File name: Pandora227s1_NakhonPathom_20250306_L2Fit_fwvt1c3d20240531p1-8.txt
File generation date: 20250328T081449.1Z
Data description: Level 2 spectral fitting results file
Data file version: fwvt1c3p1-8
Local principal investigator: 
Network principal investigator: Alexander Cede
Instrument type: Pandora
Instrument number: 227
Spectrometer number: 1
Processing software version used: BlickP v1.8.75
Instrument operation file used: Pandora227_OF_v1d20220531.txt
Instrument calibration file used: Pandora227s1_CF_v3d20240531.txt
Level 1 file used: Pandora227s1_NakhonPathom_20250306_L1_smca1c3d20240531p1-8.txt
Full location name: Silpakorn University, Sanam Chandra palace campus (Nakhon Pathom)
Short location name: NakhonPathom
Country of location: Thailand
Location latitude [deg]: 13.8200
Location longitude [deg]: 100.0400
Location altitude [m]: 72
Local noon date: 20250306
Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method)
Data caveats: OOB session based on lab session 1
First and last pixel inside fitting window: 1617 1766
Nominal wavelengths inside fitting window [nm]: 492.0832 492.2045 492.3258 492.4471 492.5683 492.6895 492.8107 492.9319 493.0531 493.1742 493.2954 493.4165 493.5376 493.6587 493.7798 493.9008 494.0218 494.1429 494.2639 494.3848 494.5058 494.6268 494.7477 494.8686 494.9895 495.1104 495.2313 495.3521 495.4729 495.5937 495.7145 495.8353 495.9561 496.0768 496.1975 496.3183 496.4389 496.5596 496.6803 496.8009 496.9215 497.0422 497.1627 497.2833 497.4039 497.5244 497.6449 497.7654 497.8859 498.0064 498.1268 498.2473 498.3677 498.4881 498.6085 498.7288 498.8492 498.9695 499.0898 499.2101 499.3304 499.4507 499.5709 499.6911 499.8113 499.9315 500.0517 500.1719 500.2920 500.4121 500.5322 500.6523 500.7724 500.8925 501.0125 501.1325 501.2525 501.3725 501.4925 501.6124 501.7323 501.8523 501.9722 502.0920 502.2119 502.3317 502.4516 502.5714 502.6912 502.8110 502.9307 503.0505 503.1702 503.2899 503.4096 503.5292 503.6489 503.7685 503.8882 504.0078 504.1273 504.2469 504.3665 504.4860 504.6055 504.7250 504.8445 504.9639 505.0834 505.2028 505.3222 505.4416 505.5610 505.6803 505.7997 505.9190 506.0383 506.1576 506.2769 506.3961 506.5154 506.6346 506.7538 506.8730 506.9921 507.1113 507.2304 507.3495 507.4686 507.5877 507.7067 507.8258 507.9448 508.0638 508.1828 508.3018 508.4207 508.5397 508.6586 508.7775 508.8964 509.0152 509.1341 509.2529 509.3717 509.4905 509.6093 509.7281 509.8468 509.9655
---------------------------------------------------------------------------------------
Column 1: Two letter code of measurement routine
Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601)
Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement
Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.)
Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.)
Column 6: Total duration of measurement set in seconds
Column 7: Data processing type index
Column 8: Solar zenith angle for center-time of measurement in degree
Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 10: Lunar zenith angle for center-time of measurement in degree
Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise
Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used
Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon
Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used
Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4)
Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error
Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done
Column 18: rms of unweighted fitting residuals, -9=fitting not successful
Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used
Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given
Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful
Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 27: Water vapor effective temperature [K]
Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful
Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful
Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 38: Nitrogen dioxide effective temperature [K]
Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful
Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful
Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful
Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful
Column 49: Ozone effective temperature [K]
Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful
Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful
Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful
Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful
Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction
Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting
Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting
Column 57: Lower limit used for wavelength scaling [nm]
Column 58: Upper limit used for wavelength scaling [nm]
Column 59: Order of smoothing polynomial
Column 60: Smoothing polynomial coefficient, order 0
Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful
Column 65: Smoothing polynomial coefficient, order 1
Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful
Column 70: Mean value of measured data inside fitting window [same units as measurements]
Column 71: Wavelength change polynomial coefficient, order 0
Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful
Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination
Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination
Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large
Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality
Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature
Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1)
Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined
Column 85: Wavelength effective temperature [�C], 999=no effective temperature given
Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher)
Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination
Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting
Column 89: Number of bright count cycles
Column 90: Number of dark count cycles
Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions
Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions
Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal
Column 94: Integration time [ms]
Column 95: Temperature at electronics board [�C], 999=no temperature signal
Column 96: Spectrometer control temperature [�C], 999=no temperature signal
Column 97: Auxiliary spectrometer temperature [�C], 999=no temperature signal
Column 98: Temperature in head sensor [�C], 999=no temperature signal
Column 99: Humidity in head sensor [%], -9=no humidity signal
Column 100: Pressure in head sensor [hPa], -9=no pressure signal
Columns 101-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting
Columns 251-400: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given
---------------------------------------------------------------------------------------