File name: Pandora130s1_Lindenberg_20231029_L2Fit_fwvt1c6d20220715p1-8.txt File generation date: 20231102T155118.5Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c6p1-8 Local principal investigator: Lionel Doppler Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 130 Spectrometer number: 1 Processing software version used: BlickP v1.8.49 Instrument operation file used: Pandora130_OF_v3d20201102.txt Instrument calibration file used: Pandora130s1_CF_v6d20220715.txt Level 1 file used: Pandora130s1_Lindenberg_20231029_L1_smca1c6d20220715p1-8.txt Full location name: DWD Observatory Lindenberg Short location name: Lindenberg Country of location: Germany Location latitude [deg]: 52.2900 Location longitude [deg]: 14.1200 Location altitude [m]: 127 Local noon date: 20231029 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: "AnaLab+fld for 20220715 VP" session 5 from check dispersion First and last pixel inside fitting window: 1657 1807 Nominal wavelengths inside fitting window [nm]: 492.0366 492.1576 492.2786 492.3996 492.5205 492.6414 492.7623 492.8832 493.0041 493.1250 493.2458 493.3666 493.4874 493.6082 493.7290 493.8498 493.9705 494.0912 494.2119 494.3326 494.4533 494.5740 494.6946 494.8152 494.9358 495.0564 495.1770 495.2976 495.4181 495.5386 495.6591 495.7796 495.9001 496.0206 496.1410 496.2614 496.3818 496.5022 496.6226 496.7429 496.8633 496.9836 497.1039 497.2242 497.3445 497.4647 497.5850 497.7052 497.8254 497.9456 498.0657 498.1859 498.3060 498.4261 498.5462 498.6663 498.7864 498.9064 499.0265 499.1465 499.2665 499.3865 499.5064 499.6264 499.7463 499.8662 499.9861 500.1060 500.2259 500.3457 500.4656 500.5854 500.7052 500.8250 500.9447 501.0645 501.1842 501.3039 501.4236 501.5433 501.6629 501.7826 501.9022 502.0218 502.1414 502.2610 502.3805 502.5001 502.6196 502.7391 502.8586 502.9781 503.0975 503.2170 503.3364 503.4558 503.5752 503.6945 503.8139 503.9332 504.0525 504.1718 504.2911 504.4104 504.5296 504.6489 504.7681 504.8873 505.0065 505.1256 505.2448 505.3639 505.4830 505.6021 505.7212 505.8402 505.9593 506.0783 506.1973 506.3163 506.4353 506.5542 506.6732 506.7921 506.9110 507.0299 507.1487 507.2676 507.3864 507.5052 507.6240 507.7428 507.8616 507.9803 508.0991 508.2178 508.3365 508.4552 508.5738 508.6925 508.8111 508.9297 509.0483 509.1669 509.2854 509.4039 509.5225 509.6410 509.7595 509.8779 509.9964 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-252: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 253-403: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20231029T093951.1Z 8702.402675 330 1 14.01 2 67.31 162.20 108.45 336.48 0.00 1 0.00 1 0 15 3.575e-03 3.563e-03 5.578e-04 5.570e-04 2.542122e+03 3.330524e+01 1.950334e+02 -6.000000e+00 1.975569e+02 273.45 -2.00 20.00 -2.00 505.26 0.00e+00 4.639044e-04 1.518896e-05 2.718775e-05 -6.000000e+00 9.927681e-05 273.45 -2.00 20.00 -2.00 500.46 0.00e+00 1.247450e-01 1.110583e-02 1.898081e-02 -6.000000e+00 7.151476e-02 222.74 -2.00 3.85 -2.00 502.05 0.00e+00 2.572 0.000 489.00 513.00 1 5.6018e+00 8.5189e-04 4.0147e-03 -6.0000e+00 5.4850e-03 1.3919e-02 2.1593e-04 5.1020e-04 -6.0000e+00 1.3980e-03 4.9535e-03 8.6069e-04 6.0243e-05 2.7434e-05 -6.0000e+00 4.0006e-04 3.0125e-03 -8.4156e-05 12 1 1 12 1 1 99.80 16.13 1.14 0.00301 0.00898 25 20 1 2 0 538.750 14.99 16.13 16.51 21.58 21.48 26.5 961.59 -730 -430 -223 -170 -42 243 558 570 727 344 224 78 -69 -253 -325 -414 -280 4 176 87 -13 139 188 379 599 483 312 174 119 -434 -535 -483 -171 335 266 63 -80 16 -109 -193 -49 -31 -25 341 359 446 386 300 83 -195 -481 -819 -1022 -812 -443 -113 -290 -187 -106 62 294 409 465 417 466 283 70 -46 -56 -151 -131 -270 -84 40 230 1 -328 -388 -467 -200 -400 -393 -444 -271 -166 -151 -260 -334 -212 -187 -27 374 605 610 444 366 170 -86 -224 -474 -774 -799 -474 77 -173 -223 -367 -359 -255 -197 26 12 85 182 364 472 622 731 457 353 311 129 161 312 281 89 377 271 224 329 93 -25 -292 -462 -447 -229 -7 -9 -13 168 183 301 280 387 305 226 -134 -340 -627 -425 -403 -712 -422 -224 -172 -43 250 582 601 765 360 232 80 -72 -259 -331 -422 -289 4 184 90 -13 145 196 395 624 504 325 179 123 -440 -546 -491 -172 344 273 66 -83 16 -111 -196 -51 -32 -26 351 373 463 400 307 84 -198 -477 -815 -1005 -799 -443 -112 -297 -189 -107 63 296 413 471 422 468 289 70 -46 -55 -150 -129 -267 -84 39 226 1 -320 -382 -455 -194 -389 -384 -438 -262 -162 -149 -258 -333 -211 -186 -27 377 600 607 440 367 167 -82 -217 -452 -734 -766 -454 76 -170 -222 -363 -351 -248 -191 26 12 85 184 362 471 622 731 456 357 310 127 157 304 275 87 369 265 219 320 90 -24 -283 -443 -428 -220 -7 -9 -12 168 180 297 277 384 303 224 -131 -334 -606 -406 -387 SQ 20231029T115026.3Z 8702.493360 385 1 37.73 2 67.15 196.69 110.53 8.10 0.00 1 0.00 1 0 15 3.668e-03 3.653e-03 4.544e-04 4.537e-04 2.517379e+03 2.719313e+01 1.937227e+02 -6.000000e+00 2.027357e+02 273.44 -2.00 20.00 -2.00 505.28 0.00e+00 4.823870e-04 1.235492e-05 2.746510e-05 -6.000000e+00 1.018743e-04 273.44 -2.00 20.00 -2.00 500.48 0.00e+00 9.639659e-02 9.049582e-03 1.882200e-02 -6.000000e+00 7.337214e-02 222.73 -2.00 3.85 -2.00 502.08 0.00e+00 2.555 0.000 489.00 513.00 1 6.1980e+00 6.9409e-04 3.9885e-03 -6.0000e+00 5.6277e-03 1.3237e-02 1.7567e-04 5.0705e-04 -6.0000e+00 1.4339e-03 2.7406e-03 5.8251e-04 4.9218e-05 2.7346e-05 -6.0000e+00 4.1052e-04 -7.8057e-05 -4.5346e-05 12 1 1 12 1 1 98.58 16.13 1.14 -0.00008 0.00396 36 11 1 2 0 1018.740 14.98 16.13 17.97 21.58 21.48 26.7 971.40 -771 -531 -265 -183 -71 119 468 653 660 475 168 179 -87 -321 -256 -446 -430 64 222 32 89 208 339 329 705 376 365 200 76 -547 -716 -534 -259 257 289 18 -37 -51 -53 -196 36 -70 145 278 427 405 529 302 135 -204 -490 -689 -1036 -936 -512 -20 3 -131 -62 37 259 386 376 444 368 285 -43 12 -90 -102 -284 -251 -78 -4 276 53 -309 -533 -379 -257 -390 -401 -450 -219 -50 -146 -170 -198 -223 -166 -13 370 632 545 493 452 202 -149 -216 -549 -722 -700 -482 20 -106 -222 -408 -450 -278 -185 36 -15 18 227 362 466 605 599 590 368 251 105 88 238 281 100 441 292 177 325 -6 -104 -334 -398 -491 -291 -129 4 -64 163 206 279 382 511 268 205 -159 -404 -566 -459 -408 -763 -515 -263 -187 -72 123 482 677 686 491 172 185 -89 -324 -257 -449 -437 66 228 34 93 219 356 347 742 397 383 208 77 -562 -722 -535 -264 260 300 18 -38 -53 -55 -201 37 -71 149 289 437 415 539 313 138 -204 -492 -676 -1006 -911 -506 -20 3 -133 -64 38 265 395 386 454 374 287 -43 12 -90 -101 -277 -245 -76 -4 276 53 -305 -519 -365 -246 -374 -387 -438 -215 -50 -142 -166 -194 -219 -163 -13 368 634 549 495 447 196 -145 -207 -518 -676 -663 -468 19 -106 -218 -398 -446 -273 -182 36 -15 18 227 363 470 612 606 594 367 247 105 87 235 278 99 438 290 175 320 -6 -101 -320 -377 -465 -278 -125 4 -63 160 204 279 382 512 269 205 -157 -392 -553 -444 -397 SQ 20231029T122956.3Z 8702.520791 400 1 19.21 2 69.39 206.74 109.10 17.57 0.00 1 0.00 1 0 15 4.212e-03 4.194e-03 1.191e-03 1.189e-03 2.883718e+03 7.196657e+01 2.178962e+02 -6.000000e+00 2.327769e+02 273.43 -2.00 20.00 -2.00 505.27 0.00e+00 5.522443e-04 3.233465e-05 3.143621e-05 -6.000000e+00 1.169630e-04 273.43 -2.00 20.00 -2.00 500.44 0.00e+00 1.782773e-01 2.374667e-02 2.197930e-02 -6.000000e+00 8.421862e-02 222.73 -2.00 3.85 -2.00 502.04 0.00e+00 2.813 0.000 489.00 513.00 1 7.2562e+00 1.8209e-03 4.4375e-03 -6.0000e+00 6.4599e-03 1.8073e-02 4.6142e-04 5.8024e-04 -6.0000e+00 1.6454e-03 9.1030e-04 3.7643e-04 1.2862e-04 3.0164e-05 -6.0000e+00 4.7134e-04 9.6943e-04 -2.7294e-05 12 9 1 12 33 1 96.62 16.11 1.16 0.00097 0.00358 6 4 1 2 0 2743.750 14.98 16.11 18.97 21.58 21.48 26.5 977.01 -879 -537 -257 -164 156 -91 283 888 787 393 130 111 96 -345 -196 -337 -342 -180 115 258 144 189 123 503 838 568 530 217 240 -444 -305 -400 -180 200 200 -198 59 14 -221 -160 -271 26 136 -6 389 269 588 413 47 -324 -857 -957 -1411 -902 -683 122 -189 -333 -251 66 495 505 393 575 489 271 -75 150 185 -118 -277 -177 -163 101 215 48 -272 -670 -388 -193 -494 -340 -547 -228 -58 -107 -143 -151 -299 -372 113 414 555 533 479 552 89 -176 -348 -518 -599 -790 -618 36 -87 -268 -915 -653 -309 -176 318 34 -97 330 526 340 853 655 790 299 449 205 182 207 282 -47 477 116 232 629 156 -221 -227 -384 -545 -393 -151 50 303 339 377 160 280 409 209 204 -435 -576 -449 -312 -395 -858 -528 -258 -164 160 -96 292 921 818 406 133 116 99 -351 -197 -341 -350 -188 118 269 152 199 130 530 882 599 557 225 245 -458 -308 -403 -184 204 208 -209 62 15 -229 -164 -277 26 140 -6 408 284 614 427 48 -324 -866 -946 -1381 -881 -679 124 -190 -340 -258 67 503 514 402 587 496 273 -74 151 184 -117 -271 -173 -160 100 215 48 -269 -655 -375 -185 -475 -328 -534 -224 -58 -107 -139 -147 -292 -364 111 410 555 535 477 540 88 -172 -332 -486 -558 -746 -598 34 -86 -268 -914 -644 -302 -172 312 34 -96 325 521 339 851 655 785 295 449 202 179 203 277 -47 469 114 228 612 151 -213 -215 -360 -512 -372 -145 49 299 329 369 158 276 405 208 201 -425 -569 -435 -299 -382 SQ 20231029T123737.1Z 8702.526124 404 1 43.45 2 69.94 208.65 108.72 19.38 0.00 1 0.00 1 0 15 3.622e-03 3.619e-03 5.050e-04 5.043e-04 2.897837e+03 3.038427e+01 2.194141e+02 -6.000000e+00 2.001480e+02 273.43 -2.00 20.00 -2.00 505.27 0.00e+00 5.215415e-04 1.378965e-05 3.048610e-05 -6.000000e+00 1.005836e-04 273.43 -2.00 20.00 -2.00 500.47 0.00e+00 1.484610e-01 1.005970e-02 2.206741e-02 -6.000000e+00 7.246026e-02 222.73 -2.00 3.85 -2.00 502.07 0.00e+00 2.885 0.000 489.00 513.00 1 6.4983e+00 7.7182e-04 4.5276e-03 -6.0000e+00 5.5575e-03 1.4364e-02 1.9503e-04 5.8602e-04 -6.0000e+00 1.4166e-03 1.9280e-03 9.3092e-04 5.4480e-05 3.0805e-05 -6.0000e+00 4.0534e-04 1.8710e-03 -7.9867e-05 10 0 0 10 0 0 99.65 16.06 1.05 0.00187 0.00833 64 16 1 2 0 678.830 15.00 16.06 19.08 21.58 21.48 26.7 977.75 -670 -501 -85 -133 -276 141 536 719 689 315 141 133 61 -289 -169 -454 -392 129 159 95 16 30 197 306 605 403 348 295 184 -424 -638 -521 -70 277 257 -28 -164 -120 -18 -254 178 42 -192 265 374 486 556 321 189 -273 -623 -794 -1073 -807 -471 33 -302 -95 -189 67 246 296 537 396 402 275 121 197 4 -115 -248 -251 -137 56 236 97 -311 -472 -433 -411 -462 -352 -381 -259 -72 -93 -196 -348 -300 -159 -70 360 532 497 550 464 170 -116 -231 -590 -682 -734 -402 153 -91 -120 -555 -303 -229 -206 138 -15 7 169 226 518 673 623 604 308 235 -1 147 284 283 59 328 244 278 395 112 -35 -364 -405 -467 -223 -102 3 -10 70 176 251 281 374 344 194 -232 -308 -498 -461 -283 -665 -501 -84 -135 -280 146 560 758 727 331 146 136 62 -299 -174 -467 -395 132 166 101 17 31 204 317 627 418 360 312 191 -431 -637 -517 -70 285 263 -29 -170 -124 -18 -265 185 43 -195 271 385 502 572 327 196 -278 -620 -773 -1068 -804 -461 33 -310 -98 -190 67 247 298 540 399 403 281 122 196 4 -112 -240 -243 -133 55 233 96 -304 -455 -413 -404 -455 -336 -367 -252 -70 -92 -195 -347 -299 -159 -71 363 525 492 541 465 167 -112 -225 -568 -653 -710 -385 150 -89 -119 -548 -295 -221 -199 134 -15 7 171 229 526 685 636 613 310 233 -1 142 276 275 57 320 238 270 382 108 -33 -355 -390 -449 -216 -97 3 -10 69 176 253 284 379 349 196 -231 -301 -479 -440 -270 SQ 20231029T124825.8Z 8702.533632 408 1 32.49 2 70.77 211.30 108.12 21.90 0.00 1 0.00 1 0 22 3.628e-03 3.614e-03 3.330e-04 3.325e-04 2.936407e+03 2.009808e+01 2.208993e+02 -6.000000e+00 2.005144e+02 273.43 -2.00 20.00 -2.00 505.27 0.00e+00 5.215137e-04 9.049088e-06 3.052287e-05 -6.000000e+00 1.007645e-04 273.43 -2.00 20.00 -2.00 500.47 0.00e+00 1.617657e-01 6.628471e-03 2.255443e-02 -6.000000e+00 7.258593e-02 222.72 -2.00 3.85 -2.00 502.07 0.00e+00 3.001 0.001 489.00 513.00 1 5.3798e+00 5.0801e-04 4.6903e-03 -6.0000e+00 5.5672e-03 1.2179e-02 1.2888e-04 5.9719e-04 -6.0000e+00 1.4189e-03 5.7993e-03 5.4409e-04 3.5944e-05 3.0540e-05 -6.0000e+00 4.0606e-04 6.3797e-04 -6.5243e-05 12 1 1 12 1 1 98.70 16.07 1.11 0.00064 0.00441 70 24 1 2 0 457.500 15.01 16.07 19.10 21.58 21.48 26.6 977.31 -749 -510 -250 -120 -66 197 584 638 573 412 195 137 -98 -313 -349 -402 -363 51 222 72 -22 169 286 356 629 504 312 187 123 -450 -605 -525 -219 261 238 -49 -49 -13 -72 -232 -38 7 74 290 409 510 475 310 109 -226 -522 -771 -936 -852 -429 -147 -176 -98 -86 73 260 400 403 426 472 265 67 -25 -24 -132 -299 -217 -113 68 204 8 -366 -405 -319 -317 -364 -462 -438 -420 -90 -182 -300 -241 -234 -120 -30 362 579 585 494 445 184 -125 -290 -528 -736 -714 -414 -24 -94 -243 -413 -348 -285 -140 34 17 103 262 358 520 652 607 570 327 223 69 167 324 327 84 292 343 193 325 154 -153 -332 -412 -595 -230 -107 -159 -26 141 221 279 378 437 349 213 -123 -389 -492 -528 -395 -737 -506 -246 -121 -67 205 599 662 595 426 199 141 -100 -316 -350 -404 -368 52 228 75 -23 178 301 376 663 532 329 195 126 -462 -610 -526 -222 265 248 -51 -51 -13 -75 -238 -39 7 77 295 419 524 486 322 112 -227 -525 -758 -909 -829 -423 -149 -178 -100 -88 75 266 409 414 438 482 268 67 -25 -24 -130 -293 -212 -111 67 204 8 -363 -396 -308 -305 -350 -447 -427 -413 -90 -178 -295 -237 -231 -118 -30 361 583 591 496 440 178 -122 -277 -497 -707 -675 -400 -23 -94 -239 -406 -346 -281 -138 34 17 103 263 362 526 662 618 577 328 221 67 166 321 325 82 284 333 187 314 152 -149 -319 -393 -567 -221 -104 -154 -26 140 220 281 372 432 345 209 -123 -381 -473 -504 -378 SQ 20231029T131045.1Z 8702.549133 415 1 6.14 2 72.68 216.65 106.68 27.02 0.00 1 0.00 1 0 15 3.699e-03 3.686e-03 4.405e-04 4.400e-04 3.187237e+03 2.671046e+01 2.373069e+02 -6.000000e+00 2.043983e+02 273.43 -2.00 20.00 -2.00 505.27 0.00e+00 5.865233e-04 1.201060e-05 3.447672e-05 -6.000000e+00 1.027118e-04 273.43 -2.00 20.00 -2.00 500.49 0.00e+00 2.093151e-01 8.770820e-03 2.485673e-02 -6.000000e+00 7.397826e-02 222.72 -2.00 3.85 -2.00 502.08 0.00e+00 3.311 0.001 489.00 513.00 1 4.2107e+00 6.7270e-04 5.1752e-03 -6.0000e+00 5.6741e-03 1.1641e-02 1.7004e-04 6.5387e-04 -6.0000e+00 1.4458e-03 1.7788e-02 5.4848e-04 4.7428e-05 3.2967e-05 -6.0000e+00 4.1391e-04 1.1248e-03 -5.4800e-05 12 1 1 12 1 1 61.61 16.13 1.12 0.00112 0.00493 38 71 1 2 0 157.150 14.99 16.13 19.26 21.58 21.48 26.7 978.51 -765 -563 -221 -157 -152 249 581 602 544 497 126 160 -123 -231 -440 -393 -344 10 216 33 -24 183 343 400 609 536 309 165 96 -472 -604 -437 -196 221 348 -16 -49 6 -89 -176 -109 15 40 325 388 463 584 362 212 -105 -502 -865 -900 -882 -444 -221 -160 -65 -36 81 256 401 483 369 378 287 87 -82 -91 -189 -267 -151 -183 -5 198 -6 -411 -453 -333 -317 -323 -397 -454 -264 -141 -134 -236 -312 -214 -198 2 417 643 624 482 423 121 -162 -315 -509 -750 -696 -468 39 -107 -277 -426 -344 -348 -195 -12 52 130 267 365 536 642 732 598 334 255 72 222 429 226 218 281 284 178 249 217 -120 -321 -387 -405 -244 -59 -184 -38 107 293 278 419 424 238 182 -101 -458 -662 -508 -381 -753 -558 -219 -160 -156 260 599 628 568 516 130 166 -126 -234 -444 -396 -351 11 224 35 -25 189 355 414 631 556 320 173 99 -475 -611 -440 -196 226 356 -16 -51 6 -90 -182 -113 16 41 333 401 480 602 370 218 -106 -508 -857 -879 -864 -441 -220 -163 -67 -36 82 258 405 489 374 381 292 88 -82 -91 -188 -263 -149 -181 -5 195 -6 -400 -445 -323 -307 -313 -387 -445 -261 -137 -132 -233 -310 -213 -197 2 419 637 620 477 421 118 -159 -302 -481 -722 -661 -455 38 -105 -276 -422 -337 -339 -190 -12 52 130 271 363 536 644 735 599 339 254 71 217 419 222 215 276 279 175 243 210 -116 -312 -372 -389 -237 -57 -180 -38 105 289 276 418 425 238 182 -99 -453 -645 -490 -369