File name: Pandora167s1_KenoshaWI_20210811_L2Fit_fsus1c11d20201111p1-8.txt File generation date: 20241129T201211.6Z Data description: Level 2 spectral fitting results file Data file version: fsus1c11p1-8 Local principal investigator: Luke Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 167 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora167_OF_v4d20200117.txt Instrument calibration file used: Pandora167s1_CF_v11d20201111.txt Level 1 file used: Pandora167s1_KenoshaWI_20210811_L1_smca1c11d20201111p1-8.txt Full location name: Chiwaukee Prairie WDNR Short location name: KenoshaWI Country of location: United States Location latitude [deg]: 42.5047 Location longitude [deg]: -87.8093 Location altitude [m]: 181 Local noon date: 20210811 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 231 375 Nominal wavelengths inside fitting window [nm]: 306.1282 306.2691 306.4099 306.5508 306.6916 306.8325 306.9733 307.1141 307.2549 307.3957 307.5365 307.6773 307.8180 307.9588 308.0995 308.2402 308.3810 308.5217 308.6624 308.8030 308.9437 309.0844 309.2250 309.3656 309.5063 309.6469 309.7875 309.9281 310.0686 310.2092 310.3498 310.4903 310.6308 310.7714 310.9119 311.0524 311.1929 311.3333 311.4738 311.6143 311.7547 311.8951 312.0356 312.1760 312.3164 312.4567 312.5971 312.7375 312.8778 313.0182 313.1585 313.2988 313.4391 313.5794 313.7197 313.8600 314.0002 314.1405 314.2807 314.4209 314.5611 314.7013 314.8415 314.9817 315.1219 315.2620 315.4022 315.5423 315.6824 315.8225 315.9626 316.1027 316.2428 316.3828 316.5229 316.6629 316.8030 316.9430 317.0830 317.2230 317.3630 317.5029 317.6429 317.7828 317.9228 318.0627 318.2026 318.3425 318.4824 318.6223 318.7622 318.9020 319.0418 319.1817 319.3215 319.4613 319.6011 319.7409 319.8807 320.0204 320.1602 320.2999 320.4396 320.5794 320.7191 320.8587 320.9984 321.1381 321.2778 321.4174 321.5570 321.6967 321.8363 321.9759 322.1154 322.2550 322.3946 322.5341 322.6737 322.8132 322.9527 323.0922 323.2317 323.3712 323.5107 323.6501 323.7896 323.9290 324.0684 324.2078 324.3472 324.4866 324.6260 324.7654 324.9047 325.0441 325.1834 325.3227 325.4620 325.6013 325.7406 325.8798 326.0191 326.1583 326.2976 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210811T214316.9Z 7893.905057 5 1 50.40 2 55.57 258.29 41.80 204.52 0.00 1 0.00 1 0 66 1.645e-03 1.205e-03 5.103e-04 2.307e-04 -1.857554e-07 8.710912e-08 1.575694e-08 4.351909e-07 7.784149e-07 231.95 -2.00 3.54 -2.00 321.54 0.00e+00 5.485008e-04 3.072544e-05 1.333283e-05 5.498405e-05 2.018219e-04 288.24 -2.00 20.00 -2.00 321.32 0.00e+00 5.065745e-05 4.254256e-05 2.677495e-06 2.895570e-05 3.493127e-04 288.24 -2.00 20.00 -2.00 321.45 0.00e+00 2.448822e-04 5.846347e-05 8.992608e-06 1.891073e-05 3.682526e-04 288.24 -2.00 20.00 -2.00 321.42 0.00e+00 2.220572e-01 3.355001e-04 2.338162e-05 1.574458e-03 2.037759e-03 247.11 0.39 0.00 1.18 3.59 317.72 0.00e+00 7.037795e-05 1.807556e-05 4.028952e-06 1.840870e-05 5.485610e-05 288.24 -2.00 20.00 -2.00 316.50 0.00e+00 1.763 0.000 303.00 329.40 4 7.3197e-01 1.0926e-03 1.6792e-02 2.4792e-03 6.4635e-03 -1.9018e-02 1.3729e-03 1.7297e-03 8.1088e-04 6.9321e-03 9.2874e-03 7.0425e-04 1.9514e-04 3.0230e-04 3.8226e-03 -3.3413e-03 2.8708e-04 1.0371e-04 6.3816e-05 1.5181e-03 -2.1714e-04 1.8734e-04 1.9647e-05 6.0011e-05 9.8528e-04 4.0241e-02 -4.8283e-04 1.8446e-04 5.5572e-05 4.7185e-05 6.1581e-04 8.4861e-04 7.2600e-06 1.9624e-06 8.4130e-07 5.2835e-05 3.1569e-02 0.0000e+00 -1.6505e-01 2.2284e-02 1.6806e-03 8.8305e-04 1.3823e-01 11 8 0 10 0 0 55.28 25.22 0.24 0.03157 0.03804 1223 229 1 5 0 40.900 27.45 19.99 25.22 34.89 41.0 988.89 536 541 -190 270 -234 57 375 -160 95 10 -73 102 -257 -44 121 -103 -196 150 -72 -19 -185 3 -58 -151 582 -341 -129 12 -292 -65 -24 -38 -168 32 38 -158 244 -48 -21 122 -242 -15 110 -105 135 12 -76 209 -37 118 13 -147 99 48 54 233 -152 191 9 -304 312 -175 -77 145 -109 231 27 55 59 -291 213 -153 9 193 -343 38 -62 -71 -28 -62 94 -49 161 -141 29 -5 -27 -107 -39 264 -90 11 57 -80 -58 219 -200 -71 -1 -176 38 -64 88 -59 95 24 -42 122 -38 -10 88 -34 17 -16 181 -102 287 -125 -93 193 -16 68 11 -56 -87 65 -35 -160 69 16 17 3 24 -144 99 -149 63 -56 -50 96 -117 81 25 -126 136 75 81 -29 41 -39 11 78 -37 23 3 -18 26 -69 -12 32 -29 -58 46 -22 -6 -51 1 -16 -45 185 -116 -43 4 -99 -25 -11 -18 -88 17 22 -90 138 -27 -12 67 -130 -8 60 -62 83 8 -50 141 -25 82 9 -100 68 35 39 180 -120 141 7 -218 229 -134 -64 126 -96 196 22 41 44 -203 151 -122 7 174 -332 38 -61 -75 -31 -70 107 -54 166 -144 27 -5 -25 -110 -40 300 -110 13 66 -86 -59 227 -227 -85 -1 -214 47 -84 122 -83 129 30 -54 144 -44 -13 107 -44 23 -21 233 -127 364 -153 -109 222 -20 84 15 -74 -117 91 -51 -232 102 24 26 4 35 -206 147 -214 96 -92 -82 169 -206 146 45 -231 243 SS 20210811T214842.2Z 7893.908822 8 1 50.16 2 56.55 259.33 42.24 206.39 0.00 1 0.00 1 0 66 1.519e-03 1.099e-03 5.618e-04 2.442e-04 -3.850723e-07 9.251833e-08 1.672225e-08 4.351807e-07 7.185557e-07 231.95 -2.00 3.54 -2.00 321.62 0.00e+00 6.130999e-04 3.266617e-05 1.478330e-05 5.498527e-05 1.859075e-04 288.24 -2.00 20.00 -2.00 321.42 0.00e+00 6.125778e-05 4.495916e-05 2.042202e-06 2.895047e-05 3.223676e-04 288.24 -2.00 20.00 -2.00 321.50 0.00e+00 1.346572e-04 6.281478e-05 7.464163e-06 1.880823e-05 3.400672e-04 288.24 -2.00 20.00 -2.00 321.49 0.00e+00 2.274272e-01 3.593536e-04 2.390815e-05 1.574526e-03 1.884346e-03 246.30 0.40 0.00 1.15 3.31 317.84 0.00e+00 6.684904e-05 1.967741e-05 2.806551e-06 1.841210e-05 5.069265e-05 288.24 -2.00 20.00 -2.00 316.61 0.00e+00 1.808 0.000 303.00 329.40 4 7.8933e-01 1.1491e-03 1.7221e-02 2.4804e-03 5.9679e-03 -2.1465e-02 1.4655e-03 1.7737e-03 8.1608e-04 6.4069e-03 9.6863e-03 7.5156e-04 2.0195e-04 3.0642e-04 3.5266e-03 -3.7625e-03 3.1188e-04 1.0415e-04 6.6488e-05 1.4074e-03 1.0545e-04 2.0202e-04 1.9385e-05 6.1457e-05 9.1753e-04 3.6240e-02 -1.2456e-03 1.9277e-04 6.0402e-05 4.5998e-05 5.4315e-04 8.2797e-04 7.7294e-06 2.0507e-06 8.2865e-07 4.8601e-05 2.3727e-02 0.0000e+00 -1.0289e-01 2.3285e-02 1.8650e-03 8.7574e-04 1.2582e-01 11 8 0 10 0 0 51.20 24.68 0.24 0.02373 0.03004 1152 216 1 5 0 43.460 27.05 19.99 24.68 36.02 39.2 988.19 624 -14 120 284 160 243 98 80 -135 204 -155 188 -285 -283 80 -281 78 -30 -43 -19 -216 2 -229 82 479 -305 25 -33 -334 -43 70 -119 -117 12 -14 -68 170 43 -49 139 -184 -74 200 -164 122 -14 -39 250 -38 98 -29 -47 49 1 79 193 -56 22 57 -295 307 -156 -117 132 -128 215 -63 89 27 -269 210 -185 78 127 -248 58 -31 -58 -64 -29 73 -30 149 -66 -2 -18 4 -128 -29 200 -81 20 43 -66 -64 236 -180 -45 -13 -182 38 -80 105 -41 78 19 -62 89 -37 26 81 -49 -2 -3 195 -114 291 -119 -93 151 -45 55 -12 -14 -60 65 -46 -125 58 -8 23 -3 24 -109 80 -128 29 -33 -34 89 -107 79 44 -141 126 82 -2 17 41 25 43 19 17 -31 47 -37 47 -73 -72 20 -75 22 -9 -13 -5 -58 1 -61 23 147 -101 8 -10 -110 -16 30 -55 -60 7 -8 -38 94 24 -27 74 -97 -38 107 -94 73 -9 -25 165 -26 67 -19 -32 33 1 56 146 -44 16 41 -209 221 -117 -96 114 -111 182 -51 66 20 -186 147 -145 63 113 -238 58 -30 -60 -70 -32 82 -33 153 -68 -2 -16 4 -130 -30 226 -98 24 49 -71 -66 244 -204 -54 -16 -221 47 -105 146 -58 107 24 -73 106 -44 31 98 -64 -3 -4 253 -144 370 -146 -110 174 -55 68 -15 -19 -82 90 -67 -182 86 -13 36 -4 35 -157 119 -185 44 -55 -56 157 -199 143 82 -260 228 SS 20210811T215359.9Z 7893.912498 11 1 50.34 2 57.51 260.34 42.70 208.18 0.00 1 0.00 1 0 66 1.351e-03 9.050e-04 6.123e-04 2.552e-04 -2.984715e-07 9.653662e-08 1.791858e-08 4.351945e-07 6.386721e-07 231.95 -2.00 3.54 -2.00 321.69 0.00e+00 6.496614e-04 3.430054e-05 1.564384e-05 5.498649e-05 1.647905e-04 288.24 -2.00 20.00 -2.00 321.48 0.00e+00 5.493998e-05 4.698339e-05 3.332510e-06 2.894721e-05 2.865126e-04 288.24 -2.00 20.00 -2.00 321.55 0.00e+00 2.331166e-04 6.662244e-05 8.436487e-06 1.870927e-05 3.023062e-04 288.24 -2.00 20.00 -2.00 321.54 0.00e+00 2.323500e-01 3.797703e-04 2.072560e-05 1.574587e-03 1.677174e-03 245.47 0.42 0.00 1.12 2.94 317.95 0.00e+00 5.852945e-05 2.116544e-05 2.592858e-06 1.841593e-05 4.510471e-05 288.24 -2.00 20.00 -2.00 316.72 0.00e+00 1.855 0.000 303.00 329.40 4 8.2230e-01 1.1921e-03 1.7668e-02 2.4816e-03 5.3060e-03 -2.5619e-02 1.5433e-03 1.8194e-03 8.2123e-04 5.6991e-03 1.2019e-02 7.9153e-04 2.0733e-04 3.1068e-04 3.1310e-03 -5.2109e-03 3.3526e-04 1.0608e-04 6.9498e-05 1.2578e-03 5.4236e-04 2.1537e-04 1.7737e-05 6.3119e-05 8.2424e-04 3.3314e-02 -1.7795e-03 1.9871e-04 6.2968e-05 4.4798e-05 4.5999e-04 8.2647e-04 8.0710e-06 2.1198e-06 8.2304e-07 4.3078e-05 1.7797e-02 0.0000e+00 -1.2734e-01 2.3995e-02 1.9494e-03 8.6309e-04 1.1024e-01 10 0 0 10 0 0 27.14 24.31 0.25 0.01780 0.02410 1079 202 1 5 0 46.430 26.73 19.99 24.31 36.69 38.2 988.04 517 236 127 477 312 84 354 -12 26 170 -190 67 -306 -40 93 -156 -75 -29 -40 -37 -188 -140 -117 -36 306 -220 -73 -92 -314 -81 -59 -60 -146 -33 14 -128 205 -19 -85 159 -67 30 81 -147 91 14 16 176 -12 106 12 -23 44 58 34 237 -122 35 37 -262 261 -127 -62 99 -62 150 9 70 19 -218 118 -109 44 117 -197 11 -56 -2 -22 -62 59 -17 135 -66 -24 -32 -42 -135 12 158 -66 9 45 -88 -61 218 -173 -56 -30 -113 9 -38 73 -35 60 -3 -14 56 -4 10 79 -14 -14 1 136 -77 230 -50 -110 124 -27 36 46 1 -60 36 -40 -83 43 -13 10 -18 38 -121 84 -91 32 -61 -45 97 -86 69 9 -102 111 64 32 17 65 46 14 66 -2 6 38 -44 16 -75 -10 23 -40 -20 -8 -11 -10 -49 -35 -30 -10 91 -71 -23 -28 -100 -29 -25 -27 -72 -17 8 -69 110 -10 -45 83 -34 15 42 -82 54 9 10 114 -8 71 8 -15 29 41 24 176 -94 26 27 -183 186 -94 -50 84 -53 125 7 51 14 -150 82 -84 35 103 -188 11 -54 -2 -23 -69 67 -18 139 -67 -23 -29 -39 -137 12 178 -80 11 53 -96 -62 225 -195 -67 -37 -136 12 -50 100 -49 82 -4 -17 67 -4 12 96 -18 -19 1 176 -97 294 -62 -130 144 -33 45 60 1 -82 50 -59 -121 64 -20 16 -28 57 -176 127 -131 50 -100 -76 171 -162 127 16 -190 202 SS 20210811T215925.9Z 7893.916272 14 1 50.20 2 58.50 261.36 43.20 209.99 0.00 1 0.00 1 0 66 1.388e-03 7.747e-04 6.768e-04 2.706e-04 -5.275639e-07 1.020881e-07 2.468869e-08 4.352112e-07 6.562555e-07 231.95 -2.00 3.54 -2.00 321.75 0.00e+00 6.945100e-04 3.650709e-05 2.085869e-05 5.498738e-05 1.689614e-04 288.24 -2.00 20.00 -2.00 321.56 0.00e+00 -5.250043e-05 4.969856e-05 3.580288e-06 2.893996e-05 2.944184e-04 288.24 -2.00 20.00 -2.00 321.59 0.00e+00 1.463173e-04 7.144511e-05 1.149373e-05 1.863883e-05 3.105821e-04 288.24 -2.00 20.00 -2.00 321.60 0.00e+00 2.381738e-01 4.072767e-04 3.829094e-05 1.574629e-03 1.725043e-03 245.73 0.43 0.00 1.09 3.02 318.07 0.00e+00 7.785475e-05 2.309461e-05 8.509441e-06 1.841946e-05 4.636740e-05 288.24 -2.00 20.00 -2.00 316.84 0.00e+00 1.907 0.000 303.00 329.40 4 8.7585e-01 1.2719e-03 1.8158e-02 2.4827e-03 5.4528e-03 -2.6016e-02 1.6595e-03 1.8895e-03 8.2578e-04 5.8580e-03 1.3323e-02 8.4883e-04 2.3247e-04 3.1491e-04 3.2134e-03 -5.7180e-03 3.6562e-04 1.2128e-04 7.2581e-05 1.2973e-03 3.1677e-04 2.3287e-04 3.4660e-05 6.4716e-05 8.5456e-04 2.9865e-02 -2.6164e-03 2.0732e-04 6.8614e-05 4.3827e-05 4.4997e-04 7.8134e-04 8.5560e-06 2.2087e-06 8.1891e-07 4.4225e-05 1.3551e-02 0.0000e+00 -1.5679e-01 2.5056e-02 2.4749e-03 8.4408e-04 1.1143e-01 10 0 0 10 0 0 53.49 24.00 0.22 0.01355 0.01951 1000 188 1 5 0 50.090 26.51 19.99 24.00 37.13 37.6 987.46 862 422 276 328 168 155 2 -104 19 160 -63 19 -73 -241 102 -87 -36 97 -119 -26 -254 138 -85 -149 274 -352 -123 -112 -267 -42 -58 77 -168 -83 -75 -3 157 -35 41 100 -70 -85 106 -41 45 1 -38 179 -28 82 -43 18 67 -16 35 187 -66 101 46 -218 117 -117 -41 116 -38 152 6 61 5 -294 88 -79 84 138 -165 -55 -19 -53 3 -33 83 0 108 -107 22 -30 28 -89 -17 179 -68 5 13 -22 -9 133 -139 -64 -26 -135 45 -48 51 -33 24 0 -37 54 -8 -6 56 -44 -28 -7 155 -13 176 -49 -107 93 -53 37 29 19 -27 54 -14 -71 8 11 9 16 -3 -84 47 -80 29 -35 -5 62 -75 44 28 -89 74 101 54 36 42 23 24 0 -20 4 34 -14 4 -17 -57 24 -21 -9 26 -33 -7 -64 33 -21 -40 78 -109 -37 -33 -82 -15 -23 34 -81 -42 -39 -2 82 -18 21 51 -35 -42 54 -22 26 1 -24 114 -18 54 -28 11 44 -11 24 137 -50 73 33 -151 82 -85 -33 97 -32 126 4 44 4 -201 60 -60 67 120 -156 -54 -18 -54 3 -37 93 0 110 -109 21 -27 26 -90 -18 201 -83 6 15 -24 -9 137 -156 -77 -32 -163 56 -62 70 -47 33 1 -45 65 -10 -8 69 -57 -38 -10 203 -17 226 -60 -127 108 -65 46 38 25 -37 77 -21 -105 12 17 15 25 -4 -123 71 -116 44 -59 -9 110 -142 82 53 -168 137 SS 20210811T221418.6Z 7893.926604 22 1 50.23 2 61.22 264.07 44.69 214.77 0.00 1 0.00 1 0 66 2.025e-03 6.687e-04 1.142e-03 3.803e-04 -1.892596e-08 1.422317e-07 2.749502e-08 4.352825e-07 9.552139e-07 231.95 -2.00 3.54 -2.00 322.04 0.00e+00 7.662537e-04 5.238763e-05 2.189547e-05 5.499262e-05 2.441770e-04 288.24 -2.00 20.00 -2.00 321.93 0.00e+00 -1.713275e-05 7.005320e-05 4.929213e-06 2.889919e-05 4.310371e-04 288.24 -2.00 20.00 -2.00 321.82 0.00e+00 1.239577e-04 1.063363e-04 1.701421e-05 1.832464e-05 4.530152e-04 288.24 -2.00 20.00 -2.00 321.89 0.00e+00 2.569581e-01 5.972172e-04 3.748338e-05 1.574503e-03 2.525704e-03 243.59 0.58 0.00 1.01 4.41 318.58 0.00e+00 1.028376e-04 3.688473e-05 7.560880e-06 1.842995e-05 6.792467e-05 288.24 -2.00 20.00 -2.00 317.33 0.00e+00 2.067 0.000 303.00 329.40 4 1.3148e+00 1.7568e-03 1.9690e-02 2.4877e-03 7.9586e-03 -3.4510e-02 2.4244e-03 2.0499e-03 8.4382e-04 8.5518e-03 1.7575e-02 1.2390e-03 2.3771e-04 3.3122e-04 4.6636e-03 -8.4614e-03 5.6994e-04 1.7161e-04 8.6030e-05 1.9123e-03 1.5301e-03 3.5476e-04 2.7816e-05 7.1012e-05 1.2936e-03 1.6186e-02 -3.4188e-03 2.8308e-04 7.8076e-05 4.0759e-05 5.4496e-04 7.0544e-04 1.2153e-05 2.5135e-06 8.2527e-07 6.5143e-05 6.8949e-03 0.0000e+00 -1.1440e-01 3.3700e-02 2.1159e-03 7.2162e-04 1.5447e-01 10 0 0 10 0 0 99.97 23.63 0.24 0.00689 0.01228 686 129 1 5 0 73.200 26.21 19.99 23.63 37.61 36.8 987.14 1415 1037 181 493 569 -55 407 -207 170 60 171 -91 -360 -72 -5 -146 -148 63 18 -82 -251 -275 -2 -206 208 -273 -177 -121 -370 -193 -177 -145 -180 -66 -5 -59 262 -84 30 88 -107 -36 41 43 92 107 52 187 97 55 4 -70 112 23 148 104 -106 46 -32 -109 65 69 -34 50 -35 117 -55 -104 15 -181 20 -98 46 135 -105 23 -57 -17 2 -55 38 24 128 0 -55 -110 -65 -37 -56 92 -55 -27 52 -57 17 92 -72 -25 -24 -91 21 -41 13 17 -5 20 -21 17 50 27 67 -28 -94 -20 125 19 171 -37 -58 38 3 28 7 15 -15 2 -34 -41 -39 57 27 6 -22 -63 33 -65 16 -45 -2 43 -29 29 3 -88 88 130 104 19 51 63 -7 58 -33 29 10 31 -17 -70 -14 -1 -30 -32 14 4 -19 -53 -57 0 -47 51 -73 -47 -31 -99 -58 -62 -55 -76 -29 -2 -27 121 -39 14 40 -48 -16 19 21 48 59 29 108 58 33 2 -41 67 14 100 75 -79 33 -21 -70 42 50 -26 39 -28 91 -41 -77 10 -116 13 -70 37 111 -93 21 -55 -18 2 -58 40 25 134 0 -49 -94 -57 -36 -59 99 -64 -32 59 -60 18 98 -77 -29 -29 -113 26 -56 18 23 -7 27 -27 19 57 32 85 -39 -124 -26 170 25 215 -45 -68 43 4 37 10 20 -20 3 -50 -63 -62 92 44 11 -35 -97 50 -99 27 -73 -4 80 -55 57 7 -175 171 SS 20210811T225931.0Z 7893.957997 54 1 50.52 2 69.55 271.85 50.25 227.76 0.00 1 0.00 1 0 65 8.277e-02 1.304e-02 9.038e-02 1.055e-02 -7.040636e-06 3.973549e-06 1.971782e-07 4.357164e-07 3.654033e-05 231.95 -2.00 3.54 -2.00 323.17 0.00e+00 1.141547e-03 1.609807e-03 1.188610e-04 5.510455e-05 9.673018e-03 288.24 -2.00 20.00 -2.00 323.58 0.00e+00 1.717305e-03 2.087261e-03 6.884784e-05 2.888777e-05 1.773297e-02 288.24 -2.00 20.00 -2.00 322.68 0.00e+00 6.445671e-03 4.123770e-03 7.846846e-04 1.606510e-05 1.850816e-02 288.24 -2.00 20.00 -2.00 322.98 0.00e+00 3.368469e-01 2.031019e-02 2.135656e-03 1.573858e-03 1.039575e-01 226.75 13.95 0.00 0.75 179.13 320.58 0.00e+00 5.723327e-04 1.775184e-03 2.077514e-04 1.842943e-05 2.723005e-03 288.24 -2.00 20.00 -2.00 319.35 0.00e+00 2.833 0.000 303.00 329.40 4 5.3924e+00 4.2599e-02 2.7434e-02 2.4925e-03 3.2315e-01 -3.7812e-02 7.7819e-02 1.1155e-02 8.9995e-04 3.4824e-01 -2.7790e-02 4.0814e-02 3.8924e-03 3.6825e-04 1.8815e-01 7.2335e-02 2.2607e-02 1.1090e-03 1.2459e-04 6.5759e-02 -3.1157e-02 1.2668e-02 6.9487e-04 9.5399e-05 5.1409e-02 1.0933e-04 2.7957e-02 1.0476e-02 2.8673e-04 2.0833e-05 2.9806e-03 5.0661e-04 3.8255e-04 1.2157e-05 8.6076e-07 2.7135e-03 2.1988e-03 0.0000e+00 1.4897e+00 8.2020e-01 8.8085e-03 7.5997e-04 5.0519e+00 12 8 8 10 0 0 99.99 23.35 1.29 0.00220 0.00606 32 6 1 5 0 1578.360 26.00 19.99 23.35 36.71 36.5 987.40 14653 -29256 15588 -34249 9655 7807 -7361 35833 -3821 32333 -23858 7934 -6865 486 11009 8249 33188 -9799 118 -6854 -15941 5256 10944 -6300 -12620 2235 -5625 3793 18488 -4263 4224 -2617 12185 2183 748 4216 5332 7807 -19 -1303 565 -2629 3437 -3995 6557 564 -645 -2108 -1362 4314 -1013 4691 -4420 -11 -49 -523 -46 98 8178 -975 -2079 -3017 -1892 -1195 -1111 1658 1093 2125 -2695 -6574 -4831 -5288 4542 1381 1116 -2961 457 2379 -1049 1814 292 1757 -3184 -1297 -2099 -2155 -614 -1188 1039 849 -369 -88 1208 977 675 436 982 -735 605 1257 1574 -1088 1058 -83 -12 1114 -335 168 -522 -315 -1029 -562 -71 -133 1136 -351 1426 -1004 -1419 1245 -2212 -660 693 1423 21 -1860 -208 157 1413 -166 153 -977 -200 567 -926 589 -489 468 -308 544 -94 117 353 -557 196 295 -1378 384 -1822 311 322 -448 1434 -284 1585 -2466 584 -623 41 805 658 2091 -1084 12 -728 -1760 444 909 -713 -1684 280 -771 447 1958 -660 707 -558 2507 529 191 1059 1320 1895 -5 -345 147 -711 909 -1234 1945 188 -229 -777 -512 1551 -380 1641 -1721 -4 -21 -244 -22 46 3354 -429 -943 -1544 -1066 -702 -662 933 590 1049 -1281 -3127 -2308 -2855 2535 883 781 -2254 353 1924 -919 1597 262 1523 -2740 -1019 -1558 -1538 -452 -971 922 833 -398 -96 1256 952 615 394 948 -770 650 1407 1834 -1377 1397 -115 -17 1457 -417 197 -605 -376 -1294 -747 -97 -179 1475 -448 1710 -1194 -1639 1377 -2690 -859 949 2027 31 -2881 -334 265 2428 -294 275 -1747 -344 941 -1519 964 -853 871 -621 1158 -215 277 855 -1373 473