File name: Pandora71s1_GreenbeltMD_20250314_L2Fit_fwvt1c1d20220202p1-8.txt File generation date: 20250508T223849.5Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c1p1-8 Local principal investigator: Tom Hanisco Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 71 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora71_OF_v7d20201007.txt Instrument calibration file used: Pandora71s1_CF_v1d20220202.txt Level 1 file used: Pandora71s1_GreenbeltMD_20250314_L1_smca1c1d20220202p1-8.txt Full location name: Goddard Space Flight Center Short location name: GreenbeltMD Country of location: USA Location latitude [deg]: 38.9926 Location longitude [deg]: -76.8396 Location altitude [m]: 90 Local noon date: 20250314 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are blind pixel subtraction, dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1657 1807 Nominal wavelengths inside fitting window [nm]: 492.0762 492.1966 492.3171 492.4375 492.5580 492.6784 492.7988 492.9191 493.0395 493.1598 493.2802 493.4005 493.5208 493.6410 493.7613 493.8815 494.0017 494.1219 494.2421 494.3623 494.4825 494.6026 494.7227 494.8428 494.9629 495.0830 495.2030 495.3231 495.4431 495.5631 495.6831 495.8030 495.9230 496.0429 496.1628 496.2827 496.4026 496.5225 496.6423 496.7621 496.8820 497.0018 497.1215 497.2413 497.3610 497.4808 497.6005 497.7202 497.8399 497.9595 498.0792 498.1988 498.3184 498.4380 498.5576 498.6771 498.7967 498.9162 499.0357 499.1552 499.2746 499.3941 499.5135 499.6330 499.7524 499.8717 499.9911 500.1105 500.2298 500.3491 500.4684 500.5877 500.7070 500.8262 500.9455 501.0647 501.1839 501.3030 501.4222 501.5414 501.6605 501.7796 501.8987 502.0178 502.1368 502.2559 502.3749 502.4939 502.6129 502.7319 502.8508 502.9698 503.0887 503.2076 503.3265 503.4453 503.5642 503.6830 503.8018 503.9206 504.0394 504.1582 504.2769 504.3957 504.5144 504.6331 504.7517 504.8704 504.9890 505.1077 505.2263 505.3449 505.4635 505.5820 505.7005 505.8191 505.9376 506.0561 506.1745 506.2930 506.4114 506.5298 506.6482 506.7666 506.8850 507.0033 507.1217 507.2400 507.3583 507.4765 507.5948 507.7130 507.8313 507.9495 508.0677 508.1858 508.3040 508.4221 508.5402 508.6584 508.7764 508.8945 509.0126 509.1306 509.2486 509.3666 509.4846 509.6025 509.7205 509.8384 509.9563 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-252: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 253-403: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20250314T172518.0Z 9204.725902 429 1 11.10 2 41.27 183.36 141.39 356.60 0.00 1 0.00 1 0 92 1.216e-02 1.209e-02 2.770e-03 2.765e-03 1.109070e+03 1.433877e+02 9.990359e+01 -6.000000e+00 6.086992e+02 278.00 -2.00 20.00 -2.00 505.25 0.00e+00 1.930862e-04 7.267915e-05 1.063082e-04 -6.000000e+00 3.269473e-04 278.00 -2.00 20.00 -2.00 500.40 0.00e+00 -6.714690e-02 4.989567e-02 3.094964e-02 -6.000000e+00 2.327991e-01 226.31 -2.00 3.47 -2.00 502.00 0.00e+00 1.329 0.000 489.00 513.00 1 6.9168e+00 3.8243e-03 3.7032e-03 -6.0000e+00 1.7717e-02 1.6002e-02 9.6753e-04 3.9957e-04 -6.0000e+00 4.7658e-03 1.6081e-03 9.1340e-02 1.8991e-04 2.0144e-05 -6.0000e+00 8.3478e-04 2.0317e-01 -9.3270e-04 12 13 9 12 5 5 64.38 32.65 1.42 0.20317 0.83674 3 2 1 2 0 2773.796 20.01 32.65 15.53 28.00 28.25 7.9 1020.90 1160 1576 852 76 250 1036 -327 -1834 -878 -1663 -1421 -327 1679 130 -684 251 -350 300 1542 788 1141 1830 1026 -2971 -1700 -1858 -2404 602 2698 580 -114 518 -560 -718 -1061 -358 -95 900 787 1717 856 1398 1481 1523 -1051 -1658 -2476 -3266 -1439 -501 664 634 332 -433 -21 -69 735 684 1124 400 -218 335 323 -782 -1418 -492 -333 -375 1536 1288 -265 -808 -657 -821 -1546 -746 -640 -1619 112 122 91 -622 -889 -941 -913 -505 1268 2193 1464 1047 1779 1295 -465 -2215 -2169 -2491 -2228 134 2005 1005 235 667 -1403 -797 -703 -314 -338 499 629 383 1112 1934 1446 1266 458 292 -1368 -587 463 203 460 268 -117 694 2023 463 473 -530 -1981 -2929 -1380 -505 -695 -243 -67 -316 505 925 1706 1923 1666 724 -989 -1496 -1417 -1337 -294 1557 133 139 900000 1245 1651 897 82 264 1075 -337 -1874 -887 -1699 -1461 -341 1738 138 -727 266 -372 316 1626 836 1197 1904 1054 -3071 -1705 -1883 -2470 625 2826 622 -121 539 -580 -734 -1084 -367 -98 933 826 1800 897 1439 1498 1559 -1057 -1627 -2402 -3185 -1423 -497 671 647 341 -442 -21 -71 754 701 1142 403 -216 336 322 -775 -1383 -479 -327 -373 1487 1257 -256 -788 -634 -787 -1490 -727 -630 -1552 107 119 89 -611 -875 -932 -906 -503 1273 2160 1479 1041 1738 1238 -439 -2127 -2057 -2382 -2111 130 2012 992 230 658 -1376 -772 -695 -306 -334 497 630 385 1115 1941 1457 1249 448 282 -1355 -578 447 201 455 266 -116 679 1980 452 448 -501 -1877 -2772 -1326 -498 -674 -237 -66 -313 496 913 1681 1893 1629 695 -957 -1427 -1356 -1300 -290 1496 130 138 900000 SQ 20250314T183132.7Z 9204.771906 472 1 7.23 2 44.68 207.23 139.67 21.64 0.00 1 0.00 1 0 78 1.207e-02 1.203e-02 9.611e-04 9.592e-04 9.781812e+02 4.933213e+01 1.267544e+02 -6.000000e+00 6.043881e+02 278.00 -2.00 20.00 -2.00 505.25 0.00e+00 2.442411e-04 2.521106e-05 9.803829e-05 -6.000000e+00 3.243804e-04 278.00 -2.00 20.00 -2.00 500.43 0.00e+00 -3.990640e-02 1.726577e-02 3.247000e-02 -6.000000e+00 2.302864e-01 226.31 -2.00 3.47 -2.00 502.03 0.00e+00 1.405 0.000 489.00 513.00 1 4.6412e+00 1.3241e-03 3.7185e-03 -6.0000e+00 1.7539e-02 1.6956e-02 3.3475e-04 4.0641e-04 -6.0000e+00 4.6936e-03 1.5451e-02 8.7008e-02 6.5892e-05 2.0437e-05 -6.0000e+00 8.2996e-04 7.0425e-02 1.5670e-04 12 13 9 12 5 5 95.93 32.63 1.34 0.07043 0.67395 24 20 1 2 0 288.671 20.00 32.63 16.32 28.25 28.25 7.9 1023.92 1213 1460 1541 337 456 922 -352 -1525 -1390 -1714 -1663 -792 1292 465 -425 450 -104 12 1430 954 1199 2206 1201 -2800 -1826 -1574 -2628 -154 2459 1013 84 602 -252 -823 -1026 -417 -372 510 880 1405 1222 1457 1495 1176 -1013 -1651 -2719 -3195 -1409 -417 435 129 284 -606 -387 250 888 913 1007 595 106 74 414 -900 -1722 -1019 -483 -39 1302 1424 -133 -443 -695 -1091 -1581 -235 -508 -1428 -4 45 209 -643 -660 -753 -859 -715 1221 2030 1307 1333 1700 736 -222 -1982 -2421 -2513 -2129 189 2103 1055 679 8 -1671 -1436 -538 -52 -204 394 581 313 1095 1732 1658 574 942 -40 -1032 -246 929 -309 373 592 302 793 2009 357 -455 -600 -2027 -2555 -588 -131 -436 117 248 -73 199 1046 1171 1937 1599 304 -1184 -1993 -1613 -1145 307 1156 853 -195 900000 1300 1545 1628 354 479 959 -364 -1556 -1410 -1752 -1714 -830 1351 497 -455 480 -111 13 1521 996 1268 2307 1245 -2895 -1834 -1590 -2705 -156 2601 1067 88 631 -262 -850 -1057 -432 -388 523 909 1456 1258 1511 1526 1181 -1020 -1621 -2646 -3113 -1392 -416 444 131 293 -611 -397 257 896 919 1009 603 105 73 412 -893 -1685 -996 -476 -38 1275 1399 -129 -430 -670 -1048 -1524 -228 -500 -1378 -3 44 206 -636 -653 -750 -859 -703 1209 2035 1302 1303 1675 713 -210 -1898 -2302 -2406 -2035 185 2079 1056 670 8 -1654 -1411 -523 -52 -204 390 578 312 1090 1730 1653 565 932 -39 -1002 -237 908 -304 363 578 293 764 1936 342 -437 -572 -1933 -2429 -566 -127 -428 116 242 -73 195 1024 1152 1893 1586 297 -1153 -1923 -1558 -1096 297 1134 838 -189 900000 SQ 20250314T184742.7Z 9204.783133 479 1 54.18 2 46.24 212.46 138.48 27.29 0.00 1 0.00 1 0 78 1.234e-02 1.230e-02 3.234e-04 3.225e-04 1.046982e+03 1.669745e+01 1.075847e+02 -6.000000e+00 6.175308e+02 278.00 -2.00 20.00 -2.00 505.25 0.00e+00 2.459239e-04 8.465626e-06 8.644942e-05 -6.000000e+00 3.314707e-04 278.00 -2.00 20.00 -2.00 500.39 0.00e+00 -5.023655e-02 5.818566e-03 3.131049e-02 -6.000000e+00 2.353377e-01 226.32 -2.00 3.47 -2.00 502.00 0.00e+00 1.444 0.000 489.00 513.00 1 4.3125e+00 4.4497e-04 3.5648e-03 -6.0000e+00 1.7924e-02 1.4053e-02 1.1310e-04 4.0808e-04 -6.0000e+00 4.7972e-03 2.1366e-02 8.7157e-02 2.2196e-05 1.7473e-05 -6.0000e+00 8.4817e-04 7.0833e-02 1.4630e-04 12 13 9 12 4 4 99.99 32.15 1.33 0.07083 0.67539 543 58 1 2 0 99.421 20.01 32.15 16.86 28.00 28.25 7.9 1026.15 1228 1458 1478 415 468 849 -426 -1524 -1405 -1631 -1748 -675 1204 383 -265 501 -60 91 1352 999 1352 2291 1151 -2874 -2011 -1713 -2518 -203 2483 1093 227 492 -170 -920 -899 -193 -390 520 1009 1425 1251 1341 1505 1154 -887 -1634 -2886 -3242 -1596 -318 415 202 325 -682 -275 241 918 1003 1134 746 159 143 435 -987 -1946 -979 -591 -216 1299 1291 -201 -608 -797 -1199 -1534 -323 -604 -1445 -99 66 67 -706 -694 -689 -781 -534 1269 1934 1168 1412 1697 697 -307 -2134 -2580 -2845 -2118 66 2196 1019 683 4 -1713 -1424 -611 -234 -28 441 542 464 1066 1797 1782 785 861 75 -1026 -83 815 -169 394 727 261 984 2036 248 -501 -524 -2072 -2487 -717 -130 -443 -3 282 -145 255 946 1406 2047 1636 383 -1443 -1876 -1613 -1031 197 1043 853 -294 900000 1278 1535 1554 433 504 907 -452 -1595 -1463 -1709 -1850 -725 1255 408 -282 530 -64 96 1433 1062 1422 2384 1190 -2893 -2078 -1779 -2519 -206 2616 1172 241 514 -176 -947 -921 -199 -405 544 1062 1506 1314 1388 1531 1156 -868 -1649 -2893 -3250 -1539 -317 423 209 335 -702 -281 246 945 1031 1160 753 158 140 422 -956 -1860 -933 -568 -209 1269 1268 -196 -577 -750 -1125 -1442 -306 -580 -1393 -96 65 66 -699 -687 -685 -780 -536 1285 1984 1191 1410 1671 675 -291 -1998 -2399 -2668 -2023 65 2219 992 691 4 -1697 -1400 -609 -226 -27 434 536 460 1056 1784 1767 768 829 71 -1021 -82 776 -161 394 726 259 969 2010 244 -483 -500 -1980 -2368 -694 -129 -424 -3 274 -141 249 924 1375 1991 1580 364 -1412 -1813 -1563 -1012 186 998 817 -279 900000 SQ 20250314T185551.3Z 9204.788788 483 1 24.60 2 47.12 214.98 137.78 30.03 0.00 1 0.00 1 0 92 1.234e-02 1.228e-02 1.683e-03 1.678e-03 1.138285e+03 8.730791e+01 1.040231e+02 -6.000000e+00 6.175699e+02 278.00 -2.00 20.00 -2.00 505.25 0.00e+00 2.138073e-04 4.408756e-05 9.369707e-05 -6.000000e+00 3.317210e-04 278.00 -2.00 20.00 -2.00 500.36 0.00e+00 -3.508624e-02 3.032723e-02 2.743189e-02 -6.000000e+00 2.357934e-01 226.32 -2.00 3.47 -2.00 501.97 0.00e+00 1.467 0.000 489.00 513.00 1 6.8005e+00 2.3227e-03 3.4947e-03 -6.0000e+00 1.7952e-02 1.7164e-02 5.8805e-04 3.4675e-04 -6.0000e+00 4.8162e-03 1.7668e-03 9.0344e-02 1.1558e-04 1.8384e-05 -6.0000e+00 8.4837e-04 7.1644e-02 1.6391e-05 12 13 9 12 5 5 98.45 32.16 1.46 0.07164 0.69831 9 2 1 2 0 2458.852 20.00 32.16 17.05 28.25 28.50 7.8 1025.83 1083 1323 1608 423 364 739 -412 -1788 -1821 -1295 -1309 -725 1199 350 -328 819 -18 120 1300 1078 1022 2330 783 -2886 -1636 -1568 -2670 138 2195 1383 -191 524 -409 -973 -1048 -265 -153 835 877 1241 1527 1385 1350 1169 -996 -1697 -2946 -3167 -1384 -423 302 387 611 -591 -244 103 642 1049 934 682 19 10 535 -798 -1658 -744 -457 -101 1347 1269 -403 -868 -555 -1695 -1611 -187 -222 -1376 64 -209 308 -856 -748 -965 -981 -560 1007 2272 1084 1138 1809 789 -196 -2223 -2641 -2946 -1957 120 2381 1178 510 65 -1738 -1095 -500 90 218 545 548 260 1064 2010 1646 612 718 51 -1057 -196 1087 -255 403 398 355 1091 2079 249 -108 -543 -2199 -2450 -530 -78 -386 -190 34 -141 358 889 1398 1806 1854 266 -1760 -1833 -1565 -1315 595 1092 808 -280 900000 1139 1405 1701 444 375 788 -435 -1871 -1900 -1350 -1377 -744 1260 375 -351 871 -19 128 1389 1153 1086 2440 816 -2920 -1679 -1552 -2694 141 2336 1488 -204 550 -428 -1008 -1082 -275 -160 875 929 1321 1607 1441 1383 1175 -980 -1705 -2940 -3159 -1340 -424 309 401 631 -611 -250 106 666 1082 961 692 19 10 521 -774 -1586 -710 -440 -99 1321 1251 -394 -828 -523 -1604 -1521 -178 -213 -1329 62 -207 304 -851 -743 -965 -984 -564 983 2232 1062 1141 1782 764 -186 -2086 -2461 -2771 -1870 117 2308 1158 496 62 -1724 -1075 -499 88 214 542 548 261 1065 2012 1650 606 699 50 -1008 -194 1042 -247 386 383 338 1075 1968 245 -104 -519 -2104 -2333 -512 -74 -373 -185 33 -139 351 877 1379 1776 1803 255 -1727 -1771 -1515 -1294 564 1053 781 -268 900000 SQ 20250314T190019.8Z 9204.791896 487 1 20.75 2 47.63 216.34 137.37 31.50 0.00 1 0.00 1 0 92 1.218e-02 1.212e-02 1.880e-03 1.875e-03 1.296453e+03 9.822067e+01 9.867791e+01 -6.000000e+00 6.092292e+02 278.01 -2.00 20.00 -2.00 505.25 0.00e+00 2.725089e-04 4.918831e-05 9.602930e-05 -6.000000e+00 3.272387e-04 278.01 -2.00 20.00 -2.00 500.40 0.00e+00 -6.052045e-02 3.378330e-02 3.186356e-02 -6.000000e+00 2.325613e-01 226.32 -2.00 3.47 -2.00 502.01 0.00e+00 1.481 0.000 489.00 513.00 1 6.8443e+00 2.5854e-03 3.7321e-03 -6.0000e+00 1.7707e-02 1.4488e-02 6.5504e-04 4.2178e-04 -6.0000e+00 4.7484e-03 1.6895e-03 9.0045e-02 1.2905e-04 1.8553e-05 -6.0000e+00 8.3719e-04 6.4179e-02 8.6302e-05 12 13 9 12 5 5 98.51 32.12 1.46 0.06418 0.68877 7 2 1 2 0 2592.413 19.99 32.12 16.93 28.25 28.50 7.8 1024.74 1412 1566 1402 543 312 944 -369 -1924 -1326 -1757 -1752 -507 1010 590 -552 715 -307 182 1352 631 1141 2174 732 -3099 -1693 -1891 -2638 -33 2351 1052 368 608 60 -1041 -881 -468 -89 769 1054 1537 977 1521 1595 669 -798 -1449 -2956 -2844 -1181 -205 427 553 336 -651 -130 -98 582 1087 991 540 -11 309 466 -957 -1837 -838 -371 -263 1526 995 -340 -314 -1002 -1339 -1830 -263 -244 -1494 0 279 450 -564 -768 -613 -606 -610 1061 1741 1062 1358 2056 683 -569 -2070 -2674 -2703 -1946 166 2359 831 631 105 -2039 -879 -495 -457 20 560 547 815 768 1686 1389 880 1193 -220 -925 -23 763 76 290 189 302 1014 1710 196 -504 -450 -2029 -2307 -814 -55 -579 -462 68 -298 62 888 1586 2181 2061 274 -1653 -1489 -1663 -1056 407 1222 156 197 900000 1527 1644 1472 564 332 992 -386 -1991 -1360 -1817 -1829 -537 1054 626 -587 755 -326 192 1431 672 1201 2260 756 -3116 -1719 -1940 -2639 -34 2479 1126 388 634 62 -1070 -902 -483 -92 801 1107 1620 1027 1569 1619 671 -778 -1437 -2921 -2800 -1182 -203 435 568 346 -668 -133 -100 601 1115 1013 546 -11 302 452 -924 -1825 -830 -355 -255 1487 978 -330 -297 -983 -1309 -1796 -249 -233 -1439 0 274 443 -556 -759 -608 -603 -611 1075 1717 1039 1352 2009 659 -539 -1928 -2480 -2523 -1852 162 2376 818 636 105 -2021 -858 -493 -446 20 556 547 813 772 1693 1396 869 1157 -212 -917 -23 734 73 279 182 299 998 1690 192 -484 -428 -1933 -2189 -787 -55 -561 -452 67 -295 61 878 1564 2140 2002 263 -1617 -1431 -1610 -1035 388 1180 152 188 900000 SQ 20250314T190807.1Z 9204.797304 491 1 14.39 2 48.55 218.64 136.61 34.02 0.00 1 0.00 1 0 113 1.231e-02 1.225e-02 2.097e-03 2.092e-03 1.200993e+03 1.090256e+02 1.009515e+02 -6.000000e+00 6.163726e+02 278.01 -2.00 20.00 -2.00 505.25 0.00e+00 3.083537e-04 5.497786e-05 9.556070e-05 -6.000000e+00 3.310211e-04 278.01 -2.00 20.00 -2.00 500.38 0.00e+00 -7.227653e-02 3.773438e-02 2.921291e-02 -6.000000e+00 2.355464e-01 226.32 -2.00 3.47 -2.00 501.99 0.00e+00 1.508 0.000 489.00 513.00 1 6.6803e+00 2.8913e-03 3.6140e-03 -6.0000e+00 1.7930e-02 1.6177e-02 7.3083e-04 3.8149e-04 -6.0000e+00 4.8169e-03 1.9838e-03 9.2318e-02 1.4371e-04 1.8093e-05 -6.0000e+00 8.4435e-04 5.9954e-02 -1.1786e-06 12 13 9 12 5 5 29.19 32.07 1.43 0.05995 0.70031 5 2 1 2 0 2397.493 20.01 32.07 16.62 28.25 28.50 7.8 1024.46 1387 1228 1521 495 446 1020 -596 -1518 -1619 -1472 -1747 -393 1535 409 -527 113 -322 101 1392 976 1194 2199 825 -2984 -1671 -1266 -2433 -272 2404 1046 -142 674 -281 -775 -872 -365 -543 881 1057 1193 1146 1472 1565 852 -869 -1824 -2986 -3289 -1673 182 470 83 135 -690 -281 610 711 1300 1010 547 363 400 228 -913 -1813 -1089 -378 264 1564 1242 -285 -789 -526 -1426 -1459 -1 -270 -1337 -128 -160 -485 -565 -486 -991 -611 -691 1064 2232 735 1629 1933 936 -561 -2224 -2334 -2758 -1898 192 2093 1124 744 -289 -1852 -826 -397 -75 -85 349 874 443 1158 1939 1602 735 978 -155 -1075 -612 1039 -563 298 338 175 356 2024 -43 -144 -448 -2344 -2359 -950 27 -799 36 296 -53 539 620 1425 1495 2384 467 -1519 -1595 -1783 -806 245 1038 740 -64 900000 1449 1302 1605 518 474 1071 -624 -1564 -1664 -1517 -1822 -415 1602 437 -564 121 -345 108 1481 1042 1262 2299 857 -3014 -1695 -1290 -2441 -278 2546 1089 -146 705 -292 -799 -897 -378 -567 921 1079 1226 1208 1528 1597 859 -853 -1816 -2949 -3250 -1680 181 481 86 140 -713 -288 625 712 1337 1038 556 362 392 222 -887 -1737 -1043 -364 256 1530 1224 -278 -752 -513 -1394 -1424 -1 -259 -1291 -124 -158 -483 -560 -482 -991 -611 -673 1046 2213 730 1626 1902 906 -534 -2086 -2168 -2589 -1813 188 2052 1115 728 -280 -1840 -810 -383 -73 -84 351 879 447 1169 1961 1622 733 959 -151 -1036 -590 1006 -551 289 329 169 342 1936 -41 -138 -428 -2250 -2248 -923 26 -782 36 294 -52 534 619 1420 1490 2329 452 -1490 -1540 -1733 -764 236 1013 723 -62 900000