File name: Pandora187s1_PittsburghPA_20230926_L2Fit_ffus5c3d20220705p1-8.txt File generation date: 20240123T214813.6Z Data description: Level 2 spectral fitting results file Data file version: ffus5c3p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 187 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora187_OF_v4d20210517.txt Instrument calibration file used: Pandora187s1_CF_v3d20220705.txt Level 1 file used: Pandora187s1_PittsburghPA_20230926_L1_smca1c3d20220705p1-8.txt Full location name: Pittsburgh, PA - Lawrenceville ACHD (USEPA AQS ID 42-003-0008) Short location name: PittsburghPA Country of location: United States Location latitude [deg]: 40.4655 Location longitude [deg]: -79.9608 Location altitude [m]: 265 Local noon date: 20230926 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 318 582 Nominal wavelengths inside fitting window [nm]: 322.5415 322.6815 322.8215 322.9615 323.1014 323.2414 323.3814 323.5213 323.6612 323.8012 323.9411 324.0810 324.2209 324.3607 324.5006 324.6405 324.7803 324.9201 325.0600 325.1998 325.3396 325.4793 325.6191 325.7589 325.8986 326.0384 326.1781 326.3178 326.4575 326.5972 326.7369 326.8766 327.0162 327.1559 327.2955 327.4351 327.5748 327.7144 327.8540 327.9935 328.1331 328.2727 328.4122 328.5517 328.6913 328.8308 328.9703 329.1098 329.2492 329.3887 329.5282 329.6676 329.8070 329.9464 330.0859 330.2253 330.3646 330.5040 330.6434 330.7827 330.9221 331.0614 331.2007 331.3400 331.4793 331.6186 331.7578 331.8971 332.0364 332.1756 332.3148 332.4540 332.5932 332.7324 332.8716 333.0107 333.1499 333.2890 333.4282 333.5673 333.7064 333.8455 333.9846 334.1236 334.2627 334.4018 334.5408 334.6798 334.8188 334.9578 335.0968 335.2358 335.3748 335.5137 335.6527 335.7916 335.9305 336.0694 336.2083 336.3472 336.4861 336.6249 336.7638 336.9026 337.0415 337.1803 337.3191 337.4579 337.5966 337.7354 337.8742 338.0129 338.1516 338.2904 338.4291 338.5678 338.7064 338.8451 338.9838 339.1224 339.2611 339.3997 339.5383 339.6769 339.8155 339.9541 340.0927 340.2312 340.3698 340.5083 340.6468 340.7853 340.9238 341.0623 341.2008 341.3392 341.4777 341.6161 341.7545 341.8930 342.0314 342.1698 342.3081 342.4465 342.5849 342.7232 342.8615 342.9999 343.1382 343.2765 343.4147 343.5530 343.6913 343.8295 343.9678 344.1060 344.2442 344.3824 344.5206 344.6588 344.7969 344.9351 345.0732 345.2114 345.3495 345.4876 345.6257 345.7638 345.9018 346.0399 346.1779 346.3160 346.4540 346.5920 346.7300 346.8680 347.0060 347.1439 347.2819 347.4198 347.5578 347.6957 347.8336 347.9715 348.1094 348.2472 348.3851 348.5229 348.6608 348.7986 348.9364 349.0742 349.2120 349.3497 349.4875 349.6253 349.7630 349.9007 350.0384 350.1761 350.3138 350.4515 350.5892 350.7268 350.8645 351.0021 351.1397 351.2773 351.4149 351.5525 351.6901 351.8276 351.9652 352.1027 352.2402 352.3777 352.5152 352.6527 352.7902 352.9276 353.0651 353.2025 353.3400 353.4774 353.6148 353.7522 353.8895 354.0269 354.1643 354.3016 354.4389 354.5762 354.7135 354.8508 354.9881 355.1254 355.2626 355.3999 355.5371 355.6743 355.8115 355.9487 356.0859 356.2231 356.3603 356.4974 356.6345 356.7717 356.9088 357.0459 357.1829 357.3200 357.4571 357.5941 357.7312 357.8682 358.0052 358.1422 358.2792 358.4162 358.5531 358.6901 358.8270 358.9640 359.1009 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-434: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 435-699: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20230926T123632.9Z 8669.525380 150 1 16.53 2 74.80 105.18 145.04 298.89 0.00 1 0.00 1 0 33 1.643e-03 1.368e-03 1.855e-03 1.570e-03 7.192973e-07 5.415621e-07 7.601613e-08 3.958249e-07 5.266291e-07 227.93 -2.00 3.49 -2.00 341.92 0.00e+00 5.284645e-04 1.526243e-04 2.189975e-05 6.247866e-05 1.466614e-04 285.52 -2.00 20.00 -2.00 339.55 0.00e+00 5.169807e-05 2.079872e-05 3.380089e-06 2.607728e-05 2.441374e-05 285.52 -2.00 20.00 -2.00 347.69 0.00e+00 4.126106e-04 6.254209e-05 2.536840e-05 1.288568e-05 7.206306e-05 285.52 -2.00 20.00 -2.00 346.48 0.00e+00 1.148334e+06 1.402754e+05 5.958214e+04 2.068890e+05 1.404640e+05 266.71 -2.00 11.20 -2.00 352.52 0.00e+00 4.370779e-01 2.497406e-03 3.477404e-03 3.288701e-03 1.937267e-03 227.93 -2.00 3.49 -2.00 331.67 0.00e+00 2.640796e-03 3.813112e-03 3.574811e-03 1.284790e-04 2.170988e-03 285.52 -2.00 20.00 -2.00 329.66 0.00e+00 3.741 0.001 319.50 362.20 4 2.9609e+00 2.0929e-03 2.5664e-02 1.4871e-03 2.2179e-03 1.7851e-02 6.1663e-04 4.0078e-03 2.7004e-04 5.6286e-04 1.9016e-03 1.0837e-03 7.4808e-04 1.0402e-04 1.0678e-03 -2.3210e-04 6.4765e-04 7.7477e-04 5.7109e-05 4.4737e-04 -1.6222e-03 9.3675e-04 5.5107e-04 7.7356e-05 8.1448e-04 3.8249e-03 -4.6219e-04 1.1692e-03 2.9862e-04 6.3345e-05 1.0098e-03 -5.8494e-05 2.2225e-05 3.9404e-06 6.2288e-07 2.4970e-05 -2.1055e-02 0.0000e+00 -2.3685e-01 1.2416e-01 2.4970e-02 3.6789e-03 1.1685e-01 12 9 9 12 1 1 92.33 17.68 0.36 -0.02106 -0.02178 11 10 1 5 0 1376.450 21.06 15.00 17.68 22.72 27.3 949.09 -355 -729 117 437 318 -474 181 161 214 245 108 -45 7 -220 -266 159 -512 109 -33 324 463 -285 146 190 -50 52 -228 -288 -79 -201 -174 -8 4 108 292 405 146 -192 61 80 298 167 -237 -123 29 139 274 79 -75 125 123 -155 169 -48 40 -265 -164 202 -23 -226 255 -250 -286 -38 -326 82 0 2 -276 -147 -164 97 141 -168 -2 64 103 172 14 25 -27 -5 -38 -23 -142 326 33 -8 -30 74 108 229 -64 -112 -111 -182 -82 139 -53 -101 35 -252 -20 82 31 -223 240 40 71 -72 89 171 117 168 -156 6 150 -25 -74 92 -163 131 -132 -277 -117 -12 85 108 54 106 -121 7 227 -35 156 -91 -102 -180 11 106 14 115 -15 -73 90 -8 -39 -4 155 77 -202 429 -17 -44 16 -239 -153 147 9 -138 66 -67 86 48 141 1 120 183 -192 86 -3 116 46 -173 -162 2 19 51 49 -197 117 -111 -49 -3 -184 -162 8 -19 145 8 -56 -274 65 -148 -209 50 94 -35 -19 -181 -8 108 88 24 36 168 86 -145 6 -75 -80 40 -84 116 40 29 7 135 5 7 -219 56 139 155 -21 -41 111 -72 -42 -45 41 -80 -56 -97 14 54 -89 33 169 30 -74 -133 -44 -121 31 79 -68 288 383 58 -48 282 -79 18 80 -27 66 2 -122 3 -145 -262 222 -230 -37 -132 -261 41 161 130 -195 79 72 100 122 53 -23 4 -116 -138 84 -262 53 -16 171 246 -166 92 121 -34 36 -162 -203 -56 -146 -121 -6 3 77 205 285 102 -131 40 51 192 112 -161 -84 20 104 208 65 -62 106 106 -135 149 -42 35 -219 -134 152 -17 -171 197 -199 -228 -30 -263 68 0 2 -234 -121 -135 81 121 -146 -2 55 88 147 12 21 -22 -4 -31 -20 -129 306 30 -7 -28 68 97 215 -63 -114 -108 -167 -69 107 -42 -85 32 -234 -17 70 25 -181 200 37 68 -70 83 153 110 156 -157 6 151 -25 -73 92 -158 126 -128 -291 -125 -13 93 116 59 112 -124 7 234 -36 158 -90 -99 -180 12 116 16 127 -16 -77 95 -9 -45 -4 179 87 -224 464 -18 -46 15 -218 -133 134 9 -139 70 -76 95 55 161 2 135 197 -205 88 -3 130 51 -200 -191 2 22 60 55 -212 120 -117 -55 -3 -215 -187 9 -22 171 9 -63 -308 72 -159 -228 56 111 -42 -24 -233 -10 139 111 29 46 206 101 -170 7 -89 -102 50 -105 143 47 32 8 149 6 8 -277 71 181 197 -27 -56 149 -97 -57 -59 55 -108 -76 -133 19 71 -114 43 216 38 -97 -171 -57 -158 41 98 -77 314 409 64 -54 325 -94 22 95 -31 70 2 -117 3 -143 -270 239 -264 -46 SS 20230926T134358.7Z 8669.572207 191 1 6.34 2 62.90 118.01 154.06 323.36 0.00 1 0.00 1 0 33 1.062e-03 1.030e-03 1.406e-03 1.319e-03 2.248438e-07 4.346629e-07 5.449665e-08 3.960214e-07 3.402028e-07 227.92 -2.00 3.49 -2.00 340.21 0.00e+00 2.294111e-04 1.197880e-04 9.800194e-06 6.245172e-05 9.410008e-05 285.52 -2.00 20.00 -2.00 337.69 0.00e+00 2.460511e-05 1.810366e-05 1.403460e-06 2.607290e-05 1.604872e-05 285.52 -2.00 20.00 -2.00 346.37 0.00e+00 1.786858e-04 5.336629e-05 1.444682e-05 1.299443e-05 4.635078e-05 285.52 -2.00 20.00 -2.00 344.93 0.00e+00 2.706267e+05 1.104274e+05 3.306342e+04 2.066599e+05 8.766247e+04 266.70 -2.00 11.20 -2.00 351.88 0.00e+00 2.642390e-01 1.676664e-03 2.122889e-03 3.287747e-03 1.140894e-03 227.92 -2.00 3.49 -2.00 330.43 0.00e+00 7.266507e-04 2.478848e-03 7.297210e-04 1.271177e-04 1.389062e-03 285.52 -2.00 20.00 -2.00 328.29 0.00e+00 2.183 0.000 319.50 362.20 4 2.7606e+00 1.7970e-03 1.4967e-02 1.4862e-03 1.5231e-03 2.3417e-02 4.4827e-04 2.3405e-03 2.7003e-04 3.5243e-04 -3.8437e-04 8.4667e-04 4.1251e-04 9.2145e-05 6.7589e-04 -1.8102e-04 4.5063e-04 4.1099e-04 5.7963e-05 2.8584e-04 7.3596e-05 6.9436e-04 2.9238e-04 6.9035e-05 5.0889e-04 1.3469e-02 -1.4512e-03 1.0761e-03 1.9819e-04 7.2636e-05 8.4646e-04 5.0011e-05 1.9108e-05 2.9023e-06 6.8946e-07 1.6124e-05 -2.2722e-02 0.0000e+00 -2.6885e-01 1.1291e-01 1.5765e-02 4.3940e-03 8.9711e-02 12 9 9 12 1 1 99.84 17.67 0.40 -0.02272 -0.02210 14 33 1 5 0 422.390 21.06 15.00 17.67 24.72 27.8 963.22 -208 -166 203 94 129 -50 208 23 72 36 -95 -49 54 -50 5 -47 -71 -186 -64 205 73 -32 98 121 47 -15 -159 38 206 -141 -79 -225 -36 -8 57 68 51 -13 8 -92 42 43 115 35 180 84 204 -8 -222 -44 -33 136 -54 -102 -210 10 -127 7 148 -129 102 -191 -86 145 56 -73 -40 -41 -128 -82 -36 208 153 -63 22 105 27 20 125 35 -86 -30 -72 -116 -190 223 -39 26 5 47 25 -7 -91 -32 16 -74 -266 33 159 -110 0 45 73 60 148 -86 -38 74 99 -12 0 -39 -33 28 9 -23 39 3 -15 147 -69 51 154 24 -40 -19 -22 35 -40 1 -96 150 -55 -16 42 21 -138 5 84 -41 -38 134 115 27 239 25 27 62 -34 70 -23 175 3 -82 21 16 -137 29 -284 46 -6 -67 41 111 -11 -43 -87 -186 -60 -23 -169 -80 128 -108 -67 -24 6 -98 -70 -234 144 -83 14 50 -111 -59 -41 49 94 3 -114 -5 270 -11 -282 101 12 9 28 -39 0 245 150 -14 103 -100 76 23 -115 -82 -7 14 -51 214 55 73 -41 34 -84 39 9 -82 -133 -8 63 -118 17 64 -13 11 18 -141 -118 -3 6 157 5 39 60 -9 -59 -86 5 114 52 114 -41 145 231 -244 22 255 -174 172 -99 19 5 46 -251 31 -101 -118 54 -21 -58 -114 -87 102 49 73 -28 121 14 44 23 -60 -32 37 -35 4 -31 -48 -124 -42 134 52 -24 75 99 40 -13 -131 31 178 -117 -66 -191 -30 -7 49 59 44 -11 7 -73 33 35 94 29 149 73 179 -8 -211 -43 -32 135 -54 -103 -207 10 -118 6 125 -111 91 -174 -78 130 50 -68 -38 -39 -118 -78 -34 197 148 -58 22 102 26 19 116 31 -75 -26 -67 -113 -182 219 -39 26 4 44 24 -7 -93 -33 17 -73 -240 27 135 -98 0 44 67 54 126 -75 -34 73 99 -12 0 -36 -32 27 9 -23 40 3 -16 148 -68 50 158 26 -44 -21 -25 38 -44 1 -99 153 -57 -16 43 22 -140 5 88 -46 -42 151 126 29 255 28 30 70 -38 76 -26 191 3 -85 20 14 -121 25 -272 46 -7 -72 45 123 -12 -47 -95 -196 -63 -23 -175 -86 136 -120 -76 -28 7 -111 -74 -241 141 -83 14 54 -123 -64 -44 54 104 3 -120 -5 276 -12 -302 104 14 10 33 -48 -1 300 181 -17 117 -117 85 25 -124 -93 -8 16 -61 248 58 74 -41 35 -90 46 10 -98 -160 -9 76 -145 21 78 -16 14 23 -172 -145 -4 8 195 6 46 70 -10 -68 -102 6 137 59 126 -44 141 231 -239 22 261 -191 185 -108 19 5 42 -226 27 -88 -107 51 -22 -64 SS 20230926T134830.4Z 8669.575351 194 1 46.10 2 62.14 118.96 154.52 325.46 0.00 1 0.00 1 0 33 8.537e-04 7.684e-04 6.344e-04 5.949e-04 7.348118e-07 1.951162e-07 5.439925e-08 3.960432e-07 2.734890e-07 227.92 -2.00 3.49 -2.00 340.16 0.00e+00 1.216840e-04 5.366846e-05 1.023483e-05 6.244952e-05 7.547264e-05 285.52 -2.00 20.00 -2.00 337.59 0.00e+00 4.883660e-05 8.210334e-06 1.281585e-06 2.607295e-05 1.292609e-05 285.52 -2.00 20.00 -2.00 346.31 0.00e+00 1.622108e-04 2.413728e-05 1.407693e-05 1.298912e-05 3.725221e-05 285.52 -2.00 20.00 -2.00 344.89 0.00e+00 1.916650e+05 4.983135e+04 3.221605e+04 2.066511e+05 7.030966e+04 266.70 -2.00 11.20 -2.00 351.81 0.00e+00 2.568327e-01 7.570741e-04 2.059654e-03 3.287929e-03 9.141431e-04 227.92 -2.00 3.49 -2.00 330.44 0.00e+00 1.291349e-03 1.117583e-03 6.880889e-04 1.302298e-04 1.116568e-03 285.52 -2.00 20.00 -2.00 328.29 0.00e+00 2.129 0.000 319.50 362.20 4 3.2005e+00 8.1224e-04 1.4597e-02 1.4862e-03 1.2248e-03 2.9719e-02 2.0183e-04 2.2829e-03 2.7000e-04 2.8204e-04 -6.7341e-04 3.8139e-04 3.9993e-04 9.2676e-05 5.4208e-04 -1.4142e-04 2.0290e-04 3.9740e-04 5.7837e-05 2.2939e-04 2.1613e-04 3.1277e-04 2.8433e-04 6.9867e-05 4.0741e-04 9.0023e-03 -2.3888e-03 4.8923e-04 1.8563e-04 7.1614e-05 6.8591e-04 7.8849e-05 8.6667e-06 2.7229e-06 6.7334e-07 1.2962e-05 -2.3264e-02 0.0000e+00 -2.4664e-01 5.1245e-02 1.4995e-02 4.2457e-03 7.2473e-02 12 8 8 10 0 0 99.98 17.67 0.33 -0.02326 -0.02229 98 30 1 5 0 470.180 21.06 15.00 17.67 24.82 27.8 963.45 -17 -111 148 365 390 3 162 58 156 29 -94 -262 -103 -121 -103 -112 -79 -112 -89 49 33 -72 141 148 -79 23 -102 -32 -1 -22 39 -76 -15 -9 13 31 25 -13 -33 -29 83 3 11 73 30 7 79 7 -23 9 48 -54 16 -1 -96 -16 -243 -15 -41 -16 25 -57 -49 2 -30 -22 119 60 -43 -21 123 10 136 -70 -37 103 87 9 -25 -81 -23 65 -79 58 30 82 -13 -100 110 -22 -40 139 -3 27 -39 -84 -65 111 22 -25 43 -150 16 -10 106 -60 42 45 18 -133 30 -35 2 -15 -84 -134 152 42 -28 140 -82 -8 -11 4 -59 -9 -5 51 -19 81 3 109 41 -13 -17 -4 -94 -28 49 -27 20 68 43 12 71 62 32 24 79 19 11 162 30 -77 144 38 -196 162 -148 29 -109 -60 -26 68 -46 -23 -9 -126 -137 -11 -71 -42 53 -60 -26 60 2 -75 19 -110 0 -122 -84 -1 -87 14 124 -3 -34 52 -19 -74 21 -43 -192 -5 -54 62 37 -32 28 161 50 -80 115 5 27 -7 0 -117 6 -16 -24 99 18 99 -78 21 -34 -21 25 6 -6 55 65 -75 -39 95 -35 -82 25 -92 -34 54 -16 71 58 -11 40 20 18 -92 70 47 -17 143 -84 107 215 -163 71 89 -31 18 44 -63 -6 60 -145 -26 -110 -150 124 -107 -56 -9 -58 75 191 220 1 94 34 95 19 -59 -172 -69 -83 -70 -73 -53 -74 -59 34 23 -54 106 119 -66 20 -88 -27 -1 -19 34 -67 -13 -8 11 26 21 -10 -26 -23 65 2 9 58 25 6 72 6 -22 9 48 -55 16 -1 -97 -15 -220 -13 -36 -14 23 -50 -46 2 -28 -20 111 58 -40 -19 111 9 127 -67 -34 96 82 9 -23 -74 -20 59 -76 54 29 83 -13 -102 107 -21 -40 144 -3 28 -39 -79 -57 94 18 -23 41 -143 16 -9 88 -50 38 43 18 -139 30 -34 2 -15 -88 -138 158 44 -28 144 -82 -8 -11 4 -64 -10 -6 55 -21 87 3 112 42 -14 -18 -4 -97 -29 52 -31 22 77 47 13 77 70 35 27 87 21 13 179 33 -77 133 34 -166 142 -135 29 -114 -63 -28 75 -51 -25 -10 -133 -142 -11 -73 -45 56 -66 -29 70 2 -86 20 -114 0 -123 -90 -1 -96 16 132 -3 -37 56 -20 -77 21 -46 -204 -6 -59 71 44 -39 34 194 60 -98 136 6 29 -8 0 -131 7 -18 -28 113 20 100 -77 22 -38 -24 29 6 -8 65 80 -95 -47 114 -43 -99 31 -114 -43 68 -19 86 69 -13 47 24 22 -107 82 55 -20 154 -88 109 212 -156 70 94 -33 19 47 -65 -5 53 -130 -22 -94 -134 115 -108 -61 SS 20230926T135734.3Z 8669.581646 200 1 45.91 2 60.65 120.91 155.36 329.86 0.00 1 0.00 1 0 33 8.465e-04 7.648e-04 5.565e-04 5.222e-04 9.775606e-07 1.716273e-07 5.410041e-08 3.960348e-07 2.712136e-07 227.92 -2.00 3.49 -2.00 340.17 0.00e+00 6.590193e-05 4.730396e-05 1.031280e-05 6.245296e-05 7.477351e-05 285.51 -2.00 20.00 -2.00 337.67 0.00e+00 7.954428e-05 7.234388e-06 1.218286e-06 2.607262e-05 1.283463e-05 285.51 -2.00 20.00 -2.00 346.29 0.00e+00 1.330607e-04 2.111830e-05 1.306678e-05 1.299875e-05 3.693338e-05 285.51 -2.00 20.00 -2.00 344.84 0.00e+00 4.894658e+04 4.374723e+04 2.994632e+04 2.066410e+05 6.963204e+04 266.70 -2.00 11.20 -2.00 351.80 0.00e+00 2.471434e-01 6.552279e-04 1.977662e-03 3.287953e-03 9.028468e-04 227.92 -2.00 3.49 -2.00 330.43 0.00e+00 1.413245e-03 9.813590e-04 6.317544e-04 1.278382e-04 1.107384e-03 285.51 -2.00 20.00 -2.00 328.28 0.00e+00 2.031 0.000 319.50 362.20 4 2.9891e+00 7.1187e-04 1.3924e-02 1.4861e-03 1.2180e-03 2.5453e-02 1.7569e-04 2.1788e-03 2.7007e-04 2.7926e-04 -1.4533e-03 3.3390e-04 3.9263e-04 9.2002e-05 5.3702e-04 -3.2422e-04 1.7901e-04 3.8359e-04 5.8130e-05 2.2728e-04 8.7213e-04 2.7427e-04 2.6840e-04 6.8336e-05 4.0323e-04 1.1939e-02 -4.8903e-03 4.2978e-04 1.8218e-04 7.3008e-05 6.8726e-04 7.6982e-05 7.6168e-06 2.7303e-06 6.8703e-07 1.2853e-05 -2.3309e-02 0.0000e+00 -1.8938e-01 4.5125e-02 1.4257e-02 4.4070e-03 7.2469e-02 12 8 8 10 0 0 99.96 17.68 0.34 -0.02331 -0.02236 147 45 1 5 0 312.260 21.06 15.00 17.68 25.17 27.9 965.89 53 -63 214 401 246 51 154 195 50 77 -102 -261 -159 -193 -142 -71 -93 -181 80 46 107 -65 16 117 -49 6 -98 -69 114 36 44 -31 -46 -25 1 -46 -20 -67 -6 20 89 79 -17 48 64 104 70 20 -74 51 -18 37 84 -81 -88 -61 -252 17 6 -113 28 -74 -163 -9 -26 10 26 -49 -14 21 90 13 101 -31 9 41 85 127 -1 -40 -3 12 -34 8 -35 53 88 -86 -39 30 -21 89 -12 -16 21 -38 -7 4 105 -19 50 -12 -14 75 136 -55 46 -5 -24 -109 51 71 13 54 -119 -173 107 -17 -65 102 -22 0 65 -38 -66 -15 35 109 25 59 -51 46 11 -54 32 72 -114 -59 31 -70 -36 18 37 35 92 94 64 101 56 12 21 170 51 -164 86 50 -143 55 -71 -45 -33 -89 -3 51 16 -6 -26 -122 -118 -19 -44 -117 10 -31 -96 76 -89 -55 -15 -91 -17 -129 -41 -1 -172 -29 99 20 20 12 22 -54 110 -54 -197 29 -90 -11 52 73 40 194 71 -52 89 46 -10 -21 -4 -94 5 -4 49 80 -16 32 -22 -27 -3 -42 -29 30 -1 42 63 -58 -38 32 -18 -55 80 -45 10 46 45 47 -31 23 -34 -22 -35 -80 138 21 -9 129 -128 31 120 -153 3 158 -22 36 44 -8 3 54 -149 -8 -65 -190 92 -71 -36 29 -33 107 207 136 30 87 112 30 48 -68 -180 -112 -139 -101 -49 -61 -117 52 31 79 -48 13 99 -40 5 -82 -57 93 30 38 -27 -38 -20 1 -37 -17 -57 -5 17 72 66 -14 40 54 92 61 19 -70 49 -18 36 84 -81 -86 -57 -236 15 5 -98 25 -68 -149 -8 -24 10 25 -48 -13 20 84 13 98 -30 9 40 83 122 -1 -35 -3 10 -32 8 -35 51 87 -84 -39 30 -22 89 -12 -17 21 -37 -6 3 89 -17 48 -12 -13 67 116 -48 40 -5 -23 -109 49 70 12 54 -121 -182 113 -18 -68 101 -21 0 66 -42 -72 -18 40 122 26 64 -55 48 11 -57 34 72 -113 -59 33 -77 -40 20 39 38 101 101 72 115 63 13 23 180 56 -167 81 43 -125 47 -66 -44 -36 -96 -3 58 19 -6 -28 -130 -125 -20 -46 -122 11 -34 -110 84 -100 -64 -16 -95 -17 -132 -42 -1 -192 -31 107 22 22 13 23 -57 114 -55 -201 30 -99 -12 63 89 49 235 85 -61 107 54 -12 -23 -4 -106 5 -5 57 93 -17 33 -22 -28 -4 -49 -33 35 -1 50 77 -70 -46 39 -22 -66 98 -56 13 57 56 57 -36 28 -40 -26 -39 -93 162 25 -10 140 -135 30 113 -149 3 167 -24 40 47 -8 3 49 -127 -7 -56 -171 86 -72 -39 SS 20230926T140302.2Z 8669.585442 203 1 46.40 2 59.76 122.11 155.82 332.63 0.00 1 0.00 1 0 33 1.653e-03 1.533e-03 1.416e-03 1.329e-03 8.681611e-07 4.342456e-07 6.445912e-08 3.960969e-07 5.292698e-07 227.92 -2.00 3.49 -2.00 340.01 0.00e+00 -1.950402e-05 1.188727e-04 1.486034e-05 6.244764e-05 1.452801e-04 285.51 -2.00 20.00 -2.00 337.41 0.00e+00 7.001702e-05 1.848680e-05 1.535557e-06 2.607250e-05 2.516572e-05 285.51 -2.00 20.00 -2.00 346.15 0.00e+00 1.497988e-04 5.391749e-05 1.305205e-05 1.300995e-05 7.205490e-05 285.51 -2.00 20.00 -2.00 344.70 0.00e+00 9.490405e+04 1.106936e+05 3.212066e+04 2.066324e+05 1.353098e+05 266.70 -2.00 11.20 -2.00 351.67 0.00e+00 2.411481e-01 1.661598e-03 1.938011e-03 3.288204e-03 1.755578e-03 227.92 -2.00 3.49 -2.00 330.40 0.00e+00 1.629773e-03 2.487426e-03 4.780231e-04 1.314305e-04 2.162287e-03 285.51 -2.00 20.00 -2.00 328.26 0.00e+00 1.977 0.000 319.50 362.20 4 4.8522e+00 1.8120e-03 1.3558e-02 1.4860e-03 2.3769e-03 4.3860e-02 4.4384e-04 2.1219e-03 2.6988e-04 5.4051e-04 -3.1125e-03 8.4379e-04 3.8135e-04 9.1035e-05 1.0434e-03 -5.7947e-04 4.5126e-04 3.7651e-04 5.8600e-05 4.4258e-04 1.0101e-03 6.9081e-04 2.8224e-04 6.9190e-05 7.8083e-04 1.9211e-03 -7.0164e-03 1.0991e-03 1.7271e-04 7.1320e-05 1.3609e-03 1.2407e-04 1.9505e-05 2.6351e-06 6.7907e-07 2.5092e-05 -2.3549e-02 0.0000e+00 -2.3319e-01 1.1578e-01 1.3145e-02 4.1610e-03 1.4255e-01 12 8 8 10 0 0 99.83 17.67 0.47 -0.02355 -0.02202 27 8 1 5 0 1717.980 21.06 14.99 17.67 25.32 27.9 966.89 -309 -57 432 510 369 -27 201 -24 338 159 126 -389 -123 -563 53 57 -150 209 -438 122 142 105 125 230 -169 93 -108 -128 0 43 -10 77 -6 -36 -107 -179 -213 -102 277 -25 12 122 19 99 38 -73 150 22 -69 -105 88 -60 -12 -24 -86 -11 -513 -53 -89 -413 -17 4 -82 79 132 46 84 60 -304 84 124 103 385 -154 -22 128 297 161 185 -162 -12 6 -70 83 -89 166 159 32 -196 -210 119 293 -113 -46 -37 6 15 35 -110 -112 235 -168 41 152 91 -184 344 -32 41 -344 6 114 189 23 -184 -190 224 133 -124 175 60 -78 -13 -106 -176 23 38 27 141 29 -61 178 -16 -214 -93 156 -236 -5 148 -128 37 120 -13 -29 245 1 -61 95 273 216 -2 334 117 -275 122 -211 -285 66 -110 -60 -59 -53 -73 92 -85 46 -36 -253 -106 -103 19 -10 -42 -179 -152 115 -30 -197 41 -159 -80 -95 -10 10 -347 -17 130 -9 -90 41 10 -104 -4 -16 -349 57 30 84 61 69 20 267 147 103 120 -2 62 2 -88 -77 -167 -60 187 121 -38 334 33 16 -75 -54 -84 124 173 108 -66 -78 13 -64 -110 134 55 -172 149 -87 -58 229 -54 -125 71 -98 -41 -343 165 77 16 7 -375 63 299 31 57 132 73 211 68 63 -22 172 -168 -346 -44 -32 154 -387 22 -165 -29 211 258 200 -16 120 -14 212 98 82 -264 -85 -399 37 38 -98 132 -281 81 102 82 97 190 -146 81 -95 -111 0 38 -9 69 -5 -31 -92 -154 -183 -85 224 -20 10 100 15 80 31 -63 138 20 -68 -105 90 -61 -13 -26 -87 -11 -471 -48 -80 -373 -16 4 -78 73 124 42 78 57 -289 76 113 95 360 -146 -21 120 278 150 177 -149 -11 6 -67 77 -87 167 163 33 -190 -202 117 301 -123 -48 -39 5 13 29 -96 -102 219 -158 39 131 74 -153 309 -30 41 -355 6 106 186 22 -190 -203 243 146 -132 176 58 -76 -14 -111 -198 26 44 31 153 30 -66 190 -18 -232 -98 159 -237 -5 153 -142 42 132 -14 -30 257 1 -70 109 312 242 -2 357 123 -283 117 -183 -236 57 -104 -59 -60 -57 -82 104 -97 52 -40 -272 -107 -106 19 -11 -46 -202 -166 128 -34 -215 45 -158 -81 -97 -10 11 -391 -18 141 -10 -100 45 10 -104 -4 -16 -358 60 33 93 73 84 25 323 176 121 143 -2 69 3 -94 -87 -189 -71 217 139 -39 341 32 17 -79 -63 -97 145 204 129 -81 -93 15 -77 -132 161 67 -213 185 -108 -71 276 -64 -149 84 -115 -46 -396 192 90 17 8 -393 60 279 29 56 131 78 230 72 62 -20 152 -142 -288 -37 -27 142 -391 24