File name: Pandora251s1_Nainital-ARIES_20240521_L2Fit_fwvt1c3d20240101p1-8.txt File generation date: 20240824T102249.0Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c3p1-8 Local principal investigator: Manish Naja Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 251 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora251_OF_v2d20221122.txt Instrument calibration file used: Pandora251s1_CF_v3d20240101.txt Level 1 file used: Pandora251s1_Nainital-ARIES_20240521_L1_smca1c3d20240101p1-8.txt Full location name: Aryabhatta Research Institute of Observational Sciences (ARIES) Short location name: Nainital-ARIES Country of location: India Location latitude [deg]: 29.3588 Location longitude [deg]: 79.4583 Location altitude [m]: 1978 Local noon date: 20240521 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Based on session 2 OoB for fieldcal First and last pixel inside fitting window: 1614 1763 Nominal wavelengths inside fitting window [nm]: 492.0982 492.2195 492.3408 492.4621 492.5833 492.7045 492.8257 492.9469 493.0681 493.1892 493.3104 493.4315 493.5526 493.6737 493.7948 493.9158 494.0369 494.1579 494.2789 494.3999 494.5209 494.6418 494.7627 494.8837 495.0046 495.1255 495.2463 495.3672 495.4880 495.6088 495.7296 495.8504 495.9712 496.0919 496.2127 496.3334 496.4541 496.5748 496.6955 496.8161 496.9367 497.0574 497.1780 497.2985 497.4191 497.5397 497.6602 497.7807 497.9012 498.0217 498.1422 498.2626 498.3830 498.5034 498.6238 498.7442 498.8646 498.9849 499.1053 499.2256 499.3459 499.4662 499.5864 499.7067 499.8269 499.9471 500.0673 500.1875 500.3076 500.4278 500.5479 500.6680 500.7881 500.9082 501.0282 501.1483 501.2683 501.3883 501.5083 501.6283 501.7482 501.8682 501.9881 502.1080 502.2279 502.3478 502.4676 502.5874 502.7073 502.8271 502.9469 503.0666 503.1864 503.3061 503.4258 503.5455 503.6652 503.7849 503.9045 504.0242 504.1438 504.2634 504.3830 504.5025 504.6221 504.7416 504.8611 504.9806 505.1001 505.2196 505.3390 505.4584 505.5778 505.6972 505.8166 505.9360 506.0553 506.1746 506.2939 506.4132 506.5325 506.6518 506.7710 506.8902 507.0094 507.1286 507.2478 507.3669 507.4861 507.6052 507.7243 507.8434 507.9624 508.0815 508.2005 508.3195 508.4385 508.5575 508.6765 508.7954 508.9144 509.0333 509.1522 509.2711 509.3899 509.5088 509.6276 509.7464 509.8652 509.9840 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 251-400: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------