File name: Pandora283s1_LaPaz_20241111_L2Fit_ffus5c2d20240531p1-8.txt File generation date: 20241112T043716.0Z Data description: Level 2 spectral fitting results file Data file version: ffus5c2p1-8 Local principal investigator: Marcos Andrade Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 283 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora283_OF_v3d20231025.txt Instrument calibration file used: Pandora283s1_CF_v2d20240531.txt Level 1 file used: Pandora283s1_LaPaz_20241111_L1_smca1c2d20240531p1-8.txt Full location name: Laboratory for Atmospheric Physics, UMSA, La Paz Short location name: LaPaz Country of location: Bolivia Location latitude [deg]: -16.5389 Location longitude [deg]: -68.0661 Location altitude [m]: 3420 Local noon date: 20241111 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OOB session based on clearance session 1 First and last pixel inside fitting window: 328 594 Nominal wavelengths inside fitting window [nm]: 322.5216 322.6609 322.8002 322.9394 323.0786 323.2178 323.3570 323.4962 323.6354 323.7746 323.9138 324.0529 324.1920 324.3312 324.4703 324.6094 324.7485 324.8876 325.0266 325.1657 325.3047 325.4438 325.5828 325.7218 325.8608 325.9998 326.1387 326.2777 326.4166 326.5556 326.6945 326.8334 326.9723 327.1112 327.2501 327.3890 327.5278 327.6667 327.8055 327.9443 328.0831 328.2219 328.3607 328.4995 328.6382 328.7770 328.9157 329.0545 329.1932 329.3319 329.4706 329.6093 329.7479 329.8866 330.0252 330.1639 330.3025 330.4411 330.5797 330.7183 330.8568 330.9954 331.1340 331.2725 331.4110 331.5495 331.6880 331.8265 331.9650 332.1035 332.2419 332.3804 332.5188 332.6572 332.7956 332.9340 333.0724 333.2108 333.3491 333.4875 333.6258 333.7641 333.9025 334.0408 334.1791 334.3173 334.4556 334.5938 334.7321 334.8703 335.0085 335.1467 335.2849 335.4231 335.5613 335.6994 335.8376 335.9757 336.1138 336.2520 336.3901 336.5281 336.6662 336.8043 336.9423 337.0804 337.2184 337.3564 337.4944 337.6324 337.7704 337.9083 338.0463 338.1842 338.3222 338.4601 338.5980 338.7359 338.8738 339.0116 339.1495 339.2873 339.4252 339.5630 339.7008 339.8386 339.9764 340.1142 340.2519 340.3897 340.5274 340.6652 340.8029 340.9406 341.0783 341.2159 341.3536 341.4913 341.6289 341.7665 341.9041 342.0418 342.1793 342.3169 342.4545 342.5921 342.7296 342.8671 343.0047 343.1422 343.2797 343.4171 343.5546 343.6921 343.8295 343.9670 344.1044 344.2418 344.3792 344.5166 344.6540 344.7913 344.9287 345.0660 345.2033 345.3406 345.4780 345.6152 345.7525 345.8898 346.0270 346.1643 346.3015 346.4387 346.5759 346.7131 346.8503 346.9875 347.1246 347.2618 347.3989 347.5360 347.6731 347.8102 347.9473 348.0844 348.2214 348.3585 348.4955 348.6325 348.7695 348.9065 349.0435 349.1805 349.3175 349.4544 349.5913 349.7283 349.8652 350.0021 350.1390 350.2758 350.4127 350.5495 350.6864 350.8232 350.9600 351.0968 351.2336 351.3704 351.5071 351.6439 351.7806 351.9174 352.0541 352.1908 352.3275 352.4641 352.6008 352.7375 352.8741 353.0107 353.1473 353.2839 353.4205 353.5571 353.6937 353.8302 353.9668 354.1033 354.2398 354.3763 354.5128 354.6493 354.7857 354.9222 355.0586 355.1951 355.3315 355.4679 355.6043 355.7407 355.8770 356.0134 356.1497 356.2860 356.4224 356.5587 356.6950 356.8312 356.9675 357.1038 357.2400 357.3762 357.5124 357.6486 357.7848 357.9210 358.0572 358.1933 358.3295 358.4656 358.6017 358.7378 358.8739 359.0100 359.1461 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-436: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 437-703: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------