File name: Pandora135s1_ManhattanNY-CCNY_20230928_L2Fit_fsus1c16d20211023p1-8.txt File generation date: 20241024T165158.5Z Data description: Level 2 spectral fitting results file Data file version: fsus1c16p1-8 Local principal investigator: Maria Tzortziou Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 135 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora135_OF_v3d20200205.txt Instrument calibration file used: Pandora135s1_CF_v16d20211023.txt Level 1 file used: Pandora135s1_ManhattanNY-CCNY_20230928_L1_smca1c16d20211023p1-8.txt Full location name: ManhattanNY-CCNY Short location name: ManhattanNY-CCNY Country of location: USA Location latitude [deg]: 40.8153 Location longitude [deg]: -73.9505 Location altitude [m]: 34 Local noon date: 20230928 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 15, but with new Reference day in spring 2023. First and last pixel inside fitting window: 241 386 Nominal wavelengths inside fitting window [nm]: 306.0554 306.1961 306.3368 306.4775 306.6182 306.7589 306.8995 307.0402 307.1808 307.3215 307.4621 307.6027 307.7433 307.8839 308.0245 308.1650 308.3056 308.4461 308.5867 308.7272 308.8677 309.0082 309.1487 309.2892 309.4296 309.5701 309.7105 309.8510 309.9914 310.1318 310.2722 310.4126 310.5530 310.6933 310.8337 310.9740 311.1144 311.2547 311.3950 311.5353 311.6756 311.8159 311.9561 312.0964 312.2366 312.3769 312.5171 312.6573 312.7975 312.9377 313.0778 313.2180 313.3582 313.4983 313.6384 313.7786 313.9187 314.0588 314.1989 314.3389 314.4790 314.6191 314.7591 314.8991 315.0392 315.1792 315.3192 315.4591 315.5991 315.7391 315.8790 316.0190 316.1589 316.2988 316.4387 316.5786 316.7185 316.8584 316.9983 317.1381 317.2780 317.4178 317.5576 317.6974 317.8372 317.9770 318.1168 318.2565 318.3963 318.5360 318.6757 318.8155 318.9552 319.0949 319.2345 319.3742 319.5139 319.6535 319.7932 319.9328 320.0724 320.2120 320.3516 320.4912 320.6307 320.7703 320.9098 321.0494 321.1889 321.3284 321.4679 321.6074 321.7469 321.8864 322.0258 322.1653 322.3047 322.4441 322.5835 322.7229 322.8623 323.0017 323.1410 323.2804 323.4197 323.5591 323.6984 323.8377 323.9770 324.1163 324.2556 324.3948 324.5341 324.6733 324.8125 324.9517 325.0910 325.2301 325.3693 325.5085 325.6477 325.7868 325.9259 326.0651 326.2042 326.3433 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20230928T184630.6Z 8671.782299 511 1 2.23 2 50.92 220.09 130.89 51.99 0.00 1 0.00 1 0 66 3.968e-03 2.910e-03 5.039e-03 3.319e-03 3.100360e-07 1.267485e-06 7.931783e-08 4.443907e-07 1.832229e-06 227.80 -2.00 3.51 -2.00 320.78 0.00e+00 1.450954e-03 4.225766e-04 4.428438e-05 3.560823e-05 4.892766e-04 286.26 -2.00 20.00 -2.00 320.47 0.00e+00 -6.766908e-04 6.124372e-04 1.187728e-05 2.951774e-05 8.342325e-04 286.26 -2.00 20.00 -2.00 320.92 0.00e+00 -3.228571e-04 7.706463e-04 4.178231e-05 1.585287e-05 8.852752e-04 286.26 -2.00 20.00 -2.00 320.70 0.00e+00 1.840388e-01 4.308163e-03 1.500656e-04 1.684036e-03 4.925247e-03 237.21 5.93 0.00 0.22 8.53 316.22 0.00e+00 4.697042e-04 1.879707e-04 5.245690e-05 2.712049e-05 1.285064e-04 286.26 -2.00 20.00 -2.00 315.15 0.00e+00 1.583 0.000 303.00 329.40 4 3.9784e+00 1.3542e-02 1.5344e-02 2.2517e-03 1.5609e-02 3.4699e-02 1.6408e-02 2.2128e-03 3.0277e-04 1.6704e-02 4.3456e-03 8.7356e-03 2.9171e-04 1.0195e-04 9.3338e-03 -2.5968e-03 3.1778e-03 3.0085e-04 2.8673e-05 3.4610e-03 -3.8857e-03 2.3023e-03 1.4537e-04 4.6161e-05 2.2609e-03 1.9689e-03 -7.9386e-05 2.3911e-03 1.2762e-04 1.0519e-05 1.7573e-03 1.1982e-03 9.3392e-05 3.5999e-06 9.3706e-07 1.1582e-04 9.4664e-03 0.0000e+00 1.1317e-01 3.3515e-01 4.5732e-03 6.8320e-04 3.5702e-01 12 9 9 12 1 1 -16.64 20.97 0.18 0.00947 0.01861 3 24 1 5 0 554.640 25.68 20.00 20.97 24.67 23.8 1002.95 1287 -44 178 -490 -411 340 -549 -496 -1319 1048 -597 -253 400 359 -388 311 870 -18 -759 -206 -171 -585 529 -60 612 397 -3 -60 -1225 886 180 401 -38 498 -278 567 -105 -172 17 502 240 -434 111 -793 84 56 -96 531 -93 -28 -301 190 -236 663 -231 -84 -512 365 -27 118 -172 -320 -446 -420 244 -131 -215 -626 346 432 -366 104 -13 -77 9 -139 673 -166 -131 -46 535 31 201 30 -237 -353 625 349 -124 -90 348 -163 274 -332 252 153 -454 -36 20 -176 -331 38 40 388 -225 115 -167 71 -89 100 -233 102 -176 -96 353 -3 -145 239 -154 101 350 400 -239 40 -347 142 -273 60 -287 280 152 97 -105 129 -362 -65 -44 123 -15 -394 271 -259 365 -92 57 23 322 -12 51 -139 -118 101 -185 -178 -511 407 -240 -104 168 154 -165 133 387 -8 -354 -94 -76 -242 211 -25 268 187 -2 -27 -550 425 97 236 -25 349 -195 405 -75 -123 12 359 166 -292 74 -553 62 42 -74 417 -72 -22 -235 150 -187 519 -195 -74 -458 329 -23 96 -135 -261 -396 -392 235 -126 -200 -562 286 333 -281 80 -11 -69 9 -136 680 -175 -143 -53 609 36 226 32 -237 -342 579 333 -126 -98 401 -192 325 -380 273 159 -500 -41 24 -211 -413 48 52 519 -302 151 -208 83 -101 113 -269 123 -222 -124 448 -4 -176 283 -179 114 397 469 -290 49 -434 179 -350 81 -397 395 214 138 -147 179 -499 -88 -60 173 -22 -612 436 -429 616 -154 96 38 SS 20230928T193518.7Z 8671.816188 539 1 4.96 2 57.62 232.66 123.26 63.03 0.00 1 0.00 1 0 49 3.231e-03 1.641e-03 2.851e-03 1.577e-03 4.781229e-08 5.925390e-07 2.338242e-08 4.444411e-07 1.484084e-06 227.79 -2.00 3.51 -2.00 321.19 0.00e+00 3.459959e-04 2.059247e-04 1.879487e-05 3.568721e-05 3.938622e-04 286.26 -2.00 20.00 -2.00 320.95 0.00e+00 1.974141e-04 2.888326e-04 2.780058e-06 2.954885e-05 6.778167e-04 286.26 -2.00 20.00 -2.00 321.21 0.00e+00 2.185681e-04 3.891774e-04 2.267123e-05 1.592425e-05 7.207464e-04 286.26 -2.00 20.00 -2.00 321.09 0.00e+00 2.148085e-01 2.135968e-03 5.924857e-05 1.684847e-03 4.028591e-03 232.55 2.46 0.00 0.19 6.95 316.97 0.00e+00 -1.512193e-04 1.035449e-04 3.136820e-06 2.712578e-05 1.050367e-04 286.26 -2.00 20.00 -2.00 315.83 0.00e+00 1.861 0.000 303.00 329.40 4 3.1931e+00 6.1592e-03 1.8031e-02 2.2516e-03 1.2668e-02 1.5194e-02 7.9823e-03 1.8859e-03 3.0805e-04 1.3620e-02 -2.0322e-03 4.2803e-03 2.2787e-04 1.0844e-04 7.5475e-03 -6.0171e-04 1.6833e-03 1.1984e-04 3.3578e-05 2.8909e-03 1.6463e-03 1.1683e-03 5.3179e-05 5.2383e-05 1.8719e-03 3.1617e-03 1.6377e-03 1.0850e-03 3.7561e-05 9.9884e-06 1.1317e-03 2.0507e-04 4.4661e-05 1.6083e-06 9.7476e-07 9.4148e-05 1.8116e-02 0.0000e+00 -1.2264e-01 1.4878e-01 2.3383e-03 5.7467e-04 2.6829e-01 12 9 9 12 1 1 99.87 21.07 0.19 0.01812 0.01968 20 56 1 5 0 235.590 25.79 20.00 21.07 25.71 23.9 1010.64 -185 850 -1911 360 -631 120 -116 206 -72 116 1276 -518 57 -663 235 -745 466 20 62 117 428 -220 -646 616 383 582 -914 522 -153 -77 184 213 54 -169 115 -105 324 -146 265 -114 65 -374 92 -260 -181 263 -17 -96 31 47 -359 31 -261 249 -119 -8 215 -34 -40 -72 -183 -192 302 -140 -152 168 122 -68 404 -57 -172 236 -295 352 -45 26 -144 -199 -76 166 -271 111 131 14 -39 93 396 -28 -110 -207 128 28 102 -30 -59 14 1 1 -7 -56 -126 158 -105 105 -129 17 57 -79 65 8 99 115 -133 -103 151 -138 88 -19 -242 200 2 17 32 6 0 175 -382 -84 -46 226 149 -5 81 -93 24 -190 -44 -34 -26 105 47 5 54 -75 -44 40 -34 173 -403 76 -137 27 -30 58 -22 36 403 -172 19 -232 81 -263 165 7 24 45 158 -76 -219 215 144 227 -370 203 -59 -31 84 113 32 -105 74 -67 207 -93 173 -73 40 -226 57 -164 -122 180 -12 -68 22 35 -265 23 -193 184 -92 -6 185 -29 -32 -55 -135 -153 255 -126 -142 155 109 -58 325 -43 -124 178 -239 309 -43 25 -143 -206 -82 188 -307 125 144 15 -39 86 367 -27 -114 -225 150 34 120 -33 -64 15 1 2 -8 -68 -156 199 -138 144 -176 22 72 -96 76 10 119 146 -172 -136 196 -178 111 -24 -284 226 2 21 39 8 0 230 -516 -117 -66 330 218 -8 119 -132 34 -262 -63 -49 -41 171 78 9 94 -132 -77 70 SS 20230928T193934.6Z 8671.819151 542 1 46.70 2 58.27 233.66 122.56 63.91 0.00 1 0.00 1 0 49 2.987e-03 1.488e-03 2.507e-03 1.114e-03 -1.230594e-07 4.149397e-07 2.304571e-08 4.445007e-07 1.370822e-06 227.79 -2.00 3.51 -2.00 321.63 0.00e+00 5.171904e-04 1.494154e-04 1.413644e-05 3.580457e-05 3.628511e-04 286.26 -2.00 20.00 -2.00 321.55 0.00e+00 1.754178e-04 2.049718e-04 9.041915e-06 2.955134e-05 6.264983e-04 286.26 -2.00 20.00 -2.00 321.53 0.00e+00 6.202852e-04 2.965158e-04 4.354840e-05 1.598751e-05 6.662133e-04 286.26 -2.00 20.00 -2.00 321.54 0.00e+00 2.166137e-01 1.588435e-03 8.493117e-05 1.685293e-03 3.725631e-03 229.15 1.78 0.00 0.18 6.43 317.75 0.00e+00 5.704485e-05 8.704918e-05 1.088817e-05 2.713342e-05 9.727700e-05 286.26 -2.00 20.00 -2.00 316.56 0.00e+00 1.894 0.000 303.00 329.40 4 4.4290e+00 4.2506e-03 1.8361e-02 2.2510e-03 1.1699e-02 1.2674e-02 5.8968e-03 1.9687e-03 3.0875e-04 1.2588e-02 6.4067e-03 3.1688e-03 2.1798e-04 1.1572e-04 6.9567e-03 -3.9034e-03 1.2885e-03 7.4228e-05 4.1850e-05 2.6729e-03 1.1671e-03 8.7812e-04 3.6174e-05 5.8417e-05 1.7410e-03 8.8212e-04 1.8022e-03 8.5751e-04 5.4924e-05 1.4050e-05 9.9302e-04 1.7066e-04 3.2392e-05 1.7747e-06 1.0113e-06 8.7033e-05 1.8301e-02 0.0000e+00 1.3745e-01 1.0645e-01 1.7766e-03 4.7632e-04 2.4470e-01 11 9 0 11 8 0 99.99 21.09 0.28 0.01830 0.01960 161 45 1 5 0 290.000 25.79 20.00 21.09 25.89 24.0 1012.67 1185 -809 380 -408 556 705 777 -663 272 636 -410 -397 -303 -45 -84 -1136 -775 402 -326 167 -21 599 56 476 161 431 397 -727 147 -266 484 -289 -22 131 153 2 -186 99 -302 241 -308 126 75 247 54 51 31 148 75 -240 112 -295 175 -39 228 -80 206 -110 -149 -220 -161 276 -112 -183 -284 139 -207 388 31 289 -120 -66 0 -109 77 -44 66 -158 144 89 -12 22 41 -36 55 2 -65 -84 -253 111 195 -50 124 60 -184 77 29 -52 29 -202 -20 -57 -18 52 190 -42 -40 74 -54 -1 -166 -53 -111 176 68 191 139 -59 -561 7 52 -7 223 -146 159 97 -228 -14 -44 106 150 -136 22 -50 -66 139 -166 45 -24 75 -47 64 -42 8 43 -43 160 -123 60 -64 88 124 148 -145 63 153 -102 -102 -80 -12 -22 -312 -223 121 -102 51 -6 159 15 130 47 137 129 -224 44 -88 186 -129 -11 69 84 1 -105 56 -170 132 -171 68 40 139 31 31 20 97 50 -163 75 -195 115 -27 166 -61 165 -87 -113 -154 -109 201 -89 -159 -246 119 -178 307 23 194 -81 -45 0 -90 70 -41 64 -163 153 99 -14 25 45 -37 52 2 -56 -78 -250 117 227 -59 149 67 -196 78 31 -58 35 -251 -25 -74 -24 72 265 -55 -51 88 -63 -1 -198 -68 -148 239 91 247 178 -72 -653 8 60 -8 282 -187 206 128 -316 -19 -66 161 233 -206 34 -73 -98 201 -241 70 -40 126 -84 118 -80 16 81 -80 SS 20230928T195637.6Z 8671.830991 554 1 45.87 2 60.93 237.52 119.68 67.28 0.00 1 0.00 1 0 49 3.316e-02 8.224e-03 9.339e-03 3.443e-03 -5.603971e-06 1.279587e-06 7.535262e-08 4.445456e-07 1.520786e-05 227.79 -2.00 3.51 -2.00 321.85 0.00e+00 2.093815e-03 4.727804e-04 2.659925e-05 3.586339e-05 4.032942e-03 286.26 -2.00 20.00 -2.00 321.82 0.00e+00 2.631074e-03 6.303583e-04 1.598354e-05 2.957092e-05 6.964893e-03 286.26 -2.00 20.00 -2.00 321.68 0.00e+00 1.299948e-03 9.985304e-04 1.830924e-04 1.601287e-05 7.390015e-03 286.26 -2.00 20.00 -2.00 321.74 0.00e+00 2.234854e-01 4.703627e-03 4.889219e-04 1.685323e-03 4.184492e-02 200.03 4.75 0.00 0.22 72.49 318.11 0.00e+00 -1.683941e-04 2.998677e-04 1.704409e-05 2.713943e-05 1.081382e-03 286.26 -2.00 20.00 -2.00 317.01 0.00e+00 2.049 0.000 303.00 329.40 4 6.3268e+00 1.0708e-02 1.9890e-02 2.2512e-03 1.3263e-01 -1.2683e-02 1.5311e-02 3.1081e-03 3.1203e-04 1.4117e-01 3.7779e-02 8.8848e-03 8.5145e-04 1.2006e-04 7.8145e-02 -1.9863e-02 4.1989e-03 2.7115e-04 4.9983e-05 3.0231e-02 8.3051e-03 2.8663e-03 1.1251e-04 6.3578e-05 1.9515e-02 1.1309e-04 1.5334e-03 2.6773e-03 2.1084e-04 1.6547e-05 8.9742e-03 -2.2593e-04 1.0263e-04 4.6525e-06 1.0328e-06 9.6642e-04 1.8552e-02 0.0000e+00 1.3144e+00 3.1613e-01 2.8352e-03 4.2943e-04 2.6174e+00 12 9 8 11 40 0 99.88 21.13 -0.19 0.01855 0.01683 12 3 1 5 0 3822.380 25.79 20.00 21.13 26.52 23.8 1015.65 -3010 118 -2094 2059 -233 2108 -12297 -8120 600 3229 -599 717 -2168 -607 -1200 32606 -3142 280 479 735 1251 1650 136 -5031 -2193 2415 -939 -1161 2606 -97 1329 -997 1657 516 381 -24 -536 1680 54 1782 -848 453 449 -554 -1153 791 -215 1169 1782 -1748 -1128 -696 -759 760 1372 -473 440 -916 -681 -32 -1406 -732 -911 -773 -513 -88 75 1118 877 -264 -481 -595 -543 108 281 -558 881 -232 287 274 548 -361 389 70 -346 -198 -689 -900 -590 1248 577 568 -45 137 355 -57 -796 -455 160 -421 656 -39 -153 425 511 177 -42 -76 -199 -559 -288 503 -526 727 -220 602 404 243 -3048 740 178 -116 160 249 550 -378 -241 -429 107 132 504 -582 106 48 -528 -19 155 -30 -488 251 116 349 141 -325 149 -18 -314 13 -255 239 -29 282 -2168 -1564 115 629 -124 152 -487 -137 -270 5529 -779 71 126 191 304 373 32 -1250 -572 652 -270 -316 698 -28 446 -397 741 254 196 -13 -285 871 29 903 -429 221 219 -287 -642 455 -127 700 1083 -1117 -711 -441 -479 490 914 -348 339 -711 -485 -21 -940 -505 -713 -637 -438 -74 60 859 608 -173 -304 -397 -396 88 244 -518 841 -231 305 297 605 -400 421 70 -327 -176 -602 -840 -588 1315 675 679 -53 155 379 -58 -854 -513 189 -508 816 -51 -207 601 723 241 -54 -94 -230 -651 -350 631 -710 990 -297 784 517 296 -3663 837 205 -138 204 324 725 -513 -340 -624 162 205 794 -905 164 72 -788 -28 228 -47 -813 434 215 661 276 -629 289 -35 SS 20230928T201202.2Z 8671.841692 560 1 45.37 2 63.44 240.82 117.03 70.19 0.00 1 0.00 1 0 33 1.603e-02 5.360e-03 9.361e-03 3.120e-03 -4.537889e-06 1.152645e-06 8.385875e-08 4.445805e-07 7.294525e-06 227.79 -2.00 3.51 -2.00 321.98 0.00e+00 2.337140e-03 4.300591e-04 6.969242e-05 3.590161e-05 1.918617e-03 286.26 -2.00 20.00 -2.00 321.98 0.00e+00 2.122501e-03 5.693609e-04 9.887746e-06 2.958128e-05 3.370645e-03 286.26 -2.00 20.00 -2.00 321.78 0.00e+00 6.526893e-04 9.217438e-04 7.400603e-05 1.596585e-05 3.572118e-03 286.26 -2.00 20.00 -2.00 321.87 0.00e+00 2.495828e-01 4.518301e-03 2.101632e-04 1.685647e-03 2.005966e-02 211.79 4.15 0.00 0.16 34.50 318.41 0.00e+00 -1.047209e-04 2.908841e-04 4.421190e-05 2.714132e-05 5.279578e-04 286.26 -2.00 20.00 -2.00 317.26 0.00e+00 2.224 0.000 303.00 329.40 4 5.9669e+00 1.0225e-02 2.1563e-02 2.2518e-03 6.2661e-02 9.4139e-03 1.5584e-02 2.4978e-03 3.1241e-04 6.7431e-02 3.2963e-02 8.6428e-03 8.3046e-04 1.2189e-04 3.6919e-02 -2.8392e-02 4.1976e-03 3.7202e-04 5.7245e-05 1.4498e-02 1.1779e-02 2.7520e-03 9.7450e-05 6.6992e-05 9.7715e-03 1.3318e-04 -8.3938e-03 2.1612e-03 2.0431e-04 1.7952e-05 3.9432e-03 -1.4685e-04 9.3035e-05 4.9177e-06 1.0447e-06 4.6745e-04 1.8325e-02 0.0000e+00 7.0436e-01 2.7041e-01 7.7133e-03 3.8443e-04 1.1903e+00 12 9 8 11 8 0 99.93 21.16 0.05 0.01832 0.01720 15 4 1 5 0 3024.150 25.90 20.00 21.16 26.57 23.9 1016.18 -2452 5947 -4303 5857 -863 4052 5951 -8075 3189 85 -1250 -3869 1473 -980 806 -3590 604 -340 152 1518 271 3238 -1993 2024 74 2846 -3313 528 595 589 368 585 921 -25 134 -1453 140 -788 1306 308 -438 904 1969 -866 -862 142 -183 682 562 -549 -877 32 -1102 1413 619 21 -344 -92 -545 215 -748 -1183 -656 -762 407 -173 803 23 1284 -122 -119 -86 -841 145 -267 -182 680 1 186 455 -25 302 288 -60 -449 -494 -430 -577 -91 318 1032 85 256 345 77 -215 -901 -371 8 -290 272 167 -123 127 -55 350 -69 89 -455 -26 -559 -181 -328 268 435 406 790 73 -2766 50 113 446 339 209 -110 258 -227 -10 -50 267 353 -456 -3 8 61 -103 82 -23 -129 127 42 287 -160 -14 -84 -35 -227 564 -474 586 -95 477 782 -1377 533 15 -235 -774 288 -200 161 -768 131 -79 36 357 61 665 -426 439 18 721 -918 134 149 161 118 216 391 -11 63 -712 68 -384 643 151 -211 421 913 -435 -449 77 -105 399 337 -338 -538 19 -660 854 405 14 -253 -67 -382 139 -477 -816 -493 -624 331 -141 641 17 881 -77 -75 -55 -619 115 -234 -164 636 1 193 493 -28 333 304 -61 -415 -431 -369 -529 -89 334 1191 101 299 386 82 -217 -959 -414 10 -356 336 217 -165 179 -78 476 -91 109 -531 -31 -686 -230 -445 368 586 531 1011 90 -3330 57 131 536 438 276 -149 355 -326 -15 -77 421 553 -724 -5 12 89 -153 123 -37 -218 223 77 556 -313 -28 -165 -70 SS 20230928T202704.7Z 8671.852138 565 1 46.83 2 65.97 243.90 114.39 72.91 0.00 1 0.00 1 0 49 4.916e-02 7.820e-03 1.661e-02 4.138e-03 -5.774562e-06 1.521221e-06 1.252412e-07 4.446706e-07 2.214156e-05 227.79 -2.00 3.51 -2.00 322.37 0.00e+00 3.223921e-03 5.840299e-04 8.114148e-05 3.598777e-05 5.902641e-03 286.26 -2.00 20.00 -2.00 322.51 0.00e+00 1.721288e-03 7.622829e-04 2.610816e-05 2.959220e-05 1.034744e-02 286.26 -2.00 20.00 -2.00 322.07 0.00e+00 1.161694e-03 1.343463e-03 3.413463e-04 1.591874e-05 1.095924e-02 286.26 -2.00 20.00 -2.00 322.23 0.00e+00 2.684215e-01 6.321378e-03 1.141476e-03 1.685743e-03 6.217191e-02 206.94 5.29 0.00 0.16 106.68 319.10 0.00e+00 -3.598212e-04 4.625696e-04 2.234975e-04 2.713809e-05 1.617983e-03 286.26 -2.00 20.00 -2.00 317.94 0.00e+00 2.438 0.000 303.00 329.40 4 5.9961e+00 1.3412e-02 2.3713e-02 2.2522e-03 1.9537e-01 -1.3349e-03 2.1652e-02 6.8949e-03 3.1458e-04 2.0820e-01 4.7828e-02 1.2015e-02 2.1824e-03 1.2810e-04 1.1458e-01 -3.2872e-02 6.4414e-03 5.2906e-04 7.5947e-05 4.4750e-02 8.2765e-03 4.0036e-03 2.3850e-04 7.5034e-05 2.9653e-02 1.0196e-04 -1.9883e-04 2.9938e-03 3.3240e-04 2.0468e-05 8.6492e-03 -1.3813e-04 1.2642e-04 7.2908e-06 1.0565e-06 1.4333e-03 1.8833e-02 0.0000e+00 6.8520e-01 3.4549e-01 5.2631e-03 4.0655e-04 3.5742e+00 12 8 8 10 0 0 99.99 21.17 0.32 0.01883 0.01778 32 9 1 5 0 1462.940 25.90 20.00 21.17 26.31 24.0 1014.49 -14490 -2131 -6871 4151 -4481 4643 -988 -10050 -648 4337 -1709 -6242 -2175 -2534 -505 49894 379 -2251 575 392 2464 5819 -2415 -433 -2587 3872 -4113 -2046 122 1375 2508 1001 1681 689 -41 -1502 -1484 -181 2488 1392 1072 627 1659 -835 -1604 -749 -231 1143 2023 -584 -1040 785 -1766 2237 1468 -535 262 -806 516 -397 -1408 -1629 -1445 -1086 109 7 1047 34 313 244 -1026 719 -615 -257 229 153 128 -251 -292 59 206 454 38 -459 -277 -1002 -582 -529 146 245 1016 764 158 -373 88 -41 -674 -948 55 -81 418 125 71 338 592 154 -136 609 -346 -316 -672 -37 -253 553 1122 932 863 -246 -3227 163 141 -93 318 -198 139 258 -479 -182 -128 274 333 -550 119 39 -620 -119 -33 54 -174 161 132 203 69 -178 310 -140 -1027 -149 -539 292 -360 386 -100 -1239 -80 536 -233 -928 -320 -383 -77 4762 63 -395 106 72 420 900 -403 -75 -503 773 -920 -425 25 301 637 299 579 263 -17 -629 -623 -75 1002 559 423 245 647 -353 -735 -361 -117 587 1057 -319 -566 410 -941 1186 844 -342 170 -530 321 -232 -817 -1024 -991 -808 83 5 754 23 196 140 -575 422 -416 -195 184 131 114 -240 -288 61 217 474 38 -443 -244 -846 -482 -454 139 258 1134 902 184 -421 90 -40 -693 -1061 65 -96 513 162 98 475 838 217 -179 733 -410 -376 -840 -48 -346 762 1508 1217 1078 -306 -3947 183 161 -115 406 -268 191 363 -708 -275 -202 441 546 -914 190 62 -960 -181 -52 87 -308 296 260 410 143 -377 645 -290