File name: Pandora241s1_Jeonju_20241002_L2Fit_fwvt1c1d20230801p1-8.txt File generation date: 20241002T153046.9Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c1p1-8 Local principal investigator: Mijung Song Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 241 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora241_OF_v2d20230410.txt Instrument calibration file used: Pandora241s1_CF_v1d20230801.txt Level 1 file used: Pandora241s1_Jeonju_20241002_L1_smca1c1d20230801p1-8.txt Full location name: Jeonbuk National University/Jeonju Short location name: Jeonju Country of location: Korea, Republic of Location latitude [deg]: 35.8466 Location longitude [deg]: 127.1307 Location altitude [m]: 40 Local noon date: 20241002 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Full lab calibration + OOB session First and last pixel inside fitting window: 1611 1760 Nominal wavelengths inside fitting window [nm]: 492.0914 492.2122 492.3329 492.4536 492.5742 492.6949 492.8156 492.9362 493.0568 493.1774 493.2979 493.4185 493.5390 493.6596 493.7801 493.9006 494.0210 494.1415 494.2619 494.3823 494.5027 494.6231 494.7435 494.8638 494.9842 495.1045 495.2248 495.3450 495.4653 495.5855 495.7058 495.8260 495.9462 496.0663 496.1865 496.3066 496.4268 496.5469 496.6670 496.7870 496.9071 497.0271 497.1471 497.2671 497.3871 497.5071 497.6270 497.7469 497.8669 497.9868 498.1066 498.2265 498.3463 498.4662 498.5860 498.7058 498.8255 498.9453 499.0650 499.1847 499.3044 499.4241 499.5438 499.6634 499.7831 499.9027 500.0223 500.1419 500.2614 500.3810 500.5005 500.6200 500.7395 500.8590 500.9784 501.0978 501.2173 501.3367 501.4561 501.5754 501.6948 501.8141 501.9334 502.0527 502.1720 502.2912 502.4105 502.5297 502.6489 502.7681 502.8873 503.0064 503.1256 503.2447 503.3638 503.4829 503.6020 503.7210 503.8400 503.9590 504.0780 504.1970 504.3160 504.4349 504.5538 504.6728 504.7916 504.9105 505.0294 505.1482 505.2670 505.3858 505.5046 505.6234 505.7421 505.8608 505.9796 506.0982 506.2169 506.3356 506.4542 506.5728 506.6914 506.8100 506.9286 507.0472 507.1657 507.2842 507.4027 507.5212 507.6396 507.7581 507.8765 507.9949 508.1133 508.2317 508.3500 508.4684 508.5867 508.7050 508.8233 508.9415 509.0598 509.1780 509.2962 509.4144 509.5326 509.6507 509.7689 509.8870 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-401: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20241002T084527.2Z 9041.364898 5 1 19.99 2 85.13 261.71 88.20 265.69 0.00 1 0.00 1 0 22 4.897e-03 4.872e-03 1.262e-04 1.262e-04 4.276531e+03 8.423167e+00 2.878734e+02 -6.000000e+00 2.940168e+02 288.99 -2.00 20.00 -2.00 505.28 0.00e+00 4.083602e-03 3.633851e-06 2.280765e-04 -6.000000e+00 1.432325e-04 288.99 -2.00 20.00 -2.00 500.61 0.00e+00 6.815081e-01 2.558625e-03 4.605582e-02 -6.000000e+00 1.007174e-01 227.80 -2.00 3.41 -2.00 502.17 0.00e+00 9.995 0.016 489.00 513.00 1 1.3539e+00 1.9630e-04 1.5914e-02 -6.0000e+00 7.7366e-03 -2.4174e-02 5.0588e-05 1.1162e-03 -6.0000e+00 2.0185e-03 1.0909e-01 -2.1917e-03 1.4810e-05 1.0543e-04 -6.0000e+00 5.9076e-04 -2.9930e-02 -6.0960e-04 12 8 8 10 0 0 17.49 24.80 2.43 -0.02993 -0.04513 508 508 1 2 0 39.330 20.00 24.80 26.19 33.75 32.00 0.4 1008.12 900000 -1183 -884 -318 113 337 611 897 867 714 461 269 39 -250 -373 -334 -283 -115 235 503 437 350 434 408 502 616 486 346 151 -362 -893 -864 -763 -570 -1 257 5 -149 -143 -269 -353 -204 0 160 336 546 591 502 290 29 -344 -812 -1047 -1151 -982 -539 -138 118 233 300 327 462 619 643 596 536 324 73 -54 -197 -407 -466 -339 -295 -136 68 -53 -335 -515 -539 -646 -669 -542 -541 -545 -312 -239 -315 -319 -232 -118 -6 242 628 691 589 506 373 -19 -425 -742 -931 -905 -682 -254 -22 -187 -306 -427 -470 -337 -42 204 391 626 819 857 947 956 740 511 344 114 -33 104 167 74 132 195 122 235 254 -101 -310 -386 -590 -578 -258 -89 -66 136 304 326 368 392 349 213 4 -415 -786 900000 -1123 -842 -307 111 336 614 903 879 716 464 267 38 -246 -367 -327 -276 -114 234 504 440 355 441 412 509 627 496 351 152 -362 -886 -847 -751 -565 -1 261 5 -151 -144 -273 -357 -206 0 161 344 558 606 514 297 30 -345 -807 -1035 -1133 -964 -534 -138 120 236 306 334 472 635 655 608 544 329 73 -54 -195 -404 -460 -335 -291 -135 68 -53 -331 -503 -527 -630 -654 -527 -530 -533 -308 -236 -313 -314 -228 -116 -6 241 630 689 590 500 366 -18 -410 -707 -886 -870 -663 -248 -22 -187 -305 -423 -466 -335 -42 204 393 637 832 877 966 977 755 518 349 115 -33 104 167 75 134 197 122 238 255 -100 -309 -382 -585 -573 -257 -90 -67 139 312 334 379 402 357 219 4 -421 -789 SQ 20241002T084547.4Z 9041.365132 5 2 19.99 2 85.20 261.76 88.27 265.74 0.00 1 0.00 1 0 22 4.909e-03 4.883e-03 1.281e-04 1.281e-04 4.314725e+03 8.560126e+00 2.904385e+02 -6.000000e+00 2.947268e+02 288.99 -2.00 20.00 -2.00 505.28 0.00e+00 4.079198e-03 3.690863e-06 2.279614e-04 -6.000000e+00 1.435736e-04 288.99 -2.00 20.00 -2.00 500.61 0.00e+00 6.848404e-01 2.596839e-03 4.621104e-02 -6.000000e+00 1.009535e-01 227.80 -2.00 3.41 -2.00 502.17 0.00e+00 10.096 0.016 489.00 513.00 1 1.3692e+00 1.9926e-04 1.6056e-02 -6.0000e+00 7.7549e-03 -2.4338e-02 5.1327e-05 1.1258e-03 -6.0000e+00 2.0230e-03 1.0588e-01 -2.3662e-03 1.5023e-05 1.0534e-04 -6.0000e+00 5.9214e-04 -3.0049e-02 -5.9974e-04 12 8 8 10 0 0 9.00 24.80 2.45 -0.03005 -0.04646 508 508 1 2 0 39.330 20.00 24.80 26.19 33.75 32.00 0.4 1007.82 900000 -1187 -870 -327 129 308 633 881 865 718 467 251 59 -246 -368 -336 -257 -108 221 504 413 360 439 418 493 618 489 329 123 -382 -934 -833 -738 -574 -19 262 19 -135 -146 -276 -356 -226 18 139 369 542 590 489 300 37 -337 -818 -1057 -1149 -995 -565 -148 126 234 305 355 472 631 640 601 537 330 90 -75 -193 -408 -451 -322 -298 -140 68 -54 -336 -543 -526 -655 -677 -543 -538 -539 -317 -253 -312 -310 -216 -95 -37 228 592 713 616 510 382 -25 -417 -733 -958 -902 -676 -240 -37 -175 -323 -383 -475 -295 -15 139 380 646 806 867 938 981 734 481 338 97 -35 98 146 71 151 194 132 236 255 -116 -323 -419 -590 -572 -260 -85 -58 121 316 332 387 415 336 255 -4 -449 -788 900000 -1126 -827 -315 126 307 635 886 876 727 469 249 58 -241 -362 -330 -251 -107 220 505 415 363 445 421 499 627 497 334 124 -382 -926 -816 -726 -569 -19 265 19 -136 -148 -278 -359 -228 18 142 377 553 604 499 307 37 -338 -812 -1044 -1130 -976 -558 -148 127 239 310 362 483 647 652 612 549 335 90 -75 -192 -405 -445 -319 -294 -140 68 -54 -331 -535 -514 -639 -661 -532 -527 -532 -311 -250 -310 -308 -213 -93 -37 227 593 717 617 503 374 -24 -402 -698 -910 -866 -656 -237 -37 -174 -322 -379 -470 -293 -15 139 382 655 817 886 955 1001 749 491 342 98 -35 99 146 72 152 196 134 238 255 -116 -322 -414 -585 -567 -260 -85 -59 123 324 340 398 428 346 261 -4 -456 -791 SQ 20241002T085009.0Z 9041.368160 8 1 29.99 2 86.08 262.41 89.14 266.35 0.00 1 0.00 1 0 22 5.523e-03 5.489e-03 1.378e-04 1.377e-04 5.108521e+03 9.316312e+00 3.357244e+02 -6.000000e+00 3.315653e+02 288.99 -2.00 20.00 -2.00 505.30 0.00e+00 5.111746e-03 3.974918e-06 2.854056e-04 -6.000000e+00 1.615071e-04 288.99 -2.00 20.00 -2.00 500.69 0.00e+00 7.323555e-01 2.786998e-03 5.729941e-02 -6.000000e+00 1.135541e-01 227.80 -2.00 3.41 -2.00 502.23 0.00e+00 11.568 0.025 489.00 513.00 1 1.6865e+00 2.1380e-04 1.8834e-02 -6.0000e+00 8.7233e-03 -3.0186e-02 5.4943e-05 1.3349e-03 -6.0000e+00 2.2751e-03 6.1346e-02 -2.8950e-03 1.6164e-05 1.3124e-04 -6.0000e+00 6.6613e-04 -1.1222e-02 -6.9721e-04 12 8 8 10 0 0 32.23 24.78 3.09 -0.01122 -0.03130 477 477 1 2 0 62.860 20.00 24.78 25.96 34.00 32.25 0.4 1006.68 900000 -1369 -969 -401 127 379 711 993 937 814 518 295 36 -281 -428 -421 -362 -148 243 549 441 376 483 491 551 694 577 369 170 -394 -978 -965 -820 -613 -33 281 92 -139 -144 -291 -355 -212 -1 179 422 619 672 569 304 38 -368 -864 -1158 -1273 -1075 -611 -124 146 294 348 422 531 675 716 688 607 372 90 -52 -215 -449 -533 -412 -344 -176 24 -103 -432 -581 -613 -725 -770 -668 -600 -624 -384 -300 -355 -327 -291 -129 -27 288 651 805 686 590 410 -46 -455 -865 -1058 -1045 -772 -269 -30 -200 -339 -467 -513 -351 -40 220 454 741 951 963 1058 1105 861 570 393 130 -9 142 189 102 200 256 177 230 271 -135 -373 -499 -665 -650 -302 -116 -68 107 323 357 390 403 361 245 -13 -463 -891 900000 -1287 -912 -382 123 371 702 993 934 810 512 292 35 -275 -415 -407 -353 -144 238 546 440 377 481 491 553 700 577 369 170 -388 -958 -945 -797 -606 -33 284 93 -141 -144 -290 -354 -213 -1 181 427 632 689 583 309 39 -367 -856 -1144 -1253 -1055 -604 -124 147 300 353 429 543 692 736 707 621 377 91 -52 -213 -448 -529 -409 -340 -175 24 -103 -427 -569 -602 -710 -756 -651 -589 -618 -379 -297 -353 -325 -289 -127 -27 289 651 807 685 587 404 -45 -438 -824 -1006 -1004 -749 -265 -30 -199 -337 -463 -508 -349 -39 222 461 752 974 985 1089 1141 888 585 399 133 -9 144 191 104 204 260 180 234 274 -136 -376 -499 -667 -650 -306 -119 -70 109 334 368 405 420 376 254 -13 -473 -903 SQ 20241002T085646.4Z 9041.372759 10 1 29.96 2 87.41 263.39 90.46 267.27 0.00 1 0.00 1 0 29 7.217e-03 7.164e-03 2.370e-04 2.367e-04 6.333821e+03 1.622083e+01 3.986981e+02 -6.000000e+00 4.332612e+02 288.99 -2.00 20.00 -2.00 505.33 0.00e+00 6.070261e-03 6.846294e-06 3.396860e-04 -6.000000e+00 2.109672e-04 288.99 -2.00 20.00 -2.00 500.84 0.00e+00 7.082389e-01 4.764879e-03 7.140632e-02 -6.000000e+00 1.482825e-01 227.80 -2.00 3.41 -2.00 502.36 0.00e+00 14.464 0.048 489.00 513.00 1 2.3261e+00 3.6526e-04 2.4004e-02 -6.0000e+00 1.1394e-02 -3.9681e-02 9.3581e-05 1.7036e-03 -6.0000e+00 2.9681e-03 2.1176e-02 -4.6258e-03 2.7750e-05 1.5569e-04 -6.0000e+00 8.7087e-04 1.5305e-02 -7.8399e-04 12 8 8 10 0 0 32.91 24.76 5.17 0.01531 -0.01678 198 198 1 2 0 151.280 20.00 24.76 25.80 33.75 32.00 0.4 1004.98 900000 -1832 -1329 -573 144 473 946 1273 1259 1055 676 359 7 -442 -643 -701 -520 -259 263 586 538 513 575 590 713 888 715 536 207 -469 -1200 -1204 -1063 -761 -85 356 151 22 -71 -328 -351 -189 3 336 620 850 890 727 468 85 -440 -1073 -1435 -1601 -1369 -712 -163 291 445 529 577 744 941 935 888 785 479 166 -108 -324 -617 -725 -582 -498 -248 -62 -252 -581 -809 -922 -983 -1011 -845 -797 -779 -525 -367 -451 -456 -368 -165 19 397 839 1037 899 801 473 -90 -625 -1057 -1365 -1325 -975 -332 -83 -196 -394 -560 -684 -446 -24 275 601 1015 1241 1331 1411 1474 1118 759 507 250 82 192 274 157 294 323 232 247 286 -196 -589 -659 -879 -873 -450 -213 -73 147 392 436 455 507 445 281 -130 -626 -1131 900000 -1682 -1237 -537 136 454 910 1240 1234 1034 658 346 6 -424 -613 -667 -498 -247 255 569 529 501 564 581 705 871 705 527 205 -458 -1154 -1162 -1031 -741 -83 351 151 22 -70 -325 -348 -187 3 337 622 860 906 740 473 85 -440 -1056 -1413 -1573 -1338 -708 -164 294 454 536 587 759 964 962 903 805 488 167 -108 -325 -615 -720 -579 -492 -246 -62 -251 -575 -804 -909 -967 -996 -835 -783 -772 -523 -362 -447 -452 -365 -164 19 396 841 1043 901 800 465 -88 -602 -1021 -1318 -1276 -947 -326 -83 -196 -395 -561 -685 -450 -24 277 615 1036 1278 1384 1460 1531 1164 786 521 258 85 198 280 162 304 335 240 256 295 -201 -600 -668 -893 -895 -461 -222 -76 153 412 462 479 535 470 296 -138 -654 -1173 SQ 20241002T090044.6Z 9041.375516 16 1 29.96 2 88.21 263.97 91.25 267.83 0.00 1 0.00 1 0 36 9.924e-03 9.789e-03 4.067e-04 4.054e-04 6.959406e+03 2.791442e+01 4.082042e+02 -6.000000e+00 5.957488e+02 288.99 -2.00 20.00 -2.00 505.36 0.00e+00 6.521291e-03 1.174961e-05 3.621976e-04 -6.000000e+00 2.898462e-04 288.99 -2.00 20.00 -2.00 500.94 0.00e+00 5.543602e-01 8.095105e-03 8.029386e-02 -6.000000e+00 2.031034e-01 227.80 -2.00 3.41 -2.00 502.45 0.00e+00 16.530 0.072 489.00 513.00 1 3.0659e+00 6.2071e-04 2.7991e-02 -6.0000e+00 1.5625e-02 -4.6774e-02 1.5774e-04 1.9663e-03 -6.0000e+00 4.0380e-03 7.5646e-03 -7.4675e-03 4.7181e-05 1.5427e-04 -6.0000e+00 1.1942e-03 1.6750e-02 -6.7106e-04 12 8 8 10 0 0 25.54 24.75 8.26 0.01675 -0.03505 126 126 1 2 0 237.710 20.00 24.75 25.16 34.00 32.00 0.5 1003.94 -2518 -2663 -1952 -937 -23 585 1293 1671 1812 1471 1067 498 -35 -545 -876 -932 -834 -467 160 699 737 737 728 822 1028 1111 1045 790 354 -468 -1469 -1631 -1448 -1057 -73 436 425 240 55 -247 -300 -173 125 561 854 1215 1276 1151 838 200 -455 -1252 -1804 -1944 -1645 -946 -112 431 747 821 935 1038 1261 1296 1243 1171 681 325 -128 -412 -812 -921 -882 -683 -383 -131 -419 -872 -1158 -1218 -1361 -1440 -1251 -1070 -931 -619 -564 -544 -501 -337 -183 121 628 1114 1387 1265 1097 679 -50 -817 -1360 -1831 -1695 -1211 -470 -65 -138 -393 -614 -794 -589 -121 330 881 1264 1625 1815 1785 1851 1538 1109 674 381 96 306 370 306 432 441 290 347 286 -287 -814 -1039 -1283 -1135 -712 -358 -112 124 394 412 465 488 400 210 -302 -933 -1568 -2274 -2401 -1780 -855 -22 549 1232 1580 1724 1401 1010 477 -34 -515 -822 -873 -786 -437 151 672 704 708 704 797 1003 1091 1012 764 340 -453 -1406 -1548 -1380 -1024 -71 430 416 235 53 -241 -293 -169 124 553 853 1225 1294 1167 846 200 -450 -1222 -1776 -1909 -1599 -936 -111 435 762 829 948 1056 1288 1330 1277 1198 694 328 -128 -410 -804 -909 -873 -680 -384 -132 -421 -872 -1148 -1198 -1336 -1418 -1236 -1063 -932 -612 -561 -543 -499 -335 -182 121 636 1117 1393 1265 1101 670 -49 -798 -1317 -1775 -1632 -1189 -463 -65 -138 -395 -618 -800 -598 -124 337 912 1301 1686 1900 1885 1933 1610 1157 710 399 100 319 382 319 451 462 305 364 299 -299 -844 -1074 -1329 -1186 -741 -378 -118 132 423 446 498 524 431 225 -321 -1000 -1672 SQ 20241002T090445.1Z 9041.378300 22 1 29.83 2 89.02 264.56 92.05 268.38 0.00 1 0.00 1 0 43 1.416e-02 1.391e-02 7.435e-04 7.395e-04 7.263213e+03 5.071965e+01 3.897127e+02 -6.000000e+00 8.498034e+02 288.99 -2.00 20.00 -2.00 505.40 0.00e+00 6.819761e-03 2.145960e-05 3.760226e-04 -6.000000e+00 4.131836e-04 288.99 -2.00 20.00 -2.00 501.11 0.00e+00 1.950937e-01 1.465845e-02 8.998320e-02 -6.000000e+00 2.894070e-01 227.80 -2.00 3.41 -2.00 502.59 0.00e+00 18.585 0.103 489.00 513.00 1 3.8979e+00 1.1236e-03 3.2522e-02 -6.0000e+00 2.2272e-02 -4.5635e-02 2.8466e-04 2.2544e-03 -6.0000e+00 5.7451e-03 2.5179e-03 -9.4790e-03 8.6029e-05 1.6244e-04 -6.0000e+00 1.7049e-03 1.3371e-02 -5.2352e-04 12 8 8 10 0 0 37.84 24.75 12.90 0.01337 -0.05238 69 69 1 2 0 432.180 20.00 24.75 24.83 34.00 32.25 0.5 1002.44 -3659 -3821 -2834 -1695 -301 819 1625 2203 2330 1882 1392 670 -36 -856 -1482 -1757 -1381 -902 135 764 964 977 1036 1252 1287 1702 1577 1138 512 -691 -2078 -2396 -2052 -1341 -84 661 708 645 281 -124 -293 64 392 914 1436 1849 2024 1762 1184 482 -431 -1600 -2517 -2578 -2221 -1211 8 742 1216 1266 1387 1653 1918 1959 1957 1584 1212 326 -191 -694 -1118 -1471 -1298 -1003 -628 -393 -608 -1114 -1808 -1945 -2053 -1972 -1715 -1456 -1380 -893 -643 -552 -508 -493 -137 177 844 1666 1950 1817 1351 793 -90 -1102 -1980 -2462 -2119 -1479 -480 -9 -17 -463 -931 -1055 -734 -149 611 1271 1887 2321 2526 2612 2545 2107 1370 851 492 187 398 617 522 538 608 347 417 40 -347 -1260 -1559 -1807 -1775 -1078 -504 -135 197 449 487 664 734 643 205 -616 -1479 -2308 -3243 -3387 -2536 -1548 -273 755 1521 2027 2157 1745 1285 615 -34 -799 -1343 -1595 -1258 -831 126 721 919 913 972 1179 1221 1622 1509 1091 489 -654 -1954 -2238 -1924 -1276 -81 633 685 625 271 -120 -284 63 386 887 1410 1832 2016 1758 1179 476 -422 -1554 -2431 -2485 -2161 -1196 8 738 1223 1283 1411 1687 1965 1970 1970 1593 1212 333 -194 -701 -1126 -1481 -1308 -992 -625 -393 -607 -1108 -1791 -1914 -2017 -1940 -1694 -1446 -1382 -898 -649 -558 -514 -499 -139 177 846 1678 1967 1824 1342 795 -89 -1079 -1929 -2404 -2088 -1450 -480 -9 -17 -470 -947 -1076 -754 -155 627 1318 1974 2447 2685 2739 2684 2230 1450 896 515 196 417 648 553 573 648 372 447 43 -369 -1339 -1652 -1923 -1867 -1144 -542 -146 216 486 531 728 807 707 226 -675 -1610 -2505