File name: Pandora69s1_NewBrunswickNJ_20240228_L2Fit_fwvt1c23d20210421p1-8.txt File generation date: 20240229T051702.9Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c23p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 69 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora69_OF_v2d20210223.txt Instrument calibration file used: Pandora69s1_CF_v23d20210421.txt Level 1 file used: Pandora69s1_NewBrunswickNJ_20240228_L1_smca1c23d20210421p1-8.txt Full location name: Rutgers NJDEP (USEPA AQS ID 34-023-0011) Short location name: NewBrunswickNJ Country of location: USA Location latitude [deg]: 40.4622 Location longitude [deg]: -74.4294 Location altitude [m]: 19 Local noon date: 20240228 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: based on s13, field cal for NewBrunswick, revisited HCHO First and last pixel inside fitting window: 1681 1831 Nominal wavelengths inside fitting window [nm]: 492.0405 492.1612 492.2819 492.4027 492.5234 492.6440 492.7647 492.8854 493.0060 493.1266 493.2472 493.3678 493.4883 493.6089 493.7294 493.8499 493.9704 494.0909 494.2114 494.3318 494.4523 494.5727 494.6931 494.8134 494.9338 495.0541 495.1745 495.2948 495.4151 495.5354 495.6556 495.7759 495.8961 496.0163 496.1365 496.2567 496.3768 496.4970 496.6171 496.7372 496.8573 496.9774 497.0975 497.2175 497.3375 497.4575 497.5775 497.6975 497.8175 497.9374 498.0573 498.1772 498.2971 498.4170 498.5369 498.6567 498.7765 498.8963 499.0161 499.1359 499.2556 499.3754 499.4951 499.6148 499.7345 499.8542 499.9738 500.0934 500.2131 500.3327 500.4523 500.5718 500.6914 500.8109 500.9304 501.0499 501.1694 501.2889 501.4083 501.5278 501.6472 501.7666 501.8859 502.0053 502.1247 502.2440 502.3633 502.4826 502.6019 502.7211 502.8404 502.9596 503.0788 503.1980 503.3172 503.4363 503.5555 503.6746 503.7937 503.9128 504.0319 504.1509 504.2700 504.3890 504.5080 504.6270 504.7460 504.8649 504.9838 505.1028 505.2217 505.3405 505.4594 505.5783 505.6971 505.8159 505.9347 506.0535 506.1722 506.2910 506.4097 506.5284 506.6471 506.7658 506.8845 507.0031 507.1217 507.2403 507.3589 507.4775 507.5961 507.7146 507.8331 507.9516 508.0701 508.1886 508.3070 508.4255 508.5439 508.6623 508.7807 508.8990 509.0174 509.1357 509.2540 509.3723 509.4906 509.6089 509.7271 509.8453 509.9635 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-402: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20240228T141804.8Z 8824.595888 332 1 47.90 2 62.61 130.41 102.08 266.62 0.00 1 0.00 1 0 15 2.744e-03 2.742e-03 1.847e-03 1.836e-03 4.234742e+03 1.246612e+02 2.935892e+02 -6.000000e+00 1.607418e+02 276.40 -2.00 20.00 -2.00 505.23 0.00e+00 6.580167e-04 5.141522e-05 4.314617e-05 -6.000000e+00 7.833004e-05 276.40 -2.00 20.00 -2.00 500.15 0.00e+00 1.812751e-01 3.839617e-02 3.364896e-02 -6.000000e+00 5.640147e-02 225.53 -2.00 3.50 -2.00 501.78 0.00e+00 2.162 0.000 489.00 513.00 1 7.6803e+00 2.9558e-03 4.3043e-03 -6.0000e+00 4.3430e-03 1.3819e-02 7.3689e-04 7.9884e-04 -6.0000e+00 1.0910e-03 6.4634e-04 1.2264e-03 2.3037e-04 2.8589e-05 -6.0000e+00 3.6187e-04 1.6790e-02 -3.9824e-05 10 0 0 10 0 0 98.00 22.95 2.76 0.01679 0.02530 12 2 1 4 0 3990.590 26.00 20.01 22.95 21.23 30.4 1056.52 -339 -284 -514 46 189 145 495 350 210 -12 434 82 -99 -104 -32 93 -261 151 206 342 -28 267 -21 118 334 -194 -355 116 24 -768 -178 49 63 -221 90 -110 130 415 35 136 106 340 44 -62 80 -39 72 -7 -329 -692 -109 -385 -366 -900 -41 -382 -148 195 3 558 424 601 50 327 321 55 306 -420 132 -159 217 -115 114 -286 -198 -319 -74 -272 -516 224 -165 5 -55 -264 -356 -151 -440 20 -41 53 -88 -180 6 112 161 -44 -248 -11 -113 226 -104 -534 -299 -227 -7 -178 -205 -274 201 -19 285 -15 59 401 20 112 384 -65 16 79 464 407 204 366 505 219 176 184 82 -138 660 -432 114 -201 -125 -231 -397 295 -147 331 -173 221 -241 -128 234 -66 78 -37 -190 -302 58 -342 -287 -530 48 202 157 541 385 230 -13 466 88 -105 -109 -34 97 -276 161 223 372 -31 292 -23 129 365 -212 -388 124 26 -805 -184 51 65 -234 96 -118 139 442 38 144 112 358 47 -67 86 -42 77 -8 -343 -711 -109 -381 -359 -888 -41 -386 -151 201 4 575 438 619 51 336 329 56 307 -419 130 -155 210 -111 110 -280 -193 -311 -71 -261 -491 211 -156 5 -52 -252 -343 -146 -428 19 -40 52 -86 -177 6 111 157 -43 -236 -10 -103 203 -94 -487 -277 -215 -7 -173 -199 -263 192 -18 274 -15 58 393 19 111 380 -64 16 78 450 390 194 347 478 208 167 174 78 -130 614 -402 104 -183 -114 -211 -368 275 -139 314 -166 213 -233 -124 226 -63 74 -35 -176 -278 53 SQ 20240228T142341.7Z 8824.599788 335 1 49.75 2 61.81 131.69 103.12 267.48 0.00 1 0.00 1 0 15 2.125e-03 2.128e-03 4.226e-04 4.209e-04 3.538037e+03 2.787800e+01 2.559060e+02 -6.000000e+00 1.244582e+02 276.40 -2.00 20.00 -2.00 505.24 0.00e+00 6.000807e-04 1.179734e-05 4.035405e-05 -6.000000e+00 6.064930e-05 276.40 -2.00 20.00 -2.00 500.27 0.00e+00 1.147669e-01 8.748061e-03 2.697244e-02 -6.000000e+00 4.367111e-02 225.53 -2.00 3.50 -2.00 501.89 0.00e+00 2.106 0.000 489.00 513.00 1 5.2918e+00 6.7371e-04 3.8932e-03 -6.0000e+00 3.3627e-03 8.1476e-03 1.6790e-04 6.6282e-04 -6.0000e+00 8.4477e-04 7.1506e-03 1.3512e-03 5.3095e-05 2.9728e-05 -6.0000e+00 2.8019e-04 1.7000e-02 -4.2974e-05 10 0 0 10 0 0 99.90 22.95 2.71 0.01700 0.02637 120 25 1 4 0 414.490 26.11 19.99 22.95 21.40 30.5 1058.39 -350 -218 -69 130 65 188 394 460 499 288 318 249 134 -80 91 129 -59 -7 136 49 -81 95 80 153 107 -34 -347 -166 -208 -478 -122 -23 -192 -13 205 -74 -37 209 293 210 190 191 103 41 54 33 -167 -227 -266 -358 -474 -424 -396 -524 -184 -138 -69 -85 82 134 232 305 243 182 208 80 -92 -12 45 -155 -162 -93 -181 -282 -8 -36 -247 -289 -94 -169 -158 -86 -198 -307 -159 -68 -209 -118 -99 -40 -51 -83 161 162 66 -27 58 -150 -100 -151 -247 -365 -581 -239 -166 -322 -256 -13 -114 30 130 35 24 130 302 172 298 273 234 119 240 326 90 281 301 226 213 319 123 240 424 55 33 72 -84 -162 32 25 -191 53 58 127 87 155 2 108 112 -121 -182 -234 -219 -356 -216 -70 135 69 197 419 493 534 307 334 259 137 -84 95 135 -60 -8 145 53 -88 104 87 168 117 -38 -378 -178 -219 -495 -124 -23 -198 -14 212 -78 -39 217 302 222 201 197 107 43 57 35 -176 -236 -271 -370 -479 -420 -388 -517 -184 -141 -70 -87 84 137 238 313 250 187 212 81 -92 -12 44 -149 -160 -92 -174 -274 -7 -35 -238 -275 -92 -164 -153 -81 -188 -294 -154 -66 -205 -116 -97 -40 -50 -83 162 163 65 -27 56 -142 -92 -138 -225 -337 -549 -231 -164 -312 -248 -13 -109 29 125 34 23 129 302 173 301 275 234 119 235 316 87 270 289 218 205 307 118 229 401 52 31 67 -77 -151 30 24 -186 51 55 123 85 150 2 104 107 -114 -174 -221 -208 SQ 20240228T155544.5Z 8824.663710 394 1 49.81 2 51.41 156.11 120.17 282.38 0.00 1 0.00 1 0 15 2.015e-03 2.018e-03 7.642e-04 7.604e-04 2.887251e+03 4.969455e+01 2.129636e+02 -6.000000e+00 1.180356e+02 276.40 -2.00 20.00 -2.00 505.24 0.00e+00 4.626917e-04 2.124340e-05 3.164761e-05 -6.000000e+00 5.751866e-05 276.40 -2.00 20.00 -2.00 500.23 0.00e+00 5.069019e-02 1.578285e-02 2.168517e-02 -6.000000e+00 4.141565e-02 225.53 -2.00 3.50 -2.00 501.85 0.00e+00 1.600 0.000 489.00 513.00 1 6.3582e+00 1.2152e-03 3.0272e-03 -6.0000e+00 3.1891e-03 1.0092e-02 3.0334e-04 5.3831e-04 -6.0000e+00 8.0111e-04 2.6666e-03 1.2346e-03 9.6215e-05 2.4347e-05 -6.0000e+00 2.6572e-04 1.5943e-02 -3.4070e-05 10 0 0 10 0 0 99.99 22.96 2.70 0.01594 0.02451 61 12 1 4 0 816.390 26.11 20.00 22.96 22.80 30.6 1068.47 -219 -269 -210 14 -1 156 370 413 348 277 239 264 15 89 202 87 -132 77 130 -50 61 124 132 141 111 -169 -403 -120 -224 -421 -108 -45 -269 -51 193 -8 5 299 318 200 243 177 66 143 120 -137 -217 -279 -204 -375 -308 -426 -393 -335 -193 -265 -64 -77 38 134 307 195 209 102 180 33 50 -43 -43 -46 -198 -28 -96 -184 -49 -102 -203 -230 -95 -157 -122 20 -108 -189 17 -8 -129 -253 -4 43 -6 105 185 101 -116 -30 34 -128 -58 -50 -184 -354 -551 -305 82 -402 -284 -58 -81 58 -14 25 -87 191 176 78 120 290 54 131 157 259 65 190 528 209 142 284 107 290 543 87 33 162 -37 -78 -128 145 -172 -43 95 190 126 75 19 -46 -27 -166 -238 -200 -130 -217 -269 -215 15 -1 164 395 445 375 296 252 275 15 94 213 92 -136 81 139 -54 66 136 145 155 122 -185 -440 -129 -236 -436 -110 -46 -279 -54 207 -9 5 321 339 212 257 188 71 149 126 -144 -227 -288 -215 -387 -310 -421 -385 -330 -193 -270 -64 -78 39 136 312 199 214 104 182 33 49 -42 -42 -45 -196 -27 -92 -178 -47 -98 -195 -218 -92 -151 -114 18 -102 -180 16 -7 -125 -246 -4 42 -6 104 185 102 -116 -29 33 -121 -54 -45 -167 -326 -519 -294 80 -400 -272 -57 -80 57 -13 24 -85 188 175 78 120 289 54 129 153 248 62 181 500 199 135 270 102 273 507 81 30 147 -33 -71 -119 136 -165 -42 92 186 124 74 19 -45 -26 -158 -224 -187 -122 SQ 20240228T161051.3Z 8824.674205 406 1 49.58 2 50.35 160.74 122.90 285.11 0.00 1 0.00 1 0 15 1.988e-03 1.995e-03 3.431e-04 3.420e-04 2.710228e+03 2.201904e+01 2.019418e+02 -6.000000e+00 1.164208e+02 276.40 -2.00 20.00 -2.00 505.25 0.00e+00 5.841616e-04 9.566704e-06 3.810834e-05 -6.000000e+00 5.673315e-05 276.40 -2.00 20.00 -2.00 500.31 0.00e+00 2.244680e-02 7.063569e-03 2.058965e-02 -6.000000e+00 4.085239e-02 225.53 -2.00 3.50 -2.00 501.93 0.00e+00 1.564 0.000 489.00 513.00 1 5.0873e+00 5.4378e-04 2.9744e-03 -6.0000e+00 3.1457e-03 8.2622e-03 1.3594e-04 5.0873e-04 -6.0000e+00 7.9030e-04 9.5592e-03 1.4181e-03 4.3438e-05 2.6550e-05 -6.0000e+00 2.6209e-04 1.6444e-02 -4.4336e-05 10 0 0 10 0 0 99.67 22.97 2.76 0.01644 0.02628 89 18 1 4 0 556.900 26.11 20.01 22.97 23.38 30.6 1071.68 -150 -300 -70 179 45 112 395 392 383 270 256 280 81 2 107 126 -50 -32 159 -24 -39 108 116 118 144 -89 -317 -198 -255 -444 -166 -41 -162 22 194 29 -45 211 347 252 231 164 96 65 9 -19 -137 -335 -294 -335 -462 -393 -395 -458 -237 -137 -177 -37 18 110 200 272 235 93 150 129 -50 -22 83 -79 -197 -48 -166 -235 0 -89 -174 -247 -67 -60 -73 -43 -100 -273 -75 -137 -118 -222 -29 33 -138 -53 134 177 -66 -30 67 4 -138 -171 -271 -335 -461 -257 -139 -298 -221 -27 -53 4 48 3 -55 221 83 133 166 280 128 131 268 238 112 260 420 212 273 316 106 313 338 123 18 192 -107 -144 11 16 -124 -2 115 76 78 96 7 127 66 -112 -267 -189 -181 -148 -299 -71 187 47 119 424 425 415 290 272 293 84 2 110 129 -52 -34 166 -26 -41 115 124 127 155 -95 -339 -208 -263 -462 -170 -42 -169 23 204 31 -47 222 362 261 240 171 101 68 9 -19 -145 -353 -304 -339 -457 -392 -390 -455 -232 -137 -180 -38 19 114 207 275 237 94 151 131 -50 -22 81 -77 -191 -46 -162 -230 0 -87 -170 -238 -64 -57 -69 -41 -96 -265 -73 -135 -117 -221 -28 32 -135 -52 133 176 -65 -29 65 4 -131 -159 -251 -314 -443 -246 -136 -294 -217 -26 -52 3 47 3 -54 217 83 133 166 280 127 129 260 229 110 254 410 202 260 301 101 303 325 117 17 179 -100 -135 10 15 -119 -2 112 75 77 95 7 124 64 -107 -252 -176 -169 SQ 20240228T191500.7Z 8824.802091 518 1 8.95 2 56.28 218.06 149.23 338.04 0.00 1 0.00 1 0 15 2.047e-03 2.052e-03 4.204e-04 4.195e-04 3.047929e+03 2.710075e+01 2.248572e+02 -6.000000e+00 1.198905e+02 276.41 -2.00 20.00 -2.00 505.25 0.00e+00 4.713675e-04 1.175755e-05 3.248524e-05 -6.000000e+00 5.842331e-05 276.41 -2.00 20.00 -2.00 500.36 0.00e+00 4.596993e-02 8.653211e-03 2.301063e-02 -6.000000e+00 4.206893e-02 225.54 -2.00 3.50 -2.00 501.97 0.00e+00 1.796 0.000 489.00 513.00 1 3.9270e+00 6.6654e-04 3.3142e-03 -6.0000e+00 3.2393e-03 8.3317e-03 1.6634e-04 5.7379e-04 -6.0000e+00 8.1385e-04 2.9488e-02 1.3615e-03 5.3168e-05 2.6205e-05 -6.0000e+00 2.6989e-04 1.6218e-02 -4.3548e-05 12 1 1 12 1 1 99.86 22.97 2.75 0.01622 0.02566 50 58 1 4 0 175.320 26.11 20.00 22.97 19.37 30.5 1043.86 -173 -205 -104 140 17 134 360 396 386 353 189 266 127 -68 216 93 -41 -58 169 25 -182 35 22 178 181 -88 -323 -171 -182 -508 -127 24 -212 43 278 21 -41 186 363 179 170 222 102 86 6 58 -184 -341 -286 -329 -495 -350 -372 -379 -256 -136 -110 -93 -13 71 311 334 176 166 177 118 -9 -39 6 -49 -158 -15 -190 -251 -5 -97 -224 -213 -12 -151 -118 -61 -192 -320 -157 -33 -202 -182 -65 10 -89 43 151 229 -77 -11 76 19 -104 -162 -242 -413 -465 -211 -92 -346 -249 -115 -58 30 152 82 -65 162 171 190 131 292 91 61 369 354 128 262 330 200 245 308 53 271 365 54 -73 126 -110 -327 26 37 -12 -63 131 103 72 137 39 111 29 -86 -238 -138 -211 -173 -206 -105 143 18 141 383 417 406 375 199 276 133 -70 221 95 -42 -61 176 26 -195 37 23 187 191 -93 -340 -181 -188 -525 -129 24 -219 44 287 22 -43 193 379 186 176 231 105 90 6 61 -193 -353 -291 -333 -498 -346 -364 -372 -255 -136 -112 -94 -13 73 317 341 180 170 180 119 -9 -39 6 -47 -155 -15 -186 -246 -5 -95 -219 -209 -11 -145 -114 -59 -185 -311 -154 -33 -197 -178 -63 9 -88 42 149 226 -76 -11 73 18 -98 -154 -229 -394 -446 -204 -91 -339 -244 -112 -56 29 148 81 -65 160 170 191 132 293 91 61 365 347 124 254 321 195 239 299 51 261 349 52 -70 119 -104 -312 25 35 -11 -61 129 101 71 134 38 107 28 -83 -226 -132 -199