File name: Pandora283s1_LaPaz_20250106_L2Fit_fsus1c2d20240531p1-8.txt
File generation date: 20250107T044427.8Z
Data description: Level 2 spectral fitting results file
Data file version: fsus1c2p1-8
Local principal investigator: Marcos Andrade
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 283
Spectrometer number: 1
Processing software version used: BlickP v1.8.60
Instrument operation file used: Pandora283_OF_v3d20231025.txt
Instrument calibration file used: Pandora283s1_CF_v2d20240531.txt
Level 1 file used: Pandora283s1_LaPaz_20250106_L1_smca1c2d20240531p1-8.txt
Full location name: Laboratory for Atmospheric Physics, UMSA, La Paz
Short location name: LaPaz
Country of location: Bolivia
Location latitude [deg]: -16.5389
Location longitude [deg]: -68.0661
Location altitude [m]: 3420
Local noon date: 20250106
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method)
Data caveats: OOB session based on clearance session 1
First and last pixel inside fitting window: 210 355
Nominal wavelengths inside fitting window [nm]: 306.0078 306.1485 306.2891 306.4296 306.5702 306.7108 306.8513 306.9919 307.1324 307.2729 307.4134 307.5539 307.6944 307.8349 307.9754 308.1158 308.2563 308.3967 308.5371 308.6775 308.8179 308.9583 309.0987 309.2390 309.3794 309.5197 309.6600 309.8004 309.9407 310.0810 310.2213 310.3615 310.5018 310.6420 310.7823 310.9225 311.0627 311.2029 311.3431 311.4833 311.6235 311.7636 311.9038 312.0439 312.1840 312.3242 312.4643 312.6044 312.7444 312.8845 313.0246 313.1646 313.3046 313.4447 313.5847 313.7247 313.8647 314.0046 314.1446 314.2846 314.4245 314.5644 314.7044 314.8443 314.9842 315.1241 315.2639 315.4038 315.5437 315.6835 315.8233 315.9631 316.1029 316.2427 316.3825 316.5223 316.6621 316.8018 316.9416 317.0813 317.2210 317.3607 317.5004 317.6401 317.7797 317.9194 318.0590 318.1987 318.3383 318.4779 318.6175 318.7571 318.8967 319.0362 319.1758 319.3153 319.4549 319.5944 319.7339 319.8734 320.0129 320.1524 320.2918 320.4313 320.5707 320.7101 320.8495 320.9890 321.1283 321.2677 321.4071 321.5465 321.6858 321.8251 321.9645 322.1038 322.2431 322.3824 322.5216 322.6609 322.8002 322.9394 323.0786 323.2178 323.3570 323.4962 323.6354 323.7746 323.9138 324.0529 324.1920 324.3312 324.4703 324.6094 324.7485 324.8876 325.0266 325.1657 325.3047 325.4438 325.5828 325.7218 325.8608 325.9998 326.1387 326.2777
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Bromine oxide effective temperature [K]
Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Formaldehyde effective temperature [K]
Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Nitrous acid effective temperature [K]
Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 60: Nitrogen dioxide effective temperature [K]
Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 71: Ozone effective temperature [K]
Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 83: Sulfur dioxide effective temperature [K]
Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful
Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 91: Lower limit used for wavelength scaling [nm]
Column 92: Upper limit used for wavelength scaling [nm]
Column 93: Order of smoothing polynomial
Column 94: Smoothing polynomial coefficient, order 0
Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 99: Smoothing polynomial coefficient, order 1
Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 104: Smoothing polynomial coefficient, order 2
Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful
Column 109: Smoothing polynomial coefficient, order 3
Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful
Column 114: Smoothing polynomial coefficient, order 4
Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful
Column 119: Mean value of measured data inside fitting window [same units as measurements]
Column 120: Offset polynomial coefficient, order 0
Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful
Column 125: Wavelength change polynomial coefficient, order 0
Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 132: Resolution change polynomial coefficient, order 0
Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful
Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 144: Wavelength effective temperature [�C], 999=no effective temperature given
Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 148: Number of bright count cycles
Column 149: Number of dark count cycles
Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 153: Integration time [ms]
Column 154: Temperature at electronics board [�C], 999=no temperature signal
Column 155: Spectrometer control temperature [�C], 999=no temperature signal
Column 156: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Column 157: Temperature in head sensor [�C], 999=no temperature signal
Column 158: Humidity in head sensor [%], -9=no humidity signal
Column 159: Pressure in head sensor [hPa], -9=no pressure signal
Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------