File name: Pandora135s1_ManhattanNY-CCNY_20240119_L2Fit_fwvt1c16d20211023p1-8.txt File generation date: 20241024T192253.3Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c16p1-8 Local principal investigator: Maria Tzortziou Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 135 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora135_OF_v3d20200205.txt Instrument calibration file used: Pandora135s1_CF_v16d20211023.txt Level 1 file used: Pandora135s1_ManhattanNY-CCNY_20240119_L1_smca1c16d20211023p1-8.txt Full location name: ManhattanNY-CCNY Short location name: ManhattanNY-CCNY Country of location: USA Location latitude [deg]: 40.8153 Location longitude [deg]: -73.9505 Location altitude [m]: 34 Local noon date: 20240119 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 15, but with new Reference day in spring 2023. First and last pixel inside fitting window: 1654 1804 Nominal wavelengths inside fitting window [nm]: 492.0072 492.1283 492.2493 492.3704 492.4914 492.6124 492.7334 492.8544 492.9753 493.0963 493.2172 493.3381 493.4590 493.5799 493.7007 493.8216 493.9424 494.0632 494.1840 494.3048 494.4255 494.5463 494.6670 494.7877 494.9084 495.0290 495.1497 495.2703 495.3910 495.5116 495.6321 495.7527 495.8733 495.9938 496.1143 496.2348 496.3553 496.4758 496.5962 496.7167 496.8371 496.9575 497.0779 497.1982 497.3186 497.4389 497.5592 497.6795 497.7998 497.9201 498.0403 498.1605 498.2808 498.4009 498.5211 498.6413 498.7614 498.8816 499.0017 499.1218 499.2418 499.3619 499.4819 499.6020 499.7220 499.8420 499.9619 500.0819 500.2018 500.3218 500.4417 500.5616 500.6814 500.8013 500.9211 501.0409 501.1608 501.2805 501.4003 501.5201 501.6398 501.7595 501.8792 501.9989 502.1186 502.2382 502.3578 502.4775 502.5971 502.7166 502.8362 502.9558 503.0753 503.1948 503.3143 503.4338 503.5532 503.6727 503.7921 503.9115 504.0309 504.1503 504.2696 504.3890 504.5083 504.6276 504.7469 504.8662 504.9854 505.1047 505.2239 505.3431 505.4623 505.5814 505.7006 505.8197 505.9388 506.0579 506.1770 506.2961 506.4151 506.5342 506.6532 506.7722 506.8912 507.0101 507.1291 507.2480 507.3669 507.4858 507.6047 507.7235 507.8424 507.9612 508.0800 508.1988 508.3175 508.4363 508.5550 508.6738 508.7925 508.9111 509.0298 509.1485 509.2671 509.3857 509.5043 509.6229 509.7415 509.8600 509.9785 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-402: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20240119T150359.2Z 8784.627768 191 1 46.74 2 67.46 148.87 107.03 45.30 0.00 1 0.00 1 0 15 2.441e-03 2.429e-03 8.522e-04 8.513e-04 1.457821e+03 4.826126e+01 1.095527e+02 -6.000000e+00 1.335756e+02 275.20 -2.00 20.00 -2.00 505.27 0.00e+00 1.663326e-03 2.317616e-05 9.160036e-05 -6.000000e+00 6.760886e-05 275.20 -2.00 20.00 -2.00 500.59 0.00e+00 2.860359e-01 1.679747e-02 1.806172e-02 -6.000000e+00 4.868192e-02 223.90 -2.00 3.51 -2.00 502.16 0.00e+00 2.587 0.000 489.00 513.00 1 7.6912e+00 1.2882e-03 4.5281e-03 -6.0000e+00 3.7262e-03 3.1971e-03 3.3106e-04 3.7561e-04 -6.0000e+00 9.6363e-04 5.9277e-04 2.6458e-04 8.6859e-05 3.7305e-05 -6.0000e+00 2.5525e-04 -2.3627e-02 -3.9313e-05 10 0 0 10 0 0 99.98 19.23 0.77 -0.02363 -0.02179 28 8 1 4 0 1668.840 24.14 20.01 19.23 5.88 22.6 882.56 900000 -443 -316 -142 -217 163 444 417 453 422 204 104 -105 -226 171 -430 -112 -236 67 -31 -199 290 -4 312 98 338 130 239 61 -219 -321 -172 -348 72 445 -66 15 75 312 -89 -150 33 60 123 112 472 177 210 101 17 -385 -293 -730 -592 -437 -16 -154 -89 65 -69 130 43 391 146 274 110 140 -166 50 -63 -234 -119 -306 -7 -49 111 -234 -329 -27 -174 -24 -182 -298 -361 53 -108 -180 -25 226 -170 -94 163 151 307 -58 194 -91 13 -123 5 -295 -527 -473 -276 43 -306 -165 -219 -149 38 89 -129 11 153 302 512 380 159 205 215 100 62 176 376 9 156 169 222 118 171 435 -49 239 -201 -322 -155 182 -1 -127 334 -69 120 38 257 -39 97 -12 -163 -351 -525 -169 900000 -413 -301 -140 -219 169 444 422 460 427 204 108 -108 -229 171 -430 -112 -242 70 -31 -204 295 -4 319 101 348 134 244 62 -227 -324 -171 -350 74 446 -68 15 77 314 -89 -149 33 61 125 115 487 184 215 102 17 -395 -292 -716 -577 -431 -17 -152 -89 66 -70 131 44 396 148 277 110 139 -171 50 -63 -232 -118 -304 -7 -49 112 -236 -326 -26 -170 -23 -178 -294 -359 53 -109 -183 -26 230 -164 -91 160 149 307 -58 193 -89 13 -121 5 -281 -504 -461 -278 42 -304 -163 -213 -144 36 86 -128 11 155 309 525 392 165 211 220 100 62 173 369 9 154 167 219 117 168 426 -48 229 -190 -303 -146 174 -1 -126 334 -70 122 38 263 -40 99 -12 -162 -342 -505 -162 SQ 20240119T150816.4Z 8784.630745 194 1 25.55 2 67.04 149.87 106.46 46.12 0.00 1 0.00 1 0 15 2.384e-03 2.373e-03 9.302e-04 9.294e-04 1.428453e+03 5.290932e+01 1.058671e+02 -6.000000e+00 1.304516e+02 275.19 -2.00 20.00 -2.00 505.28 0.00e+00 1.519581e-03 2.521131e-05 8.320448e-05 -6.000000e+00 6.603046e-05 275.19 -2.00 20.00 -2.00 500.58 0.00e+00 2.858486e-01 1.831817e-02 1.718652e-02 -6.000000e+00 4.755865e-02 223.90 -2.00 3.51 -2.00 502.16 0.00e+00 2.544 0.000 489.00 513.00 1 7.2624e+00 1.4010e-03 4.3626e-03 -6.0000e+00 3.6400e-03 8.7490e-04 3.6129e-04 3.6734e-04 -6.0000e+00 9.4173e-04 9.1780e-04 1.0789e-03 9.5044e-05 3.3958e-05 -6.0000e+00 2.4932e-04 -2.1921e-02 -7.3705e-05 12 1 1 12 9 1 99.82 19.24 0.70 -0.02192 -0.01444 11 6 1 4 0 2128.470 24.14 20.00 19.24 5.97 22.8 883.96 900000 -487 -333 -92 -5 75 254 500 243 496 297 113 -1 -14 27 -237 -191 -229 234 79 -29 364 114 200 247 341 30 170 70 -243 -442 -298 -318 114 459 -140 -51 -34 264 -137 -191 -98 -79 29 176 345 -89 -80 104 244 -363 -355 -543 -640 -234 -90 8 -90 121 -35 104 276 303 147 230 149 108 -36 -66 -122 -139 -89 -234 -83 -130 -99 -254 -270 42 -312 -162 -190 -284 -271 -83 -36 -85 -114 108 -203 -289 33 185 327 -45 159 -5 -94 -106 9 -315 -398 -511 -245 131 -328 -281 -215 -147 163 128 -169 40 97 127 321 288 299 372 308 266 -15 299 411 257 106 267 228 -47 145 414 -84 55 -13 -347 -67 65 -255 -115 374 148 94 191 302 30 -72 102 -173 -204 -507 -329 900000 -464 -324 -89 -5 76 259 509 250 511 303 113 -1 -14 27 -235 -191 -230 240 81 -30 379 117 206 256 354 32 175 72 -244 -438 -296 -313 115 470 -145 -53 -35 271 -139 -195 -100 -81 30 182 358 -92 -83 106 246 -364 -351 -528 -621 -229 -90 8 -91 122 -35 106 281 309 151 234 151 109 -36 -66 -120 -136 -87 -228 -82 -130 -97 -252 -263 41 -302 -157 -185 -274 -264 -82 -36 -83 -112 106 -200 -287 33 185 330 -46 159 -5 -92 -103 8 -299 -378 -490 -239 131 -329 -280 -212 -145 160 127 -169 40 98 130 329 293 304 377 313 266 -15 297 407 255 106 267 228 -46 144 409 -83 54 -12 -334 -65 64 -252 -114 373 149 94 191 304 30 -73 102 -171 -201 -493 -320 SQ 20240119T172641.2Z 8784.726866 288 1 46.25 2 61.33 185.41 84.82 69.14 0.00 1 0.00 1 0 15 2.671e-03 2.668e-03 6.806e-04 6.799e-04 1.380486e+03 3.849461e+01 1.026798e+02 -6.000000e+00 1.461622e+02 275.19 -2.00 20.00 -2.00 505.28 0.00e+00 1.098495e-03 1.850497e-05 6.125414e-05 -6.000000e+00 7.398019e-05 275.19 -2.00 20.00 -2.00 500.59 0.00e+00 1.855804e-01 1.340869e-02 1.463915e-02 -6.000000e+00 5.327679e-02 223.90 -2.00 3.51 -2.00 502.16 0.00e+00 2.074 0.000 489.00 513.00 1 7.3850e+00 1.0277e-03 3.5078e-03 -6.0000e+00 4.0778e-03 2.3315e-03 2.6440e-04 3.3064e-04 -6.0000e+00 1.0547e-03 8.7953e-04 1.9520e-04 6.9623e-05 2.6638e-05 -6.0000e+00 2.7931e-04 -2.4390e-02 -4.4976e-05 10 0 0 10 0 0 99.94 19.19 0.76 -0.02439 -0.02304 25 7 1 4 0 1848.690 24.14 20.00 19.19 4.74 22.5 874.73 900000 -575 -541 -31 55 160 369 503 274 530 277 313 -38 -182 -31 -200 -188 -151 238 -13 -80 436 87 178 217 160 119 214 195 -228 -371 -144 -435 136 391 -40 -17 12 210 -67 -34 -79 74 -160 198 388 226 112 266 -1417 -173 -264 -582 -535 -423 -59 -84 -62 77 -60 40 113 301 109 361 172 213 -165 161 82 -195 -67 -337 -200 -32 45 -230 -111 -71 -2 -182 -140 -246 -290 -6 4 -213 -126 226 -155 -215 -42 114 262 -1 217 -78 -38 -196 18 -288 -365 -430 -119 -179 -311 -196 -215 -230 -96 127 -141 -113 46 170 445 230 511 257 277 199 204 157 529 56 190 214 144 142 126 170 -123 239 -156 -201 4 186 -139 -202 273 -30 16 126 489 -21 47 33 -5 -233 -447 -420 900000 -562 -514 -30 55 165 370 511 280 538 279 324 -39 -184 -31 -199 -189 -154 249 -14 -83 447 89 183 224 165 123 219 197 -225 -374 -143 -437 140 395 -42 -18 12 213 -68 -34 -79 74 -164 204 402 234 116 270 -1428 -176 -261 -566 -517 -415 -59 -83 -63 78 -60 41 114 305 111 365 173 210 -169 161 82 -192 -65 -333 -199 -33 46 -231 -109 -69 -2 -175 -136 -241 -286 -6 4 -216 -127 228 -150 -209 -41 114 263 -1 216 -77 -38 -193 17 -273 -347 -418 -119 -176 -311 -195 -211 -223 -93 123 -140 -113 46 174 457 238 528 266 284 201 202 154 519 56 189 212 143 140 125 167 -120 229 -148 -189 4 177 -136 -201 274 -30 17 129 500 -21 48 33 -5 -227 -430 -404 SQ 20240119T185655.3Z 8784.789529 346 1 46.46 2 66.30 208.34 68.63 82.21 0.00 1 0.00 1 0 15 2.266e-03 2.256e-03 6.326e-04 6.319e-04 1.305054e+03 3.568010e+01 9.818286e+01 -6.000000e+00 1.239628e+02 275.19 -2.00 20.00 -2.00 505.28 0.00e+00 8.489010e-04 1.716060e-05 4.742297e-05 -6.000000e+00 6.274389e-05 275.19 -2.00 20.00 -2.00 500.59 0.00e+00 2.160057e-01 1.243491e-02 1.281563e-02 -6.000000e+00 4.518554e-02 223.90 -2.00 3.51 -2.00 502.17 0.00e+00 2.470 0.000 489.00 513.00 1 7.2019e+00 9.5131e-04 3.8454e-03 -6.0000e+00 3.4585e-03 2.4370e-03 2.4551e-04 3.2904e-04 -6.0000e+00 8.9456e-04 1.0002e-03 2.0805e-04 6.4698e-05 2.2030e-05 -6.0000e+00 2.3689e-04 -2.4931e-02 -4.2371e-05 10 0 0 10 0 0 99.88 19.16 0.74 -0.02493 -0.02349 25 7 1 4 0 1857.900 24.04 20.00 19.16 4.24 22.4 870.53 900000 -498 -247 -85 -13 -15 334 350 412 364 257 202 -69 -183 -152 -167 -237 -87 116 149 42 361 186 245 209 357 202 119 163 -411 -365 -307 -396 45 327 -93 -21 60 132 -43 -180 -58 -33 13 64 347 213 61 111 -58 -233 -382 -526 -529 -248 -88 -90 -104 12 16 -54 260 248 155 88 119 183 -86 30 -137 -150 -120 -198 -153 36 -35 -153 -386 38 -72 -196 -117 -271 -226 -114 -83 -220 38 125 -119 -305 60 254 249 97 237 -108 -143 -55 34 -268 -470 -549 -192 -63 -223 -276 -265 -269 78 38 -30 23 176 230 294 375 371 296 235 189 60 92 376 114 147 320 275 136 169 280 -26 109 -3 -327 -178 122 -39 -192 108 73 -82 104 419 118 53 76 -104 -300 -458 -316 900000 -471 -238 -84 -13 -16 344 353 417 380 265 205 -70 -182 -149 -170 -234 -88 119 156 45 381 190 250 215 367 208 121 169 -418 -362 -300 -390 46 340 -95 -22 62 137 -45 -186 -60 -34 14 65 356 220 63 111 -60 -233 -372 -520 -521 -239 -87 -91 -107 12 16 -54 260 249 156 88 123 186 -86 29 -134 -145 -116 -191 -150 36 -35 -150 -375 36 -71 -193 -112 -260 -219 -111 -82 -219 38 125 -119 -307 60 251 249 98 235 -109 -142 -53 32 -260 -457 -525 -189 -64 -222 -274 -260 -270 78 38 -30 23 178 234 302 386 382 305 240 190 60 90 367 112 145 316 271 133 166 274 -25 107 -3 -317 -173 121 -37 -190 108 74 -83 105 427 122 54 77 -103 -292 -440 -303 SQ 20240119T201606.0Z 8784.844513 387 1 25.52 2 75.31 225.54 53.93 94.28 0.00 1 0.00 1 0 15 2.445e-03 2.432e-03 1.429e-04 1.428e-04 1.660913e+03 8.146606e+00 1.213835e+02 -6.000000e+00 1.337915e+02 275.19 -2.00 20.00 -2.00 505.30 0.00e+00 1.203364e-03 3.884465e-06 6.718511e-05 -6.000000e+00 6.771958e-05 275.19 -2.00 20.00 -2.00 500.68 0.00e+00 4.337679e-01 2.805568e-03 1.750714e-02 -6.000000e+00 4.877256e-02 223.91 -2.00 3.51 -2.00 502.23 0.00e+00 3.865 0.001 489.00 513.00 1 3.4808e+00 2.1457e-04 5.9142e-03 -6.0000e+00 3.7330e-03 -7.6656e-03 5.5203e-05 4.6282e-04 -6.0000e+00 9.6568e-04 3.3176e-02 3.6782e-04 1.4635e-05 2.9990e-05 -6.0000e+00 2.5568e-04 -2.2998e-02 -6.0667e-05 12 1 1 12 1 1 97.17 19.13 0.80 -0.02300 -0.02045 323 168 1 4 0 78.740 24.04 20.00 19.13 3.93 22.4 868.42 900000 -523 -356 -126 -60 76 470 491 472 464 278 201 5 -125 -153 -284 -304 -111 111 122 -1 130 242 206 324 304 186 217 153 -276 -366 -327 -359 44 354 43 -82 105 52 -120 -88 -33 -27 91 208 254 213 147 61 -15 -269 -392 -543 -651 -379 -147 -60 -99 -54 31 105 285 281 209 243 172 76 2 -2 -93 -254 -224 -315 -236 54 -11 -322 -350 -150 -130 -242 -207 -329 -293 -15 -94 -202 -83 -36 -105 -152 -46 198 244 134 180 50 -122 -104 -170 -381 -510 -499 -161 -75 -291 -273 -180 -200 -56 51 13 80 206 258 316 402 507 403 320 259 122 157 369 288 122 249 205 61 275 273 54 3 -92 -251 -36 137 -61 -126 109 124 71 136 198 95 70 13 -211 -324 -425 -372 900000 -498 -345 -122 -60 75 476 491 474 464 283 201 5 -123 -153 -283 -304 -110 112 126 -1 132 246 210 331 312 191 220 153 -279 -360 -317 -351 44 355 44 -84 108 52 -121 -90 -33 -28 92 214 263 221 151 62 -15 -269 -382 -534 -637 -365 -145 -61 -100 -55 31 106 288 285 213 246 173 76 2 -2 -91 -248 -217 -307 -232 53 -11 -319 -341 -144 -128 -238 -199 -319 -286 -14 -93 -202 -83 -36 -105 -149 -46 198 247 136 181 50 -121 -102 -162 -369 -495 -481 -160 -75 -294 -275 -179 -197 -55 51 13 81 207 262 322 412 520 413 325 259 124 158 369 290 124 252 208 61 278 274 54 3 -89 -242 -34 134 -61 -125 110 126 72 139 203 98 72 14 -211 -317 -423 -370