File name: Pandora152s1_NyAlesund_20250725_L2Fit_ffus5c5d20230706p1-8.txt File generation date: 20250725T232900.2Z Data description: Level 2 spectral fitting results file Data file version: ffus5c5p1-8 Local principal investigator: Ann Mari Fjaeraa Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 152 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora152_OF_v9d20190320.txt Instrument calibration file used: Pandora152s1_CF_v5d20230706.txt Level 1 file used: Pandora152s1_NyAlesund_20250725_L1_smca1c5d20230706p1-8.txt Full location name: Norwegian Polar Institute Sverdrup Short location name: NyAlesund Country of location: Norway Location latitude [deg]: 78.9233 Location longitude [deg]: 11.9299 Location altitude [m]: 18 Local noon date: 20250725 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: based session 2 VP 20230706 First and last pixel inside fitting window: 354 619 Nominal wavelengths inside fitting window [nm]: 322.6213 322.7606 322.8999 323.0392 323.1784 323.3177 323.4569 323.5961 323.7353 323.8745 324.0137 324.1529 324.2921 324.4312 324.5704 324.7095 324.8486 324.9877 325.1268 325.2659 325.4050 325.5441 325.6831 325.8221 325.9612 326.1002 326.2392 326.3782 326.5171 326.6561 326.7951 326.9340 327.0729 327.2119 327.3508 327.4897 327.6285 327.7674 327.9063 328.0451 328.1840 328.3228 328.4616 328.6004 328.7392 328.8780 329.0167 329.1555 329.2942 329.4330 329.5717 329.7104 329.8491 329.9878 330.1264 330.2651 330.4037 330.5424 330.6810 330.8196 330.9582 331.0968 331.2354 331.3739 331.5125 331.6510 331.7895 331.9281 332.0666 332.2051 332.3435 332.4820 332.6205 332.7589 332.8973 333.0358 333.1742 333.3126 333.4510 333.5893 333.7277 333.8660 334.0044 334.1427 334.2810 334.4193 334.5576 334.6959 334.8342 334.9724 335.1107 335.2489 335.3871 335.5253 335.6635 335.8017 335.9399 336.0780 336.2162 336.3543 336.4924 336.6305 336.7686 336.9067 337.0448 337.1829 337.3209 337.4590 337.5970 337.7350 337.8730 338.0110 338.1490 338.2869 338.4249 338.5628 338.7008 338.8387 338.9766 339.1145 339.2524 339.3903 339.5281 339.6660 339.8038 339.9416 340.0794 340.2172 340.3550 340.4928 340.6306 340.7683 340.9060 341.0438 341.1815 341.3192 341.4569 341.5946 341.7322 341.8699 342.0075 342.1452 342.2828 342.4204 342.5580 342.6956 342.8331 342.9707 343.1082 343.2458 343.3833 343.5208 343.6583 343.7958 343.9333 344.0707 344.2082 344.3456 344.4830 344.6205 344.7579 344.8952 345.0326 345.1700 345.3073 345.4447 345.5820 345.7193 345.8566 345.9939 346.1312 346.2685 346.4057 346.5430 346.6802 346.8174 346.9546 347.0918 347.2290 347.3662 347.5033 347.6405 347.7776 347.9147 348.0518 348.1889 348.3260 348.4631 348.6001 348.7372 348.8742 349.0112 349.1483 349.2853 349.4222 349.5592 349.6962 349.8331 349.9701 350.1070 350.2439 350.3808 350.5177 350.6546 350.7914 350.9283 351.0651 351.2019 351.3388 351.4756 351.6123 351.7491 351.8859 352.0226 352.1594 352.2961 352.4328 352.5695 352.7062 352.8429 352.9796 353.1162 353.2529 353.3895 353.5261 353.6627 353.7993 353.9359 354.0724 354.2090 354.3455 354.4821 354.6186 354.7551 354.8916 355.0280 355.1645 355.3010 355.4374 355.5738 355.7103 355.8467 355.9831 356.1194 356.2558 356.3922 356.5285 356.6648 356.8011 356.9374 357.0737 357.2100 357.3463 357.4825 357.6188 357.7550 357.8912 358.0274 358.1636 358.2998 358.4360 358.5721 358.7083 358.8444 358.9805 359.1166 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Spectrometer control temperature [°C], 999=no temperature signal Column 165: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 166: Temperature in head sensor [°C], 999=no temperature signal Column 167: Temperature at electronics board 1 [°C], 999=no temperature signal Column 168: Temperature at electronics board 2 [°C], 999=no temperature signal Column 169: Humidity in head sensor [%], -9=no humidity signal Column 170: Pressure in head sensor [hPa], -9=no pressure signal Columns 171-436: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 437-702: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20250725T141246.8Z 9337.592208 503 1 49.10 2 62.67 226.89 61.78 215.10 0.00 1 0.00 1 0 33 1.220e-03 1.143e-03 1.163e-03 1.071e-03 -1.876961e-07 3.608796e-07 8.662239e-08 6.389576e-07 3.986296e-07 235.85 -2.00 5.51 -2.00 340.31 0.00e+00 -1.002072e-04 9.482546e-05 2.058382e-05 4.869377e-05 1.042918e-04 273.02 -2.00 20.00 -2.00 337.77 0.00e+00 -8.119261e-06 1.463754e-05 1.656552e-06 4.111276e-05 1.840087e-05 273.02 -2.00 20.00 -2.00 346.34 0.00e+00 4.358387e-04 4.156574e-05 2.898536e-05 1.883305e-05 5.080128e-05 273.02 -2.00 20.00 -2.00 344.89 0.00e+00 2.081760e+05 8.737102e+04 4.707641e+04 3.207658e+05 9.702105e+04 258.89 -2.00 12.36 -2.00 351.49 0.00e+00 2.760591e-01 1.388834e-03 3.267078e-03 5.530500e-03 1.309317e-03 235.85 -2.00 5.51 -2.00 330.82 0.00e+00 6.693736e-03 1.774372e-03 2.525758e-03 1.478414e-04 1.352252e-03 273.02 -2.00 20.00 -2.00 328.77 0.00e+00 2.166 0.000 319.50 362.20 4 5.0252e+00 1.3512e-03 1.5273e-02 2.3380e-03 1.6239e-03 5.1595e-02 3.4536e-04 2.5203e-03 4.1077e-04 3.8405e-04 -7.1172e-03 6.7326e-04 7.2312e-04 1.2132e-04 7.5394e-04 -7.5338e-04 3.4929e-04 7.1304e-04 2.9171e-05 3.0679e-04 8.0302e-04 5.3706e-04 4.6939e-04 8.5296e-05 5.4289e-04 1.4814e-03 -1.0037e-02 8.1868e-04 2.1840e-04 8.8743e-05 9.2349e-04 -1.8913e-04 1.4237e-05 4.1674e-06 7.9731e-07 1.6697e-05 -4.0999e-02 0.0000e+00 -3.8721e-02 8.3998e-02 1.9035e-02 4.5644e-03 9.4192e-02 12 8 8 10 0 0 99.98 18.12 0.24 -0.04100 -0.04333 24 6 1 8 0 2045.770 15.00 18.12 18.26 21.88 21.69 19.4 1022.89 76 -53 457 170 349 151 -95 67 -44 -3 148 -81 -319 -110 -255 216 25 -88 -17 -184 76 -203 -47 -138 214 38 124 -6 29 -2 -92 -180 -7 -49 111 -36 -35 218 12 -60 -10 -43 -37 17 109 106 -50 -7 19 -42 36 -18 -138 290 70 83 -373 -73 -256 74 -102 -34 63 -147 3 80 100 14 91 -19 174 -34 -83 -115 0 135 -110 -228 175 126 -87 31 -11 -24 -99 82 -103 -46 89 -162 90 47 -20 119 77 43 110 68 45 -33 -265 186 75 -142 212 182 117 101 67 49 53 -136 -40 -58 -34 -113 82 145 -193 67 -106 121 23 112 -87 9 51 -80 44 -83 38 -71 -34 -6 -76 -92 -206 -4 52 -30 210 -44 24 -124 -122 279 -24 99 -27 56 -52 -41 126 18 -55 165 150 -155 -15 -48 -136 39 85 197 -77 19 -66 -40 -148 -182 -14 -244 -154 107 -21 -101 12 121 -40 7 137 -164 -72 -5 -95 229 63 191 51 -83 -76 -218 48 16 -164 205 -5 3 -33 19 10 -92 69 -63 -43 -93 -133 -26 19 79 99 55 78 191 53 118 37 -212 -8 118 -116 -9 93 86 -185 -20 -102 55 -1 -29 166 -47 63 83 -43 257 -164 53 -103 -6 60 -109 88 -76 -29 95 -104 12 90 -247 144 -82 -103 167 -7 66 -141 58 -203 -43 -172 209 143 -57 -42 18 36 -24 204 81 177 80 -52 37 -25 -2 93 -52 -209 -72 -165 136 15 -53 -10 -118 52 -148 -36 -112 177 32 103 -5 24 -2 -79 -155 -6 -41 92 -30 -29 176 10 -47 -8 -35 -29 13 88 89 -45 -7 19 -42 36 -18 -141 297 70 81 -343 -64 -222 65 -91 -31 57 -132 3 74 96 14 87 -17 162 -32 -80 -111 0 129 -106 -218 161 112 -77 28 -10 -23 -97 83 -105 -46 87 -158 88 48 -22 129 81 42 95 54 36 -30 -256 180 69 -123 173 149 102 95 68 50 53 -131 -38 -56 -35 -119 87 156 -204 68 -106 119 23 120 -98 11 59 -92 49 -91 40 -75 -36 -6 -79 -93 -206 -4 55 -34 241 -50 26 -135 -132 308 -27 116 -31 64 -59 -46 139 19 -53 144 123 -127 -13 -46 -139 43 95 222 -88 22 -74 -45 -156 -183 -14 -255 -165 118 -24 -115 14 140 -45 8 136 -162 -73 -6 -106 253 68 208 57 -92 -82 -229 48 17 -169 210 -5 4 -38 24 12 -116 86 -77 -52 -110 -154 -29 20 86 112 65 95 228 60 123 37 -208 -8 129 -133 -11 110 103 -223 -24 -127 68 -2 -35 205 -59 79 105 -55 321 -202 63 -120 -7 70 -128 103 -92 -34 108 -112 12 84 -230 135 -79 -104 178 -8 70 -139 51 -170 -35 -135 168 117 -50 -41 19 SS 20250725T142440.1Z 9337.600465 511 1 41.27 2 63.10 230.00 62.15 218.15 0.00 1 0.00 1 0 33 1.372e-03 1.293e-03 1.318e-03 1.223e-03 -4.122765e-07 4.109244e-07 8.663336e-08 6.389753e-07 4.483750e-07 235.85 -2.00 5.51 -2.00 340.23 0.00e+00 -3.622061e-05 1.079832e-04 1.936662e-05 4.869273e-05 1.173857e-04 273.02 -2.00 20.00 -2.00 337.68 0.00e+00 -1.498310e-05 1.672458e-05 1.441217e-06 4.111255e-05 2.068087e-05 273.02 -2.00 20.00 -2.00 346.27 0.00e+00 4.191697e-04 4.744292e-05 2.943474e-05 1.883973e-05 5.714475e-05 273.02 -2.00 20.00 -2.00 344.84 0.00e+00 2.171488e+05 9.940792e+04 4.849076e+04 3.207610e+05 1.092127e+05 258.89 -2.00 12.36 -2.00 351.54 0.00e+00 2.817123e-01 1.573595e-03 3.352046e-03 5.530320e-03 1.476078e-03 235.85 -2.00 5.51 -2.00 330.73 0.00e+00 5.342580e-03 1.989466e-03 1.974242e-03 1.451543e-04 1.520952e-03 273.02 -2.00 20.00 -2.00 328.67 0.00e+00 2.198 0.000 319.50 362.20 4 5.1166e+00 1.5432e-03 1.5493e-02 2.3380e-03 1.8265e-03 5.0845e-02 3.9321e-04 2.5579e-03 4.1083e-04 4.3235e-04 -7.8832e-03 7.6741e-04 7.3603e-04 1.2023e-04 8.4948e-04 -9.6870e-04 3.9338e-04 7.0461e-04 2.9190e-05 3.4526e-04 1.0420e-03 6.0899e-04 4.6677e-04 8.4365e-05 6.1182e-04 1.3221e-03 -8.9200e-03 9.3097e-04 2.3264e-04 8.9577e-05 1.0357e-03 -1.7039e-04 1.6189e-05 4.2514e-06 7.9308e-07 1.8780e-05 -4.0992e-02 0.0000e+00 -1.3913e-01 9.5552e-02 2.0407e-02 4.5781e-03 1.0576e-01 12 9 9 12 9 1 99.10 18.12 0.17 -0.04099 -0.04309 10 3 1 8 0 3751.050 15.00 18.12 17.57 21.88 21.69 19.3 1018.16 -88 175 107 93 256 -101 139 178 61 -365 138 -291 125 0 -177 -521 -157 199 -82 142 1 -24 24 167 -43 41 -113 131 -63 -94 87 -142 146 -85 42 50 93 98 1 -208 130 261 -379 133 -101 -149 176 47 199 31 86 -107 31 25 107 -234 -164 -140 -1 3 14 164 54 -52 0 -149 -97 107 78 109 -62 119 22 -29 -104 -155 134 -78 -19 -42 124 -276 -5 177 -40 15 24 32 30 135 -106 -139 -11 -25 16 -58 422 -133 59 -201 50 100 298 56 -102 240 71 141 -100 42 -131 -19 -40 -23 167 -197 36 -29 -30 141 -105 14 37 -38 -106 -61 48 193 7 62 -190 50 -245 -159 3 163 -284 -187 106 -8 52 -34 32 -87 -32 -40 162 -29 12 75 -225 -10 -88 58 76 -70 -128 -105 -5 -196 -7 51 155 72 26 103 -110 91 -10 -166 -11 -24 9 203 -60 33 -62 25 -28 238 106 -39 56 -189 -70 -45 225 -105 121 -2 74 -22 122 67 100 130 -155 228 -168 117 35 -70 -22 -4 -26 -98 164 -47 -8 -47 100 -69 -45 -59 -32 66 85 -152 45 -31 -168 40 21 21 -36 139 -62 -2 141 -19 370 -116 -71 -73 -102 134 -163 195 -120 -5 -89 65 234 54 -298 -81 -122 -329 -103 -280 -2 -65 81 -72 183 13 125 11 -143 344 -241 170 -10 326 -131 113 -43 81 50 46 135 -56 79 102 36 -226 89 -192 83 0 -117 -336 -98 122 -51 93 1 -18 19 136 -36 35 -96 110 -53 -81 76 -123 124 -71 35 42 77 80 1 -165 104 211 -307 106 -83 -127 158 44 195 30 86 -108 32 25 107 -228 -151 -123 0 2 13 150 49 -47 0 -139 -93 104 74 102 -58 113 21 -28 -100 -148 129 -75 -18 -38 110 -247 -5 169 -39 15 25 32 30 132 -105 -142 -11 -27 16 -57 367 -107 48 -181 49 97 276 49 -85 200 63 134 -102 43 -130 -18 -38 -23 171 -207 39 -31 -31 143 -104 14 37 -40 -120 -70 56 220 8 67 -201 53 -259 -169 3 166 -285 -188 111 -9 59 -38 36 -94 -34 -44 184 -33 13 86 -252 -11 -96 61 73 -62 -107 -88 -4 -187 -7 55 172 81 30 116 -123 100 -10 -167 -11 -25 9 224 -67 37 -71 28 -32 250 105 -39 57 -203 -78 -50 244 -114 134 -2 81 -23 124 68 103 134 -163 249 -193 142 44 -87 -27 -4 -31 -114 188 -52 -9 -51 113 -82 -54 -70 -36 69 85 -150 46 -33 -193 47 25 25 -43 170 -76 -3 172 -23 452 -144 -88 -91 -127 166 -199 231 -140 -5 -103 76 274 65 -355 -92 -132 -335 -97 -263 -2 -63 82 -77 197 13 124 10 -122 280 -194 139 -9 290 -130 120 SS 20250725T143651.7Z 9337.608932 515 1 8.47 2 63.56 233.18 62.55 221.27 0.00 1 0.00 1 0 33 1.059e-03 1.033e-03 9.467e-04 8.996e-04 7.184530e-08 2.998572e-07 8.835181e-08 6.390187e-07 3.461216e-07 235.85 -2.00 5.51 -2.00 339.99 0.00e+00 9.768855e-05 7.901016e-05 1.996729e-05 4.869281e-05 9.107320e-05 273.02 -2.00 20.00 -2.00 337.42 0.00e+00 1.095351e-05 1.229486e-05 2.040717e-06 4.111195e-05 1.588255e-05 273.02 -2.00 20.00 -2.00 346.10 0.00e+00 3.411004e-04 3.488400e-05 2.574347e-05 1.885437e-05 4.411371e-05 273.02 -2.00 20.00 -2.00 344.68 0.00e+00 5.611227e+04 7.242727e+04 5.254261e+04 3.207456e+05 8.465457e+04 258.89 -2.00 12.36 -2.00 351.73 0.00e+00 2.818009e-01 1.125288e-03 3.419688e-03 5.529805e-03 1.142439e-03 235.85 -2.00 5.51 -2.00 330.39 0.00e+00 5.818051e-04 1.365258e-03 8.844499e-04 1.361948e-04 1.173004e-03 273.02 -2.00 20.00 -2.00 328.28 0.00e+00 2.233 0.000 319.50 362.20 4 3.2718e+00 1.1378e-03 1.5726e-02 2.3382e-03 1.4081e-03 3.0648e-02 2.8815e-04 2.5881e-03 4.1114e-04 3.3543e-04 -4.4170e-03 5.6172e-04 7.3376e-04 1.1752e-04 6.5876e-04 -1.0332e-03 2.7531e-04 6.8804e-04 2.9230e-05 2.6731e-04 1.0643e-03 4.3837e-04 4.7912e-04 8.2387e-05 4.7686e-04 8.1321e-03 -1.6733e-03 6.7748e-04 2.7905e-04 9.4494e-05 7.8405e-04 -1.6449e-04 1.1793e-05 4.2787e-06 7.8690e-07 1.4488e-05 -4.1290e-02 0.0000e+00 -2.9843e-01 6.9610e-02 2.4100e-02 4.7933e-03 8.1317e-02 12 9 9 12 1 1 71.68 18.12 0.17 -0.04129 -0.04332 12 17 1 8 0 650.840 15.00 18.12 17.28 21.88 21.69 19.2 1017.10 -80 -101 70 6 254 -44 82 128 -96 14 -186 -132 -57 199 -157 38 -154 251 150 116 120 9 65 -60 -126 8 10 -1 -114 54 -31 112 38 33 -170 12 -237 -172 -145 29 -132 39 190 65 141 -108 54 72 181 -35 94 4 -179 -64 -80 -47 -70 15 53 111 58 98 -69 -66 -45 145 134 -161 147 -110 -21 17 25 -96 -26 28 35 124 79 38 -97 62 -141 98 -156 -50 -13 137 130 45 18 3 -63 -18 -46 -76 203 98 164 -122 -89 56 11 -151 -71 -1 -37 -2 -112 -36 18 -66 50 28 -108 53 -128 88 -104 214 30 63 -33 141 -40 6 -43 11 101 20 -97 -15 111 103 116 87 -309 -111 38 -131 66 57 -142 -112 -12 -24 79 100 -60 -60 24 -190 215 -53 51 43 11 -119 -30 -66 32 16 96 261 -122 -103 -44 -6 32 -49 -20 91 17 98 65 -63 -177 59 117 -14 105 -189 -1 -22 -25 176 169 44 -33 -139 -51 -180 74 -165 -148 33 -183 -26 -117 154 117 -73 48 14 20 -45 35 10 42 143 120 4 12 138 31 -129 108 -163 -41 56 -198 13 -18 -35 86 -21 73 -46 55 34 52 92 17 -123 -75 16 -101 15 63 -91 157 -152 130 16 19 -24 53 -65 132 -49 22 -15 -247 217 -32 -139 -158 -42 -127 121 -76 11 215 -132 13 167 -45 -54 38 4 150 -27 51 81 -63 10 -130 -94 -41 143 -111 26 -104 168 102 82 89 7 53 -50 -108 7 9 -1 -98 47 -28 99 33 28 -146 11 -203 -144 -120 24 -109 33 158 54 118 -94 49 69 176 -35 93 4 -180 -64 -79 -46 -65 13 47 100 53 91 -63 -60 -42 135 128 -156 141 -104 -20 16 24 -93 -25 27 33 118 74 35 -87 56 -132 94 -153 -50 -13 137 127 44 18 3 -67 -19 -48 -74 182 83 140 -112 -86 55 10 -135 -61 -1 -34 -2 -113 -37 18 -64 47 28 -110 55 -134 93 -108 217 30 62 -33 149 -44 7 -49 13 111 21 -102 -16 116 108 120 88 -311 -112 40 -144 74 63 -155 -120 -13 -26 88 113 -68 -66 27 -207 232 -55 50 39 10 -104 -27 -64 33 18 105 287 -136 -114 -49 -6 33 -50 -20 95 19 107 72 -70 -201 67 129 -15 105 -189 -1 -23 -27 193 182 48 -36 -152 -55 -189 75 -169 -153 35 -193 -28 -132 182 142 -88 57 16 24 -52 40 11 45 156 135 5 14 160 34 -136 109 -163 -42 61 -225 15 -21 -41 100 -25 88 -55 66 41 62 111 21 -149 -92 19 -120 18 72 -103 178 -174 150 19 22 -27 57 -66 128 -47 21 -15 -255 233 -35 -147 -159 -40 -113 105 -65 10 190 -123 13 178 SS 20250725T144207.6Z 9337.612588 519 1 23.18 2 63.77 234.54 62.73 222.61 0.00 1 0.00 1 0 33 1.118e-03 1.062e-03 9.914e-04 9.323e-04 -7.264165e-07 3.120268e-07 1.060472e-07 6.389901e-07 3.652460e-07 235.85 -2.00 5.51 -2.00 340.11 0.00e+00 1.073190e-04 8.214256e-05 2.304603e-05 4.869305e-05 9.588340e-05 273.02 -2.00 20.00 -2.00 337.55 0.00e+00 1.483252e-05 1.273706e-05 1.883963e-06 4.111231e-05 1.678831e-05 273.02 -2.00 20.00 -2.00 346.19 0.00e+00 2.884673e-04 3.613639e-05 2.604687e-05 1.884555e-05 4.656761e-05 273.02 -2.00 20.00 -2.00 344.77 0.00e+00 1.956256e+05 7.539454e+04 5.248051e+04 3.207516e+05 8.922238e+04 258.89 -2.00 12.36 -2.00 351.66 0.00e+00 2.844634e-01 1.183714e-03 3.436075e-03 5.530093e-03 1.206388e-03 235.85 -2.00 5.51 -2.00 330.56 0.00e+00 3.039102e-03 1.464482e-03 5.589909e-04 1.400343e-04 1.238544e-03 273.02 -2.00 20.00 -2.00 328.47 0.00e+00 2.249 0.000 319.50 362.20 4 4.2212e+00 1.1777e-03 1.5839e-02 2.3381e-03 1.4847e-03 4.0416e-02 2.9959e-04 2.6097e-03 4.1100e-04 3.5337e-04 -4.6885e-03 5.8339e-04 7.5216e-04 1.1891e-04 6.9388e-04 -7.1149e-04 2.9240e-04 6.8375e-04 2.9196e-05 2.8166e-04 4.0422e-04 4.5911e-04 4.7291e-04 8.3438e-05 5.0114e-04 3.1149e-03 -2.7487e-03 7.0589e-04 2.6185e-04 9.2054e-05 8.2925e-04 -1.6105e-04 1.2267e-05 4.2751e-06 7.8890e-07 1.5296e-05 -4.1233e-02 0.0000e+00 -1.9752e-01 7.2298e-02 2.2846e-02 4.6701e-03 8.5677e-02 12 9 9 12 1 1 95.78 18.12 0.25 -0.04123 -0.04322 13 7 1 8 0 1655.590 15.00 18.12 17.26 21.88 21.69 19.3 1017.81 68 19 314 286 104 100 -41 8 39 -24 -131 -293 12 -189 -45 43 -326 -84 114 152 96 110 94 -187 24 -135 -5 13 132 -33 126 60 -264 35 -303 -49 -230 19 -109 59 235 263 37 57 57 67 -73 62 45 32 69 55 10 51 1 -6 -171 66 -55 -50 -207 -2 96 -211 92 16 19 -18 -39 291 207 263 -60 -8 -81 2 -113 -1 44 -66 60 26 95 -31 -123 -61 -30 -174 10 -76 -56 85 -109 -59 11 79 190 -14 68 -70 18 68 -59 103 99 -4 -138 -119 41 -155 151 11 195 -69 14 58 -16 -50 38 119 -22 -188 -41 -92 36 54 -45 168 86 -205 -17 -25 -82 33 111 36 -5 -257 3 36 30 -13 -10 -76 -135 72 122 24 -17 110 32 -55 62 25 33 -179 -84 -59 102 -67 -92 -20 -201 85 39 291 -70 2 16 -152 -164 18 6 153 93 17 -147 28 250 58 19 -202 42 5 -119 94 136 -101 -94 -75 127 -114 23 -166 -38 84 -91 101 42 44 155 105 138 -96 -65 34 -19 1 67 -146 -40 -108 -24 -32 -84 39 64 47 7 28 -80 27 -6 -50 -116 121 -94 -23 72 -85 150 -55 220 29 0 56 -149 -41 -10 -113 103 -43 203 11 -110 84 -41 -188 47 -153 85 138 -20 -15 -9 -33 -120 -40 -55 101 -166 137 38 133 31 -23 36 10 158 151 58 58 -25 5 24 -16 -88 -201 8 -132 -31 29 -213 -54 75 104 69 83 75 -155 20 -115 -5 11 112 -29 110 52 -227 29 -257 -42 -195 16 -89 47 190 216 30 46 47 58 -66 58 44 32 69 55 10 52 1 -6 -158 59 -48 -44 -188 -2 88 -191 84 15 18 -17 -37 272 194 249 -58 -8 -77 2 -109 -1 41 -60 54 24 89 -30 -120 -61 -30 -175 10 -74 -55 87 -116 -63 11 77 168 -11 58 -64 17 66 -55 91 84 -4 -124 -114 42 -158 151 11 185 -67 15 61 -17 -53 39 121 -22 -185 -41 -97 40 61 -52 190 95 -220 -18 -26 -86 35 116 37 -5 -259 3 39 34 -14 -11 -82 -144 79 137 27 -19 123 36 -60 68 26 32 -162 -72 -51 92 -65 -95 -21 -223 94 43 324 -78 2 17 -153 -166 19 7 167 103 19 -168 32 277 61 19 -201 43 5 -132 103 147 -110 -104 -82 138 -120 24 -170 -39 87 -97 110 48 52 190 128 166 -115 -76 39 -21 1 72 -159 -46 -126 -29 -37 -94 41 64 47 8 31 -91 32 -8 -58 -137 145 -114 -27 86 -103 182 -68 270 36 1 68 -179 -48 -11 -130 117 -50 236 13 -129 95 -45 -193 46 -147 83 136 -20 -16 -10 -35 -121 -37 -49 86 -139 117 33 122 31 -24 SS 20250725T144720.5Z 9337.616210 522 1 49.47 2 63.97 235.89 62.92 223.94 0.00 1 0.00 1 0 49 1.946e-03 1.846e-03 1.785e-03 1.620e-03 2.999930e-07 5.484621e-07 8.280354e-08 6.389057e-07 6.358395e-07 235.85 -2.00 5.51 -2.00 340.47 0.00e+00 -1.909001e-04 1.441820e-04 2.038791e-05 4.869590e-05 1.663265e-04 273.02 -2.00 20.00 -2.00 337.96 0.00e+00 1.566240e-06 2.205740e-05 1.821870e-06 4.111329e-05 2.934705e-05 273.02 -2.00 20.00 -2.00 346.47 0.00e+00 4.194339e-04 6.284099e-05 2.720210e-05 1.881918e-05 8.102643e-05 273.02 -2.00 20.00 -2.00 345.01 0.00e+00 5.014499e+04 1.329755e+05 4.888990e+04 3.207708e+05 1.547676e+05 258.89 -2.00 12.36 -2.00 351.42 0.00e+00 2.927835e-01 2.147913e-03 3.416260e-03 5.530747e-03 2.097697e-03 235.85 -2.00 5.51 -2.00 330.99 0.00e+00 1.175886e-03 2.771212e-03 5.175681e-04 1.521174e-04 2.157403e-03 273.02 -2.00 20.00 -2.00 328.96 0.00e+00 2.265 0.000 319.50 362.20 4 5.5495e+00 2.0414e-03 1.5964e-02 2.3380e-03 2.5874e-03 6.7056e-02 5.2473e-04 2.6398e-03 4.1065e-04 6.1164e-04 -1.1275e-02 1.0248e-03 7.5638e-04 1.2354e-04 1.2043e-03 -1.5431e-03 5.4161e-04 6.8991e-04 2.9148e-05 4.8976e-04 2.8217e-03 8.2430e-04 4.6333e-04 8.7148e-05 8.6697e-04 8.1844e-04 -1.1382e-02 1.2420e-03 2.1384e-04 8.6773e-05 1.4716e-03 -1.9270e-04 2.1544e-05 4.2968e-06 8.0113e-07 2.6631e-05 -4.0730e-02 0.0000e+00 -2.3922e-01 1.2711e-01 1.9189e-02 4.4954e-03 1.4943e-01 12 8 8 10 0 0 99.93 18.12 0.62 -0.04073 -0.04311 20 5 1 8 0 2473.540 15.00 18.12 17.30 21.88 21.69 19.4 1018.53 -85 -74 287 345 -416 549 -489 120 257 136 -13 343 -222 -349 -29 -38 220 -408 189 -50 198 -150 168 -120 -14 53 -196 -97 -157 326 -300 269 -108 -175 117 -206 103 117 105 -131 397 -204 -45 -62 502 -41 -46 279 -279 33 -299 21 -55 174 100 -123 0 127 41 -157 4 20 85 -266 536 -345 40 -123 -101 21 -103 349 -334 346 -137 172 -254 -31 -49 -196 -36 -121 0 -81 228 -272 75 93 -51 -145 -169 268 11 288 -128 260 -31 87 277 -58 -34 69 324 -154 232 89 353 -237 64 -107 6 -173 -147 239 -135 299 -130 315 -96 279 -127 -198 -47 -264 235 -258 217 -199 353 -257 -124 -214 -89 115 -243 102 -249 185 -218 314 -284 45 -56 -104 -151 70 48 -82 300 21 343 -142 263 -147 -210 -307 -31 -25 -203 71 -203 266 -267 231 56 128 158 -203 286 -341 77 60 -171 -220 41 -161 43 248 -52 46 -183 24 -194 184 -218 204 59 103 136 -6 113 -333 237 -104 -28 57 -27 -78 -181 82 -37 206 47 213 -331 52 20 -112 -166 -62 184 -105 32 -111 253 76 379 -62 30 -17 91 -29 105 2 -286 88 -166 40 16 46 320 -90 19 -84 59 -112 37 29 126 -192 26 -164 97 -71 -251 317 -118 45 -98 -155 -249 207 -146 -11 95 20 55 -121 -50 -52 -121 40 298 153 -72 78 -38 -31 120 155 -201 277 -256 64 141 79 -8 211 -140 -222 -18 -23 128 -233 110 -31 131 -106 126 -95 -11 44 -162 -79 -129 272 -255 228 -90 -143 95 -169 84 92 80 -99 304 -160 -35 -48 397 -34 -40 263 -274 33 -301 22 -56 179 100 -120 0 108 35 -136 4 18 76 -236 477 -319 38 -119 -96 20 -95 327 -319 332 -131 163 -242 -29 -45 -172 -31 -107 0 -76 223 -274 77 94 -50 -141 -166 275 11 314 -135 251 -26 68 220 -52 -33 66 296 -131 186 72 304 -224 65 -110 6 -166 -138 230 -138 315 -139 340 -101 283 -126 -194 -48 -285 268 -305 256 -232 398 -281 -133 -226 -94 123 -255 104 -249 185 -231 354 -329 52 -63 -114 -163 78 55 -97 351 24 388 -159 291 -156 -200 -266 -25 -20 -176 67 -207 289 -301 261 65 146 178 -225 300 -343 77 62 -185 -245 46 -185 50 290 -59 49 -181 24 -197 198 -245 228 65 113 152 -7 124 -350 237 -105 -28 58 -28 -87 -211 101 -48 262 60 266 -403 62 24 -124 -179 -69 212 -128 40 -134 286 80 373 -60 30 -19 106 -34 126 3 -350 110 -211 50 20 58 402 -114 25 -107 75 -143 46 35 148 -224 30 -194 115 -86 -305 363 -127 45 -91 -142 -233 196 -147 -11 103 21 53 -106 -41 -41 -92 31 237 132 -70 83