File name: Pandora152s1_NyAlesund_20250608_L2Fit_fwvt1c5d20230706p1-8.txt File generation date: 20250608T231620.7Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c5p1-8 Local principal investigator: Ann Mari Fjaeraa Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 152 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora152_OF_v9d20190320.txt Instrument calibration file used: Pandora152s1_CF_v5d20230706.txt Level 1 file used: Pandora152s1_NyAlesund_20250608_L1_smca1c5d20230706p1-8.txt Full location name: Norwegian Polar Institute Sverdrup Short location name: NyAlesund Country of location: Norway Location latitude [deg]: 78.9233 Location longitude [deg]: 11.9299 Location altitude [m]: 18 Local noon date: 20250608 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: based session 2 VP 20230706 First and last pixel inside fitting window: 1651 1801 Nominal wavelengths inside fitting window [nm]: 492.0234 492.1443 492.2651 492.3859 492.5066 492.6274 492.7482 492.8689 492.9896 493.1103 493.2310 493.3517 493.4723 493.5929 493.7136 493.8342 493.9547 494.0753 494.1958 494.3164 494.4369 494.5574 494.6779 494.7983 494.9188 495.0392 495.1596 495.2800 495.4004 495.5208 495.6411 495.7614 495.8818 496.0021 496.1223 496.2426 496.3628 496.4831 496.6033 496.7235 496.8437 496.9638 497.0840 497.2041 497.3242 497.4443 497.5644 497.6844 497.8045 497.9245 498.0445 498.1645 498.2845 498.4044 498.5244 498.6443 498.7642 498.8841 499.0040 499.1238 499.2437 499.3635 499.4833 499.6031 499.7228 499.8426 499.9623 500.0821 500.2018 500.3214 500.4411 500.5608 500.6804 500.8000 500.9196 501.0392 501.1588 501.2783 501.3979 501.5174 501.6369 501.7563 501.8758 501.9953 502.1147 502.2341 502.3535 502.4729 502.5922 502.7116 502.8309 502.9502 503.0695 503.1888 503.3080 503.4273 503.5465 503.6657 503.7849 503.9041 504.0232 504.1424 504.2615 504.3806 504.4997 504.6187 504.7378 504.8568 504.9758 505.0948 505.2138 505.3328 505.4517 505.5707 505.6896 505.8085 505.9273 506.0462 506.1650 506.2839 506.4027 506.5215 506.6402 506.7590 506.8777 506.9965 507.1152 507.2338 507.3525 507.4712 507.5898 507.7084 507.8270 507.9456 508.0642 508.1827 508.3012 508.4197 508.5382 508.6567 508.7752 508.8936 509.0120 509.1304 509.2488 509.3672 509.4856 509.6039 509.7222 509.8405 509.9588 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-252: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 253-403: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20250608T154502.2Z 9290.656276 598 1 48.88 2 63.44 253.23 109.64 104.65 0.00 1 0.00 1 0 15 2.250e-03 2.230e-03 1.149e-03 1.145e-03 1.692559e+03 6.336006e+01 1.311361e+02 -6.000000e+00 1.157341e+02 268.19 -2.00 20.00 -2.00 505.24 0.00e+00 4.555267e-04 2.999918e-05 2.538192e-05 -6.000000e+00 6.032275e-05 268.19 -2.00 20.00 -2.00 500.27 0.00e+00 2.364630e-01 2.306147e-02 1.394738e-02 -6.000000e+00 4.510621e-02 235.72 -2.00 5.51 -2.00 501.89 0.00e+00 2.224 0.000 489.00 513.00 1 7.5777e+00 1.7541e-03 3.4379e-03 -6.0000e+00 3.4310e-03 9.2360e-03 4.6258e-04 3.7834e-04 -6.0000e+00 9.0601e-04 7.1328e-04 -2.6562e-04 1.0376e-04 2.0673e-05 -6.0000e+00 2.0942e-04 -3.8817e-02 -2.6664e-05 11 1 0 11 8 0 99.93 18.29 2.05 -0.03882 -0.04066 21 5 1 2 0 2327.370 15.00 18.29 16.02 21.98 21.79 18.7 1035.56 900000 -605 -443 75 -15 -73 113 253 192 123 55 95 -25 -241 -56 -353 -494 -63 95 183 102 267 3 93 327 374 70 171 -102 -68 -166 -306 -393 53 437 93 93 261 -78 26 -127 -2 6 8 303 115 240 211 70 158 -123 -154 -487 -486 -496 -51 -298 1 123 4 166 65 135 366 178 151 64 55 -41 -75 -131 -156 -132 -223 106 -15 48 70 -313 -381 -82 -142 -16 -119 133 -58 -231 -14 -18 -115 -132 289 268 63 343 184 321 -144 -176 22 -427 -487 -225 -95 -101 -11 -192 -141 -60 -182 -104 6 -286 112 -158 380 446 491 177 291 -85 280 52 31 129 137 138 145 22 -84 121 149 21 -177 -273 93 168 23 -206 334 207 -321 98 372 13 52 -280 -23 -232 -297 -601 900000 -593 -441 76 -16 -77 121 274 209 133 59 100 -26 -249 -57 -361 -508 -65 101 196 110 287 3 100 353 404 76 184 -109 -71 -168 -307 -397 54 461 100 100 277 -83 27 -132 -2 6 8 321 122 255 223 74 163 -125 -152 -472 -469 -482 -51 -303 1 126 4 170 66 139 377 183 155 65 55 -40 -74 -127 -150 -127 -217 104 -15 47 67 -299 -361 -77 -135 -15 -114 128 -56 -226 -13 -17 -113 -129 284 266 64 344 183 314 -139 -166 21 -392 -446 -209 -90 -98 -11 -190 -138 -58 -174 -100 6 -282 111 -159 379 446 492 178 290 -83 271 50 29 124 132 133 139 21 -81 115 141 20 -164 -251 86 156 22 -197 321 201 -313 96 363 12 51 -273 -22 -218 -276 -556 SQ 20250608T154948.6Z 9290.659590 602 1 19.78 2 63.66 254.43 109.44 105.77 0.00 1 0.00 1 0 15 1.859e-03 1.842e-03 7.855e-04 7.836e-04 1.511109e+03 4.253869e+01 1.172651e+02 -6.000000e+00 9.557992e+01 268.19 -2.00 20.00 -2.00 505.25 0.00e+00 3.741807e-04 2.056490e-05 2.189022e-05 -6.000000e+00 4.981786e-05 268.19 -2.00 20.00 -2.00 500.39 0.00e+00 2.154705e-01 1.567708e-02 1.271873e-02 -6.000000e+00 3.725028e-02 235.72 -2.00 5.51 -2.00 501.98 0.00e+00 2.241 0.000 489.00 513.00 1 6.3052e+00 1.1932e-03 3.4123e-03 -6.0000e+00 2.8334e-03 1.0598e-02 3.1435e-04 3.5233e-04 -6.0000e+00 7.4819e-04 2.5479e-03 1.5046e-04 7.0896e-05 1.8722e-05 -6.0000e+00 1.7295e-04 -3.9581e-02 -2.0105e-05 12 1 1 12 1 1 98.23 18.30 2.02 -0.03958 -0.03854 16 10 1 2 0 1163.500 15.00 18.30 16.01 21.98 21.79 18.8 1035.42 900000 -529 -425 -31 -106 51 275 258 208 173 36 36 -99 -126 -72 -179 -222 -183 5 130 -78 174 138 19 165 295 146 109 -55 -111 -82 -103 -356 24 354 57 92 56 141 52 -1 56 -28 109 236 238 214 215 -59 28 -143 -274 -264 -480 -233 -251 -29 53 194 -36 84 60 198 105 264 73 -2 -37 -273 -214 -34 -172 -269 -243 -6 49 -32 -68 -176 -44 45 -158 -133 -43 -95 -20 -143 118 180 96 -138 96 145 116 220 186 127 -199 -114 -37 -141 -601 -361 -97 11 -187 -130 -133 -106 -158 -2 -30 -218 122 32 360 475 155 243 140 20 -69 141 191 228 23 186 317 220 127 175 97 -22 -32 -117 -21 289 -25 -107 31 225 -170 -75 97 51 -143 -258 -89 -135 -249 -341 900000 -511 -420 -32 -108 53 291 277 225 186 38 37 -102 -128 -72 -186 -223 -188 6 139 -81 182 144 20 173 311 153 114 -59 -115 -83 -102 -357 25 376 60 97 58 145 55 -1 59 -28 112 245 249 224 223 -60 30 -145 -270 -254 -459 -226 -251 -30 54 197 -37 85 61 201 107 268 74 -2 -38 -273 -211 -33 -167 -263 -240 -6 49 -32 -66 -170 -42 42 -151 -129 -42 -94 -20 -139 114 174 93 -134 94 145 117 223 186 125 -192 -111 -35 -132 -563 -344 -92 11 -188 -130 -131 -102 -152 -2 -29 -219 124 31 356 471 155 243 138 19 -68 138 187 223 22 184 312 216 125 172 95 -21 -30 -108 -20 272 -24 -101 30 218 -166 -74 96 50 -142 -253 -85 -131 -237 -324 SQ 20250608T155703.1Z 9290.664619 606 1 5.82 2 64.00 256.25 109.14 107.46 0.00 1 0.00 1 0 15 1.941e-03 1.931e-03 1.143e-03 1.140e-03 1.436361e+03 6.167544e+01 1.118736e+02 -6.000000e+00 9.979716e+01 268.19 -2.00 20.00 -2.00 505.24 0.00e+00 4.035529e-04 2.990186e-05 2.282737e-05 -6.000000e+00 5.201604e-05 268.19 -2.00 20.00 -2.00 500.38 0.00e+00 2.288495e-01 2.280899e-02 1.213633e-02 -6.000000e+00 3.889505e-02 235.72 -2.00 5.51 -2.00 501.98 0.00e+00 2.267 0.000 489.00 513.00 1 5.8469e+00 1.7357e-03 3.4361e-03 -6.0000e+00 2.9585e-03 9.8382e-03 4.5762e-04 3.4069e-04 -6.0000e+00 7.8126e-04 4.0089e-03 2.7784e-04 1.0364e-04 1.8130e-05 -6.0000e+00 1.8058e-04 -3.7231e-02 -3.7184e-05 12 1 1 12 1 1 61.30 18.30 2.00 -0.03723 -0.03530 7 16 1 2 0 727.030 15.00 18.30 16.08 21.98 21.79 18.8 1036.48 900000 -386 -174 -45 -187 -155 200 386 131 67 158 -23 -127 -54 -44 -261 -221 -130 -59 242 -76 180 67 -38 320 192 147 191 -143 -77 61 -246 -472 137 305 151 -20 71 25 -185 38 -48 225 93 215 200 386 275 54 -67 -75 -260 -284 -380 -410 -71 85 -18 56 28 120 67 53 160 176 37 112 -129 74 -33 -255 -150 -257 -258 -70 135 -118 -106 -274 -81 -50 -50 -277 -223 -43 205 -128 108 193 -189 -128 249 320 -49 180 296 24 -66 -118 140 -40 -449 -373 -191 -52 -93 -434 -224 99 -31 124 -21 -123 45 98 236 272 406 331 276 212 -133 27 91 -50 54 78 112 13 31 64 -34 143 62 -131 140 342 15 -185 -177 124 10 80 378 92 -140 -54 -215 -310 -249 -379 900000 -384 -172 -46 -192 -163 207 407 139 70 164 -24 -132 -56 -44 -264 -225 -135 -61 255 -81 191 71 -41 341 205 157 203 -150 -78 61 -247 -478 138 318 157 -21 75 26 -192 39 -50 233 97 222 207 400 282 56 -69 -74 -259 -276 -367 -402 -69 86 -18 58 29 123 69 54 162 177 39 114 -129 72 -32 -252 -147 -253 -250 -69 133 -116 -102 -267 -78 -48 -49 -272 -214 -42 200 -126 106 190 -187 -127 249 316 -49 180 293 24 -65 -113 134 -37 -425 -350 -185 -51 -93 -432 -219 95 -31 119 -21 -123 45 96 234 271 405 330 273 212 -132 26 88 -49 53 76 110 13 30 63 -33 135 59 -124 132 319 14 -181 -170 121 10 79 371 91 -139 -53 -207 -299 -236 -357 SQ 20250608T165032.0Z 9290.701759 639 1 48.52 2 66.54 269.52 107.01 119.90 0.00 1 0.00 1 0 15 1.858e-03 1.845e-03 4.521e-04 4.504e-04 1.516512e+03 2.461743e+01 1.181174e+02 -6.000000e+00 9.556233e+01 268.20 -2.00 20.00 -2.00 505.23 0.00e+00 4.385221e-04 1.178659e-05 2.428159e-05 -6.000000e+00 4.981132e-05 268.20 -2.00 20.00 -2.00 500.31 0.00e+00 2.685170e-01 9.008368e-03 1.262478e-02 -6.000000e+00 3.725899e-02 235.72 -2.00 5.51 -2.00 501.92 0.00e+00 2.493 0.000 489.00 513.00 1 5.8945e+00 6.8367e-04 3.7573e-03 -6.0000e+00 2.8339e-03 5.6215e-03 1.8079e-04 3.6028e-04 -6.0000e+00 7.4875e-04 3.6889e-03 5.8582e-04 4.0741e-05 1.9586e-05 -6.0000e+00 1.7295e-04 -3.5160e-02 -8.1936e-05 10 0 0 10 0 0 99.99 18.30 1.96 -0.03516 -0.03110 100 23 1 2 0 485.120 15.00 18.30 17.26 21.98 21.79 18.9 1043.25 900000 -599 -303 -162 -58 39 146 249 189 276 97 25 -102 -133 -144 -320 -276 -102 79 168 121 68 149 99 229 187 160 81 40 -88 -92 -187 -304 18 314 142 135 139 61 -93 -59 -35 94 107 176 204 182 214 77 -21 -88 -261 -329 -422 -387 -118 -22 63 -7 70 106 106 239 150 189 149 81 -37 -172 -157 -140 -194 -263 -278 7 77 -131 -103 -241 -130 -16 -116 -131 -150 68 -3 -163 -62 77 -50 3 163 263 203 170 230 164 -114 -172 -51 -312 -420 -381 -168 -61 -211 -174 -164 -66 -199 -117 -75 -24 125 173 331 355 322 247 257 194 26 -2 174 231 81 158 144 80 107 177 64 107 -105 -220 48 116 -14 -79 121 102 4 29 131 -13 -27 -124 -183 -164 -373 -426 900000 -602 -294 -163 -61 41 158 273 209 303 105 27 -108 -138 -147 -327 -284 -107 85 175 127 72 157 104 242 199 170 85 42 -94 -95 -190 -312 19 324 150 143 146 63 -96 -60 -35 97 111 184 216 192 224 79 -21 -87 -264 -325 -415 -385 -115 -22 64 -7 72 109 109 246 154 195 152 82 -37 -168 -152 -133 -184 -250 -268 6 76 -127 -99 -227 -121 -15 -109 -124 -143 65 -3 -160 -61 76 -49 3 162 265 208 174 233 163 -111 -164 -47 -285 -384 -354 -162 -61 -216 -177 -164 -65 -195 -116 -75 -23 122 171 328 353 323 248 254 189 25 -2 164 219 77 151 137 76 101 168 60 104 -101 -208 45 111 -13 -75 117 100 4 28 129 -13 -27 -123 -177 -154 -346 -394 SQ 20250608T181719.9Z 9290.762036 689 1 47.67 2 70.62 290.54 104.17 139.91 0.00 1 0.00 1 0 15 2.438e-03 2.431e-03 1.442e-03 1.436e-03 2.040008e+03 8.087094e+01 1.537350e+02 -6.000000e+00 1.253718e+02 268.22 -2.00 20.00 -2.00 505.27 0.00e+00 4.719640e-04 3.760331e-05 2.842163e-05 -6.000000e+00 6.534394e-05 268.22 -2.00 20.00 -2.00 500.32 0.00e+00 3.993716e-01 2.901098e-02 1.801617e-02 -6.000000e+00 4.886232e-02 235.73 -2.00 5.51 -2.00 501.92 0.00e+00 2.978 0.001 489.00 513.00 1 7.8138e+00 2.2107e-03 4.5569e-03 -6.0000e+00 3.7166e-03 3.3782e-03 5.7775e-04 4.8703e-04 -6.0000e+00 9.8157e-04 4.9949e-04 2.2688e-04 1.3046e-04 2.2447e-05 -6.0000e+00 2.2685e-04 -3.8982e-02 -3.3260e-05 10 0 0 10 0 0 96.77 18.30 1.93 -0.03898 -0.03741 13 3 1 2 0 3666.900 15.00 18.30 17.24 21.98 21.79 19.0 1043.08 900000 -691 -439 125 -215 60 310 155 310 117 185 -36 5 -280 -186 -313 -219 -379 -110 73 43 295 -53 167 408 341 45 38 -184 -251 149 -385 -533 -51 466 -72 260 266 -12 -223 -9 168 134 -63 319 411 388 351 289 93 -108 -55 -677 -379 -274 -31 33 -30 32 98 39 -37 105 399 141 103 30 57 -366 -225 -154 -107 -305 -293 -177 86 -29 -333 -159 -400 100 48 -184 8 71 137 -70 -34 236 -97 -175 139 153 173 132 54 134 -12 -217 -101 -352 -303 -170 -169 -216 -22 -111 -39 -27 81 -10 75 -455 181 61 362 494 389 187 183 128 -108 -83 150 174 -90 133 182 63 136 25 88 305 232 -474 -45 -76 222 -332 467 481 -184 78 150 -124 -59 -175 -347 -63 -401 -585 900000 -680 -441 130 -216 61 323 165 331 125 194 -37 5 -281 -184 -310 -218 -386 -115 78 46 317 -57 180 439 369 49 41 -195 -259 148 -380 -531 -52 491 -78 282 286 -13 -234 -10 175 140 -67 342 444 420 376 305 97 -109 -53 -652 -361 -265 -31 33 -32 34 103 41 -39 111 420 149 107 30 58 -367 -223 -150 -104 -298 -289 -177 86 -29 -327 -153 -383 95 46 -178 8 70 136 -66 -32 222 -91 -165 132 148 169 129 52 128 -11 -197 -96 -328 -282 -161 -156 -207 -22 -108 -37 -25 76 -9 72 -447 179 60 362 496 393 189 184 127 -105 -80 143 167 -87 129 176 61 130 24 84 285 213 -433 -41 -71 210 -322 456 474 -184 78 151 -125 -60 -176 -341 -60 -377 -549