File name: Pandora69s1_NewBrunswickNJ_20210507_L2Fit_fout2c23d20210421p1-8.txt File generation date: 20250604T175007.1Z Data description: Level 2 spectral fitting results file Data file version: fout2c23p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 69 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora69_OF_v2d20210223.txt Instrument calibration file used: Pandora69s1_CF_v23d20210421.txt Level 1 file used: Pandora69s1_NewBrunswickNJ_20210507_L1_smca1c23d20210421p1-8.txt Full location name: Rutgers NJDEP (USEPA AQS ID 34-023-0011) Short location name: NewBrunswickNJ Country of location: USA Location latitude [deg]: 40.4622 Location longitude [deg]: -74.4294 Location altitude [m]: 19 Local noon date: 20210507 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: based on s13, field cal for NewBrunswick, revisited HCHO First and last pixel inside fitting window: 259 400 Nominal wavelengths inside fitting window [nm]: 305.1248 305.2657 305.4066 305.5475 305.6883 305.8292 305.9700 306.1109 306.2517 306.3925 306.5333 306.6741 306.8148 306.9556 307.0963 307.2371 307.3778 307.5185 307.6592 307.7999 307.9406 308.0812 308.2219 308.3625 308.5032 308.6438 308.7844 308.9250 309.0656 309.2062 309.3467 309.4873 309.6278 309.7683 309.9089 310.0494 310.1898 310.3303 310.4708 310.6113 310.7517 310.8921 311.0326 311.1730 311.3134 311.4537 311.5941 311.7345 311.8748 312.0152 312.1555 312.2958 312.4361 312.5764 312.7167 312.8570 312.9972 313.1375 313.2777 313.4179 313.5581 313.6983 313.8385 313.9787 314.1189 314.2590 314.3991 314.5393 314.6794 314.8195 314.9596 315.0997 315.2397 315.3798 315.5198 315.6599 315.7999 315.9399 316.0799 316.2199 316.3598 316.4998 316.6397 316.7797 316.9196 317.0595 317.1994 317.3393 317.4792 317.6190 317.7589 317.8987 318.0386 318.1784 318.3182 318.4580 318.5978 318.7375 318.8773 319.0170 319.1568 319.2965 319.4362 319.5759 319.7156 319.8552 319.9949 320.1345 320.2742 320.4138 320.5534 320.6930 320.8326 320.9722 321.1117 321.2513 321.3908 321.5303 321.6698 321.8093 321.9488 322.0883 322.2278 322.3672 322.5067 322.6461 322.7855 322.9249 323.0643 323.2037 323.3430 323.4824 323.6217 323.7611 323.9004 324.0397 324.1790 324.3183 324.4575 324.5968 324.7360 324.8753 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Temperature at electronics board [°C], 999=no temperature signal Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Humidity in head sensor [%], -9=no humidity signal Column 99: Pressure in head sensor [hPa], -9=no pressure signal Columns 100-241: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 242-383: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210507T103139.1Z 7797.438647 99 1 50.16 2 83.27 73.45 66.75 120.17 0.00 1 0.00 1 0 25 5.500e-01 2.628e-02 4.532e-01 2.137e-02 1.150247e+00 1.359872e-02 1.200060e-02 -6.000000e+00 3.269619e-01 230.45 -2.00 3.50 -2.00 322.54 0.00e+00 -6.893719e-03 6.143698e-03 1.904632e-03 -6.000000e+00 1.436444e-02 282.97 -2.00 20.00 -2.00 322.19 0.00e+00 7.772 0.008 302.00 328.00 3 1.8057e-01 4.6852e-02 1.0064e-01 -6.0000e+00 8.2503e-01 1.7158e+00 6.1274e-02 6.3403e-02 -6.0000e+00 8.9570e-01 -2.1115e+00 6.0287e-02 3.6898e-02 -6.0000e+00 5.2706e-01 8.0485e-01 3.1284e-02 1.3366e-02 -6.0000e+00 2.2678e-01 4.9607e-05 -2.8863e-04 6.2258e-04 1.9973e-04 -6.0000e+00 1.6698e-02 -4.9855e-03 1.2052e-04 12 8 8 10 0 0 12.06 22.68 0.73 -0.00499 -0.00715 45 9 1 5 0 1114.480 25.90 19.99 22.68 13.77 6.1 948.27 900000 100727 900000 900000 -103735 6639 -41545 -83713 -142422 -32058 900000 20089 -66167 -5972 104503 -14234 2114 900000 29327 900000 5207 -76985 12726 -57984 200489 3688 -12216 -63667 -53008 900000 274100 127419 48771 184152 214426 74080 900000 49724 900000 60371 49534 11863 181389 -10313 41930 -32644 -11033 20078 18759 33235 41386 39922 10383 46074 20501 97454 22212 22926 24253 36317 31024 41319 8053 10377 48533 8695 12918 39894 20516 38394 23313 23729 152 5813 17750 3586 -10019 24826 3422 -1778 13918 15527 7974 6537 14689 -7143 -3773 9058 -2269 4519 -6769 3387 -2869 -7304 -4128 7369 -11966 1246 -663 -2959 -1372 -4364 -1368 -3300 -3281 -7032 -1998 -2323 -6240 -2050 433 -2219 -100 1916 971 1390 148 -1498 2220 -815 301 1313 2353 330 3893 4745 1044 268 358 2301 -280 1356 -279 40 -703 -592 -125 859 40 -1934 523 -556 900000 2095 900000 900000 -3726 138 -864 -2532 -8078 -667 900000 418 -2502 -147 2173 -484 64 900000 665 900000 128 -4076 289 -2850 4170 98 -346 -2648 -1904 900000 5701 2650 1107 3830 4459 1541 900000 1344 900000 2009 1779 628 3772 -624 1570 -2284 -626 873 887 1659 2152 2113 805 2700 1628 4054 1764 1690 1605 2190 2000 2664 761 1079 3937 970 1465 3771 2676 4718 3526 3544 27 857 2014 420 -1345 2891 543 -363 2895 3670 2216 1953 4277 -2688 -1398 2946 -802 1401 -2201 980 -933 -2845 -1873 3594 -8461 893 -516 -2294 -960 -2764 -766 -1909 -2010 -4720 -1386 -1818 -5923 -2210 524 -2995 -136 2554 1277 1814 203 -2178 3215 -1201 413 1681 2860 395 4380 5203 1222 362 578 4260 -605 3174 -720 112 -1938 -1683 -356 2645 120 -5407 1302 -1294 SS 20210507T104220.1Z 7797.446066 102 1 50.21 2 81.31 75.11 65.02 122.31 0.00 1 0.00 1 0 17 6.825e-01 1.433e-02 2.742e-01 5.617e-03 9.802468e-01 3.359355e-03 1.029997e-02 -6.000000e+00 4.028277e-01 230.45 -2.00 3.50 -2.00 322.29 0.00e+00 5.332118e-03 1.522211e-03 1.559162e-03 -6.000000e+00 1.592031e-02 282.97 -2.00 20.00 -2.00 321.95 0.00e+00 6.246 0.004 302.00 328.00 3 7.3577e-02 1.1416e-02 8.3107e-02 -6.0000e+00 1.0149e+00 6.6977e-01 1.8110e-02 5.5788e-02 -6.0000e+00 1.1002e+00 -9.0486e-01 2.1612e-02 3.3450e-02 -6.0000e+00 6.4516e-01 3.6368e-01 1.0195e-02 1.2067e-02 -6.0000e+00 2.7089e-01 3.2986e-04 -7.0640e-04 1.6641e-04 1.6489e-04 -6.0000e+00 1.9296e-02 -4.6740e-03 8.2925e-05 12 8 8 10 0 0 17.86 22.68 0.41 -0.00467 -0.00998 138 28 1 5 0 361.130 25.90 20.00 22.68 14.94 6.1 957.44 -194177 -93963 -234310 -68225 -239517 -240220 -250255 -215773 -225268 -244418 -157426 -210165 -63315 -133996 -84062 -152803 -38012 -82665 -56186 58898 -85560 14200 -41043 -72713 -86461 -56969 -77271 -68876 -25103 -9593 1977 13662 31377 -7428 -31845 -15919 8613 -11276 -11323 10789 15112 24055 7983 15904 20092 7625 26209 42813 13724 21987 30235 32758 26996 22053 17113 17764 20825 25198 12995 2239 11990 17150 6346 23963 14462 8709 11694 10661 9779 10935 10846 10505 9345 7041 3705 2444 -1459 908 -351 872 -1943 2438 856 -89 511 150 151 897 1320 259 1515 -1559 -1270 -2773 -2779 -1563 2069 -1530 -1313 -1250 -589 -968 -1224 -1338 -3750 -2515 -1893 -1603 -1369 -718 -1018 -1166 -314 -668 175 139 80 473 28 417 1340 1837 694 1313 1448 821 1904 515 415 234 200 536 129 80 -227 -180 284 299 -315 -209 -467 -930 -1644 -515 -3383 -374 -2982 -2990 -3614 -2600 -2916 -4016 -1293 -3349 -347 -1982 -967 -3804 -375 -1404 -769 323 -1546 93 -495 -1274 -1800 -905 -1481 -1169 -289 -116 27 202 447 -159 -820 -357 170 -321 -355 349 513 791 290 538 726 292 962 1430 608 1007 1460 1729 1667 1559 1338 1424 1628 1819 1009 191 979 1511 730 2625 1822 1179 1619 1619 1709 2151 2290 2244 1917 1343 648 393 -243 164 -78 232 -579 799 310 -35 211 65 68 403 580 109 588 -606 -507 -1259 -1498 -997 1514 -1337 -1215 -1128 -486 -710 -828 -924 -2814 -1964 -1586 -1486 -1449 -876 -1406 -1722 -467 -978 246 194 114 709 44 650 1973 2552 937 1694 1809 1009 2354 725 686 446 427 1239 322 214 -652 -533 849 895 -917 -567 -1171 -2190