File name: Pandora143s1_LibertyTX_20210818_L2Fit_ffus5c12d20210527p1-8.txt File generation date: 20250128T111430.3Z Data description: Level 2 spectral fitting results file Data file version: ffus5c12p1-8 Local principal investigator: Yuxuan Wang Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 143 Spectrometer number: 1 Processing software version used: BlickP v1.8.70 Instrument operation file used: Pandora143_OF_v3d20210326.txt Instrument calibration file used: Pandora143s1_CF_v12d20210527.txt Level 1 file used: Pandora143s1_LibertyTX_20210818_L1_smca1c12d20210527p1-8.txt Full location name: University of Houston Trailer Short location name: LibertyTX Country of location: United States Location latitude [deg]: 30.0965 Location longitude [deg]: -94.7635 Location altitude [m]: 3 Local noon date: 20210818 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 385 651 Nominal wavelengths inside fitting window [nm]: 322.5816 322.7209 322.8602 322.9994 323.1387 323.2779 323.4171 323.5563 323.6955 323.8347 323.9739 324.1130 324.2522 324.3913 324.5304 324.6695 324.8086 324.9477 325.0868 325.2258 325.3649 325.5039 325.6429 325.7819 325.9209 326.0599 326.1989 326.3378 326.4768 326.6157 326.7547 326.8936 327.0325 327.1713 327.3102 327.4491 327.5879 327.7268 327.8656 328.0044 328.1432 328.2820 328.4207 328.5595 328.6983 328.8370 328.9757 329.1144 329.2531 329.3918 329.5305 329.6692 329.8078 329.9464 330.0851 330.2237 330.3623 330.5009 330.6395 330.7780 330.9166 331.0551 331.1936 331.3322 331.4707 331.6092 331.7476 331.8861 332.0246 332.1630 332.3014 332.4398 332.5782 332.7166 332.8550 332.9934 333.1317 333.2701 333.4084 333.5467 333.6850 333.8233 333.9616 334.0999 334.2382 334.3764 334.5146 334.6529 334.7911 334.9293 335.0675 335.2056 335.3438 335.4819 335.6201 335.7582 335.8963 336.0344 336.1725 336.3106 336.4486 336.5867 336.7247 336.8628 337.0008 337.1388 337.2768 337.4147 337.5527 337.6907 337.8286 337.9665 338.1045 338.2424 338.3803 338.5181 338.6560 338.7939 338.9317 339.0695 339.2074 339.3452 339.4830 339.6208 339.7585 339.8963 340.0340 340.1718 340.3095 340.4472 340.5849 340.7226 340.8603 340.9979 341.1356 341.2732 341.4108 341.5485 341.6861 341.8236 341.9612 342.0988 342.2363 342.3739 342.5114 342.6489 342.7864 342.9239 343.0614 343.1989 343.3363 343.4738 343.6112 343.7486 343.8860 344.0234 344.1608 344.2982 344.4355 344.5729 344.7102 344.8476 344.9849 345.1222 345.2594 345.3967 345.5340 345.6712 345.8085 345.9457 346.0829 346.2201 346.3573 346.4945 346.6316 346.7688 346.9059 347.0430 347.1802 347.3173 347.4544 347.5914 347.7285 347.8656 348.0026 348.1396 348.2766 348.4136 348.5506 348.6876 348.8246 348.9615 349.0985 349.2354 349.3723 349.5092 349.6461 349.7830 349.9199 350.0568 350.1936 350.3304 350.4672 350.6041 350.7409 350.8776 351.0144 351.1512 351.2879 351.4246 351.5614 351.6981 351.8348 351.9715 352.1081 352.2448 352.3814 352.5181 352.6547 352.7913 352.9279 353.0645 353.2011 353.3376 353.4742 353.6107 353.7472 353.8838 354.0203 354.1567 354.2932 354.4297 354.5661 354.7026 354.8390 354.9754 355.1118 355.2482 355.3846 355.5209 355.6573 355.7936 355.9299 356.0662 356.2025 356.3388 356.4751 356.6114 356.7476 356.8839 357.0201 357.1563 357.2925 357.4287 357.5649 357.7010 357.8372 357.9733 358.1094 358.2455 358.3816 358.5177 358.6538 358.7899 358.9259 359.0619 359.1980 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Spectrometer control temperature [°C], 999=no temperature signal Column 165: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 166: Temperature in head sensor [°C], 999=no temperature signal Column 167: Temperature at electronics board 1 [°C], 999=no temperature signal Column 168: Temperature at electronics board 2 [°C], 999=no temperature signal Column 169: Humidity in head sensor [%], -9=no humidity signal Column 170: Pressure in head sensor [hPa], -9=no pressure signal Columns 171-437: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 438-704: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210818T133452.5Z 7900.565885 90 1 33.98 2 68.13 87.40 163.01 280.36 0.00 1 0.00 1 0 33 1.938e-03 1.613e-03 1.323e-03 1.200e-03 6.527661e-07 4.037445e-07 4.907791e-08 3.645635e-07 6.233939e-07 229.53 -2.00 3.25 -2.00 341.00 0.00e+00 2.432468e-04 1.132061e-04 1.428553e-05 1.538572e-05 1.743341e-04 294.57 -2.00 20.00 -2.00 338.48 0.00e+00 7.643445e-06 1.586481e-05 1.019433e-06 2.389313e-05 2.864208e-05 294.57 -2.00 20.00 -2.00 346.98 0.00e+00 1.708061e-04 4.809284e-05 1.330823e-05 6.974579e-06 8.493635e-05 294.57 -2.00 20.00 -2.00 345.65 0.00e+00 1.293512e+05 1.040164e+05 2.960705e+04 1.922883e+05 1.641754e+05 274.85 -2.00 10.55 -2.00 352.25 0.00e+00 3.392758e-01 1.646099e-03 2.541109e-03 1.885404e-03 2.113287e-03 229.53 -2.00 3.25 -2.00 331.04 0.00e+00 -1.269611e-03 1.848596e-03 2.022100e-04 6.970094e-05 1.959425e-03 294.57 -2.00 20.00 -2.00 329.29 0.00e+00 2.660 0.000 319.50 362.20 4 4.9315e+00 1.6017e-03 1.8805e-02 1.3644e-03 2.7129e-03 -2.9173e-03 4.2594e-04 2.9424e-03 2.5556e-04 6.5554e-04 -8.7754e-03 8.0611e-04 5.4136e-04 1.0371e-04 1.2603e-03 2.4852e-04 3.8996e-04 4.2629e-04 6.5952e-05 4.9309e-04 2.9538e-03 6.4081e-04 2.6812e-04 6.8325e-05 9.2840e-04 7.8685e-04 -3.9177e-03 8.7573e-04 1.8665e-04 6.0969e-05 1.3334e-03 2.6923e-04 1.5434e-05 2.6160e-06 5.6945e-07 2.6129e-05 5.7307e-02 -2.2338e-04 -1.0300e-01 9.3254e-02 1.6831e-02 3.7986e-03 1.4662e-01 12 8 8 10 0 0 98.57 18.16 0.27 0.05731 0.06063 11 8 2 8 0 3088.640 15.00 18.16 35.71 21.17 21.88 16.6 929.36 -535 282 -330 -599 86 -329 518 -244 5 256 1472 98 -250 -21 -183 -349 43 -511 183 -6 -42 105 -105 294 33 -145 41 207 352 -45 -126 -1 -182 -22 -147 -334 60 502 -127 -54 121 148 145 -71 -167 -174 97 -310 -47 -78 -9 -50 -214 66 -286 -114 267 -16 -84 -38 -120 129 161 130 -78 374 314 -4 109 -109 -253 -115 -261 -64 113 106 133 -108 11 -61 -27 49 54 155 41 143 -78 100 64 -248 43 -113 -125 4 -47 57 115 -107 -71 203 254 237 128 75 -109 47 -100 4 -85 -46 243 21 191 222 124 250 -155 110 86 -227 -273 404 -223 75 -220 -155 -96 -194 103 -198 -199 -9 -5 36 -282 163 -83 57 12 -131 -205 -109 32 -42 -271 39 66 133 -20 87 91 134 19 33 109 -112 249 -180 -186 105 82 18 303 14 151 -9 210 -300 -104 233 -71 -82 18 -151 122 83 198 106 -84 -1 135 -101 -108 18 45 -4 26 82 36 25 -201 -78 16 -306 -5 -24 -171 50 -3 -97 -39 -109 68 51 57 -186 -128 -211 101 108 40 146 110 57 -23 4 111 -120 -116 -115 161 -33 279 -108 149 -52 79 30 184 -142 32 -83 -194 115 17 189 36 32 -6 -24 -287 -129 25 -86 -20 49 -142 -113 3 -10 91 173 -24 219 48 -61 85 240 -266 135 73 -476 174 -35 -162 117 900000 -237 121 -147 -287 43 -172 274 -132 3 151 881 60 -156 -13 -111 -205 25 -293 108 -4 -28 73 -77 223 26 -113 32 160 276 -36 -101 -1 -142 -17 -115 -261 46 374 -93 -39 91 112 109 -53 -130 -143 83 -280 -43 -72 -8 -47 -203 62 -264 -102 223 -13 -69 -32 -103 111 137 111 -67 332 286 -3 98 -96 -226 -104 -241 -59 103 97 121 -97 9 -52 -23 42 48 142 39 138 -76 95 60 -233 42 -114 -129 4 -46 51 94 -84 -60 185 240 220 113 63 -88 39 -90 4 -84 -46 231 20 178 216 125 255 -161 114 87 -223 -265 393 -226 80 -244 -174 -107 -214 111 -208 -206 -10 -5 38 -288 163 -82 58 13 -145 -229 -120 35 -45 -290 43 75 151 -22 97 100 146 20 33 102 -98 210 -158 -173 104 87 20 337 16 170 -10 235 -328 -109 236 -73 -88 20 -170 138 96 231 122 -93 -1 136 -103 -115 20 51 -5 29 92 41 28 -222 -83 16 -325 -5 -26 -189 57 -4 -122 -50 -138 86 62 69 -224 -150 -237 112 124 47 180 137 69 -27 5 115 -125 -128 -134 194 -40 342 -133 186 -66 100 39 234 -182 41 -107 -252 149 21 243 45 39 -8 -29 -351 -158 31 -108 -25 58 -160 -120 4 -10 94 183 -26 253 55 -68 88 231 -247 121 66 -437 163 -35 -180 136 900000 SS 20210818T135203.7Z 7900.577820 92 1 35.15 2 64.41 89.51 166.43 285.24 0.00 1 0.00 1 0 33 1.144e-03 1.074e-03 7.874e-04 7.296e-04 8.232937e-07 2.434007e-07 4.041324e-08 3.645984e-07 3.681047e-07 229.53 -2.00 3.25 -2.00 340.65 0.00e+00 2.313388e-04 6.789508e-05 1.277659e-05 1.532211e-05 1.027461e-04 294.57 -2.00 20.00 -2.00 338.10 0.00e+00 2.083709e-05 9.726126e-06 8.059400e-07 2.389257e-05 1.693543e-05 294.57 -2.00 20.00 -2.00 346.71 0.00e+00 1.367501e-04 2.934715e-05 1.203020e-05 7.009851e-06 5.008087e-05 294.57 -2.00 20.00 -2.00 345.34 0.00e+00 3.024068e+05 6.236414e+04 2.670704e+04 1.922179e+05 9.638059e+04 274.85 -2.00 10.55 -2.00 352.16 0.00e+00 2.929634e-01 9.533555e-04 2.222470e-03 1.885656e-03 1.223056e-03 229.53 -2.00 3.25 -2.00 330.76 0.00e+00 -8.282345e-04 1.068425e-03 1.870148e-04 6.997985e-05 1.159650e-03 294.57 -2.00 20.00 -2.00 328.93 0.00e+00 2.301 0.000 319.50 362.20 4 4.2966e+00 9.7749e-04 1.6264e-02 1.3641e-03 1.6089e-03 -2.3169e-02 2.5450e-04 2.5446e-03 2.5547e-04 3.8579e-04 -3.7920e-03 4.8200e-04 4.6936e-04 1.0197e-04 7.3971e-04 -2.0763e-04 2.2882e-04 3.7276e-04 6.6582e-05 2.9059e-04 9.1047e-04 3.7937e-04 2.3618e-04 6.7255e-05 5.4390e-04 1.9080e-03 -2.8038e-04 5.3950e-04 1.7675e-04 6.3366e-05 8.0664e-04 1.4956e-04 9.4015e-06 2.3712e-06 5.8355e-07 1.5408e-05 5.8727e-02 -2.9674e-04 -2.5826e-01 5.7582e-02 1.5002e-02 3.9253e-03 8.9064e-02 12 8 8 10 0 0 7.16 18.16 0.22 0.05873 0.06057 23 16 2 8 0 1527.860 14.97 18.16 37.64 21.17 21.88 16.7 941.14 -236 -118 -10 -130 175 30 -4 55 -104 238 30 69 -238 -23 -107 -198 -95 -253 63 125 15 298 143 315 12 -191 194 38 70 -90 -128 6 25 132 31 -164 123 -37 -25 59 145 14 108 -19 -32 101 104 -36 29 -121 -92 -2 -214 -41 -128 -245 6 -182 46 -25 -86 -85 30 2 84 125 198 -265 57 165 -213 62 34 25 -7 16 18 -180 59 -62 -143 71 -10 66 -111 68 -179 262 -25 -2 -48 -117 51 18 -42 -17 55 123 41 370 97 246 28 -15 117 83 30 -36 56 -180 54 -70 61 110 -5 185 4 -28 44 -319 -87 -1 -122 67 33 -16 -88 -54 27 -28 -173 -26 -23 -63 103 -56 62 -33 -32 -22 -54 -79 64 -62 33 -10 180 -6 60 -55 -20 137 51 171 53 -143 50 -59 -83 46 89 -152 59 -20 -47 162 -73 102 -103 53 -152 11 79 13 92 10 -25 126 -190 -36 -224 -31 -35 47 75 -4 22 -20 -8 8 34 128 173 -40 -99 41 -149 -54 62 -63 70 -64 -116 -55 31 -185 -31 77 -31 39 20 -106 117 -42 107 -115 61 34 -158 -20 34 41 6 -73 44 44 129 26 19 56 33 -86 28 -47 -44 -47 6 273 48 9 -117 15 109 -16 13 49 -136 28 -10 -185 10 18 -38 -117 101 -50 304 183 -306 256 -222 -137 185 -138 -64 10 900000 -114 -57 -5 -69 94 17 -2 32 -62 151 20 44 -157 -15 -70 -125 -58 -154 41 83 10 221 110 254 10 -155 154 30 57 -75 -107 5 20 104 25 -131 100 -29 -19 45 114 11 84 -15 -26 86 92 -33 27 -116 -86 -2 -207 -39 -122 -220 5 -155 39 -21 -76 -75 26 2 74 112 183 -248 51 150 -190 56 32 23 -6 15 17 -164 53 -53 -122 63 -9 62 -105 67 -178 249 -24 -2 -47 -117 53 18 -42 -15 45 101 36 340 92 234 26 -13 97 72 27 -34 56 -177 51 -67 58 108 -5 192 4 -29 45 -313 -85 -1 -125 71 37 -18 -98 -60 29 -30 -179 -27 -24 -66 104 -56 61 -33 -34 -24 -60 -86 69 -65 35 -10 204 -6 69 -61 -22 147 56 175 50 -126 43 -52 -78 45 93 -166 66 -22 -53 179 -80 110 -107 54 -157 12 86 15 105 11 -29 143 -208 -38 -223 -31 -37 52 83 -4 24 -22 -9 9 37 136 177 -43 -106 43 -164 -62 73 -78 87 -78 -144 -67 37 -220 -35 84 -34 45 24 -128 141 -49 121 -123 63 36 -170 -23 40 48 7 -87 54 55 160 32 24 70 41 -109 35 -59 -56 -59 8 326 58 11 -139 19 134 -20 16 58 -150 30 -10 -186 10 19 -43 -132 114 -55 311 175 -283 231 -198 -125 171 -138 -70 12 900000 SS 20210818T141113.7Z 7900.591130 97 1 34.74 2 60.27 91.95 170.12 293.81 0.00 1 0.00 1 0 33 1.025e-03 9.350e-04 6.647e-04 6.278e-04 1.038010e-06 2.067638e-07 3.601413e-08 3.646549e-07 3.297201e-07 229.53 -2.00 3.25 -2.00 340.20 0.00e+00 1.246154e-04 5.737104e-05 1.123242e-05 1.524032e-05 9.152333e-05 294.57 -2.00 20.00 -2.00 337.59 0.00e+00 -5.323935e-06 8.459667e-06 6.710405e-07 2.389180e-05 1.524594e-05 294.57 -2.00 20.00 -2.00 346.33 0.00e+00 1.247255e-04 2.537968e-05 1.143568e-05 7.078328e-06 4.480471e-05 294.57 -2.00 20.00 -2.00 344.92 0.00e+00 1.639829e+05 5.296406e+04 2.533225e+04 1.921345e+05 8.552602e+04 274.85 -2.00 10.55 -2.00 352.02 0.00e+00 2.581879e-01 7.786265e-04 1.956231e-03 1.885529e-03 1.076407e-03 229.53 -2.00 3.25 -2.00 330.46 0.00e+00 1.418889e-04 8.705096e-04 1.679077e-04 6.940937e-05 1.038284e-03 294.57 -2.00 20.00 -2.00 328.60 0.00e+00 2.007 0.000 319.50 362.20 4 4.2083e+00 8.4359e-04 1.4192e-02 1.3640e-03 1.4479e-03 -1.3520e-02 2.1250e-04 2.2213e-03 2.5544e-04 3.4108e-04 -2.5871e-03 4.0801e-04 4.0354e-04 9.8354e-05 6.5710e-04 7.4176e-05 1.8887e-04 3.3145e-04 6.7138e-05 2.5849e-04 7.1055e-04 3.1705e-04 2.1881e-04 6.6309e-05 4.7985e-04 2.5519e-03 -4.7060e-04 4.7405e-04 1.6026e-04 6.4590e-05 7.5184e-04 1.4214e-04 8.1415e-06 2.2108e-06 6.1260e-07 1.3802e-05 5.8518e-02 -2.8554e-04 -2.5854e-01 5.0396e-02 1.3402e-02 4.0293e-03 8.1930e-02 12 9 8 11 8 0 0.42 18.18 0.20 0.05852 0.06027 29 21 2 8 0 1197.640 14.98 18.18 38.81 21.17 21.88 16.5 946.72 -454 47 44 139 299 -139 157 -20 -120 255 265 106 -102 -241 -37 -273 -41 -154 -6 119 8 113 25 78 173 -103 32 -63 -59 -45 -127 6 -26 -46 -26 16 41 -65 83 59 94 -154 85 133 68 14 52 -159 -70 -13 53 159 -185 79 -165 -192 26 -32 -16 85 58 64 -36 -6 80 37 29 -64 -104 2 -114 186 12 13 -22 110 44 -50 110 3 -134 -39 -29 -3 7 64 -207 233 -21 -134 111 -142 41 -37 -102 -34 2 90 -11 77 72 49 -11 61 37 74 18 151 -80 -166 163 -92 80 223 -79 94 15 -82 41 -124 88 -45 -55 49 -13 22 -29 31 -62 6 -173 6 3 -97 10 -118 -125 80 33 9 69 4 -12 -30 -57 -59 150 -50 144 -61 -14 211 -118 168 32 -53 29 -76 -125 60 119 -21 88 -91 56 87 -38 -6 -73 90 -32 -39 26 -191 19 82 -36 97 -15 42 -123 -34 -9 -9 -4 -81 -36 -50 1 95 -25 50 4 -52 -88 28 -84 -32 23 -72 123 -2 -30 1 28 -74 -26 -17 -144 84 103 -104 72 80 98 -36 -14 -62 4 15 -42 128 48 -56 -68 36 -48 57 -40 -20 98 -53 5 -23 51 -9 -13 38 -15 83 66 -134 -26 -100 3 153 -29 38 -105 -14 101 45 -82 -61 209 -14 123 196 -223 191 -172 -219 188 -189 -136 85 900000 -241 25 23 80 173 -84 96 -13 -76 171 185 72 -71 -166 -26 -185 -27 -100 -4 84 6 88 20 65 149 -86 28 -53 -51 -38 -109 5 -22 -39 -22 13 34 -52 69 49 76 -125 68 106 57 12 46 -153 -66 -13 52 156 -185 78 -158 -180 23 -28 -13 76 54 59 -33 -5 74 34 28 -62 -97 2 -105 175 12 12 -20 104 42 -47 100 3 -119 -36 -27 -3 6 64 -210 225 -20 -127 109 -144 43 -39 -103 -31 2 72 -9 72 69 47 -10 54 32 63 16 147 -80 -164 157 -89 77 220 -80 97 16 -88 42 -125 86 -45 -56 53 -15 25 -32 34 -67 6 -177 7 3 -101 11 -118 -123 82 35 10 77 4 -13 -32 -61 -65 166 -56 159 -68 -15 228 -126 168 30 -46 25 -66 -116 60 125 -24 96 -100 62 96 -41 -7 -76 89 -33 -41 28 -210 21 92 -42 108 -16 42 -121 -34 -10 -10 -5 -89 -39 -55 1 103 -27 53 4 -55 -93 30 -91 -36 27 -86 151 -3 -36 1 32 -85 -30 -19 -157 92 118 -124 85 93 108 -37 -14 -63 4 17 -48 150 57 -65 -81 43 -58 68 -48 -24 119 -66 6 -29 62 -11 -16 44 -18 97 78 -157 -31 -119 4 173 -31 40 -101 -14 100 46 -88 -68 232 -15 123 183 -203 165 -150 -197 169 -184 -145 94 900000 SS 20210818T142806.3Z 7900.602850 99 1 34.53 2 56.62 94.19 173.10 307.76 0.00 1 0.00 1 0 33 1.045e-03 1.011e-03 7.153e-04 6.832e-04 4.813205e-07 2.229918e-07 3.857013e-08 3.647032e-07 3.361370e-07 229.53 -2.00 3.25 -2.00 339.83 0.00e+00 2.156161e-04 6.149672e-05 9.768843e-06 1.517152e-05 9.249713e-05 294.57 -2.00 20.00 -2.00 337.25 0.00e+00 7.445360e-06 9.341477e-06 7.744137e-07 2.389131e-05 1.564866e-05 294.57 -2.00 20.00 -2.00 346.01 0.00e+00 1.123818e-04 2.781093e-05 1.017304e-05 7.148494e-06 4.565180e-05 294.57 -2.00 20.00 -2.00 344.56 0.00e+00 1.484373e+05 5.689527e+04 2.378985e+04 1.920456e+05 8.643896e+04 274.85 -2.00 10.55 -2.00 351.83 0.00e+00 2.326447e-01 8.179512e-04 1.754417e-03 1.885070e-03 1.084560e-03 229.53 -2.00 3.25 -2.00 330.28 0.00e+00 1.727200e-03 9.106936e-04 1.625529e-04 6.982046e-05 1.059239e-03 294.57 -2.00 20.00 -2.00 328.39 0.00e+00 1.812 0.000 319.50 362.20 4 4.5024e+00 9.1796e-04 1.2808e-02 1.3639e-03 1.4768e-03 7.0508e-03 2.2481e-04 2.0048e-03 2.5546e-04 3.4294e-04 -2.5945e-03 4.3617e-04 3.5638e-04 9.5632e-05 6.6376e-04 2.2145e-04 1.9981e-04 3.0172e-04 6.7779e-05 2.6184e-04 5.2328e-04 3.3573e-04 2.0412e-04 6.5661e-05 4.8103e-04 2.1744e-03 -9.1333e-04 5.2302e-04 1.4674e-04 6.5146e-05 7.8892e-04 1.2745e-04 8.9145e-06 2.1217e-06 6.3514e-07 1.4080e-05 5.8693e-02 -2.7117e-04 -1.6221e-01 5.5400e-02 1.2307e-02 4.0769e-03 8.5028e-02 12 8 8 10 0 0 54.94 18.17 0.25 0.05869 0.06027 24 17 2 8 0 1438.340 15.02 18.17 39.66 21.17 21.88 16.6 952.39 -147 148 16 -105 -141 170 5 206 -105 135 -69 85 23 19 -145 -146 -218 3 -63 13 -59 210 134 30 151 -159 114 -46 64 46 -100 11 -47 2 -32 -82 105 -19 -38 184 -5 -110 131 -37 -67 32 19 79 31 -87 -41 82 -81 46 -164 -219 75 -169 -106 99 89 29 119 -129 -19 144 -6 -45 -103 51 -141 167 -179 -27 15 60 55 -73 24 -169 104 -90 113 25 -13 27 -166 141 -36 12 54 35 97 119 40 -111 -92 -12 3 180 55 56 91 85 241 142 31 122 -91 -146 28 -81 18 214 -115 99 65 -9 -9 -159 41 3 -133 64 -121 -26 -51 -69 -92 25 -111 -5 1 -123 -157 34 -31 18 -91 -24 37 40 6 -28 -172 -73 132 33 -15 24 13 75 7 108 69 -89 150 -54 -71 57 92 -82 193 -109 -23 237 22 15 -41 53 -93 -128 161 47 72 13 5 143 -145 56 -24 -64 -18 -89 61 52 26 -100 52 -16 13 -55 -138 -118 -42 30 13 -52 70 -197 106 -72 -42 -97 212 -171 -105 64 -115 23 84 -35 153 -37 160 -100 101 55 -90 -18 42 10 -57 29 72 -33 96 32 83 -7 72 -147 15 34 -61 29 84 141 -93 -47 -65 -45 -43 -60 30 43 -98 120 -88 -213 78 43 -63 -42 208 -104 191 293 -307 184 -121 -204 192 -180 29 12 900000 -85 81 9 -62 -88 110 3 131 -71 92 -49 61 17 14 -104 -101 -153 2 -44 10 -46 167 115 25 132 -140 98 -39 56 41 -90 10 -40 2 -27 -71 92 -16 -32 153 -4 -94 110 -31 -59 28 18 76 30 -87 -42 83 -84 47 -163 -213 69 -151 -95 91 82 27 112 -121 -17 138 -6 -45 -98 47 -133 161 -177 -26 14 58 54 -70 22 -154 94 -85 107 24 -12 28 -171 139 -35 11 54 36 104 126 41 -102 -79 -10 3 170 53 55 84 76 206 122 28 119 -92 -150 27 -78 17 211 -118 103 69 -10 -9 -161 40 3 -136 68 -134 -30 -57 -76 -100 26 -117 -5 1 -131 -161 34 -31 18 -97 -27 41 43 7 -30 -183 -79 149 37 -17 26 14 80 8 110 63 -80 126 -48 -67 56 95 -88 212 -121 -26 263 24 16 -42 53 -94 -136 171 52 79 14 5 160 -158 57 -24 -63 -18 -97 66 55 28 -107 56 -18 14 -55 -140 -119 -43 31 14 -58 79 -235 129 -87 -50 -113 244 -194 -119 70 -124 25 95 -41 179 -42 173 -102 100 55 -94 -20 48 12 -66 33 84 -40 113 37 99 -8 86 -180 18 40 -73 34 99 164 -106 -54 -75 -51 -50 -70 34 47 -103 120 -83 -204 75 42 -66 -45 224 -110 184 266 -271 154 -102 -177 168 -169 30 12 900000 SS 20210818T151032.6Z 7900.632321 109 1 34.95 2 47.52 100.44 174.42 39.72 0.00 1 0.00 1 0 33 1.271e-03 1.216e-03 8.055e-04 7.814e-04 6.962221e-07 2.516665e-07 3.198816e-08 3.647951e-07 4.082219e-07 229.53 -2.00 3.25 -2.00 339.22 0.00e+00 -4.341199e-05 6.829792e-05 1.318967e-05 1.505890e-05 1.108260e-04 294.56 -2.00 20.00 -2.00 336.59 0.00e+00 1.485288e-05 1.090942e-05 5.649169e-07 2.389055e-05 1.924661e-05 294.56 -2.00 20.00 -2.00 345.48 0.00e+00 2.179185e-05 3.227690e-05 8.711157e-06 7.241377e-06 5.540554e-05 294.56 -2.00 20.00 -2.00 343.93 0.00e+00 2.529140e+02 6.386506e+04 2.112908e+04 1.919091e+05 1.037497e+05 274.85 -2.00 10.55 -2.00 351.55 0.00e+00 1.921134e-01 8.767208e-04 1.450798e-03 1.884866e-03 1.295986e-03 229.53 -2.00 3.25 -2.00 329.94 0.00e+00 -1.576858e-04 9.777717e-04 1.453857e-04 6.955121e-05 1.286288e-03 294.56 -2.00 20.00 -2.00 328.02 0.00e+00 1.478 0.000 319.50 362.20 4 5.0139e+00 1.0519e-03 1.0452e-02 1.3639e-03 1.7884e-03 4.0172e-02 2.4805e-04 1.6376e-03 2.5567e-04 4.0797e-04 -4.8786e-03 4.8663e-04 2.8586e-04 9.0918e-05 7.9364e-04 -5.1251e-04 2.1809e-04 2.5290e-04 6.8656e-05 3.1521e-04 1.8329e-03 3.6786e-04 1.7914e-04 6.4690e-05 5.6929e-04 1.6533e-03 -5.0676e-03 6.0565e-04 1.2493e-04 6.4356e-05 9.9005e-04 2.2310e-04 1.0266e-05 1.8948e-06 6.5301e-07 1.7117e-05 5.7155e-02 -2.6135e-04 -1.9169e-01 6.4448e-02 9.9487e-03 3.9579e-03 1.0591e-01 12 8 8 10 0 0 97.34 18.16 0.25 0.05715 0.05991 17 12 1 8 0 2055.110 15.02 18.16 40.38 21.17 21.88 16.5 955.98 -426 16 407 43 -32 -148 260 32 -44 -102 -13 128 132 -110 -8 -145 -72 144 117 21 -35 103 188 -115 183 -181 134 85 -33 4 -262 45 -39 104 -114 -64 -7 7 -25 75 97 -200 13 37 -154 104 -105 -225 79 7 -84 47 -8 -39 105 -199 -110 -187 -152 74 -34 -123 240 -19 -2 189 149 120 -5 139 -156 159 -197 39 84 167 85 -87 104 -193 -13 -63 -90 187 3 176 -92 158 4 -65 -35 -59 113 7 -85 -97 -62 106 -222 112 175 181 139 5 -169 97 -25 105 -159 13 168 -61 -30 94 -177 150 27 -3 116 -48 -9 171 -175 131 -82 -9 -152 -44 -106 -118 -253 -85 -56 53 -96 -15 -248 125 -75 25 59 -36 -16 -22 55 -47 70 -137 59 85 7 221 -122 217 97 -249 48 -139 -14 183 183 15 129 -106 -11 159 66 48 162 -31 -73 -45 73 -159 43 72 -40 57 -151 123 -3 -91 4 48 139 130 2 3 -82 50 -215 -21 97 -124 -189 -76 -71 -158 102 -310 160 -108 -18 -8 56 -61 -121 -53 -132 79 74 -117 255 -41 14 -139 74 208 -18 93 99 1 138 -120 10 -32 132 -41 67 29 35 -101 20 -13 -10 66 61 35 23 -176 117 -184 50 -12 -46 112 -100 102 57 -181 -92 -91 -35 167 145 -30 110 243 -272 269 -221 -104 294 -175 -196 8 900000 -268 9 253 28 -22 -102 180 22 -32 -77 -10 100 104 -86 -6 -110 -53 107 89 17 -29 89 170 -107 171 -170 124 78 -30 4 -248 43 -36 95 -105 -59 -6 6 -22 66 87 -179 11 33 -139 97 -104 -230 82 7 -88 50 -9 -41 109 -200 -105 -175 -143 70 -33 -120 231 -18 -2 187 150 120 -5 135 -153 157 -198 39 83 165 84 -85 99 -180 -12 -60 -88 186 3 182 -96 160 4 -65 -36 -63 122 7 -88 -92 -53 89 -198 108 174 177 129 5 -146 86 -24 105 -165 14 166 -59 -29 94 -184 157 29 -3 120 -48 -9 170 -181 141 -91 -11 -172 -49 -115 -126 -265 -89 -58 56 -98 -15 -247 126 -79 28 65 -39 -17 -24 58 -51 78 -154 65 94 7 237 -130 218 90 -217 41 -121 -13 178 188 16 140 -115 -12 172 71 50 163 -30 -73 -47 77 -171 47 79 -45 62 -159 123 -3 -88 4 50 148 137 2 4 -88 53 -224 -21 96 -124 -189 -77 -73 -168 114 -362 188 -126 -21 -9 62 -68 -132 -56 -136 84 81 -133 290 -45 14 -138 71 200 -18 99 109 1 154 -135 11 -37 152 -48 77 34 41 -117 23 -15 -11 77 69 38 25 -191 128 -202 55 -13 -51 119 -101 97 52 -166 -85 -86 -35 171 149 -30 102 209 -225 216 -178 -85 244 -157 -191 8 900000