File name: Pandora143s1_LibertyTX_20210810_L2Fit_fout2c12d20210527p1-8.txt File generation date: 20250128T111145.0Z Data description: Level 2 spectral fitting results file Data file version: fout2c12p1-8 Local principal investigator: Yuxuan Wang Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 143 Spectrometer number: 1 Processing software version used: BlickP v1.8.70 Instrument operation file used: Pandora143_OF_v3d20210326.txt Instrument calibration file used: Pandora143s1_CF_v12d20210527.txt Level 1 file used: Pandora143s1_LibertyTX_20210810_L1_smca1c12d20210527p1-8.txt Full location name: University of Houston Trailer Short location name: LibertyTX Country of location: United States Location latitude [deg]: 30.0965 Location longitude [deg]: -94.7635 Location altitude [m]: 3 Local noon date: 20210810 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 260 402 Nominal wavelengths inside fitting window [nm]: 305.0723 305.2131 305.3540 305.4948 305.6356 305.7764 305.9172 306.0580 306.1988 306.3395 306.4803 306.6210 306.7617 306.9024 307.0431 307.1838 307.3245 307.4651 307.6058 307.7464 307.8870 308.0276 308.1682 308.3088 308.4494 308.5899 308.7305 308.8710 309.0115 309.1520 309.2925 309.4330 309.5735 309.7139 309.8544 309.9948 310.1352 310.2756 310.4160 310.5564 310.6967 310.8371 310.9774 311.1178 311.2581 311.3984 311.5387 311.6789 311.8192 311.9595 312.0997 312.2399 312.3801 312.5203 312.6605 312.8007 312.9409 313.0810 313.2211 313.3613 313.5014 313.6415 313.7816 313.9216 314.0617 314.2017 314.3418 314.4818 314.6218 314.7618 314.9018 315.0418 315.1817 315.3217 315.4616 315.6015 315.7414 315.8813 316.0212 316.1611 316.3010 316.4408 316.5806 316.7205 316.8603 317.0001 317.1398 317.2796 317.4194 317.5591 317.6988 317.8386 317.9783 318.1180 318.2577 318.3973 318.5370 318.6766 318.8163 318.9559 319.0955 319.2351 319.3747 319.5142 319.6538 319.7933 319.9329 320.0724 320.2119 320.3514 320.4909 320.6303 320.7698 320.9092 321.0487 321.1881 321.3275 321.4669 321.6063 321.7456 321.8850 322.0243 322.1637 322.3030 322.4423 322.5816 322.7209 322.8602 322.9994 323.1387 323.2779 323.4171 323.5563 323.6955 323.8347 323.9739 324.1130 324.2522 324.3913 324.5304 324.6695 324.8086 324.9477 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Spectrometer control temperature [°C], 999=no temperature signal Column 95: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 96: Temperature in head sensor [°C], 999=no temperature signal Column 97: Temperature at electronics board 1 [°C], 999=no temperature signal Column 98: Temperature at electronics board 2 [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-243: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 244-386: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210810T160738.2Z 7892.671970 27 1 52.55 2 34.62 107.50 60.24 95.14 0.00 1 0.00 1 0 17 6.672e-03 5.137e-03 1.548e-04 9.784e-05 1.603347e-01 4.968009e-05 1.842500e-03 -6.000000e+00 3.778768e-03 229.72 -2.00 3.25 -2.00 315.32 0.00e+00 1.391067e-04 4.068553e-06 1.474503e-05 -6.000000e+00 1.501076e-04 294.59 -2.00 20.00 -2.00 315.03 0.00e+00 1.214 0.000 302.00 328.00 3 3.1633e-01 1.2886e-04 1.4421e-02 -6.0000e+00 9.5145e-03 -5.8353e-03 1.4273e-04 7.7575e-03 -6.0000e+00 1.0335e-02 3.5771e-03 8.1872e-05 3.8075e-03 -6.0000e+00 6.0621e-03 -2.0100e-03 3.7070e-05 1.0756e-03 -6.0000e+00 2.5822e-03 1.0001e-01 -3.5059e-04 2.6254e-06 1.2888e-05 -6.0000e+00 1.6941e-04 5.5717e-02 -3.4022e-04 10 0 0 10 0 0 24.50 18.45 0.34 0.05572 0.05308 4270 868 4 8 0 11.230 15.00 18.45 39.61 21.69 22.09 16.7 954.77 -963 -639 -1443 -1961 -1787 -842 361 865 687 -140 -613 -437 -257 303 118 14 72 313 696 800 439 868 791 664 500 387 382 102 467 1369 1367 1758 591 -788 -1294 -1410 -827 -586 -497 -719 -920 -913 -973 -706 -637 -725 -627 -846 -582 194 506 764 845 715 772 740 509 416 413 694 924 1042 1325 731 -10 -284 -471 371 497 359 293 24 410 164 72 67 -421 -125 -378 -670 -734 -1450 -1516 -1217 -846 -489 -372 62 153 151 185 127 415 587 444 396 619 489 4 -177 -314 -269 -4 -216 -571 -573 -629 -339 23 147 211 175 63 -79 16 134 44 142 -1 -241 -223 -12 204 492 484 399 852 698 445 359 107 210 2 33 -20 -119 69 -85 -233 -314 -451 -411 900000 -305 -208 -457 -546 -444 -208 97 262 225 -46 -192 -144 -94 124 49 6 31 139 316 374 204 397 375 332 261 204 193 47 218 632 610 830 299 -385 -582 -657 -435 -367 -342 -554 -745 -759 -763 -590 -530 -594 -492 -639 -424 142 394 625 722 587 641 626 435 350 341 577 808 984 1334 710 -10 -248 -412 321 447 364 295 25 414 170 68 60 -346 -99 -328 -610 -739 -1484 -1616 -1363 -1022 -589 -469 79 192 179 213 131 418 590 483 442 760 615 6 -217 -380 -301 -5 -260 -700 -733 -841 -468 31 210 311 251 90 -103 20 163 55 175 -1 -345 -324 -17 280 639 636 496 1003 848 579 462 143 281 2 47 -29 -178 105 -133 -363 -475 -662 -583 900000 SS 20210810T162408.7Z 7892.683434 29 1 28.31 2 31.26 111.42 56.81 97.44 0.00 1 0.00 1 0 17 6.633e-03 5.163e-03 1.931e-04 1.259e-04 1.548354e-01 6.396125e-05 1.782541e-03 -6.000000e+00 3.756342e-03 229.72 -2.00 3.25 -2.00 315.20 0.00e+00 1.487818e-04 5.096110e-06 1.354743e-05 -6.000000e+00 1.492294e-04 294.59 -2.00 20.00 -2.00 314.92 0.00e+00 1.169 0.000 302.00 328.00 3 2.7269e-01 1.6571e-04 1.3900e-02 -6.0000e+00 9.4580e-03 -6.4163e-03 1.8346e-04 7.4950e-03 -6.0000e+00 1.0274e-02 2.1731e-03 1.0511e-04 3.6787e-03 -6.0000e+00 6.0262e-03 -1.2998e-03 4.7354e-05 1.0390e-03 -6.0000e+00 2.5668e-03 1.1056e-01 -4.1131e-04 3.3717e-06 1.2610e-05 -6.0000e+00 1.6841e-04 5.5869e-02 -3.4735e-04 10 0 0 10 0 0 0.89 18.46 0.35 0.05587 0.05278 2508 510 4 8 0 10.410 14.98 18.46 41.70 21.58 22.09 16.2 962.85 -844 -571 -1276 -1965 -1713 -784 450 956 793 -72 -622 -449 -228 281 122 -73 129 307 719 776 408 950 801 647 437 350 380 73 458 1303 1374 1675 592 -765 -1369 -1356 -834 -558 -534 -777 -920 -956 -1002 -782 -679 -746 -645 -871 -642 199 499 771 836 699 789 709 512 390 421 684 940 1070 1285 756 -25 -276 -478 351 531 365 324 38 423 174 84 110 -427 -72 -376 -662 -712 -1460 -1500 -1236 -842 -496 -376 61 127 165 163 129 398 565 440 397 627 505 21 -159 -300 -247 12 -195 -587 -532 -614 -355 63 125 192 179 84 -69 10 136 28 142 -15 -254 -250 -44 171 467 490 404 823 711 429 373 114 199 1 4 -19 -120 79 -87 -191 -312 -448 -400 900000 -283 -197 -427 -579 -450 -204 128 305 273 -25 -205 -155 -88 120 53 -33 58 142 339 377 197 450 393 334 236 191 198 35 202 621 630 813 307 -383 -632 -647 -449 -358 -376 -612 -761 -755 -803 -620 -536 -624 -517 -671 -476 148 394 640 673 582 663 608 443 332 352 576 833 1022 1310 742 -25 -244 -422 306 481 373 329 40 430 182 80 93 -353 -57 -327 -605 -719 -1498 -1602 -1387 -1018 -599 -475 78 160 197 188 134 402 568 478 442 769 634 27 -196 -363 -276 13 -235 -719 -679 -820 -489 85 179 282 257 120 -89 12 164 35 175 -20 -362 -362 -63 235 603 642 500 965 859 555 477 150 265 1 6 -28 -177 120 -135 -295 -468 -653 -564 900000 SS 20210810T162437.1Z 7892.683763 29 2 28.08 2 31.16 111.54 56.71 97.51 0.00 1 0.00 1 0 17 6.634e-03 5.160e-03 1.932e-04 1.260e-04 1.547865e-01 6.401761e-05 1.782281e-03 -6.000000e+00 3.756692e-03 229.72 -2.00 3.25 -2.00 315.20 0.00e+00 1.524461e-04 5.102038e-06 1.355028e-05 -6.000000e+00 1.492410e-04 294.59 -2.00 20.00 -2.00 314.92 0.00e+00 1.168 0.000 302.00 328.00 3 2.7525e-01 1.6587e-04 1.3889e-02 -6.0000e+00 9.4589e-03 -6.5284e-03 1.8362e-04 7.4934e-03 -6.0000e+00 1.0275e-02 2.1976e-03 1.0517e-04 3.6783e-03 -6.0000e+00 6.0268e-03 -1.2747e-03 4.7392e-05 1.0389e-03 -6.0000e+00 2.5671e-03 1.1042e-01 -3.9969e-04 3.3716e-06 1.2562e-05 -6.0000e+00 1.6843e-04 5.5822e-02 -3.4642e-04 10 0 0 10 0 0 8.75 18.45 0.35 0.05582 0.05282 2508 510 4 8 0 10.410 14.99 18.45 41.70 21.58 22.09 16.2 962.93 -847 -577 -1319 -1861 -1777 -730 464 927 811 -113 -550 -400 -189 243 85 -19 117 335 713 799 404 925 812 625 462 345 361 38 406 1346 1355 1746 554 -797 -1376 -1401 -816 -581 -497 -791 -936 -971 -1006 -759 -682 -715 -673 -875 -633 185 519 752 842 672 793 726 520 394 415 674 937 1068 1303 752 -24 -285 -476 358 511 355 318 24 407 188 85 114 -427 -81 -355 -651 -739 -1467 -1504 -1209 -804 -492 -375 66 149 169 171 139 399 575 431 409 611 497 19 -151 -302 -260 14 -220 -585 -554 -629 -348 38 148 211 182 68 -77 9 148 18 123 -8 -259 -229 -37 162 472 461 392 844 698 419 389 110 205 15 19 -22 -118 79 -78 -214 -298 -454 -400 900000 -284 -199 -441 -548 -467 -190 132 296 279 -39 -181 -138 -72 104 37 -9 53 155 336 388 195 439 398 323 249 189 188 18 179 641 622 847 288 -399 -635 -669 -439 -372 -350 -623 -774 -766 -805 -601 -538 -598 -539 -673 -470 138 410 624 677 560 667 622 449 335 347 568 830 1020 1327 738 -24 -252 -420 312 462 362 322 25 414 196 81 103 -353 -65 -310 -595 -746 -1504 -1606 -1356 -972 -594 -473 84 188 200 197 144 402 577 467 455 750 623 24 -185 -365 -291 15 -265 -716 -708 -840 -480 51 211 309 260 97 -100 11 178 22 151 -10 -370 -330 -52 222 610 604 484 989 843 541 498 146 271 20 27 -31 -174 119 -120 -330 -447 -662 -563 900000 SS 20210810T164228.5Z 7892.696163 34 1 52.75 2 27.64 116.58 53.01 100.16 0.00 1 0.00 1 0 17 6.535e-03 5.134e-03 1.421e-04 9.515e-05 1.501607e-01 4.843126e-05 1.727833e-03 -6.000000e+00 3.701379e-03 229.72 -2.00 3.25 -2.00 315.07 0.00e+00 1.587528e-04 3.763021e-06 1.242328e-05 -6.000000e+00 1.470034e-04 294.59 -2.00 20.00 -2.00 314.80 0.00e+00 1.128 0.000 302.00 328.00 3 3.7766e-01 1.2535e-04 1.3431e-02 -6.0000e+00 9.3198e-03 -3.8100e-03 1.3869e-04 7.2608e-03 -6.0000e+00 1.0123e-02 2.5739e-03 7.9352e-05 3.5643e-03 -6.0000e+00 5.9377e-03 -2.0891e-03 3.5584e-05 1.0069e-03 -6.0000e+00 2.5296e-03 1.0455e-01 -2.4012e-04 2.5422e-06 1.2239e-05 -6.0000e+00 1.6591e-04 5.5137e-02 -3.1793e-04 10 0 0 10 0 0 65.93 18.46 0.34 0.05514 0.05333 4241 862 4 8 0 11.310 14.98 18.46 42.27 21.69 22.09 16.1 965.85 -876 -488 -1256 -1788 -1705 -681 515 924 832 -91 -501 -409 -265 268 108 -37 67 294 670 816 445 894 818 633 464 344 369 75 421 1351 1358 1691 596 -771 -1284 -1421 -813 -651 -566 -773 -959 -963 -1014 -724 -688 -741 -628 -847 -625 162 487 744 834 677 753 718 461 390 366 643 898 1020 1294 737 -9 -307 -479 334 497 365 322 16 429 196 78 66 -391 -121 -384 -632 -701 -1434 -1521 -1209 -817 -476 -362 69 151 163 186 117 405 582 429 428 628 522 33 -172 -297 -253 7 -194 -578 -552 -617 -355 28 134 213 169 61 -96 12 124 42 120 -13 -240 -226 -16 165 470 458 386 811 680 431 361 107 202 -8 25 -12 -105 76 -71 -202 -306 -443 -407 900000 -309 -177 -441 -552 -469 -186 153 308 300 -33 -172 -147 -106 119 49 -17 31 140 327 409 223 438 414 338 258 194 198 37 191 606 640 842 317 -396 -607 -694 -448 -427 -407 -622 -753 -776 -829 -585 -554 -587 -513 -664 -472 122 391 627 680 571 642 624 404 336 310 549 806 986 1333 731 -9 -274 -396 294 453 375 329 16 439 206 75 56 -326 -97 -336 -579 -710 -1475 -1629 -1360 -991 -576 -458 89 192 194 215 121 409 585 466 476 769 654 43 -210 -358 -282 8 -233 -706 -703 -822 -488 38 190 311 241 86 -124 15 149 51 146 -17 -340 -325 -23 224 604 597 475 945 816 553 458 141 265 -11 35 -17 -154 113 -108 -310 -457 -641 -568 900000 SS 20210810T165829.9Z 7892.707290 36 1 35.58 2 24.62 122.06 49.72 102.72 0.00 1 0.00 1 0 17 6.452e-03 5.172e-03 2.054e-03 1.418e-03 1.491881e-01 7.229721e-04 1.708338e-03 -6.000000e+00 3.655315e-03 229.72 -2.00 3.25 -2.00 314.90 0.00e+00 1.390849e-04 5.468702e-05 1.200574e-05 -6.000000e+00 1.451314e-04 294.59 -2.00 20.00 -2.00 314.63 0.00e+00 1.100 0.000 302.00 328.00 3 5.5230e+00 1.8684e-03 1.3158e-02 -6.0000e+00 9.2040e-03 1.1518e-02 2.0665e-03 7.1863e-03 -6.0000e+00 9.9962e-03 2.7286e-03 1.1816e-03 3.5284e-03 -6.0000e+00 5.8632e-03 -1.6599e-03 5.2729e-04 9.9670e-04 -6.0000e+00 2.4986e-03 6.2421e-04 9.7457e-05 3.7962e-05 1.2221e-05 -6.0000e+00 1.6378e-04 5.4223e-02 -2.7270e-04 10 0 0 10 0 0 99.76 18.46 0.29 0.05422 0.05496 25 18 2 8 0 1418.560 15.00 18.46 42.63 21.58 22.09 15.9 966.15 -210 -695 -746 -1811 -1345 -463 351 952 353 18 -377 -1251 -442 493 -172 -61 -41 470 845 898 -6 602 380 524 933 123 491 279 770 1309 1509 1758 486 -973 -1387 -1786 -549 -576 -528 -783 -732 -1038 -754 -668 -700 -618 -400 -607 -920 139 339 882 540 501 504 681 727 330 335 566 840 892 1267 898 145 -214 -616 -77 516 364 112 327 477 134 159 -40 -586 -510 -308 -572 -705 -1400 -1523 -1153 -657 -199 -322 299 424 226 -125 -38 330 447 -94 295 717 510 110 128 -366 -336 -156 -171 -739 -527 -700 -151 107 414 418 170 195 -286 -344 -45 -287 81 -2 -228 -163 195 210 539 289 295 595 556 227 213 119 312 -16 22 94 244 205 -100 -37 -396 -581 -518 900000 -75 -256 -267 -585 -395 -135 111 329 131 7 -134 -466 -179 218 -82 -30 -20 236 429 470 -3 311 202 287 527 71 270 143 373 628 753 920 269 -523 -700 -927 -310 -373 -387 -622 -605 -872 -640 -566 -590 -515 -323 -475 -702 106 270 729 461 440 444 609 650 293 294 500 766 856 1272 922 142 -194 -533 -67 476 365 117 347 502 136 152 -35 -487 -413 -265 -534 -702 -1482 -1650 -1296 -773 -243 -406 381 535 276 -143 -41 331 448 -99 331 854 642 141 158 -432 -377 -174 -202 -922 -673 -920 -202 148 589 602 242 267 -369 -421 -53 -345 101 -3 -312 -225 265 281 696 362 356 696 661 283 273 155 408 -22 30 134 354 304 -150 -55 -584 -843 -734 900000 SS 20210810T171552.5Z 7892.719357 40 1 51.12 2 21.56 129.40 46.19 105.73 0.00 1 0.00 1 0 17 6.519e-03 5.003e-03 1.430e-03 8.509e-04 1.442204e-01 4.316113e-04 1.652306e-03 -6.000000e+00 3.693201e-03 229.72 -2.00 3.25 -2.00 315.59 0.00e+00 1.411603e-04 3.717059e-05 1.454862e-05 -6.000000e+00 1.466476e-04 294.59 -2.00 20.00 -2.00 315.29 0.00e+00 1.075 0.000 302.00 328.00 3 4.2522e+00 1.1229e-03 1.2827e-02 -6.0000e+00 9.2993e-03 6.6594e-03 1.2432e-03 6.9631e-03 -6.0000e+00 1.0100e-02 3.6524e-03 7.1543e-04 3.4232e-03 -6.0000e+00 5.9241e-03 -3.4379e-03 3.2525e-04 9.7497e-04 -6.0000e+00 2.5244e-03 2.3088e-03 1.1253e-04 2.3142e-05 1.1620e-05 -6.0000e+00 1.6549e-04 5.4704e-02 -2.7696e-04 10 0 0 10 0 0 99.99 18.45 0.23 0.05470 0.05555 316 64 1 8 0 157.260 15.01 18.45 40.30 21.69 22.09 15.9 951.86 -868 -643 -1493 -1646 -1557 -408 929 817 894 -135 -178 -487 -139 366 71 118 140 -133 366 642 507 836 765 641 636 298 498 116 605 1468 1399 1771 404 -546 -1083 -1334 -743 -559 -702 -867 -908 -865 -1088 -757 -651 -705 -699 -722 -530 5 622 638 842 690 724 816 504 296 387 732 812 957 1216 840 -55 -322 -430 278 635 359 433 36 548 208 82 29 -477 -264 -316 -702 -750 -1520 -1611 -1194 -844 -518 -334 114 302 256 233 76 312 515 374 407 678 567 24 -172 -398 -304 -54 -188 -472 -586 -761 -268 129 209 267 181 104 -87 -65 -55 -54 130 60 -225 -171 -85 160 499 343 251 700 701 355 322 58 124 35 4 98 -222 134 78 -234 -207 -408 -319 900000 -251 -191 -430 -415 -381 -99 244 223 262 -40 -54 -142 -45 132 28 48 57 -56 157 283 222 359 339 299 309 147 233 50 239 572 572 763 186 -242 -481 -562 -353 -316 -472 -652 -715 -698 -892 -613 -525 -558 -530 -524 -370 3 460 497 682 578 613 702 438 253 325 619 722 917 1144 812 -54 -283 -350 224 569 363 429 37 544 215 78 24 -362 -193 -251 -629 -742 -1510 -1666 -1295 -987 -645 -434 150 392 313 259 83 307 502 394 434 794 724 31 -215 -460 -352 -62 -216 -588 -762 -1034 -375 188 320 420 278 149 -113 -78 -67 -63 160 81 -323 -248 -122 221 648 424 318 838 863 432 412 77 165 48 6 147 -348 215 128 -383 -329 -630 -475 900000