.445e-04 4.427e-04 1.032799e+04 2.691773e+01 5.963153e+02 -6.000000e+00 7.516949e+02 276.37 -2.00 20.00 -2.00 505.46 0.00e+00 4.551127e-03 1.182581e-05 6.200254e-05 -6.000000e+00 4.042584e-04 276.37 -2.00 20.00 -2.00 501.08 0.00e+00 1.141741e+00 7.869190e-03 7.360866e-02 -6.000000e+00 2.862549e-01 224.67 -2.00 3.47 -2.00 502.61 0.00e+00 16.524 0.079 489.00 513.00 1 2.7219e+00 6.0324e-04 2.6489e-02 -6.0000e+00 2.1823e-02 -4.0047e-02 1.4471e-04 1.5720e-03 -6.0000e+00 5.7862e-03 1.0800e-02 9.7893e-02 2.9645e-05 5.5707e-05 -6.0000e+00 1.0277e-03 1.5914e-02 6.9492e-05 12 13 8 11 4 0 46.55 29.76 3.53 0.01591 0.69494 203 22 1 2 0 266.883 19.95 29.76 12.27 27.50 27.75 7.7 1031.90 2016 2404 2231 805 782 994 -400 -1592 -1430 -1500 -1625 -393 1584 651 -198 544 25 401 1638 1453 1702 2536 827 -3344 -2473 -2155 -2736 24 2660 1206 121 166 -579 -1325 -1073 -332 -312 694 1215 1699 1509 1284 1360 776 -1568 -2256 -3564 -3667 -1731 -248 530 320 508 -598 -31 415 1017 1134 1240 632 -84 -161 76 -1410 -2395 -1324 -948 -412 1127 980 -667 -1193 -1317 -1620 -2092 -735 -869 -1754 -149 63 33 -850 -1108 -1012 -787 98 2339 3289 2247 2225 1793 726 -212 -2570 -3589 -3870 -3078 -568 1692 731 222 -737 -2584 -1741 -445 153 162 565 797 302 1258 2566 2480 1282 1038 13 -1203 -69 1128 77 876 1239 515 1279 2534 -35 -814 -445 -2174 -2490 -310 -105 -297 410 636 265 657 1284 1779 2027 1647 10 -1782 -2323 -1976 -1302 160 1006 691 -303 -384 1881 2264 2104 755 720 955 -383 -1509 -1353 -1429 -1493 -366 1512 636 -194 531 24 393 1620 1446 1685 2494 811 -3207 -2319 -2038 -2633 23 2581 1191 118 161 -562 -1281 -1039 -325 -309 696 1234 1737 1539 1300 1359 766 -1523 -2150 -3391 -3501 -1682 -249 521 319 507 -599 -31 416 1029 1147 1251 632 -83 -157 74 -1363 -2395 -1265 -914 -400 1103 964 -649 -1139 -1249 -1599 -1977 -697 -834 -1692 -144 62 32 -838 -1087 -990 -773 97 2323 3295 2224 2138 1684 697 -200 -2426 -3377 -3681 -2873 -547 1696 719 218 -723 -2636 -1693 -441 155 166 581 824 314 1312 2705 2645 1361 1087 13 -1232 -70 1165 80 913 1299 540 1333 2651 -36 -836 -456 -2253 -2585 -328 -109 -313 436 687 288 717 1406 1947 2214 1788 11 -1892 -2455 -2101 -1407 176 1081 747 -326 -428 SQ 20250206T222415.0Z 9168.933507 471 1 54.07 2 88.91 249.19 28.36 107.30 0.00 1 0.00 1 0 120 1.682e-02 1.648e-02 8.693e-04 8.629e-04 1.254141e+04 5.378930e+01 7.068982e+02 -6.000000e+00 8.359499e+02 276.37 -2.00 20.00 -2.00 505.49 0.00e+00 6.001954e-03 2.308549e-05 1.320011e-04 -6.000000e+00 4.495205e-04 276.37 -2.00 20.00 -2.00 501.30 0.00e+00 1.028202e+00 1.523117e-02 7.857835e-02 -6.000000e+00 3.182642e-01 224.68 -2.00 3.47 -2.00 502.76 0.00e+00 18.567 0.113 489.00 513.00 1 3.6685e+00 1.1681e-03 3.1412e-02 -6.0000e+00 2.4264e-02 -5.7057e-02 2.7687e-04 1.8034e-03 -6.0000e+00 6.4316e-03 3.1118e-03 9.8423e-02 5.7319e-05 7.1304e-05 -6.0000e+00 1.1427e-03 1.1667e-02 1.1056e-04 12 13 8 11 4 0 47.79 29.72 6.10 0.01167 0.69437 70 8 1 2 0 771.970 20.10 29.72 12.08 27.50 27.75 7.7 1031.32 2886 2899 2644 1024 1094 1207 -206 -1648 -1298 -1488 -1497 -87 1855 764 -84 731 221 408 1954 1554 1850 2675 546 -3775 -2832 -2345 -3033 -1 2574 1211 -26 -64 -763 -1548 -1142 -478 -3 672 1537 1820 1684 1300 1329 570 -1955 -2724 -3860 -3874 -1856 -129 502 384 449 -656 48 714 1405 1390 1392 783 -143 -209 -89 -1805 -2676 -1446 -1109 -517 1093 991 -1083 -1398 -1628 -1961 -2224 -876 -1056 -1963 -159 26 -202 -1025 -1341 -1188 -745 217 2672 3400 2286 2428 1733 411 -405 -2840 -4251 -4368 -3459 -631 1578 741 -58 -944 -2783 -1817 -545 376 371 927 975 475 1591 3038 2908 1367 1288 126 -1150 149 1328 289 1015 1585 584 1262 2611 -304 -752 -572 -2131 -2412 -77 102 -264 527 796 561 872 1607 1960 2183 1768 -235 -2014 -2617 -2185 -1404 159 1126 762 -436 -645 2656 2702 2468 952 998 1094 -186 -1480 -1162 -1344 -1368 -81 1760 699 -77 670 204 377 1818 1459 1729 2487 507 -3436 -2524 -2106 -2778 -1 2489 1190 -25 -62 -740 -1499 -1109 -471 -3 644 1487 1778 1641 1261 1274 541 -1932 -2648 -3746 -3778 -1748 -125 500 387 455 -666 49 727 1440 1428 1427 796 -144 -208 -88 -1787 -2622 -1414 -1094 -513 1094 996 -1082 -1368 -1583 -1900 -2154 -851 -1037 -1940 -158 26 -204 -1033 -1344 -1184 -743 218 2703 3298 2301 2366 1650 383 -372 -2610 -3906 -4055 -3298 -621 1536 738 -58 -943 -2772 -1807 -553 388 387 972 1031 505 1697 3127 3033 1426 1322 135 -1214 157 1346 296 1042 1637 604 1301 2700 -316 -764 -581 -2189 -2487 -81 110 -287 580 890 631 986 1819 2217 2464 1983 -262 -2222 -2882 -2425 -1583 173 1252 853 -488 -721 SQ 20250206T222834.4Z 9168.936509 477 1 54.82 2 89.70 249.88 27.58 108.41 0.00 1 0.00 1 0 127 2.117e-02 2.061e-02 2.360e-03 2.327e-03 1.476205e+04 1.472688e+02 9.037524e+02 -6.000000e+00 1.053324e+03 276.37 -2.00 20.00 -2.00 505.53 0.00e+00 8.739145e-03 6.270658e-05 2.849797e-04 -6.000000e+00 5.671414e-04 276.37 -2.00 20.00 -2.00 501.53 0.00e+00 5.340647e-01 4.099439e-02 9.182557e-02 -6.000000e+00 4.049710e-01 224.68 -2.00 3.47 -2.00 502.93 0.00e+00 20.208 0.145 489.00 513.00 1 5.2160e+00 3.1454e-03 3.6536e-02 -6.0000e+00 3.0809e-02 -6.8091e-02 7.4651e-04 2.0602e-03 -6.0000e+00 8.2847e-03 5.2471e-04 9.5990e-02 1.5322e-04 1.0565e-04 -6.0000e+00 1.4476e-03 1.7073e-02 2.0207e-04 12 13 8 11 4 0 78.40 29.65 12.04 0.01707 0.68290 15 2 1 2 0 3653.898 20.10 29.65 11.92 27.50 27.75 7.7 1030.75 4325 4377 4278 2390 1495 1165 15 -1430 -1520 -1948 -1273 -80 1998 1282 288 673 275 772 2684 2103 2101 3019 599 -4071 -3885 -3077 -3520 -318 3397 1530 72 -17 -1596 -2309 -1094 -31 -555 861 1611 2410 1787 609 1256 87 -2648 -3278 -4689 -4663 -2211 -180 533 472 1187 -526 617 1298 1394 1674 1923 505 -220 -562 -561 -2377 -3139 -1658 -2163 -835 717 654 -1525 -1487 -2006 -2685 -2981 -1431 -1152 -2340 -572 -261 -246 -1336 -2238 -1756 -862 4 2895 4414 2665 2706 1520 761 -889 -3690 -5170 -5628 -4205 -1291 1314 510 104 -1571 -3770 -1796 -227 996 480 1465 1985 1250 2661 3660 3624 2220 1146 -6 -1217 717 1569 800 1175 2008 1004 1919 2452 -373 -596 -430 -2630 -2967 -396 43 -431 680 1169 824 1224 1474 1962 2492 2287 -50 -2577 -3296 -2571 -1718 258 1189 708 -793 900000 3773 3862 3770 2099 1300 1011 13 -1225 -1305 -1690 -1110 -70 1805 1177 265 585 241 677 2364 1877 1875 2678 532 -3557 -3351 -2669 -3106 -286 3129 1438 67 -15 -1502 -2175 -1028 -29 -542 802 1521 2289 1705 584 1183 82 -2458 -3172 -4297 -4303 -2073 -173 527 474 1189 -532 621 1315 1432 1719 1967 517 -223 -563 -560 -2378 -3106 -1635 -2170 -837 725 663 -1537 -1466 -1973 -2638 -2927 -1405 -1137 -2330 -572 -264 -249 -1349 -2254 -1751 -858 4 2924 4467 2675 2628 1445 704 -819 -3412 -4776 -5263 -4019 -1273 1273 507 104 -1573 -3786 -1790 -231 1029 504 1545 2100 1334 2846 3996 4013 2333 1259 -7 -1307 762 1699 876 1230 2111 1058 2118 2600 -396 -650 -447 -2782 -3153 -428 48 -480 762 1331 945 1409 1705 2263 2855 2599 -57 -2914 -3730 -2926 -1989 303 1420 813 -914 900000