File name: Pandora152s1_NyAlesund_20200625_L2Fit_fwvt1c1d20190923p1-8.txt File generation date: 20250520T132133.6Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c1p1-8 Local principal investigator: Fjaeraa;Ann Mari Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 152 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora152_OF_v7d20190320.txt Instrument calibration file used: Pandora152s1_CF_v1d20190923.txt Level 1 file used: Pandora152s1_NyAlesund_20200625_L1_smca1c1d20190923p1-8.txt Full location name: Norwegian Polar Institute Sverdrup Short location name: NyAlesund Country of location: Norway Location latitude [deg]: 78.9233 Location longitude [deg]: 11.9299 Location altitude [m]: 18 Local noon date: 20200625 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1651 1801 Nominal wavelengths inside fitting window [nm]: 492.0415 492.1623 492.2831 492.4038 492.5246 492.6453 492.7660 492.8867 493.0074 493.1281 493.2487 493.3694 493.4900 493.6106 493.7312 493.8517 493.9723 494.0928 494.2133 494.3338 494.4543 494.5748 494.6952 494.8156 494.9361 495.0565 495.1768 495.2972 495.4175 495.5379 495.6582 495.7785 495.8988 496.0190 496.1393 496.2595 496.3797 496.4999 496.6201 496.7403 496.8604 496.9805 497.1006 497.2207 497.3408 497.4609 497.5809 497.7009 497.8209 497.9409 498.0609 498.1809 498.3008 498.4207 498.5406 498.6605 498.7804 498.9003 499.0201 499.1399 499.2597 499.3795 499.4993 499.6191 499.7388 499.8585 499.9782 500.0979 500.2176 500.3372 500.4569 500.5765 500.6961 500.8157 500.9352 501.0548 501.1743 501.2938 501.4133 501.5328 501.6523 501.7717 501.8912 502.0106 502.1300 502.2494 502.3687 502.4881 502.6074 502.7267 502.8460 502.9653 503.0846 503.2038 503.3230 503.4423 503.5615 503.6806 503.7998 503.9189 504.0381 504.1572 504.2763 504.3953 504.5144 504.6334 504.7525 504.8715 504.9905 505.1094 505.2284 505.3473 505.4662 505.5851 505.7040 505.8229 505.9418 506.0606 506.1794 506.2982 506.4170 506.5358 506.6545 506.7732 506.8920 507.0107 507.1293 507.2480 507.3667 507.4853 507.6039 507.7225 507.8411 507.9596 508.0782 508.1967 508.3152 508.4337 508.5522 508.6706 508.7891 508.9075 509.0259 509.1443 509.2627 509.3810 509.4994 509.6177 509.7360 509.8543 509.9726 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-252: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 253-403: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20200625T091707.0Z 7481.386887 258 1 28.02 2 57.13 147.46 72.98 92.33 0.00 1 0.00 1 0 15 3.204e-03 3.203e-03 3.318e-03 3.300e-03 3.074887e+03 1.947972e+02 2.221224e+02 -6.000000e+00 1.666806e+02 271.08 -2.00 20.00 -2.00 505.26 0.00e+00 3.132504e-04 8.706181e-05 2.421626e-05 -6.000000e+00 8.636861e-05 271.08 -2.00 20.00 -2.00 500.22 0.00e+00 1.415381e-01 6.640683e-02 2.553359e-02 -6.000000e+00 6.373253e-02 236.61 -2.00 5.51 -2.00 501.85 0.00e+00 1.836 0.000 489.00 513.00 1 8.9229e+00 5.0617e-03 3.4312e-03 -6.0000e+00 4.8591e-03 9.4534e-03 1.3189e-03 6.1898e-04 -6.0000e+00 1.2692e-03 1.9750e-04 7.5212e-04 2.9628e-04 2.8931e-05 -6.0000e+00 2.9702e-04 -9.2584e-03 3.4848e-05 10 0 0 10 0 0 -46.42 18.29 2.02 -0.00926 -0.00404 7 7 2 2 0 4000.000 14.99 18.29 16.13 21.98 21.79 8.2 1011.39 -470 -431 -597 466 -59 -386 317 -198 271 247 -410 -83 39 205 87 188 -306 138 765 497 -61 151 36 189 182 376 393 26 -353 -184 -67 -315 -480 -69 595 -190 -333 60 -102 459 -190 253 -466 261 243 443 10 361 -101 -68 -298 -184 14 -356 -645 -592 -333 321 -339 131 357 -93 119 343 176 239 -184 -475 -270 40 -170 -56 -21 -412 -552 221 304 -123 -50 91 491 229 -56 486 39 -276 219 -80 307 -309 -270 -229 834 -117 345 22 -398 -395 -568 -154 -238 469 -163 58 -504 -88 -96 -444 -359 -470 106 -335 -173 117 16 503 246 660 256 91 -167 280 181 181 -228 562 -71 73 383 446 162 -14 119 92 264 -291 143 -88 -64 316 -40 302 -157 10 167 86 -190 -307 147 -702 -726 -462 -429 -615 493 -61 -409 341 -217 294 266 -436 -87 40 207 87 189 -313 144 815 539 -66 164 39 207 200 413 430 29 -376 -189 -67 -315 -490 -72 644 -210 -366 65 -108 482 -200 267 -501 281 265 483 10 388 -107 -70 -300 -179 14 -344 -640 -607 -349 322 -342 131 356 -94 120 346 177 236 -190 -482 -270 39 -166 -55 -21 -392 -533 212 301 -120 -48 87 468 221 -55 452 37 -264 209 -77 293 -298 -261 -224 820 -117 341 21 -380 -368 -516 -136 -220 412 -149 55 -497 -87 -94 -431 -343 -450 102 -330 -173 117 16 508 251 672 261 91 -165 272 174 174 -221 544 -69 71 370 429 156 -14 111 85 240 -269 134 -85 -60 297 -38 288 -151 9 161 83 -180 -285 139 -662 -655 SQ 20200625T102100.0Z 7481.431250 289 1 28.01 2 55.90 164.98 70.24 107.67 0.00 1 0.00 1 0 15 3.583e-03 3.560e-03 3.262e-03 3.242e-03 3.075098e+03 1.904875e+02 2.161659e+02 -6.000000e+00 1.864222e+02 271.09 -2.00 20.00 -2.00 505.24 0.00e+00 3.463308e-04 8.533016e-05 2.563695e-05 -6.000000e+00 9.659337e-05 271.09 -2.00 20.00 -2.00 500.19 0.00e+00 1.112281e-01 6.505424e-02 2.668648e-02 -6.000000e+00 7.125001e-02 236.61 -2.00 5.51 -2.00 501.82 0.00e+00 1.778 0.000 489.00 513.00 1 8.9027e+00 4.9516e-03 3.4277e-03 -6.0000e+00 5.4326e-03 1.0136e-02 1.2926e-03 6.3097e-04 -6.0000e+00 1.4184e-03 2.0355e-04 5.8396e-05 2.9060e-04 3.0703e-05 -6.0000e+00 3.3216e-04 -1.1908e-02 8.0151e-05 10 0 0 10 0 0 4.55 18.28 2.13 -0.01191 -0.01150 7 7 2 2 0 4000.000 15.00 18.28 16.11 21.98 21.79 8.2 1012.27 -651 -239 -549 602 -604 656 526 -24 209 -33 -19 393 -82 -109 474 -9 -194 -169 196 -355 189 -287 292 83 152 483 -276 76 -97 -187 -356 -174 -243 239 824 -168 279 -77 136 173 -230 72 -281 -87 360 -29 614 144 -112 114 -205 41 -242 -570 -739 -188 117 -45 -23 -574 244 -269 373 285 154 -129 104 246 98 -24 -418 662 -724 504 157 -328 338 -380 -138 -331 -165 -881 330 -430 145 -471 -287 241 -61 110 -32 528 300 437 -643 -325 71 -68 -160 -198 84 -491 -266 -478 -20 -181 -86 -365 376 -146 107 -233 -608 896 -305 815 705 395 -204 -57 71 45 447 430 68 132 195 359 -371 330 334 -93 170 192 9 7 -101 -43 -98 801 79 -405 -90 628 26 -284 -228 -327 126 -891 -239 -652 -242 -544 612 -639 700 573 -27 231 -37 -21 416 -86 -112 482 -9 -201 -180 214 -395 210 -320 323 92 170 539 -309 84 -104 -195 -363 -177 -252 256 859 -179 294 -81 147 185 -247 78 -291 -91 379 -31 643 150 -115 114 -210 41 -236 -560 -745 -185 118 -46 -23 -588 247 -276 382 293 157 -130 103 239 94 -23 -396 619 -692 484 154 -321 323 -358 -129 -306 -153 -829 309 -410 139 -459 -280 234 -60 107 -31 521 301 441 -652 -322 68 -64 -147 -178 74 -443 -246 -463 -20 -182 -86 -360 363 -142 104 -233 -619 906 -299 794 691 391 -202 -55 68 45 436 420 63 124 183 336 -348 308 310 -85 161 179 9 6 -92 -40 -92 760 76 -394 -87 611 25 -278 -220 -308 116 -813 -218 SQ 20200625T112918.0Z 7481.478681 320 1 28.01 2 55.58 183.96 67.58 124.43 0.00 1 0.00 1 0 15 3.842e-03 3.825e-03 2.932e-03 2.918e-03 2.989965e+03 1.694823e+02 2.309539e+02 -6.000000e+00 1.999078e+02 271.09 -2.00 20.00 -2.00 505.23 0.00e+00 3.254060e-04 7.715691e-05 2.226373e-05 -6.000000e+00 1.035823e-04 271.09 -2.00 20.00 -2.00 500.25 0.00e+00 6.046891e-02 5.862052e-02 2.152032e-02 -6.000000e+00 7.642214e-02 236.61 -2.00 5.51 -2.00 501.86 0.00e+00 1.764 0.000 489.00 513.00 1 8.7694e+00 4.4735e-03 3.1660e-03 -6.0000e+00 5.8268e-03 1.1205e-02 1.1602e-03 5.6328e-04 -6.0000e+00 1.5217e-03 2.3404e-04 -1.7933e-04 2.6229e-04 3.3528e-05 -6.0000e+00 3.5620e-04 -8.3561e-03 3.9466e-05 11 8 0 10 0 0 -6.29 18.26 2.16 -0.00836 -0.00960 7 7 2 2 0 4000.000 14.99 18.26 16.54 21.98 21.79 8.3 1014.72 -546 -299 -381 724 -570 363 405 -69 563 -101 -499 329 240 -269 -156 3 193 -220 512 30 446 -378 46 57 504 322 267 -42 -459 -153 251 -350 -401 118 1102 -176 -308 464 -172 -543 64 61 -138 -160 19 706 131 -41 -250 272 -220 -189 -544 -840 -723 -43 -315 -93 335 168 350 -39 762 261 -255 622 180 220 -345 -229 -590 -48 -731 43 -311 182 -154 -485 -212 257 15 -4 -267 -323 -182 -56 -48 -308 237 -258 -42 647 176 325 599 147 -92 -402 31 -165 -643 -40 -946 -125 -656 282 -221 -614 207 -298 -253 539 -169 422 274 629 383 328 -54 -157 -3 688 478 -46 -68 192 732 -272 23 -320 -24 145 640 122 -67 -221 -156 32 41 1130 -266 -419 322 -42 5 0 286 -178 -421 -821 -77 -526 -291 -383 747 -612 395 448 -73 599 -107 -549 354 254 -282 -162 3 203 -238 536 32 477 -407 49 61 542 347 287 -45 -481 -155 258 -362 -401 121 1164 -190 -332 489 -180 -565 66 63 -145 -170 20 754 140 -44 -260 275 -217 -181 -514 -798 -702 -43 -324 -97 347 173 361 -41 790 272 -266 634 181 218 -340 -222 -569 -46 -710 42 -310 180 -150 -465 -201 241 14 -4 -256 -312 -177 -56 -48 -306 234 -257 -42 648 180 318 581 147 -91 -387 29 -151 -585 -37 -897 -122 -637 274 -215 -588 194 -281 -241 518 -165 415 272 624 383 330 -54 -156 -3 655 451 -43 -65 183 695 -260 22 -305 -23 136 583 110 -61 -200 -144 30 40 1086 -261 -414 317 -42 5 0 279 -171 -394 -761 -71 SQ 20200625T123320.0Z 7481.523148 351 1 28.01 2 56.27 201.69 65.57 140.52 0.00 1 0.00 1 0 15 4.586e-03 4.556e-03 2.716e-03 2.703e-03 2.466726e+03 1.553928e+02 2.013212e+02 -6.000000e+00 2.385853e+02 271.10 -2.00 20.00 -2.00 505.25 0.00e+00 5.654207e-04 7.134194e-05 3.272547e-05 -6.000000e+00 1.236317e-04 271.10 -2.00 20.00 -2.00 500.25 0.00e+00 2.070631e-01 5.431552e-02 1.666941e-02 -6.000000e+00 9.125095e-02 236.61 -2.00 5.51 -2.00 501.87 0.00e+00 1.795 0.000 489.00 513.00 1 8.6516e+00 4.1425e-03 3.0410e-03 -6.0000e+00 6.9569e-03 7.4070e-03 1.0806e-03 4.5761e-04 -6.0000e+00 1.8178e-03 2.5867e-04 2.9109e-04 2.4265e-04 2.8887e-05 -6.0000e+00 4.2516e-04 -7.8773e-03 3.2109e-06 11 8 0 10 0 0 -131.90 18.25 2.16 -0.00788 -0.00586 7 7 2 2 0 4000.000 15.00 18.25 17.65 21.98 21.69 8.3 1020.42 -1050 28 -499 1129 71 274 479 -258 462 -582 -408 212 480 -326 -73 27 -277 -7 13 395 28 -117 -114 33 271 579 416 297 -299 48 12 -622 -376 55 1115 -540 292 213 -368 -6 -209 -77 -176 234 254 200 853 -273 198 -6 -124 13 -1017 -654 -502 -302 150 -210 178 -164 275 235 65 876 49 -44 -159 -68 -846 -241 193 -234 -445 -308 479 -227 5 121 -769 -574 769 309 -723 -248 -695 -29 6 793 418 -280 -365 615 843 -705 573 35 329 -401 229 -202 -710 -277 -426 -213 -1105 278 -571 201 304 -279 -57 909 -989 383 -307 180 301 105 80 65 0 174 313 130 128 1214 429 59 -65 201 151 851 57 1 -153 -12 90 -203 184 784 669 -1076 418 285 -328 -159 -488 443 -248 -714 -679 -1034 28 -510 1179 73 288 512 -281 501 -630 -434 221 491 -331 -73 27 -283 -7 14 428 30 -127 -125 36 297 633 454 322 -318 49 12 -624 -382 57 1197 -597 318 230 -394 -6 -220 -82 -188 253 263 208 880 -282 209 -6 -125 13 -985 -632 -496 -308 156 -213 180 -165 276 237 66 882 50 -44 -156 -69 -853 -238 188 -229 -440 -309 459 -219 5 118 -745 -552 731 297 -709 -233 -663 -27 6 756 399 -269 -354 598 831 -712 568 35 314 -377 208 -190 -661 -259 -391 -203 -1098 275 -566 194 290 -267 -55 885 -997 385 -312 183 308 103 78 65 0 170 302 126 125 1173 418 57 -63 195 146 807 54 1 -140 -11 84 -197 172 738 635 -1044 401 275 -320 -154 -468 411 -226 -675 -616 SQ 20200625T134047.0Z 7481.569988 382 1 28.01 2 57.92 220.04 64.16 157.81 0.00 1 0.00 1 0 15 4.034e-03 4.034e-03 2.816e-03 2.803e-03 2.737546e+03 1.619768e+02 2.047801e+02 -6.000000e+00 2.099164e+02 271.10 -2.00 20.00 -2.00 505.25 0.00e+00 4.050604e-04 7.394280e-05 2.758434e-05 -6.000000e+00 1.087707e-04 271.10 -2.00 20.00 -2.00 500.26 0.00e+00 1.181734e-01 5.630343e-02 2.200511e-02 -6.000000e+00 8.026727e-02 236.61 -2.00 5.51 -2.00 501.88 0.00e+00 1.876 0.000 489.00 513.00 1 8.6995e+00 4.2955e-03 3.3203e-03 -6.0000e+00 6.1197e-03 1.0718e-02 1.1159e-03 5.5113e-04 -6.0000e+00 1.5987e-03 2.4581e-04 -1.8915e-04 2.5217e-04 2.8757e-05 -6.0000e+00 3.7404e-04 -9.1571e-03 2.5201e-05 11 8 0 10 0 0 -61.49 18.25 1.95 -0.00916 -0.01047 7 7 2 2 0 4000.000 15.00 18.25 17.14 21.98 21.69 8.3 1015.70 -292 -311 -958 1006 -258 465 779 -66 540 -46 -2 -230 4 -341 -622 -521 -512 -13 128 35 82 -373 -32 -259 171 811 363 164 -190 181 -191 -509 227 -48 1169 -269 78 459 -64 -488 332 328 477 -77 679 151 450 -81 -83 117 -290 -254 -551 -234 -991 -25 47 -215 -55 -97 390 422 -150 282 -166 -189 155 -119 -805 -462 347 42 10 -123 497 -274 -188 -127 -145 -38 176 -151 -679 -466 -27 -348 39 147 311 -739 -198 724 368 -275 483 104 151 -258 370 -146 -399 -608 -505 -146 -579 278 -485 -422 479 -25 -79 399 -953 543 28 159 682 467 -40 513 470 514 551 -338 150 139 415 -12 177 189 -95 120 27 -174 -316 780 -307 22 -298 778 164 -392 133 342 -313 -113 -305 -115 144 -481 -814 -282 -304 -971 1038 -277 507 821 -71 577 -48 -3 -238 4 -361 -653 -547 -517 -14 135 38 89 -404 -34 -280 186 874 391 175 -200 183 -189 -503 227 -50 1239 -293 84 487 -67 -510 344 340 500 -82 726 163 482 -87 -87 119 -288 -245 -524 -222 -970 -25 48 -226 -58 -101 404 439 -158 295 -174 -195 157 -119 -800 -452 333 41 10 -122 494 -274 -184 -122 -138 -36 166 -144 -656 -454 -27 -345 38 146 308 -705 -189 694 360 -272 472 100 143 -250 348 -135 -365 -562 -479 -137 -564 271 -474 -405 450 -23 -75 386 -947 537 28 159 684 471 -40 509 458 492 523 -324 144 134 398 -11 169 181 -91 113 25 -159 -286 706 -286 21 -289 755 161 -389 132 341 -300 -108 -301 -111 135 -447 -763 SQ 20200625T144218.0Z 7481.612708 409 1 28.01 2 60.12 236.31 63.65 173.78 0.00 1 0.00 1 0 15 3.833e-03 3.787e-03 3.259e-03 3.240e-03 3.030854e+03 1.917801e+02 2.348728e+02 -6.000000e+00 1.994435e+02 271.11 -2.00 20.00 -2.00 505.26 0.00e+00 3.723560e-04 8.550189e-05 2.625603e-05 -6.000000e+00 1.033365e-04 271.11 -2.00 20.00 -2.00 500.21 0.00e+00 1.777442e-01 6.527540e-02 2.209402e-02 -6.000000e+00 7.621830e-02 236.61 -2.00 5.51 -2.00 501.84 0.00e+00 1.999 0.000 489.00 513.00 1 8.8697e+00 4.9730e-03 3.4768e-03 -6.0000e+00 5.8115e-03 1.2029e-02 1.2976e-03 5.7788e-04 -6.0000e+00 1.5173e-03 2.0284e-04 -3.9237e-06 2.9108e-04 3.1124e-05 -6.0000e+00 3.5533e-04 -1.0297e-02 7.1191e-05 11 8 0 10 0 0 -48.51 18.25 2.34 -0.01030 -0.01032 7 7 2 2 0 4000.000 14.99 18.25 16.50 21.98 21.69 8.2 1011.27 -325 55 -134 795 -159 515 287 -233 706 -79 -1 207 -15 -238 -749 -430 -206 -259 188 -52 21 148 292 -135 113 554 -103 282 -283 32 -108 26 -401 333 712 -46 461 8 -136 -169 135 197 -175 159 428 454 361 98 -784 -386 -539 -439 -837 -487 -258 -461 -212 -122 -213 -46 355 91 -225 811 -41 147 -98 271 198 -48 -303 219 -115 -40 57 274 -197 201 -332 222 172 -1072 -376 -74 -5 -432 24 -189 -117 -114 224 148 -82 53 315 381 135 153 -8 -467 -414 -1139 -150 -623 -194 -265 -485 -654 192 -106 330 430 -121 936 390 467 238 398 -37 86 199 25 102 -293 466 54 725 258 -477 500 166 172 780 -329 -237 -238 -892 43 -636 469 -126 -530 605 237 664 390 192 -516 -279 -51 -462 -320 55 -138 797 -166 544 309 -256 767 -86 -1 217 -15 -243 -761 -436 -211 -272 202 -57 23 162 320 -148 124 609 -114 307 -302 33 -108 26 -410 351 773 -51 504 9 -145 -179 143 208 -188 172 467 472 375 106 -841 -403 -546 -431 -811 -471 -255 -473 -223 -123 -215 -46 355 92 -229 817 -41 146 -96 274 198 -47 -298 214 -114 -38 55 263 -187 195 -321 212 165 -1048 -350 -69 -4 -414 23 -182 -112 -110 216 145 -81 53 312 370 129 142 -7 -415 -364 -1018 -136 -595 -191 -263 -479 -637 183 -101 318 420 -121 932 392 472 242 406 -38 87 197 24 98 -283 450 52 701 250 -464 481 160 163 723 -303 -217 -220 -847 41 -595 440 -120 -508 576 228 637 374 182 -480 -253 -48 -416 SQ 20200625T164754.0Z 7481.699931 455 1 28.01 2 65.80 268.08 65.04 206.35 0.00 1 0.00 1 0 15 3.742e-03 3.716e-03 3.593e-03 3.574e-03 2.684945e+03 2.060541e+02 2.115837e+02 -6.000000e+00 1.946889e+02 271.12 -2.00 20.00 -2.00 505.22 0.00e+00 4.237079e-04 9.452929e-05 2.341707e-05 -6.000000e+00 1.008739e-04 271.12 -2.00 20.00 -2.00 500.23 0.00e+00 1.057148e-01 7.178964e-02 1.854418e-02 -6.000000e+00 7.441796e-02 236.62 -2.00 5.51 -2.00 501.85 0.00e+00 2.422 0.000 489.00 513.00 1 8.9399e+00 5.4770e-03 3.8482e-03 -6.0000e+00 5.6740e-03 1.5230e-02 1.4213e-03 5.1469e-04 -6.0000e+00 1.4818e-03 1.7903e-04 5.7267e-04 3.2155e-04 3.1310e-05 -6.0000e+00 3.4687e-04 -8.5935e-03 4.1071e-05 10 0 0 10 0 0 56.87 18.22 2.08 -0.00859 -0.00462 7 7 2 2 0 4000.000 15.00 18.22 16.27 21.88 21.69 8.3 1010.25 0 -832 -884 252 -287 289 250 -375 306 78 136 -51 -462 -93 275 351 -931 -113 287 972 -375 168 460 -11 73 -200 344 409 -163 -311 259 -145 -21 97 694 -1 14 111 -588 -106 321 286 488 67 102 -247 201 -81 141 -574 -5 -456 109 -472 -336 -543 -445 -301 120 652 -98 216 362 353 -493 19 150 91 -53 45 374 -86 108 -37 562 148 -57 150 -495 -104 -577 -191 -575 479 -92 174 14 113 141 -142 220 -277 706 -218 268 468 -56 -69 362 -261 -461 -529 -343 331 -803 -75 -462 -346 589 106 -97 -14 -345 -28 348 510 499 -147 238 -431 -15 216 -406 228 -818 562 376 298 64 572 243 36 -430 -661 844 162 -83 20 361 396 326 -227 39 -95 -189 98 -174 -253 -1064 32 -277 0 -814 -894 261 -307 315 277 -424 344 87 148 -55 -493 -98 284 363 -990 -122 301 1027 -402 179 490 -12 78 -216 368 433 -170 -313 267 -150 -21 100 735 -1 15 117 -617 -110 330 295 508 71 109 -266 214 -85 146 -585 -5 -437 102 -446 -325 -544 -458 -313 125 670 -102 223 377 367 -514 19 151 90 -52 43 356 -82 104 -36 554 146 -56 143 -468 -98 -545 -182 -552 459 -90 171 14 112 139 -141 219 -280 717 -214 274 468 -55 -66 338 -240 -419 -486 -324 323 -778 -73 -446 -329 576 99 -92 -14 -337 -28 344 505 497 -148 238 -428 -14 205 -385 215 -785 534 358 283 61 540 229 33 -395 -599 749 147 -76 19 344 382 318 -223 38 -94 -188 97 -170 -241 -998 30 -256